Factors and Considerations for Modeling Loss of a GaN-based Inverter

The article investigates the impacts of four often-neglected factors on the loss model of a GaN-based full-bridge inverter: parasitic capacitance of the devices, dynamics of junction temperature (Tj) under time-varying power dissipation (Ploss), case temperature estimation, and detailed considerations of the passive components. Procedures to calculate the converter loss considering the above factors are proposed and implemented. A 4.5-kW hard-switching inverter prototype using gallium nitrite (GaN) high-electron-mobility transistors is used to experimentally demonstrate the impact of each factor on the converter loss model. Furthermore, it is found that the accuracy of a converter loss model is mainly affected by the passive components at the light load condition, whereas the thermal and loss models of the active components become the major factors as the output power increases. The results show that after considering the above factors, the converter loss discrepancy between calculation and measurement can be reduced from 30.6 W (28%) to 2.5 W (less than 3%) at heavy load (Po = 4.5 kW), while at the light load condition (Po = 500 W), it is reduced from 3.9 W (28%) to 2.6 W (16%). Furthermore, the difference between simulated and measured case temperature of the GaN devices is within 6 °C.

42 ENGINEERING↗

A Comprehensive Loss Model and Comparison of AC and DC Boost Converters

DC microgrids have become a prevalent topic in research in part due to the expected superior efficiency of DC/DC converters compared to their AC/DC counterparts. Although numerous side-by-side analyses have quantified the efficiency benefits of DC power distribution, these studies all modeled converter loss based on product data that varied in component quality and operating voltage. To establish a fair efficiency comparison, this work derives a formulaic loss model of a DC/DC and an AC/DC PFC boost converter. These converters are modeled with identical components and an equivalent input and output voltage. Simulated designs with real components show AC/DC boost converters between 100 W to 500 W having up to 2.5 times more loss than DC/DC boost converters. Although boost converters represent a fraction of electronics in buildings, these loss models can eventually work toward establishing a comprehensive model-based full-building analysis.

42 ENGINEERING↗

Off-design performance loss model for radial turbines with pivoting, variable-area stators

An off-design performance loss model was developed for variable stator (pivoted vane), radial turbines through analytical modeling and experimental data analysis. Stator loss is determined by a viscous loss model; stator vane end-clearance leakage effects are determined by a clearance flow model. Rotor loss coefficient were obtained by analyzing the experimental data from a turbine rotor previously tested with six stators having throat areas from 20 to 144 percent of design area and were correlated with stator-to-rotor throat area ratio. An incidence loss model was selected to obtain best agreement with experimental results. Predicted turbine performance is compared with experimental results for the design rotor as well as with results for extended and cutback versions of the rotor. Sample calculations were made to show the effects of stator vane end-clearance leakage.

Meitner, P. L.↗

Analysis of Reliabilities under Different Path Loss Models in Urban/Sub-Urban Vehicular Networks

This paper studies the impact of propagation path losses in urban/sub-urban vehicular networks. The impact has been analyzed considering both the network-layer and application-layer reliabilities. We have built a realistic vehicular simulation environment and performed an extensive simulation experiment in a semi-urban traffic environment. The results show that there are significant performance differences between LOS (Line-of-Sight)/OLOS (Obstructed-LOS)/NLOS (Non-LOS) path loss model and any other studied loss model. With a moderate communication distance between a transmitter and a receiver (300 m), while with the other existing loss models the network-level reliability is around 60%, with the LOS/OLOS/NLOS model that falls below 30%. Moreover, the application-level reliability of LOS/OLOS/NLOS model is not more than 55% for the delay sensitive safety application.

Ali, G. Nawaz↗

A High-Accuracy Power Loss Model of SiC MOSFETs in Current Source Inverter Considering Current Commutation and Parasitic Parameters

Power loss estimation of power electronic devices is important to the efficiency optimization of motor drives used in many applications. However, most existing simplified power loss models of silicon carbide (SiC) MOSFETs are not sufficiently accurate due to their neglect of parasitic parameters in the current commutation loop. In addition, the loss model of the voltage source inverter (VSI) cannot be directly applied to the current source inverter (CSI) because of differences between their commutation loops. First, the commutation processes for VSIs and CSIs are compared. The voltage and current trajectories of SiC MOSFETs in the switching transition of a CSI-based motor drive system are analyzed in detail. Based on these results, the conduction and switching losses of SiC MOSFETs in CSIs are modeled considering the current commutation details. In addition, the proposed analytical model includes parasitic inductances and capacitances in the current commutation loop. Experimental results have verified that the proposed power loss model delivers higher accuracy loss predictions than the conventional loss model.

current commutation, current source inverter, powe↗

Loss model for off-design performance analysis of radial turbines with pivoting-vane, variable-area stators

An off-design performance loss model for a radial turbine with pivoting, variable-area stators is developed through a combination of analytical modeling and experimental data analysis. A viscous loss model is used for the variation in stator loss with setting angle, and stator vane end-clearance leakage effects are predicted by a clearance flow model. The variation of rotor loss coefficient with stator setting angle is obtained by means of an analytical matching of experimental data for a rotor that was tested with six stators, having throat areas from 20 to 144% of the design area. An incidence loss model is selected to obtain best agreement with experimental data. The stator vane end-clearance leakage model predicts increasing mass flow and decreasing efficiency as a result of end-clearances, with changes becoming significantly larger with decreasing stator area.

Meitner, P. L.↗

Loss model for off-design performance analysis of radial turbines with pivoting-vane, variable-area stators

An off-design performance loss model is developed for variable-area (pivoted vane) radial turbines. The variation in stator loss with stator area is determined by a viscous loss model while the variation in rotor loss due to stator area variation (for no stator end-clearance gap) is determined through analytical matching of experimental data. An incidence loss model is also based on matching of the experimental data. A stator vane end-clearance leakage model is developed and sample calculations are made to show the predicted effects of stator vane end-clearance leakage on performance.

Meitner, P. L.↗

Scaling considerations for supercritical carbon dioxide cycles including turbomachinery loss models

A modeling framework for the supercritical carbon dioxide recompressed closed Brayton cycle was developed. Unlike typical models, this effort incorporated generalized empirical turbomachinery loss models. Aerodynamic, windage, and leakage losses were considered in order to address the limitations of conventional constant-efficiency turbomachinery assumptions without relying on machine-specific or computationally expensive simulations. The model enables system-level exploration of optimal cycle design across a range of power scales, including smaller scales that are relevant to microreactors and extraterrestrial power applications. Parametric studies and multi-objective optimizations are used to evaluate the trade-offs between thermal efficiency and system compactness based on an analytical heat exchanger scaling model, yielding Pareto-optimal fronts across a range of operating pressures. Results reveal that at small power scales, the Pareto-optimal compressor inlet pressure becomes subcritical due to the increasing influence of density-dependent turbomachinery losses. Here, the relative contributions of each loss mechanism are quantified, and design recommendations are provided for key parameters such as recompression split ratio and generator cavity pressure across varying power scales.

Multi-objective optimization↗

1D Heat Loss Models Validation Experiment

Contains data from the model validation in the 1D Heat Loss Models to Predict the Aquifer Temperature Profile during Hot/Cold Water Injection Project. The data include two COMSOL models (2D axisymmetric benchmark model and 2D Vinsome model), one python code (1D Vinsome based FEM numerical simulation), one matlab main code (1D Newton analytical solution and all results comparison visualization), and output files generated from the above models.

1D↗

Comparison of electron loss models in the inner magnetosphere during the 2013 St. Patrick's Day geomagnetic storm

Electrons with energies in the keV range play an important role in the dynamics of the inner magnetosphere. Therefore, accurately modeling electron fluxes in this region is of great interest. However, these calculations constitute a challenging task since the lifetimes of electrons that are available have limitations. In this study, we simulate electron fluxes in the energy range of 20 eV-100 keV to assess how well different electron loss models can account for the observed electron fluxes during the GEM Challenge Event of the 2013 St. Patrick's Day storm. Three models (Case 1, Case 2, and Case 3) of electron lifetimes due to wave-induced pitch angle scattering are used to compute the fluxes, which are compared with measurements from the Van Allen Probes. The three models consider electron losses due to interactions with whistler mode hiss waves inside the plasmasphere and with whistler mode chorus waves outside the plasmasphere. The Case 1 (historical) model produces excessive loss at low L shells before and after the storm, suggesting that it overestimates losses due to hiss during quiet times. During the storm main phase and early recovery all three models show good agreement with the observations, indicating that losses due to chorus during disturbed times are in general well accounted for by the models. Furthermore, the more recent Case 2 and Case 3 models show overall better agreement with the observed fluxes.

79 ASTRONOMY AND ASTROPHYSICS↗

Non-linear Model Predictive Control of Wave Energy Converters with Realistic Power Take-off Configurations and Loss Model

Model Predictive Control (MPC) has been recognized as a well-developed control strategy for optimizing the performance of wave energy converters (WECs). The standard problem involves maximizing the absorbed power from oncoming waves while respecting motion constraints of the device and force constraints of the power take-off (PTO). The generated electrical power is then calculated by assuming an ideal PTO with no power conversion losses or limitations to power flow. In this article, we remove the assumption of an ideal PTO and present four different control options that reflect unique combinations of PTO control and power flow constraints. We also recast the MPC problem to maximize the generated power instead of the absorbed power by accounting for the losses in the power train. Using a WEC with a hydraulic PTO, we develop a loss model suitable for controls optimization. Lastly, we illustrate the process of setting up the non-linear MPC problem and compare the performance of competing control strategies using a common benchmark based on annual energy captured at a reference site.

16 TIDAL AND WAVE POWER↗

Fermilab Booster loss modelling and rebalancing using Bayesian methods

To meet PIP-II upgrade requirements, Fermilab Booster losses need to be reduced by 50% compared to present levels. So far, simulations are not good enough to predict loss patterns. Thus, an extensive Booster tune up will be necessary to achieve required performance. In this paper we present an effort to build a data-driven loss model using Bayesian techniques, and subsequently to rebalance losses for higher trip margins. We first created several sets of spatially and temporally isolated orbit and optics knobs, and trained Gaussian process models for each beam loss monitor as well as beam current. Novel techniques of uncertainty constraints and approximate GP fitting were introduced to handle safety and timing requirements. We then performed single and multi-objective tuning using scalarized objectives comprised of critical beam loss locations. We achieved significant rebalancing of losses, increasing margins by 25%, as well as an overall improvement in transmission efficiency of 0.4%. Automated data collection is being developed so that more accurate surrogate models can be trained over time.

Kuklev, N. [Fermilab]↗

Setting operating points for circuits in an integrated circuit chip using an integrated voltage regulator power loss model

An apparatus includes an integrated circuit chip with a set of circuits having two or more subsets of circuits; an external voltage regulator separate from the integrated circuit chip; two or more integrated voltage regulators on the integrated circuit chip that each provide an input voltage to a respective subset of the circuits; and a controller. The controller determines, using an integrated voltage regulator power loss model, an electrical power loss for the integrated voltage regulators for a first combination of operating points for the subsets of the circuits. The controller then determines, based on the electrical power loss, a second combination of operating points for the subsets of the circuits that includes an adjustment to an operating point for at least one of the subsets of the circuits that compensates for an electrical power loss of the corresponding integrated voltage regulator. The controller sets an operating point of each of the subsets of the circuits based on the second combination of operating points.

42 ENGINEERING↗

Enhanced Inductance and Winding Loss Model for Coupled Inductors

An enhanced model for coupled inductors with significant fringing effect is developed in the form of equivalent circuit. The equivalent circuit is derived from a physical model that captures the flux paths through a leakage inductor and two mutual inductors on the primary and secondary side. A mutual winding resistor is added in parallel with the mutual inductor to model the winding loss affected by the fringing flux that penetrates the winding. The equivalent circuit is verified by finite-element simulation (FES) and successfully predicts the open-circuit winding loss and winding loss variation with phase-shift impact.

Xue, Lincoln↗

Radial diffusion in the Uranian radiatian belts - Inferences from satellite absorption loss models

Low-energy charged particle (LECP) phase space density profiles available from the Voyager/1986 Uranus encounter are analyzed, using solutions of the time-averaged radial diffusion equation for charged particle transport in a dipolar planetary magnetic field. Profiles for lower-energy protons and electrons are first analyzed to infer radial diffusion rate as a function of L, assuming that satellite absorption is the dominant loss process and local sources for these particles are negligible. Satellite macrosignatures present in the experimentally derived profiles are approximately reproduced in several cases, lending credence to the loss model and indicating that magnetospheric distributed losses are not as rapid as satellite absorption near the minimum satellite L shells for the particles. Diffusion rates and L dependences are found to be similar to those previously inferred in the inner Jovian magnetosphere (Thomsen et al., 1977) and for the inner Saturnian magnetosphere (Hood, 1985). Profiles for higher energy electrons and protons are also analyzed using solutions that allow for the existence of significant particle sources as well as sinks. Possible implications for radial diffusion mechanisms in the Uranian radiation belts are discussed.

Hood, L. L.↗

Fourier Analysis and Loss Modeling for Inductive Wireless Electric Vehicle Charging with Reduced Stray Field

With the growth of electric vehicle (EV) popularity, different charging options to increase user convenience and reduce charging times are being considered and researched. Among these, inductive wireless power transfer (WPT) systems for EVs are being designed to meet specifications such as stray field, power level, efficiency, misalignment tolerance, and ground clearance, which are all heavily influenced by the coil geometry. The proposed Fourier Analysis Method (FAM) is an analytical method to directly design coil geometries to meet stray field and power level requirements through an optimization of Fourier basis function coefficients. The outputs of the optimization are complex, planar coil geometries that meet the power level and stray field constraints with minimized loss factors. Contours of these potentials determine the coil conductor paths and loss models predict the system efficiency and performance over misalignment. The Fourier representation of the geometry is used to conveniently calculate the coupling over misalignment, external proximity effect loss, and ferrite loss. A 6.6 kW prototype WPT system with low stray field and high efficiency is built from the optimization results to validate the models and showcase the usefulness of the FAM design approach.

33 ADVANCED PROPULSION SYSTEMS↗

Performance Evaluation and Loss Modeling of WBG Devices based on a Novel Double-Pulse Test Method for Current Source Inverter

Careful measurements of the power device characteristics are necessary to accurately estimate a power converter's losses and efficiency. The conventional double-pulse test (DPT) circuit is a well-known method to implement this laboratory characterization of power devices and power modules. However, the switching characteristics of a power device depend on the power electronics circuit in which it is connected as well as the power circuit's physical layout, in addition to the device's internal structure. Hence, the conventional DPT circuit configuration, which is tailored for a standard voltage-source inverter (VSI), is not well-suited for a current-source inverter (CSI). This paper demonstrates a previously-proposed CSI-based DPT measurement technique that is appropriate for normal CSI operation. The characteristics of SiC MOSFETs and series-connected SiC Schottky diodes used in a CSI are measured using this improved technique while taking temperature effects into account to yield more accurate loss predictions. The CSI losses, including the switching and conduction losses of SiC MOSFETs and SiC Schottky diodes, have been modeled using this approach. The total CSI losses and efficiency have been estimated based on the CSI DPT results and loss models.

42 ENGINEERING↗

An Incidence Loss Model for Wave Rotors with Axially Aligned Passages

A simple mathematical model is described to account for the losses incurred when the flow in the duct (port) of a wave rotor is not aligned with the passages. The model, specifically for wave rotors with axially aligned passages, describes a loss mechanism which is sensitive to incident flow angle and Mach number. Implementation of the model in a one-dimensional CFD based wave rotor simulation is presented. Comparisons with limited experimental results are consistent with the model. Sensitivity studies are presented which highlight the significance of the incidence loss relative to other loss mechanisms in the wave rotor.