SAM Code Development for Transient Safety Analyses of Fluoride-salt-cooled High-temperature Reactors

The System Analysis Module (SAM) is under development at Argonne National Laboratory as a modern system-level modeling and simulation tool for advanced non-light water reactor safety analyses. It utilizes the object-oriented application framework MOOSE to leverage the modern software environment and advanced numerical methods. The capabilities of SAM are being extended to enable the transient modeling, analysis, and design of various advanced nuclear reactor systems. The molten-salt-cooled pebble-bed reactor, or pebble-bed FHR (PB-FHR) is a promising candidate among advanced nuclear reactor concepts with its improved passive safety characteristics and high thermal efficiency. To support the development and utilization of the SAM code for PB-FHR safety analysis, activities on SAM code enhancements, reference plant model developments, and code validations have been performed in the past a few years to support near-term industry and NRC needs. This report summarizes recent progress under DOE-NE’s Nuclear Energy Advanced Modeling and Simulation program in SAM code development and demonstration for transient safety analysis of Fluoride-salt-cooled High-temperature Reactors. SAM capabilities has been significantly enhanced over the years to add FHR specific modeling features, including salt freezing and thawing, spherical core channel and pebble bed core modeling, solid-fluid thermal radiation, tritium transport and general species transport in fluids and solids, and the general code enhancements on solver schemes of point kinetics module and reactivity feedback models. A reference PB-FHR model is developed, based on publicly available information from Kairos Power’s generic FHR design and the University of California, Berkeley (UCB) Mk1 design. A reference reactor model is foundational to the methodologies employed by NRC to verify the adequacy of computer codes and evaluation models. The reference FHR model was utilized for a number of selected FHR design basis accidents, including station blackout, loss of heat sink, loss of flow, transient overpower, and overcooling events.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Safety Analysis for the Versatile Test Reactor Conceptual Design

Safety analysis simulations have been carried out using the SAS4A/SASSYS-1 safety analysis code system to update the baseline set of results for the Versatile Test Reactor conceptual design. Results from a previous revision of this work provided input for the Conceptual Safety Design Report summarizing the overall safety basis for the VTR. This work will also support future analyses that will be required for Chapter 13, “Accident Analysis,” of a preliminary safety analysis report. A number of transients have been evaluated based on categories of postulated accident sequences suggested for consideration in NUREG-1537. Ultimately, the full spectrum of event initiators and subsequent accident sequences will be defined through a probabilistic risk assessment of the plant design following the implementation of the Licensing Modernization Project guidelines as described in the VTR Safety Design Strategy. Since that process is ongoing, the present analysis addresses several transients that are expected to be bounding accident scenarios that represent the three key ways to perturb a reactor: through changes to the core inlet temperature, mass flow rate, or reactivity. These correspond to a loss of heat sink (LOHS), loss of flow (LOF) or station blackout (SBO), and transient overpower (TOP), respectively. Both Protected and Unprotected versions of these transients have been evaluated, along with additional transients that include transient overpower with one stuck rod, pump coast-down failures, seismic events, and overcooling events. At the current stage of design, transient simulation results for the Versatile Test Reactor indicate that large safety margins exist for many event initiators. However, several “enabling” assumptions have been made, in terms of both design features and design limits, in order to perform the analyses; and these assumptions will need to be revised as the design matures. In addition, a larger spectrum of events needs to be evaluated as part of the on-going probabilistic risk assessment process.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Final Report on Predictive Analyses of PRD as Function of Anomalies

This report summarizes the work completed in FY-2024 to analyze the power reactivity decrement (PRD) concepts of the ARC-100 core. The PRD has been traditionally defined by the reactivity change from a hot zero power (HZP) to a particular power. Consequently, the PRD accounts for the core reactivity changes due to increase coolant temperature gradient axially and radially across the core, and increased fuel temperature. The coolant temperature gradient leads to sodium and structure density changes, to radial core expansion from assembly flowering and bowing (due to axial and radial temperature gradients within the assemblies), and to control rod driveline thermal expansion. The fuel temperature increase associated with coolant temperature and power increases leads to Doppler effect and axial thermal expansion. In this work, the normal operating Hot Full Power (HFP) state is the only power level of interest, so analyses focus on the PRD calculated from HZP to HFP. The PRD has been used to assess the reactor safety features asymptotically in unprotected accident scenarios, including the loss of heat sink (LOHS), loss of flow (LOF), and transient overpower (TOP) without scram. The PRD concept relies on the “global” reactivity coefficients A, B, and C that are estimated based on “individual” reactivity effects (Doppler, sodium density, etc.). The objectives of this work are: 1) to improve and verify the methodology used to calculate the ABC coefficients used in the PRD, 2) to assess if the PRD can be used to reliably identify abnormal events. This report fulfills the FY-2024 scope of WBS#1.15.8.3 activity, “ANL0120 – Predictive Analyses of PRD as function of deformation”. The PRD concept is described in Sections 2. Additional effort in refining the methodology for core bowing modeling is performed in Sections 3. Then, two verification exercises are proposed in Section 4 to benchmark these coefficients based on direct neutronic-only calculations and on dynamic core transient simulations. Finally, the PRD approach is assessed for the detection of several unexpected events, such as primary flow perturbation or improper fuel loading, in Section 5.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SAS4A/SASSYS-1 Validation with EBR-II Tests Performed During the SHRT Testing Program

The EBR-II sodium-cooled fast reactor supported a wide range of fast reactor research activities. The final fifteen years of operations at EBR-II were used for experiments and tests to demonstrate the importance of passive safety in liquid metal reactors and the capability of such systems to provide strong passive responses during off-normal conditions. The Shutdown Heat Removal Test program at EBR-II provided test data supporting the validation of computer codes for design, licensing, and operation of LMRs, among other objectives. The program included nearly sixty tests, most of which were protected and unprotected loss of flow and loss of heat sink tests run at various initial powers and flow rates. This report documents the results of modeling and simulation of tests from the Shutdown Heat Removal Test program to support validation of Argonne’s SAS4A/SASSYS-1 fast reactor safety analysis code. SHRT-17 was a protected loss of flow test where a loss of electrical power to all sodium coolant pumps was simulated to demonstrate the effectiveness of natural circulation cooling characteristics. SHRT-45R was an unprotected loss of flow test where the control rod scram function of the plant protection system was disabled to demonstrate the effectiveness of EBR-II’s passive reactivity feedbacks. BOP-301 and BOP-302R were unprotected loss of heat sink tests that demonstrated how reactivity feedback effects driven by changes to the core inlet temperature can shut down the fission process. This validation activity leverages modeling and simulation efforts that originated under an International Atomic Energy Agency Coordinated Research Project for benchmark analysis of the EBR-II Shutdown Heat Removal Tests. The SAS4A/SASSYS-1 models originally developed for the CRP have been modernized to utilize new code features and modeling practices. Differences between the predicted and measured test data were explored and the causes of these differences were identified as being due to modeling approximations, uncertainty in transient component behavior, and instrumentation uncertainties. Overall, it was concluded that for SHRT-17, SHRT-45R, BOP-301, and BOP-302R there was good agreement between the flow, power, and temperature predictions and the measured data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SAS4A/SASSYS-1 Validation with EBR-II Tests Performed During the SHRT Testing Program (Rev. 2)

The EBR-II sodium-cooled fast reactor supported a wide range of fast reactor research activities. The final fifteen years of operations at EBR-II were used for experiments and tests to demonstrate the importance of passive safety in liquid metal reactors and the capability of such systems to provide strong passive responses during off-normal conditions. The Shutdown Heat Removal Test program at EBR-II provided test data supporting the validation of computer codes for design, licensing, and operation of LMRs, among other objectives. The program included nearly sixty tests, most of which were protected and unprotected loss of flow and loss of heat sink tests run at various initial powers and flow rates. This report documents the results of modeling and simulation of tests from the Shutdown Heat Removal Test program to support validation of Argonne’s SAS4A/SASSYS-1 fast reactor safety analysis code. SHRT-17 and SHRT-6 were protected loss of flow tests where a loss of electrical power to all sodium coolant pumps was simulated to demonstrate the effectiveness of natural circulation cooling characteristics. SHRT-45R, SHRT-39, and SHRT-43R were unprotected loss of flow tests where the control rod scram function of the plant protection system was disabled to demonstrate the effectiveness of EBR-II’s passive reactivity feedbacks. BOP-301 and BOP-302R were unprotected loss of heat sink tests that demonstrated how reactivity feedback effects driven by changes to the core inlet temperature can shut down the fission process. PICT-5/6 demonstrated how core power could be increased and decreased via changes in the intermediate sodium and feedwater flow rates. This validation activity leverages modeling and simulation efforts that originated under an International Atomic Energy Agency Coordinated Research Project for benchmark analysis of the EBR-II Shutdown Heat Removal Tests. The SAS4A/SASSYS-1 models originally developed for the CRP have been modernized to utilize new code features and modeling practices. Differences between the predicted and measured test data were explored and the causes of these differences were identified as being due to modeling approximations, uncertainty in transient component behavior, and instrumentation uncertainties. Overall, it was concluded that for all tests simulated there was good agreement between the flow, power, and temperature predictions and the measured data.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

The Monolithic Heat Pipe Microreactor Reference Plant Model

This work introduces a reference plant model for a generic monolithic heat-pipe-cooled microreactor. The model will serve as a springboard to develop future evaluation models in the licensing process of similar microreactor designs at the U.S. Nuclear Regulatory Commission. This model has been developed with the Comprehensive Reactor Analysis Bundle and its specifications are based on open literature publications for the eVinci TM design. BlueCRAB is the U.S. Nu- clear Regulatory Commission non-light-water reactor analysis system based on the Multiphysics Object-Oriented Simulation Environment framework, which can couple the Griffin, BISON, and Sockeye applications to resolve the various physics that are essential for the safety analysis of this type of reactor system. The core specifications includes tristructural isotropic fuel, graphite monolith, graphite reflectors, and drums composed of graphite and B 4 C. No moderator or burnable poison pins are used in the design. The fuel enrichment is reduced to control excess reactivity in the core. This core design is not optimized and only serves for testing purposes, since the primary objective of this work is to exercise the multiphysics coupling for this type of reactor system. A three dimensional (3D) core heterogeneous Griffin discrete ordinates (SN) transport model allows the precise calculation of the flux distribution and pin powers. Griffin transfers the power density distribution and obtains a temperature distribution to and from BISON. The BISON model com- putes the 3D core temperature distribution and is coupled to 876 Sockeye subapplications running a heat pipe model. This 3D conduction model is coupled to the various heat pipes via heat flux boundary conditions. The model includes a small gap between the heat pipe and the monolith. Convective heat transfer boundaries with either ambient temperature or condenser temperature as heat sinks are imposed at the model boundaries. The 2D Sockeye heat pipe model uses a vapor- only methodology, which provides the needed resolution for transient calculations and allows the determination of various heat pipe limits. This approach is superior to the superconductor model traditionally used in steady-state calculations. BlueCRAB computes steady-state power and temperature distributions that serve as the initial condition for a loss-of-heat-sink transient simulation. The steady-state results show significant peaking due to the position of the control drum, but this is a characteristic of the particular design used, which is not optimized at this stage. The transient results show the reactor power slowly stabilizing towards a 3% power level after the partial loss of secondary heat removal. Several recriticalities are observed due to cooling through the secondary system but the reactor is self-stabilizing and behaves as expected.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Conceptual core design of the molten metal fueled microreactor with self-regulating capability

The microreactor concept has received significant attention in the United States for its lower capital investment, siting flexibility and high mobility. A microreactor aims to provide reliable electricity in remote communities, mining areas, or isolated islands, which will save the high fuel transportation cost. Thus, minimizing the staff level for operating and maintaining a microreactor is desirable. The objective of the study is to design a self-regulated Molten Metal fueled microReactor core (MMR) and to demonstrate the self-regulating capability of the MMR core. The control of the reactor is solely relying on reactivity feedbacks from fuel temperature perturbation. Molten UMn (liquid form at the temperature over 720°C) was utilized as the fuel material in MMR due to the larger thermal expansion coefficient compared to the conventional solid fuel. The MMR core has a fast neutron spectrum, which corresponds to a small burnup reactivity swing. The core design parameters were selected based on DAKOTA, REBUS, and ANLHTP calculations. The MMR is designed to run for 10 years at a power level of 15 MWth. Furthermore, no refueling is needed during the reactor lifetime. The system dynamic analyses were performed, and it was found that the reactor can be self-regulating within a temperature range of 800 ± 80°C for a loss of heat sink transient.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

SAS4A/SASSYS-1 Validation with the EBR-II Tests SHRT-17 and SHRT-45R

The EBR-II sodium-cooled fast reactor supported a wide range of fast reactor research activities. The final fifteen years of operations at EBR-II were used for experiments and tests to demonstrate the importance of passive safety in liquid metal reactors and the capability of such systems to provide strong passive responses during off-normal conditions. The Shutdown Heat Removal Test program at EBR-II provided test data supporting the validation of computer codes for design, licensing, and operation of LMRs, among other objectives. The program included nearly sixty tests, most of which were protected and unprotected loss of flow and loss of heat sink tests run at various initial powers and flow rates.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Preliminary Safety Analysis for a 400-kW Molten Salt Nuclear Battery

The Molten Salt Nuclear battery (MsNB) is a microreactor based on technology developed and operated at Oak Ridge National Laboratory in the 1960s [1]. But the MsNB has been simplified by removing pumps and valves for improved reliability and safety. The MsNB can safely provide up to 10 MWe of power for up to 10 years and potentially it can be transported by air, truck, and rail thanks due to to its small footprint. A computer model has been developed to represent a prototypical 400-kW MsNB using the ANL system code SAM [2]. The model has been used to produce a reactor thermal-hydraulic performance map and perform analysis of unprotected loss of heat sink accident scenario.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Device and method for measuring thermal conductivity of thin films

A device and method are provided for measuring the thermal conductivity of rigid or flexible, homogeneous or heterogeneous, thin films between 50 .mu.m and 150 .mu.m thick with relative standard deviations of less than five percent. The specimen is sandwiched between like material, highly conductive upper and lower slabs. Each slab is instrumented with six thermocouples embedded within the slab and flush with their corresponding surfaces. A heat source heats the lower slab and a heat sink cools the upper slab. The heat sink also provides sufficient contact pressure onto the specimen. Testing is performed within a vacuum environment (bell-jar) between 10.sup.-3 to 10.sup.-6 Torr. An anti-radiant shield on the interior surface of the bell-jar is used to avoid radiation heat losses. Insulation is placed adjacent to the heat source and adjacent to the heat sink to prevent conduction losses. A temperature controlled water circulator circulates water from a constant temperature bath through the heat sink. Fourier's one-dimensional law of heat conduction is the governing equation. Data, including temperatures, are measured with a multi-channel data acquisition system. On-line computer processing is used for thermal conductivity calculations.

Amer, Tahani R.↗

Unique safety features and licensing requirements of the NuScale small modular reactor

Small modular reactors (SMR) offer a novel approach to the construction and operation of nuclear power plants. The NuScale VOYGR™ plant uses a simplified SMR design that is based on proven light-water reactor technology with substantial improvements in nuclear safety. It consists of a 250 MWt reactor core housed with other primary system components in an integral reactor pressure vessel surrounded by a steel containment vessel, all of which is immersed in a large pool of water that also serves as the ultimate heat sink. At the core of the NuScale safety case are three primary safety systems: the decay heat removal system, the emergency core cooling system, and the containment. The ability of the NuScale Power Module (NPM) passive safety systems to remove core decay heat for an unlimited duration is demonstrated through analysis of a beyond-design-basis extended loss of AC power with no replenishment of water to the ultimate heat sink or operator actions. The NuScale methodology to evaluate an indefinite loss of AC power uses the proprietary NRELAP5 systems analysis computer code. Analysis results show that the reactor coolant system liquid level above the core is maintained and that containment pressure remains below the vessel design pressure. Once full passive air cooling is established, containment pressure and temperature will decrease over time with decreasing core decay heat. NuScale received standard design approval in September 2020 and design certification in January 2023 for its 50 MWe NPM configured as a 12 module plant. NuScale is currently seeking standard design approval to increase its core power to 250 MWt, nominally 77 MWe per module, in a 6-module plant (VOYGR™-6) configuration. The high-level safety of NuScale’s SMR technology is foundational to a new standard of nuclear power plant resilience.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Reexamination of METMAN, Recommendations on Enhancement of LCVG, and Development of New Concepts for EMU Heat Sink

METMAN is a 41-node transient metabolic computer code developed in 1970 and revised in 1989 by Lockheed Engineering and Sciences, Inc. This program relies on a mathematical model to predict the transient temperature distribution in a body influenced by metabolic heat generation and thermal interaction with the environment. A more complex 315-node model is also available that not only simulates the thermal response of a body exposed to a warm environment, but is also capable of describing the thermal response resulting from exposure to a cold environment. It is important to compare the two models for the prediction of the body's thermal response to metabolic heat generation and exposure to various environmental conditions. Discrepancies between the twi models may warrant an investigation of METMAN to ensure its validity for describing the body's thermal response in space environment. The Liquid Cooling and Ventilation Garment is a subsystem of the Extravehicular Mobility Unit (EMU). This garment, worn under the pressure suit, contains the liquid cooling tubing and gas ventilation manifolds; its purpose is to alleviate or reduce thermal stress resulting from metabolic heat generation. There is renewed interest in modifying this garment through identification of the locus of maximum heat transfer at body-liquid cooled tubing interface. The sublimator is a vital component of the Primary Life Support System (PLSS) in the EMU. It acts as a heat sink to remove heat and humidity from the gas ventilating circuit and the liquid cooling loop of the LCVG. The deficiency of the sublimator is that the ice, used as the heat sink, sublimates into space. There is an effort to minimize water losses in the feedwater circuit of the EMU. This requires developing new concepts to design an alternative heat sink system. Efforts are directed to review and verify the heat transfer formulation of the analytical model employed by METMAN. A conceptual investigation of regenerative non-venting heat-sink subsystem for the EMU is recommended.

Karimi, Amir↗

On the Influence of a Fuel Side Heat-Loss (Soot) Layer on a Planar Diffusion Flame

A model of the response of a diffusion flame (DF) to an adjacent heat loss or 'soot' layer on the fuel side is investigated. The thermal influence of the 'soot' or heat-loss layer on the DF occurs through the enthalpy sink it creates. A sink distribution in mixture-fraction space is employed to examine possible DF extinction. It is found that (1) the enthalpy sink (or soot layer) must touch the DF for radiation-induced quenching to occur; and (2) for fuel-rich conditions extinction is possible only for a progressively narrower range of values ot the characteristic heat-loss parameter, N(sub R)(Delta Z(sub R)) Various interpretations ot the model are discussed. An attempt is made to place this work into the context created by previous experimental and computational studies.

Wichman, Indrek S.↗

SAS4A/SASSYS-1 Modeling Improvements for the Transition to Natural Circulation

SAS4A/SASSYS-1 (SAS) is a simulation tool used to perform deterministic analyses of anticipated events as well as design basis and beyond design basis accidents for advanced liquid-metal-cooled nuclear reactors. With its origin as SAS1A in the late 1960s, the SAS series of codes has been under continuous use and development for over fifty years and represents a critical investment in safety analysis capabilities for the U.S. Department of Energy. In recent years, SAS has undergone a number of improvements to enable improved safety analyses that meet end users’ modernized needs while complying with the current regulatory environment. Improvements made in versions 5.6 and 5.7 released within the last year include the development of anisotropic Reynolds number dependent loss coefficients throughout the core and heat transport systems, the ability to distinguish the transition friction factor from the fully developed laminar and turbulent friction factors, and timedependent direct coolant and wall heating for pipe-like elements in the heat transport systems. While it was possible to capture loss coefficients, friction factors, and heat transfer from an element to a heat sink within SAS in previous versions of the code, users were required to end the simulation and restart it to adjust the input to account for any significant changes to the values during the transient. With these improvements, users can better capture flow reversal, pump heating, and the transition from forced to natural circulation without being limited to constant orifice coefficients, constant heat sinks, or the need to restart the simulation and modify input. In order to demonstrate the application of these improvements, a loss of flow transient is simulated for the Advanced Burner Test Reactor (ABTR).

SAS4A/SASSYS-1↗

1.9 THz Quantum-cascade Lasers with One-well Injector

We report terahertz quantum-cascade lasers operating predominantly at 1.90 THz with side modes as low as 1.86 THz (lambda approx. equal to 161 micrometers, planck's constant omega approx. equal to 7.7 meV). This is the longest wavelength to date of any solid-state laser that operates without assistance of a magnetic field. Carriers are injected into the upper radiative state by using a single quantum-well injector, which resulted in a significant reduction of free-carrier losses. The laser operated up to a heat-sink temperature of 110 K in pulsed mode, 95 K in continuous wave (cw) mode, and the threshold current density at 5 K was approx. 140 A per square centimeters.

Kumar, Sushil↗

Coupled evolution of the atmospheres and interiors of planets and satellites

The evolution of a planetary atmosphere can be powerfully influenced by the planetary interior's function as both a source and a sink of atmospheric constituents; the interior can in turn be strongly influenced by the atmosphere because the mechanism of interior heat loss depends on a volatile content for which the atmosphere can serve both as sink and source. The dependence of mantle rheology on volatile content could furnish a feedback mechanism tending to keep regassing/degassing in balance, thereby maintaining a relatively constant atmospheric mass. Consideration of the abundances of radiogenic and nonradiogenic noble gases in the earth's atmosphere, and of the fluxes of these gases from the mantle, support a large degassing event early on, followed by a decrease in degassing efficiency with time and relatively inefficient outgassing over most of geologic time.

Schubert, G.↗