Mass spectrometric analyses of high performance polymers to assess their radiopurity as ultra low background materials for rare event physics detectors
Not Available
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Not Available
Not Available
Poly Ethylene Naphthalate (PEN) is an industrial polymer plastic which is investigated as a low background, transparent, scintillating and wavelength shifting structural material. PEN scintillates in the blue region and has excellent mechanical properties both at room and cryogenic temperatures. Thus, it is an ideal candidate for active structural components in experiments for the search of rare events like neutrinoless double-beta decay or dark matter recoils. Such optically active structures improve the identification and rejection efficiency of backgrounds events, like this improving the sensitivity of experiments. This paper reports on the production of radiopure and transparent PEN plates These structures can be used to mount germanium detectors operating in cryogenic liquids (LAr, LN). Thus, as first application PEN holders will be used to mount the Ge detectors in the LEGEND-200 experiment. The whole process from cleaning the raw material to testing the PEN active components under final operational conditions is reported.
Next-generation neutrinoless double-beta (0νββ) decay searches require a large detector/isotope mass and very low radioactive backgrounds. The upcoming LEGEND-1000 experiment (Large Enriched Germanium Experiment for Neutrinoless double-beta Decay) constitute a ton-scale array of several hundred high-purity germanium (HPGe) detectors enriched in 76Ge, the isotope of interest. It aims to reach a sensitivity beyond 10 28 years on the 0νββ decay half-life of 76Ge, necessitating an order of magnitude reduction in background with respect to the state of the art. This will require the implementation of a dedicated application specific integrated circuit (ASIC) preamplifier that will significantly lower background contribution compared to the conventional low-mass front end (LMFE) employed in the Majorana Demonstrator and LEGEND-200 experiments while maintaining or improving energy resolution and other performance parameters. Features include a high (9 MeV) dynamic range with noise low enough to achieve a trigger threshold of <1 keV, a single power supply to reduce background-inducing cabling, and a differential output to maintain signal integrity over several meters of transmission line. The chip would be optimized to operate in liquid argon (87 K) and be able to do so reliably for ten years. Following on from an earlier 180-nm prototype, we have developed a differential-output charge-sensitive preamplifier ASIC fabricated in a 65-nm process, 1×2 mm in size, that addresses these needs. Here, we present recent results from the successful testing and characterization of the first version of this device.
Abstract The International AXion Observatory (IAXO) is a large scale axion helioscope that will look for axions and axion-like particles produced in the Sun with unprecedented sensitivity. BabyIAXO is an intermediate experimental stage that will be hosted at DESY (Germany) and that will test all IAXO subsystems serving as a prototype for IAXO but at the same time as a fully-fledged helioscope with potential for discovery.One of the crucial components of the project is the ultra-low background X-ray detectors that will image the X-ray photons produced by axion conversion in the experiment. The baseline detection technology for this purpose are Micromegas (Microbulk) detectors. We will show the quest and the strategy to attain the very challenging levels of background targeted for BabyIAXO that need a multi-approach strategy coming from ground measurements, screening campaigns of components of the detector, underground measurements, background models, in-situ background measurements as well as powerful rejection algorithms. First results from the commissioning of the BabyIAXO prototype will be shown.
The DArk Matter In CCDs at Modane (DAMIC-M) experiment isdesigned to search for light dark matter (m$_{χ}$ < 10 GeV/c$^{2}$)at the Laboratoire Souterrain de Modane (LSM) in France. DAMIC-Mwill use skipper charge-coupled devices (CCDs) as a kg-scale activedetector target. Its single-electron resolution will enable eV-scaleenergy thresholds and thus world-leading sensitivity to a range ofhidden sector dark matter candidates. A DAMIC-M prototype, the LowBackground Chamber (LBC), has been taking data at LSM since2022. The LBC provides a low-background environment, which has beenused to characterize skipper CCDs, study dark current, and measureradiopurity of materials planned for DAMIC-M. It also allows testingof various subsystems like readout electronics, data acquisitionsoftware, and slow control. This paper describes the technicaldesign and performance of the LBC.
When alpha particles are emitted into a gas they create an ionization track of gas ions and electrons. In our commercial UltraLo instrument we apply a voltage between a planar sample and an anode, integrate the anode signal as it collects the electrons, and distinguish between alphas emitted from the sample and elsewhere (anode, sidewalls) by the duration and shape of the resultant signal. The major contributors limiting the instrument’s lower detection limit are cosmic rays that pass through the detector close to the sample and Rn decays that produce charge tracks the originate in the gas and end on the sample. In this work we proposed to identify and reject these events by converting the anode into a multi-pixel array and operating in time projection mode. Cosmic rays would be eliminated by generating charge on many pixels, while charge collection asymmetry would distinguish between sample events (Bragg curve up) and Rn events (Bragg curve down). We therefore proposed to modify an UltraLo by pixilating its anode, developing low noise, low power multiplexed electronics to track each pixel’s signal individually, and develop analysis software to make the required discriminations.
We find that it is possible to increase sensitivity to low energy physics in a third or fourth DUNE-like module with careful controls over radiopurity and some modifications to a detector similar to the DUNE Far Detector design. In particular, sensitivity to supernova and solar neutrinos can be enhanced with improved MeV-scale reach. A neutrinoless double beta decay search with $^{136}$Xe loading appears feasible. Furthermore, sensitivity to Weakly-Interacting Massive Particle (WIMP) Dark Matter (DM) becomes competitive with the planned world program in such a detector, offering a unique seasonal variation detection that is characteristic for the nature of WIMPs.
Here we find that it is possible to increase sensitivity to low energy physics in a third or fourth Deep Underground Neutrino Experiment (DUNE)-like module with careful controls over radiopurity and targeted modifications to a detector similar to the DUNE Far Detector design. In particular, sensitivity to supernova and solar neutrinos can be enhanced with improved MeV-scale reach. A neutrinoless double beta decay search with 136 Xe loading appears feasible. Furthermore, sensitivity to Weakly-Interacting Massive Particle (WIMP) Dark Matter becomes competitive with the planned world program in such a detector, offering a unique seasonal variation detection that is characteristic of the nature of WIMPs.
Not Available
If neutrinos are their own antiparticles the otherwise-forbidden nuclear reaction known as neutrinoless double beta decay can occur. The very long lifetime expected for these exceptional events makes its detection a daunting task. In order to conduct an almost background-free experiment, the NEXT collaboration is investigating novel synthetic molecular sensors that may capture the Ba dication produced in the decay of certain Xe isotopes in a high-pressure gas experiment. The use of such molecular detectors immobilized on surfaces must be explored in the ultra-dry environment of a xenon gas chamber. Here, using a combination of highly sensitive surface science techniques in ultra-high vacuum, we demonstrate the possibility of employing the so-called Fluorescent Bicolor Indicator as the molecular component of the sensor. We unravel the ion capture process for these molecular indicators immobilized on a surface and explain the origin of the emission fluorescence shift associated to the ion trapping.
Regretfully, the author list of the original paper did not contain the members of the groups being responsible for the HPGe screening, Radon emanation measurement and ICPMS surface characterization works. As the work performed is to be considered more than “just service work”, the authors together with the members of these groups have decided to amend the authors list. At publication the following authors were not included in the author list: • From Pacific Northwest National Laboratory, Richland, WA, U.S.A.: E.W. Hoppe, I.J. Arnquist, K.P. Hobbs, A.D. French, M.L. diVacri • From INFN, Laboratori Nazionali del Gran Sasso, 67100 Assergi, Italy: M. Laubenstein • From M. Smoluchowski Institute of Physics, Jagiellonian University, 30-348 Krakow, Poland: G. Zuzel The metadata of the present erratum are already correct.
The modeling of background sources in large volume detection systems requires accurate nuclear cross sections for a variety of reactions. Among the most important are (α,n) on light nuclei, where α particles, up to ≈9 MeV, are produced from the decay of actinides present in trace amounts in detection and structural material. In order to model the neutron energy spectra and production of other secondary particles, the partial cross sections are needed. Yet very little experimental data exists for these partial cross sections because past measurements, hampered by the experimental challenges of neutron detection, have focused mostly on total reaction cross section measurements. Here, in this paper, the partial cross section of the 13 C(α,n 1 ) 16 O reaction is reported for the first time. The measurements were made near the reaction threshold using a high energy resolution helium spectrometer. The measurements show a rapidly increasing cross section, which quickly becomes a significant fraction of the total reaction cross section. Measurements are compared with previous theory estimates and differences of more than an order of magnitude are found. A comparison is made with new total cross section measurements and the current level of consistency is demonstrated.
Abstract not provided.
Explore the source record for details and available documents.
Explore the source record for details and available documents.
Explore the source record for details and available documents.