Search NASA⌕ Search

SEARCH · Search NASA

Results for “low energy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Scintillating screens sensitivity and resolution studies for low energy, low intensity beam diagnostics

In order to investigate the limits of scintillating screens for beam profile monitoring in the ultra-low energy, ultra-low intensity regime, CsI:Tl, YAG:Ce, and a Tb glass-based scintillating fiber optic plate (SFOP) were tested. The screens response to 200 and 50 keV proton beams with intensities ranging from a few picoampere down to the subfemtoampere region was examined. In the following paper, the sensitivity and resolution studies are presented in detail for CsI:Tl and the SFOP, the two most sensitive screens. In addition, a possible use of scintillators for ultra-low energy antiproton beam monitoring is discussed.

43 PARTICLE ACCELERATORS↗

Optical transition radiation used in the diagnostic of low energy and low current electron beams in particle accelerators

Optical transition radiation (OTR) plays an important role in beam diagnostics for high energy particle accelerators. Its linear intensity with beam current is a great advantage as compared to fluorescent screens, which are subject to saturation. Moreover, the measurement of the angular distribution of the emitted radiation enables the determination of many beam parameters in a single observation point. However, few works deals with the application of OTR to monitor low energy beams. In this work we describe the design of an OTR based beam monitor used to measure the transverse beam charge distribution of the 1.9-MeV electron beam of the linac injector of the IFUSP microtron using a standard vision machine camera. The average beam current in pulsed operation mode is of the order of tens of nano-Amps. Low energy and low beam current make OTR observation difficult. To improve sensitivity, the beam incidence angle on the target was chosen to maximize the photon flux in the camera field-of-view. Measurements that assess OTR observation (linearity with beam current, polarization, and spectrum shape) are presented, as well as a typical 1.9-MeV electron beam charge distribution obtained from OTR. Some aspects of emittance measurement using this device are also discussed.

43 PARTICLE ACCELERATORS↗

Ab Initio Molecular Dynamics Simulations of Low-Energy Recoil Events in ThO2, CeO2, and ZrO2

Ab initio molecular dynamics simulations of low-energy recoil events in ThO2, CeO2, and ZrO2 have been carried out to determine the threshold displacement energies, resulting defect configurations, dynamics of defect generation, and role of charge transfer during the process. The results reveal that, in most cases, these fluorite structure oxides exhibit a similar response to low-energy recoils. A variety of different defect configurations are created, consisting mainly of vacancies and interstitials. Charge transfer occurs during the dynamic displacement process. Local charge redistribution leads to cation and O vacancies being negatively and positively charged, respectively. Likewise, due to charge redistribution, the cation and O interstitials are less positively and negatively charged, respectively, than the ions on lattice sites in perfect MO2.

Environmental Molecular Sciences Laboratory↗

Adsorption of CO on Low-Energy, Low-Symmetry Pt Nanoparticles: Energy Decomposition Analysis and Prediction via Machine-Learning Models

We present a systematic analysis of CO adsorption on Pt nanoclusters in the 0.2–1.5 nm size range with the aim of unraveling size-dependent trends and developing predictive models for site-specific adsorption behavior. Using an empirical-potential-based genetic algorithm and density functional theory (DFT) modeling, we show that there exists a size window (40–70 atoms) over which Pt nanoclusters bind CO weakly, the binding energies being comparable to those on (111) or (100) facets. The size-dependent adsorption energy trends are, however, distinctly nonmonotonic and are not readily captured using traditional descriptors such as d-band energies or (generalized) coordination numbers of the Pt binding sites. Instead, by applying machine-learning algorithms, we show that multiple descriptors, broadly categorized as structural and electronic descriptors, are essential for qualitatively capturing the CO adsorption trends. Nevertheless, attaining quantitative accuracy requires further refinement, and we propose the use of an additional descriptors—the fully frozen adsorption energy—that is a computationally inexpensive probe of CO–Pt bond formation. With these three categories of descriptors, we achieve an absolute mean error in CO adsorption energy prediction of 0.12 eV, which is similar to the underlying error of DFT adsorption calculations. Our approach allows for building quantitatively predictive models of site-specific adsorbate binding on realistic, low-symmetry nanostructures, which is an important step in modeling reaction networks as well as for rational catalyst design in general.

36 MATERIALS SCIENCE↗

New insights gained on mechanisms of low-energy proton-induced SEUs by minimizing energy straggle

In this study, we present low-energy proton single-event upset (SEU) data on a 65 nm SOI SRAM whose substrate has been completely removed. Since the protons only had to penetrate a very thin buried oxide layer, these measurements were affected by far less energy loss, energy straggle, flux attrition, and angular scattering than previous datasets. The minimization of these common sources of experimental interference allows more direct interpretation of the data and deeper insight into SEU mechanisms. The results show a strong angular dependence, demonstrate that energy straggle, flux attrition, and angular scattering affect the measured SEU cross sections, and prove that proton direct ionization is the dominant mechanism for low-energy proton-induced SEUs in these circuits.

74 ATOMIC AND MOLECULAR PHYSICS↗

Low energy light yield of fast plastic scintillators

Compact neutron imagers using double-scatter kinematic reconstruction are being designed for localization and characterization of special nuclear material. These neutron imaging systems rely on scintillators with a rapid prompt temporal response as the detection medium. As n-p elastic scattering is the primary mechanism for light generation by fast neutron interactions in organic scintillators, proton light yield data are needed for accurate assessment of scintillator performance. The proton light yield of a series of commercial fast plastic organic scintillators—EJ-200, EJ-204, and EJ-208—was measured via a double time-of-flight technique at the 88-Inch Cyclotron at Lawrence Berkeley National Laboratory. Using a tunable deuteron breakup neutron source, target scintillators housed in a dual photomultiplier tube configuration, and an array of pulse-shape- discriminating observation scintillators, the fast plastic scintillator light yield was measured over a broad and continuous energy range down to proton recoil energies of approximately 50 keV. Furthermore, this work provides key input to event reconstruction algorithms required for utilization of these materials in emerging neutron imaging modalities.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Neutralization of space charge on high-current low-energy ion beam by low-energy electrons supplied from silicon based field emitter arrays

Neutralization of space charge on a high-current and low-energy ion beam was attempted to reduce the divergence with an aid of low-energy electrons supplied from silicon based field emitter arrays (Si-FEAs). An argon ion beam with the energy of 500 eV and the current of 0.25 mA was produced by a microwave ion source. The initial beam divergence and the emittance were measured at the entrance of the analysis chamber in order to estimate the intrinsic factors for beam divergence. The current density distribution of the beam after transport of 730 mm was measured by a movable Faraday cup, with and without electron supply from Si-FEAs. A similar experiment was performed with tungsten filaments as an electron source. The results indicated that the electron supply from FEA had almost the same effect as the thermionic filament, and it was confirmed that both electron sources can neutralize the ion beam.

43 PARTICLE ACCELERATORS↗

Low energy beam transport system developments

For high brightness beam production it is important to preserve the brightness in the low energy beam transport system (LEBT) used to transport and match the ion beams to the next stage of acceleration, usually an RFQ. While electrostatic focusing can be problematic for high current beam transport, reliable electrostatic LEBT operation has been demonstrated with H{sup −} beams up to 60 mA. Now, however, it is commonly accepted that an optimal LEBT for high current accelerator applications consists of focusing solenoids with space charge compensation. Two-solenoid LEBTs are successfully used for high current (>100 mA) proton beam transport. Preservation of low emittances (~0.15 π mm-mrad) requires the addition of a heavy gas (Xe, Kr), which causes ~5% of proton loss in a 1 m long LEBT. Similar Xe densities would be required to preserve low emittances of H{sup −} beams, but such gas densities cause unacceptably high H{sup −} beam losses. A short LEBT with only one short solenoid, movable for RFQ matching, can be used for reduced negative ion stripping. A strong electrostatic-focusing LEBT has been successfully adopted for transport of high current H{sup −} beams in the SNS Front End. Some modifications of such electrostatic LEBTs are expected to improve the reliable transport of intense positive and negative ion beams without greatly degrading their low emittances. We concentrate on processes that determine the beam brightness degradation and on their prevention. Proposed improvements to the SNS electrostatic LEBT are discussed.

43 PARTICLE ACCELERATORS↗

The Low Energy Effective Area of the Chandra Low Energy Transmission Grating Spectrograph

The Chandra X-ray Observatory was successfully launched on July 23, 1999, and subsequently began an intensive calibration phase. We present the preliminary results from the in-flight calibration of the low energy response of the High Resolution Camera spectroscopic readout (HRC-S) combined with the Low Energy Transmission Grating (LETG) aboard Chandra. These instruments comprise the Low Energy Transmission Grating Spectrograph (LETGS). For this calibration study, we employ a pure hydrogen non-LTE white dwarf emission model (T = 25000 K and log g = 9.0) for comparison with the Chandra observations of Sirius B. The pre-flight calibration of the LETGS effective area only covered wavelengths shortward of 44 A (E less than 277 eV). Our Sirius B analysis shows that the HRC-S quantum efficiency (QE) model assumed for longer wavelengths leads to an overestimate of the effective area by an average factor of about 1.6. We derive a correction to the low energy HRC-S QE model to match the predicted and observed Sirius B spectra over the wavelength range of 44-185 A. We make an independent test of our results by the comparison of a Chandra LETGS observation of HZ 43 with pure hydrogen model atmosphere predictions and find good agreement.

Pease, D.↗

Low-Energy, Low-Cost Ethylene Production by Low-Temperature Oxidative Coupling of Methane

Ethylene, one of the highest volume production chemicals in the U.S. and globally, is an essential chemical building block that is used to manufacture countless products, from packaging to antifreeze to tires. Most ethylene is produced via a process called steam cracking, where the feedstock (mostly ethane, sometimes naphtha or propane) is heated to high temperatures over a catalyst. The naphtha feedstock typically comes from petroleum refineries, while ethane is becoming increasingly used as a feedstock in the U.S. due to the rise in domestic natural gas production from shale resources. However, steam cracking is energy intensive and occurs in large- scale facilities. Low-temperature oxidative coupling of methane (LT-OCM) is an alternative ethylene production method that converts methane (natural gas) and optionally ethane to ethylene in a single-step, energy-producing conversion system using an innovative process. While OCM has been studied for over 30 years due to its potential to reduce ethylene production cost, past efforts did not result in a viable catalyst with performance needed for commercialization. These catalysts, while at times achieving promising yield and selectivity, were hampered by very high operating temperatures, low activities, and short lifetimes on the order of hours to days. Recognizing this, Siluria applied a combination of new innovations in catalyst development and a thorough definition and understanding of the problem to develop unique catalysts that enable commercialization of OCM. The OCM catalysts operate at significantly lower temperature (several hundreds of degrees lower) and practical operating pressures (5-10 atmospheres), have high activities and standard lifetimes of years under said conditions. In addition, the simple process provides excellent scalability and flexibility, especially when compared to today’s mega-scale steam crackers, thus enabling small- volume “distributed scale” reactors for on-demand ethylene production for applications such as on-site conversion of ethylene to high value polymer derivatives.

02 PETROLEUM↗

2-D energy analyzer for low energy electrons

A 2-D electron energy analyzer is designed and constructed to measure the transverse and longitudinal energy distribution of low energy (<1 eV) electrons. The analyzer operates on the principle of adiabatic invariance and motion of low energy electrons in a strong longitudinal magnetic field. The operation of the analyzer is studied in detail and a design to optimize the energy resolution, signal to noise ratio, and physical size is presented. An energy resolution better than 6 meV has been demonstrated. Such an analyzer is a powerful tool to study the process of photoemission which limits the beam quality in modern accelerators.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-Energy, Low-Cost Production of Ethylene by Low- Temperature Oxidative Coupling of Methane

In this project, we develop a catalytic process technology for distributed small-scale production of ethylene by oxidative coupling of methane at low temperatures using an advanced catalyst. The Low Temperature Oxidative Coupling of Methane (LT-OCM) catalyst system is enabled by a novel chemical catalyst and process pioneered by Siluria, at private expense, over the last six years. Herein, we develop the LT-OCM catalyst system for distributed small-scale production of ethylene by identifying and addressing necessary process schemes, unit operations and process parameters that limit the economic viability and mass penetration of this technology to manufacture ethylene at small-scales. The output of this program is process concepts for small-scale LT-OCM catalyst based ethylene production, lab-scale verification of the novel unit operations adopted in the proposed concept, and an analysis to validate the feasibility of the proposed concepts.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗