Time-resolved synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument future timing detectors at the High Luminosity Large Hadron Collider (HL-LHC) experiments. While conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low energy X-rays with good energy resolution and excellent timing (tens of picoseconds). Here, using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 35 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2.1 ns intervals, and with an energy dispersion (ΔE/E) of 1 X 10 -4 . LGADs fabricated by Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 µm to 50 µm and different gain layer designs were read out a two stage fast amplification circuit and digitized with a high bandwidth, high sampling rate oscilloscope. PIN devices from HPK were characterized as well. A systematic and detailed characterization of the devices’ energy linearity, resolution and timing resolution as a function of X-ray energy was performed for different biasing voltages at room temperature

Charge multiplication↗

Fabrication of 4H-SiC Low Gain Avalanche Detectors (LGADs)

Low gain avalanche detectors (LGADs) offer high temporal resolution for high energy particle detection, which is critical for next generation experiments in hadron colliders. While silicon LGADs (Si-LGADs) have rapidly matured in the last decade, research into silicon carbide (SiC) LGADs has only recently begun. By accounting for fundamental differences in material properties and fabrication processes, we present a prototype device design and process flow for 4H-SiC LGADs with etch-based isolation. Critical steps of the process flow and their results are discussed, including plasma etching, passivation, and the formation of low resistivity contacts. Electrical characterization (I-V, C-V) shows sufficient depletion of the device structure to demonstrate low-gain charge carrier multiplication.

High Energy Physics↗

Diffused trenches for high fill-factor Low-Gain Avalanche Diodes

Low-Gain Avalanche Diodes (LGADs) are a class of silicon detectors that have been specifically designed for the fast detection of minimum ionizing particles (mips) in High-Energy Physics experiments. While they provide timing resolution on the order of a few tens of picoseconds, they cannot achieve high spatial resolution due to the intrinsic characteristics of their structures. Thus, active R&D is on-going to develop detectors based on LGADs to improve their spatial resolution while maintaining the timing performance of the LGADs. Such devices are, for example, AC-coupled LGADs and Deep-Junction LGADs. Another device option is the Trench-Isolated LGAD (TI LGAD), where trenches etched at the periphery of the pixels isolate them while providing a high fill-factor. Here, in this paper, we present a variation of this latter approach, demonstrating its feasibility by means of 2-dimensional TCAD simulations.

47 OTHER INSTRUMENTATION↗

Synchrotron light source X-ray detection with Low-Gain Avalanche Diodes

Abstract Low Gain Avalanche Diodes (LGADs) represent the state-of-the-art in timing measurements and will instrument the future Timing Detectors of ATLAS and CMS for the High-Luminosity LHC. While initially conceived as a sensor for charged particles, the intrinsic gain of LGADs makes it possible to detect low-energy X-rays with good energy resolution and excellent time resolution (tens of picoseconds). Using the Stanford Synchrotron Radiation Lightsource (SSRL) at SLAC, several LGADs designs were characterized with energies from 5 to 70 keV. The SSRL provides 10 ps pulsed X-ray bunches separated by 2 ns intervals with an energy dispersion (ΔE/E) of 10 -4 . LGADs from Hamamatsu Photonics (HPK) and Brookhaven National Laboratory (BNL) with different thicknesses ranging from 20 μm to 50 μm and different gain layer designs were read out using fast amplification boards and digitized with a high bandwidth and high sampling rate oscilloscope. PIN devices from HPK and AC-LGADs from BNL were characterized as well. A systematic and detailed characterization of the devices' energy linearity, resolution, and time resolution as a function of X-ray energy was performed for different biasing voltages at room temperature and are reported in this work. The charge collection and multiplication mechanism were simulated using Geant4 and TCAD Sentaurus, providing an important handle for interpreting the data.

Instruments & Instrumentation↗

Fabrication of Silicon Sensors Based on Low-Gain Avalanche Diodes

Low-Gain Avalanche Diodes are a recently-developed class of silicon sensors. Characterized by an internal moderate gain that enhances the signal amplitude and if built on thin silicon substrates of a few tens of microns, they feature fast signals and exhibit excellent timing performance. Thanks to their fast timing they are planned to be exploited in timing detectors in High-Energy Physics experiments, for example for the upgrades of the ATLAS and CMS detectors at the High Luminosity Large Hadron Collider (HL-LHC) at CERN. However, to achieve a spatially uniform multiplication a large pixel pitch is needed, preventing a fine spatial resolution. To overcome this limitation, the AC-coupled LGAD approach was introduced. In this type of device, metal electrodes are placed over an insulator at a fine pitch, and signals are capacitively induced on these electrodes. The fabrication technology is similar for the two LGAD families, although a fine tuning of a few process parameters needs to be carefully studied. Other R&D efforts towards detectors that can simultaneously provide good time and spatial resolution, based on the LGAD concept, are under way. These efforts aim also to mitigate the loss of performance at high irradiation fluences due to the acceptor removal within the gain layer. In this paper we describe the main points in the fabrication of LGADs and AC-LGADs in a clean-room. We also discuss novel efforts carried on related topics.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Characterization of 4H-SiC Low Gain Avalanche Detectors (LGADs)

4H-SiC Low Gain Avalanche Detectors (LGADs) have been fabricated and characterized. The devices employ a circular mesa design with low-resistivity contacts and an SiO 2 passivation layer. The I–V and C–V characteristics of the 4H-SiC LGADs are compared with complementary 4H-SiC PiN diodes to confirm a high breakdown voltage and low leakage current. Both LGADs and PiN diodes were irradiated with alpha particles from a $^{210}_{84}$Po source. The charge collected by each device was compared, and it was observed that low-gain charge carrier multiplication is achieved in the 4H-SiC LGAD.

43 PARTICLE ACCELERATORS↗

Spectroscopic performance of Low-Gain Avalanche Diodes for different types of radiation

LGADs (Low-Gain Avalanche Diodes or Detectors) are a type of silicon Avalanche Photo-Diodes originally developed for the fast detection of minimum ionizing particles in high-energy physics experiments. Thanks to their fast timing performance, the LGAD paradigm enables detectors to accurately measure minimum ionizing particles with a timing resolution of a few tens of picoseconds. Such a performance is due to a thin substrate and the presence of a moderate signal gain. This internal gain of a few tens is enough to compensate for the reduced charge deposition in the thinner substrate and the noise of fast read-out systems. While LGADs are optimized for the detection of minimum ionizing particles for high-energy particle detectors, it is critical to study their performance for the detection of different types of particle, such as X-rays, gamma-rays, or alphas. In this paper, we evaluate the gain of three types of LGADs: two devices with different geometries and doping profiles fabricated by Brookhaven National Laboratory, and one fabricated by Hamamatsu Photonics with a different process. Since the gain in LGADs depends on the bias voltage applied to the sensor, pulse-height spectra have been acquired for bias voltages spanning from the depletion voltage up to the breakdown voltage. Finally, the signal-to-noise ratio of the generated signals and the shape of their spectra allow us to probe the underlying physics of the multiplication process.

47 OTHER INSTRUMENTATION↗

Response of AC-coupled low gain avalanche detectors to ionizing and non-ionizing radiation damage

Low gain avalanche diodes with DC- and AC-coupled readout were exposed to ionizing and non-ionizing radiation at levels relevant to future experiments in particle, nuclear, and medical physics and to astrophysics. Damage-related change in their acceptor removal constants and in the resistivity of the region between the guard ring and the active area are reported, as is change in the leakage current and depletion voltages of the active volumes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Response of AC-coupled Low Gain Avalanche Detectors to Ionizing and Non-ionizing Radiation Damage

Low gain avalanche diodes with DC- and AC-coupled readout were exposed to ionizing and non-ionizing radiation at levels relevant to future experiments in particle, nuclear, and medical physics and to astrophysics. Damage-related change in their acceptor removal constants and in the resistivity of the region between the guard ring and the active area are reported, as is change in the leakage current and depletion voltages of the active volumes.

FOS: Physical sciences↗

Characterization of Low Gain Avalanche Detector Prototypes’ Response to Gamma Radiation

Motivated by the need for fast timing detectors to withstand up to 2 MGy of ionizing dose at the High Luminosity Large Hadron Collider, prototype low gain avalanche detectors (LGADs) have been fabricated in a single pad configuration, 2 × 2 arrays, and related p-i-n diodes, and exposed to Co-60 sources for study. Devices were fabricated with a range of dopant layer concentrations, and for the arrays, a variety of inter-pad distances and distances from the active area to the edge. Measurements of capacitance versus voltage and leakage current versus voltage have been made to compare pre- and post-irradiation characteristics in gain layer depletion voltage, full bulk depletion voltage, and breakdown voltage. Conclusions are drawn regarding the effects of the gammas on both surface and interface states and on their contribution to acceptor removal through non-ionizing energy loss from Compton electrons or photoelectrons. Comparison of the performances of members of the set of devices can be used to optimize gain layer parameters.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Investigation of low gain avalanche detectors exposed to proton fluences beyond 10 15 n eq cm -2

Abstract Low gain avalanche detectors (LGADs) deliver excellent timing resolution, which can mitigate mis-assignment of vertices associated with pileup at the High Luminosity LHC and other future hadron colliders. The most highly irradiated LGADs will be subject to 2.5 × 10 15 n eq cm -2 of hadronic fluence during HL-LHC operation; their performance must tolerate this. Hamamatsu Photonics K.K. and Fondazione Bruno Kessler LGADs have been irradiated with 400 and 500 MeV protons respectively in several steps up to 1.5 × 10 15 n eq cm -2 . Measurements of the acceptor removal constants of the gain layers, evolution of the timing resolution and charge collection with damage, and inter-channel isolation characteristics, for a variety of design options, are presented here.

Instruments & Instrumentation↗

Compare low-gain 1D and 3D models toward a storage ring-based X-ray free-electron-laser oscillator

Fourth-generation diffraction-limited synchrotron light sources (DL-SLS) present a compelling platform for advanced light source applications due to their ultra-low emittance (around tens of picometers), sub-micrometer beam stability, and high repetition rates (greater than 1 MHz). Despite these advantages, fundamental limitations, such as long bunch durations (tens of picoseconds), large relative energy spread (~10⁻³), and low peak current (<300 A), have hindered their effectiveness in free-electron laser (FEL) applications. Using a low-gain three-dimensional (3D) model based on NSLS-II upgrade lattice parameters, we demonstrate that a 6% single-pass gain is achievable with an optimized transverse gradient undulator (TGU). Concurrently, recent advances in X-ray optics—specifically, a four-mirror bow-tie resonator utilizing diamond mirrors and beryllium compound refractive lenses (CRLs)—enable total round-trip losses below 4% and an output coupling efficiency near 1%, rendering a Storage Ring based X-ray FEL oscillator (XFELO) a realistic possibility. In the 3D framework, the TGU effectively mitigates the detrimental effects of large energy spread by spatially dispersing the beam, leading to enhanced gain relative to conventional one-dimensional (1D) models. We establish both analytical and numerical connections between the 1D and 3D descriptions, leveraging GENESIS simulations to map equivalent gain conditions. While 1D resonance is defined in the energy domain, the 3D TGU system shifts the resonance dependence to transverse gradient and dispersion parameters. Once optimized, this framework allows predictive modeling using 1D formulas, which can then be validated through full 3D simulations.

43 PARTICLE ACCELERATORS↗

Radiation hardness of the low gain avalanche diodes developed by NDL and IHEP in China

This paper presents a study on the radiation hardness of low gain avalanche detector (LGAD) developed by the Novel Device Laboratory (NDL) in Beijing and the Institute of High Energy Physics (IHEP) of Chinese Academy of Sciences, in the context of an upgrade project of the ATLAS detector for the high luminosity phase of LHC. NDL LGAD sensors with different layouts, epitaxial resistivity and doping profile were irradiated up to 1.02 × 10 15 n eq /cm 2 by 70 MeV protons at Cyclotron and Radioisotope Center (CYRIC). The timing resolution of NDL LGAD sensors reached 50 ps and the collected charge reached 3 - 4 fC after irradiation.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Impact of proton irradiation on 4H-SiC Low Gain Avalanche Detectors (LGADs)

Silicon carbide (SiC) particle detectors have the potential to provide time resolutions and robust performance in extreme environments which exceed that of silicon detectors. In this work 4H-SiC low gain avalanche detectors (LGADs) and complementary PiN diodes were irradiated with 2.5 GeV protons at fluences up to 3.33 × 10 14 p/cm 2 . The electrostatic performance of both irradiated and non-irradiated devices was evaluated using I-V and C-V measurements. Moreover, charge collection measurements using α particles were also conducted. SiC LGADs displayed a loss in rectification, high ON-state resistances >10 10 Ω-cm 2 , and the complete removal of gain when exposed to the highest proton fluence. Additionally, the reductions in capacitance and OFF-state current pointed to compensation of the gain layer as a gain reducing mechanism. The introduction of radiation-induced defects also hinders carrier acceleration, which reduces impact ionization and further gain reduction. LGADs exposed to a fluence of 1 × 10 14 p/cm 2 experienced a partial recovery in gain (originally having a value of ∼ 2) with a value of ∼ 1.65 when applying a bias of 500 V. Charge trapping was also seen in the reduction of charge collection efficiency (CCE) to ∼ 65% for the PiN diode. However, despite the reduction in device performance, the demonstration of a measurable signal after irradiation points to the potential of SiC LGAD detectors for future high energy physics applications.

43 PARTICLE ACCELERATORS↗

Performance in beam tests of irradiated Low Gain Avalanche Detectors for the ATLAS High Granularity Timing Detector

The High Granularity Timing Detector (HGTD) will be installed in the ATLAS detector to mitigate pile-up effects during the High Luminosity (HL) upgrade of the Large Hadron Collider (LHC) at CERN. The design of the HGTD is based on the use of Low Gain Avalanche Detectors (LGADs), with an active thickness of 50 μm, that allow to measure with high-precision the time of arrival of particles. The HGTD will improve the particle-vertex assignment by measuring the track time with a resolution ranging from approximately 30 ps at the beginning of the HL-LHC operations to 50 ps at the end. Performances of several unirradiated, as well as neutron- and proton-irradiated, LGAD sensors from different vendors have been measured in beam test campaigns during the years 2018 and 2019 at CERN SPS and DESY. This paper presents the results obtained with data recorded by an oscilloscope synchronized with a beam telescope which provides particle position information within a resolution of a few μm. Collected charge, time resolution and hit efficiency are presented. In addition to these properties, the charge uniformity is also studied as a function of the position of the incident particle inside the sensor pad.

47 OTHER INSTRUMENTATION↗

UV hybrid photon detector based on GaN photocathodes and Si low gain avalanche diode

Photon detectors featuring single-photon sensitivity play a crucial role in various scientific domains, including high-energy physics, astronomy, and quantum optics. Fast response time, high quantum efficiency, and minimal dark counts are the characteristics that render them ideal candidates for detecting individual photons with exceptional signal-to-noise ratios, at frequencies in the range of hundreds of MHz. Here, in this study, we report on our first design and operational results on a Hybrid Photon Detector (HPD) that combines the high quantum efficiency of a Gallium Nitride (GaN) photocathode and the low noise characteristics of a Si-based Low-Gain Avalanche Diode (LGAD). This hybrid detection scheme has the potential to reach single-photon detection sensitivity with high quantum efficiency, low noise levels and capable of operating at hundreds of MHz repetition rates.

47 OTHER INSTRUMENTATION↗

Inferring fusion nuclear burnwidths with low gain photomultiplier impulse response functions

When an inertial confinement fusion implosion is compressed, it maintains thermonuclear density and temperatures for a very short time scale, about 100 ps. The Gamma Reaction History diagnostic measures the time evolution of the fusion burn, but its temporal resolution is limited by the use of a photomultiplier tube (PMT) to amplify the photon signal. Multichannel plate-based PMTs have a fast (~120 ps) full-width at half-max impulse response function (IRF), but the time scale is similar to the incoming physics signal. An analysis routine is used to remove the effect of the PMT IRF and infer the incident fusion burnwidth. With the National Ignition Facility achieving ignition and creating much brighter signals, the PMTs are run at gains three orders of magnitude lower than nominal operation. Calibration at these settings shows the PMT IRFs get ~15% wider. Taking the gain-dependent IRF can affect the inferred nuclear burnwidths by up to ~15%.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗