Search NASA⌕ Search

SEARCH · Search NASA

Results for “low light level imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Toward real-time quantum imaging with a single pixel camera

In this paper, we present a workbench for the study of real-time quantum imaging by measuring the frame-by-frame quantum noise reduction of multi-spatial-mode twin beams generated by four wave mixing in Rb vapor. Exploiting the multiple spatial modes of this squeezed light source, we utilize spatial light modulators to selectively pass macropixels of quantum correlated modes from each of the twin beams to a high quantum efficiency balanced detector. Finally, in low-light-level imaging applications, the ability to measure the quantum correlations between individual spatial modes and macropixels of spatial modes with a single pixel camera will facilitate compressive quantum imaging with sensitivity below the photon shot noise limit.

47 OTHER INSTRUMENTATION↗

Entangled-photon compressive ghost imaging

We have experimentally demonstrated high-resolution compressive ghost imaging at the single-photon level using entangled photons produced by a spontaneous parametric down-conversion source and using single-pixel detectors. For a given mean-squared error, the number of photons needed to reconstruct a two-dimensional image is found to be much smaller than that in quantum ghost imaging experiments employing a raster scan. This procedure not only shortens the data acquisition time, but also suggests a more economical use of photons for low-light-level and quantum image formation.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Low Distortion Lens Design for Large Scintillators

Tomographic imaging of large objects from an x-ray source require a 240 mm square scintillator that is imaged onto a 90 mm square charge-coupled device (CCD) with <0.01% distortion. A large pellicle and internal folding mirror keep the optical elements and the CCD camera out of the x-ray beam path to minimize shielding requirements. Better imaging is needed for 2-D digital radiography and computer tomography (3-D) on the Los Alamos National Laboratory’s Microtron x-ray–generating source, a bremsstrahlung source with endpoint energies of 6, 10, 15, and 20 MeV. Large objects are placed into the x-ray beam and rotated between radiographs. X-rays are deposited into scintillators that are viewed with digital cameras. Better light gathering is needed because the scintillators emit low levels of light. Earlier imaging techniques used film in contact with the scintillator. Our design goal is to match the resolution of the digital camera system to that of the film. 3-D tomography requires extremely low distortion of the collected images.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

A simple multipurpose double-beam optical image analyzer

In the paper we present a low cost optical device which splits the light in the focal plane into two separate optical paths and collimates it back into a single image plane, and where a selective information processing can be carried out. The optical system is straightforward and easily implementable as it consists of only three lenses and two mirrors. The system is dedicated for imaging in low-light-level conditions in which widely used optical devices, based on beam splitters or dichroic mirrors, suffer from light loss. We expose examples of applications of our device, using a prototype model. The proposed optical system may be employed for: monitoring the objects located at different distances from observer (1), creating regions of different magnification within a single image plane (2), high dynamic range photometry (3), or imaging in two wavelength bands simultaneously (4).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Large-Format, Fully-Depleted, Back-Illuminated CMOS Imaging Technology

A Voxtel-led team has developed a new class of large-area, high-performance, backside-illuminated CMOS imaging sensor for low-light-level surveillance applications, specifically designed for both low-noise and high near-infrared (NIR) response. The imager integrates two technologies: 1) large-area backside-illuminated (BSI) imaging; and 2) high-density 3D via-less electrical interconnection and wafer bonding. In this program, Voxtel, in collaboration with Jazz Semiconductor, Sharp Labs and Ziptronix Inc., developed and fabricated a wafer-scale imaging platform. We integrated the design rules necessary for large-area photocomposition using a sub-field stitched reticle at Jazz, and wafer-scale 3D stacked electrical connect using the Ziptronix process. The Jazz CA25QFES process was shown to be ideal for use in the Ziptronix process because of its compatibility with the last via back end of line (BEOL) process used to create tungsten vias up to the wafer surface. To accomplish program goals, Voxtel integrated and fabricated a stitched CMOS ROIC design, and bonded the ROIC to an array of thick, high-resistivity, fully depleted pinned silicon photodiodes, fabricated in a silicon-on-insulator (SOI) wafer. By fabricating the detector and ROIC separately, the silicon used to fabricate the circuits from the ROIC and the fully depleted, high-resistivity silicon detector array are optimized for their respective tasks, improving their performance, increasing yield, and reducing cost.

14 SOLAR ENERGY↗

High-sensitivity, high-speed continuous imaging system

A continuous imaging system for recording low levels of light typically extending over small distances with high-frame rates and with a large number of frames is described. Photodiode pixels disposed in an array having a chosen geometry, each pixel having a dedicated amplifier, analog-to-digital convertor, and memory, provide parallel operation of the system. When combined with a plurality of scintillators responsive to a selected source of radiation, in a scintillator array, the light from each scintillator being directed to a single corresponding photodiode in close proximity or lens-coupled thereto, embodiments of the present imaging system may provide images of x-ray, gamma ray, proton, and neutron sources with high efficiency.

36 MATERIALS SCIENCE↗

Purely spatial coincidences of twin photons in parametric spontaneous down-conversion

We have measured sub-shot-noise quantum correlations of spatial fluctuations in the far-field image of the parametric fluorescence created in a type I {beta}-barium-borate nonlinear crystal, either between opposite angular sectors (nondegenerate configuration) or between opposite pixels (degenerate configuration). Imaging is performed at a very low light level (0.2 photons per pixel) with an electron-multiplying CCD camera, resulting in purely spatial coincidences between single photons when detecting on pixels. Experimental results overcome the standard quantum-limit-shot-noise level without subtraction of the variance of the detection noise. We compare these experimental results with numerical results given by the quantum Green's function method, which is proved to have strong advantages over stochastic simulations.

74 ATOMIC AND MOLECULAR PHYSICS↗

Radiometric calibration and SNR calculation of a SWIR imaging telescope

Radiometric calibration of an imaging telescope is usually made using a uniform illumination sphere in a laboratory. In this study, we used the open-sky images taken during bright day conditions to calibrate our telescope. We found a dark signal offset value and a linear response coefficient value for each pixel by using three different algorithms. Then we applied these coefficients to the taken images, and considerably lowered the image non-uniformity. Calibration can be repeated during the operation of telescope with an object that has better uniformity than open-sky. Also SNR (Signal to Noise Ratio) of each pixel was calculated from the open-sky images using the temporal mean and standard deviations. It is found that SNR is greater than 80 for all pixels even at low light levels.

79 ASTRONOMY AND ASTROPHYSICS↗

Engineering the gain-bandwidth product of phototransistor diodes

In recent years, phototransistors have considerably expanded their field of application, including for instance heterodyne detection and optical interconnects. Unlike in low-light imaging, some of these applications require fast photodetectors that can operate in relatively high light levels. Since the gain and bandwidth of phototransistors are not constant across different optical powers, the devices that have been optimized for operation in low light level cannot effectively be employed in different technological applications. We present an extensive study of the gain and bandwidth of short-wavelength infrared phototransistors as a function of optical power level for three device architectures that we designed and fabricated. The gain of the photodetectors is found to increase with increasing carrier injection. Based on a Shockley-Read-Hall recombination model, we show that this is due to the saturation of recombination centers in the phototransistor base layer. Eventually, at a higher light level, the gain drops, due to the Kirk effect. As a result of these opposing mechanisms, the gain-bandwidth product is peaked at a given power level, which depends on the device design and material parameters, such as doping and defect density. Guided by this physical understanding, we design and demonstrate a phototransistor which is capable of reaching a high gain-bandwidth product for high-speed applications. The proposed design criteria can be employed in conjunction with the engineering of the device size to achieve a wide tunability of the gain and bandwidth, hence paving the way toward fast photodetectors for applications with different light levels.

Bianconi, Simone (ORCID:0000000238286513)↗

Fast quantum ghost imaging with a single-photon-sensitive time-stamping camera

Quantum ghost imaging (QGI) leverages correlations between entangled photon pairs to reconstruct an image using light that has never physically interacted with an object. Despite extensive research interest, this technique has long been hindered by slow acquisition speeds, due to the use of raster-scanned detectors or the slow response of intensified cameras. Here, we utilize a single-photon-sensitive time-stamping camera to perform QGI at ultra-low-light levels with rapid data acquisition and processing times, achieving high-resolution and high-contrast images in under 1 min. Our work addresses the trade-off between image quality, optical power, data acquisition time, and data processing time in QGI, paving the way for practical applications in biomedical and quantum-secured imaging.

Mavian, Alex (ORCID:0000000279448830)↗

Development of a directly driven multi-shell platform: Laser drive energetics

Simulations predict that directly driven multi-shell targets can provide a robust alternative to conventional high-convergence implosion concepts by coupling two to three times more energy into the final igniting thermonuclear fuel assembly than indirect-drive concepts. The three-shell directly driven Revolver concept [K. Molvig, M. J. Schmitt, B. J. Albright, E.S. Dodd, N.M. Hoffman, G.H. McCall, and S.D. Ramsey, Phys. Rev. Lett. 116, 255003 (2016)] utilizes a design that maximizes laser energy conversion into inward kinetic energy of the outermost ablator shell (~9%) while minimizing the DT fuel convergence (~9) to reduce the mixing of material from the innermost shell into the fuel. Inherent in this design concept is the use of 192 narrow beams (with a 1/e laser beam-to-capsule diameter ratio of 0.33) from the National Ignition Facility laser pointed in a polar direct drive laser configuration. In this paper, we demonstrate that low average laser intensity at the capsule surface (≤300 TW/cm 2 ) limits the measured laser backscatter, indicating that a greater amount of laser energy is coupled into the target. Omega experiments have been performed to determine the coupling of laser energy to the outermost shell of a scaled Revolver target (i.e., the ablator shell) by measuring capsule implosion trajectories and scattered-light fractions for two different drive configurations. Comparisons of simulated shell trajectory and velocity profiles with experimental data obtained from self-emission images show good agreement and are consistent with measured scattered light data. Furthermore, the low levels of scattered light measured are consistent with post-shot simulation results that show high hydro-coupling efficiency. These results strengthen the case for using narrow beams at low intensity to drive large ablator capsules for future direct-drive, multi-shell ignition concepts.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Nonlocal atlas-guided multi-channel forest learning for human brain labeling

Purpose: It is important for many quantitative brain studies to label meaningful anatomical regions in MR brain images. However, due to high complexity of brain structures and ambiguous boundaries between different anatomical regions, the anatomical labeling of MR brain images is still quite a challenging task. In many existing label fusion methods, appearance information is widely used. However, since local anatomy in the human brain is often complex, the appearance information alone is limited in characterizing each image point, especially for identifying the same anatomical structure across different subjects. Recent progress in computer vision suggests that the context features can be very useful in identifying an object from a complex scene. In light of this, the authors propose a novel learning-based label fusion method by using both low-level appearance features (computed from the target image) and high-level context features (computed from warped atlases or tentative labeling maps of the target image). Methods: In particular, the authors employ a multi-channel random forest to learn the nonlinear relationship between these hybrid features and target labels (i.e., corresponding to certain anatomical structures). Specifically, at each of the iterations, the random forest will output tentative labeling maps of the target image, from which the authors compute spatial label context features and then use in combination with original appearance features of the target image to refine the labeling. Moreover, to accommodate the high inter-subject variations, the authors further extend their learning-based label fusion to a multi-atlas scenario, i.e., they train a random forest for each atlas and then obtain the final labeling result according to the consensus of results from all atlases. Results: The authors have comprehensively evaluated their method on both public LONI-LBPA40 and IXI datasets. To quantitatively evaluate the labeling accuracy, the authors use the dice similarity coefficient to measure the overlap degree. Their method achieves average overlaps of 82.56% on 54 regions of interest (ROIs) and 79.78% on 80 ROIs, respectively, which significantly outperform the baseline method (random forests), with the average overlaps of 72.48% on 54 ROIs and 72.09% on 80 ROIs, respectively. Conclusions: The proposed methods have achieved the highest labeling accuracy, compared to several state-of-the-art methods in the literature.

61 RADIATION PROTECTION AND DOSIMETRY↗

Video-rate Raman-based metabolic imaging by Airy light-sheet illumination and photon-sparse detection

Despite its massive potential, Raman imaging represents just a modest fraction of all research and clinical microscopy to date. This is due to the ultralow Raman scattering cross-sections of most biomolecules that impose low-light or photon-sparse conditions. Bioimaging under such conditions is suboptimal, as it either results in ultralow frame rates or requires increased levels of irradiance. Here, we overcome this tradeoff by introducing Raman imaging that operates at both video rates and 1,000-fold lower irradiance than state-of-the-art methods. To accomplish this, we deployed a judicially designed Airy light-sheet microscope to efficiently image large specimen regions. Further, we implemented subphoton per pixel image acquisition and reconstruction to confront issues arising from photon sparsity at just millisecond integrations. We demonstrate the versatility of our approach by imaging a variety of samples, including the three-dimensional (3D) metabolic activity of single microbial cells and the underlying cell-to-cell variability. To image such small-scale targets, we again harnessed photon sparsity to increase magnification without a field-of-view penalty, thus, overcoming another key limitation in modern light-sheet microscopy.

60 APPLIED LIFE SCIENCES↗

Entangled Photon Spectroscopy

Conspectus The enhanced interest in quantum-related phenomena has provided new opportunities for chemists to push the limits of detection and analysis of chemical processes. As some have called this the second quantum revolution, a time has come to apply the rules learned from previous research in quantum phenomena toward new methods and technologies important to chemists. While there has been great interest recently in quantum information science (QIS), the quest to understand how nonclassical states of light interact with matter has been ongoing for more than two decades. Our entry into this field started around this time with the use of materials to produce nonclassical states of light. Here, the process of multiphoton absorption led to photon-number squeezed states of light, where the photon statistics are sub-Poissonian. In addition to the great interest in generating squeezed states of light, there was also interest in the formation of entangled states of light. While much of the effort is still in foundational physics, there are numerous new avenues as to how quantum entanglement can be applied to spectroscopy, imaging, and sensing. These opportunities could have a large impact on the chemical community for a broad spectrum of applications. Here, we discuss the use of entangled (or quantum) light for spectroscopy as well as applications in microscopy and interferometry. The potential benefits of the use of quantum light are discussed in detail. From the first experiments in porphyrin dendrimer systems by Dr. Dong-Ik Lee in our group to the measurements of the entangled two photon absorption cross sections of biological systems such as flavoproteins, the usefulness of entangled light for spectroscopy has been illustrated. These early measurements led the way to more advanced measurements of the unique characteristics of both entangled light and the entangled photon absorption cross-section, which provides new control knobs for manipulating excited states in molecules. The first reports of fluorescence-induced entangled processes were in organic chromophores where the entangled photon cross-section was measured. These results would later have widespread impact in applications such as entangled two-photon microscopy. From our design, construction and implementation of a quantum entangled photon excited microscope, important imaging capabilities were achieved at an unprecedented low excitation intensity of 10 7 photons/s, which is 6 orders of magnitude lower than the excitation level for the classical two-photon image. New reports have also illustrated an advantage of nonclassical light in Raman imaging as well. From a standpoint of more precise measurements, the use of entangled photons in quantum interferometry may offer new opportunities for chemistry research. Experiments that combine molecular spectroscopy and quantum interferometry, by utilizing the correlations of entangled photons in a Hong–Ou–Mandel (HOM) interferometer, have been carried out. The initial experiment showed that the HOM signal is sensitive to the presence of a resonant organic sample placed in one arm of the interferometer. In addition, parameters such as the dephasing time have been obtained with the opportunity for even more advanced phenomenology in the future.

36 MATERIALS SCIENCE↗

Nondestructive Characterization and Accelerated UV Testing of Browned Field-Aged PV Modules

Encapsulant browning is one of the most common degradation modes found in crystalline silicon field-aged photovoltaic modules. Browning, usually undetected unless severe, reduces the short-circuit current (Isc) produced by a module. Therefore, field-aged browned modules have been subjected to accelerated UV testing to obtain true end-of-life activation energy for the encapsulant browning mechanism. A novel time- and resource-saving accelerated UV exposure testing method simultaneously allowing multiple module temperatures to be maintained in a single chamber run is presented. Six field-aged crystalline silicon modules of glass/backsheet construction (three each from BP Solar/Solarex MSX 60 and Siemens M55) with similar glass and encapsulant formulation were exposed to a UV dosage of 450 kWh/m2 . Through passive heating, the average module temperatures for the BP Solar/Solarex modules were 60 degrees C, 77 degrees C, and 85 degrees C and those of Siemens M55 were 75 degrees C, 80 degrees C, and 837 degrees C. To study UV browning, the modules were intermittently characterized through visual imaging, UV fluorescence imaging, electroluminescence imaging, quantum efficiency measurements, module, and cell-level light I-V measurements. An Isc decrease corroborated the increased extent of browning with increased module temperature. For the BP Solar/Solarex modules, the Low T, Mid T, and the High T modules showed a 1.37%, 2.48%, and 3.26% Isc drop, respectively. The Siemens modules showed a 4.11%, 5.65%, and 6.95% Isc drop. The multiple cell-level Isc data points obtained for each module temperature increased provided statistical significance. Activation energy for encapsulant browning was calculated as 0.44 and 0.72 eV for MSX 60 and M55 modules, respectively.

14 SOLAR ENERGY↗

SU-C-201-04: Noise and Temporal Resolution in a Near Real-Time 3D Dosimeter

Purpose: To characterize the performance of a real-time three-dimensional scintillation dosimeter in terms of signal-to-noise ratio (SNR) and temporal resolution of 3D dose measurements. This study quantifies its efficiency in measuring low dose levels characteristic of EBRT dynamic treatments, and in reproducing field profiles for varying multileaf collimator (MLC) speeds. Methods: The dosimeter prototype uses a plenoptic camera to acquire continuous images of the light field emitted by a 10×10×10 cm{sup 3} plastic scintillator. Using EPID acquisitions, ray tracing-based iterative tomographic algorithms allow millimeter-sized reconstruction of relative 3D dose distributions. Measurements were taken at 6MV, 400 MU/min with the scintillator centered at the isocenter, first receiving doses from 1.4 to 30.6 cGy. Dynamic measurements were then performed by closing half of the MLCs at speeds of 0.67 to 2.5 cm/s, at 0° and 90° collimator angles. A reference static half-field was obtained for measured profile comparison. Results: The SNR steadily increases as a function of dose and reaches a clinically adequate plateau of 80 at 10 cGy. Below this, the decrease in light collected and increase in pixel noise diminishes the SNR; nonetheless, the EPID acquisitions and the voxel correlation employed in the reconstruction algorithms result in suitable SNR values (>75) even at low doses. For dynamic measurements at varying MLC speeds, central relative dose profiles are characterized by gradients at %D{sub 50} of 8.48 to 22.7 %/mm. These values converge towards the 32.8 %/mm-gradient measured for the static reference field profile, but are limited by the dosimeter’s current acquisition rate of 1Hz. Conclusion: This study emphasizes the efficiency of the 3D dose distribution reconstructions, while identifying limits of the current prototype’s temporal resolution in terms of dynamic EBRT parameters. This work paves the way for providing an optimized, second-generational real-time 3D scintillation dosimeter capable of highly efficient and precise dose measurements. The presenting author is financially supported by an Alexander-Graham Bell doctoral scholarship from the Natural Sciences and Engineering Research Council of Canada (NSERC).

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

APODIZED PUPIL LYOT CORONAGRAPHS FOR ARBITRARY APERTURES. IV. REDUCED INNER WORKING ANGLE AND INCREASED ROBUSTNESS TO LOW-ORDER ABERRATIONS

The Apodized Pupil Lyot Coronagraph (APLC) is a diffraction suppression system installed in the recently deployed instruments Palomar/P1640, Gemini/GPI, and VLT/SPHERE to allow direct imaging and spectroscopy of circumstellar environments. Using a prolate apodization, the current implementations offer raw contrasts down to 10{sup –7} at 0.2 arcsec from a star over a wide bandpass (20%), in the presence of central obstruction and struts, enabling the study of young or massive gaseous planets. Observations of older or lighter companions at smaller separations would require improvements in terms of the inner working angle (IWA) and contrast, but the methods originally used for these designs were not able to fully explore the parameter space. We propose a novel approach to improve the APLC performance. Our method relies on the linear properties of the coronagraphic electric field with the apodization at any wavelength to develop numerical solutions producing coronagraphic star images with high-contrast region in broadband light. We explore the parameter space by considering different aperture geometries, contrast levels, dark-zone sizes, bandpasses, and focal plane mask sizes. We present an application of these solutions to the case of Gemini/GPI with a design delivering a 10{sup –8} raw contrast at 0.19 arcsec and offering a significantly reduced sensitivity to low-order aberrations compared to the current implementation. Optimal solutions have also been found to reach 10{sup –10} contrast in broadband light regardless of the aperture shape, with effective IWA in the 2-3.5 λ/D range, therefore making the APLC a suitable option for the future exoplanet direct imagers on the ground or in space.

79 ASTRONOMY AND ASTROPHYSICS↗