Search NASA⌕ Search

SEARCH · Search NASA

Results for “low-grade heat”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

The levelized cost of exergy: a technoeconomic framework for energy system comparison

While the levelized costs of electricity and heat have been quantified before, these two metrics cannot be directly compared, due to the different exergy content of heat and work. To address this, we develop a levelized cost of exergy (LCOEx) framework that enables direct comparisons between energy sources and processes. We find that moderate- and high-grade heat have an LCOEx that is comparable to electricity (5–10 ¢ per kWh ex ), while low-grade heat sources have much higher LCOEx values (>50 ¢ per kWh ex ). The LCOEx of a system's output is affected by (i) the LCOEx of the system input, (ii) the CAPEX of the system, and (iii) the exergetic efficiency of the system. We use our framework to identify which processes are already achieved with relatively high cost effectiveness (production of fuels, hydrogen, and ammonia) and which have room for improvement (dehumidification, food production).

08 HYDROGEN↗

The Levelized Cost of Exergy Framework

Exergy is the amount of energy within a substance or within a transfer of energy that can be used to produce work or some other useful output when interacting with some reference environment. Two different energy systems that produce the same output with the same exergetic efficiency must necessarily have the same amount of exergy input, even if the amount of energy input to the two systems is vastly different. For example, a low-grade heat-driven desalination would require far more energy input than a reverse osmosis (RO) plant producing the same amount of water, but if their exergetic efficiencies were the same, they would require the same amount of exergy input. Thus, comparisons between different energy sources on the basis of energy is not always appropriate. Instead, a comparison on a per unit exergy basis provides more insight on the cost-effectiveness of different energy sources and systems. In this presentation, we describe a framework for analyzing the levelized cost of exergy (LCOEx) for both inputs and outputs of various energy systems. Our framework illustrates how the cost per unit exergy of a system's energy source, as well as the exergetic efficiency of the system, greatly affect the cost of the system output. We use the levelized cost of electricity as a benchmark value for LCOEx, due to electricity's ubiquity as an energy source, and because it is relatively inexpensive on a per unit exergy basis. The LCOEx of various heat sources are then compared to the LCOEx of electricity. Medium- and high-grade industrial heat (> 150 degrees C) produced by natural gas tends to have an LCOEx on par with electricity. This is due to the low cost of natural gas, as well as the high exergy content of heat at higher temperatures. Meanwhile, low-grade heat tends to be an expensive exergy source, owing to the low exergy content of the low-grade heat. We first apply our framework to desalination, where RO has come to dominate, due to the low LCOEx of the energy source (electricity) and relatively high exergetic efficiency of RO compared to thermal desalination systems. We then use this framework to highlight an opportunity for dehumidification systems to experience a similar cost improvement as desalination has. If an electrically-driven, high exergetic efficiency dehumidification system were developed (such as the membrane-based dehumidification systems proposed in literature), it would use a low cost exergy source with a high exergetic efficiency and could potentially lower the cost of dehumidification in the way that RO has done for desalination. Finally, we apply our framework to various fuels (natural gas, hydrogen, gasoline, etc.) and energy systems across different sectors (desalination, dehumidification, vehicles, etc.) to understand the variation in the cost of exergy input and exergetic efficiency of different systems and technologies.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Parametric optimization of PCM-enhanced underground thermal energy storage for buildings in moderate cold climates

This study presents a novel underground thermal energy storage (UTES) system designed for space heating in buildings located in moderate cold climates. The proposed UTES features a borehole with a depth of 25 ft. (7.62 m) and a diameter of 3 ft. (0.91 m), containing two helical pipe loops-one for discharge fluid and another for recharge fluid-and a thermally enhanced phase change material (PCM) layer that provides high energy storage capacity. The system requires daily thermal recharging using a low-grade heat source for a few hours and delivers continuous heating at a nearly constant discharge rate without significant performance degradation over a 24-h period. This study demonstrates that the optimized UTES, when recharged with hot fluid at an inlet temperature of 40 degrees C for 6 h daily, can provide a continuous heat discharge rate of approximately 2.9 kW for 24 h or 3.4 kW if operated under a shorter discharge period of 15 h (17:00-08:00). With a round-trip efficiency of 72-97%, the proposed UTES offers an efficient and reliable solution for short- and long-duration thermal energy storage technology, making it a promising technology for cold climates.

15 GEOTHERMAL ENERGY↗

Fundamental advantages of multijunction thermoradiative cells

Thermoradiative (TR) cells convert heat to work through emission of thermal radiation. Multijunction thermoradiative cells have received little research interest due to the apparent overlap with energy harvesting limits. Through detailed balance formalism, the present study models both single- and multi-diode TR devices, establishing their performance limits and identifying key factors that influence efficiency. For single-junction TR cells, we derive a relationship for the optimal bandgap and show that higher emitter temperatures increase efficiency. When the receiver is at absolute zero temperature, multijunction TR cells have little advantage over the single-junction cell in terms of the maximum output power density. However, for higher receiver temperatures, the multijunction configuration demonstrates significant improvements in both power and efficiency through the optimization of the chemical potential and bandgap of each diode in the complete ensemble. A 500 K emitter and 300 K receiver TR system can achieve a 21.25% increase in efficiency and a 10% improvement in the power density with multijunction architecture compared to a single junction through chemical potential optimization. These findings suggest that multijunction TR cells offer a promising approach to advancing low-grade heat recovery technologies for efficient heat-to-work conversion.

30 DIRECT ENERGY CONVERSION↗

Ultra-high efficiency hydrogen production using a large-scale solid oxide electrolysis cell system

Efficient and cost-effective production of clean hydrogen is key to decarbonizing the production of hard-to-abate industries, such as chemicals, fuels, steel, cement and many other commodities that form the basis of modern societies. High-temperature steam electrolysis (HTSE) has recently become commercially available and offers opportunities for producing hydrogen at higher efficiency and lower cost than competing low temperature technologies. In this work, we report world record setting hydrogen production efficiency from large-scale prototype HTSE systems based on solid oxide electrolysis cell (SOEC) technology. Independent tests performed at Idaho National Laboratory (INL) employed a Bloom Energy 100 kW SOEC system to achieve a hydrogen production direct current specific electric energy consumption as low as 36.7 kWh per kilogram of hydrogen. Remarkably, similar high efficiencies in the range of 36–39 kW/kg-H2 were obtained over a wide range of hydrogen production rates and even during dynamic ramping as the hydrogen production and electric power consumption of the system were varied between 20 % and 100 % of nominal conditions. Furthermore, these test results validate previous projections that commercial SOEC systems can produce clean hydrogen at efficiencies approaching 100 % for less than 2 U S. dollars per kilogram when located near sources of inexpensive, low-grade heat and clean electricity.

08 HYDROGEN↗

200 h of discharge cycling with an all-aqueous copper thermally regenerative ammonia battery

Thermally regenerative ammonia batteries (TRABs) offer an approach to energy storage and electricity generation by harnessing low-grade heat (T < 150 °C). A TRAB discharge resembles that of a flow battery, where electrochemical reactions produce electrical power from energy stored within aqueous electrolytes. While there are many types of TRABs, the all-aqueous copper TRAB (Cu aq -TRAB) has produced the largest power and energy storage densities. Despite many improvements to TRAB performance, most tests have only lasted a few hours, which are not representative of operation times expected of these devices. Herein, we operated a Cu aq -TRAB for 200 h of constant current discharging to assess battery performance and component stability. After 200 h of testing, the average power density increased slightly to 7.2 mW cm -2 , which was within 0.01 % of starting conditions. Likewise, the average energy density for the final cycle was only 0.03 % lower than the initial cycle. The overall insensitivity of the power cell to cycling represents a major milestone in the advancement of TRAB systems. In conclusion, energy dispersive X-ray spectroscopy provides evidence to suggest that these small changes in power and energy density are likely to the membrane acclimating to TRAB electrolytes.

25 ENERGY STORAGE↗

A Modelica Implementation of an Organic Rankine Cycle

Organic Rankine cycle (ORC) systems generate power from low-grade heat sources, such as geothermal sources and industrial waste heat. A key feature is that a working fluid is selected to match the temperature of the source. With the vast pool of candidate working fluids comes the challenge of developing a large number of robust thermodynamic media models. We implemented a subcritical ORC model in Modelica that uses working fluid data records and interpolation schemes in lieu of thermodynamic medium evaluation for energy recovery estimation. This is a component model that can be integrated into a larger energy system model. It does not require detailed thermodynamic, heat transfer, or machine analysis. Our ORC model fills a gap where working fluids are ready to choose or easy to add, and at the same time can be integrated into an energy system.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Solar house system interfaced with the power utility grid

Photovoltaic cells may be used to convert sunlight directly into electrical energy and into low-grade heat to be used for large scale terrestrial solar energy conversion. Both forms of energy can be utilized if such cells are deployed in close proximity to the consumer (rooftop). CdS/Cu2S solar cells are an example of cells which may be produced inexpensively enough to become economically attractive. Cell parameters relevant for combined solar conversion are presented. Critical issues, such as production yield, life expectancy, stability of performance, are discussed. Systems design parameters related to operating temperatures are analyzed. First results obtained on Solar One, the experimental solar house of the University of Delaware, are given. Economic aspects are discussed.

Boeer, K. W.↗

Application of Ibuprofen Sodium Dihydrate for Thermochemical Energy Storage

Thermochemical energy storage (TCES) offers a transformative approach to address grid instability by harnessing reversible chemical reactions for efficient heat storage and release. Here, we introduce pharmaceutical organic salt hydrates as a class of materials with exceptional performance for low-grade waste heat recovery. We demonstrate ibuprofen sodium dihydrate (ISD) as an example organic hydrate exhibiting a dehydration temperature range of 60-110 °C and a remarkable dehydration enthalpy of up to 59.5 kJ/mol of water, ideally suited for capturing industrial and residential waste heat. Using rigorous multimodal characterization, including thermogravimetric analysis, differential scanning calorimetry, in-situ FTIR, in-situ PXRD, and NMR, we demonstrate ISD's superior thermal, chemical, and structural stability over 150 hydration-dehydration cycles, achieving an unprecedented cycling efficiency of ~99.9%. Compared to conventional inorganic salt hydrates like strontium chloride hexahydrate and calcium oxalate monohydrate, ISD showcases enhanced durability without deliquescence or pulverization, even under high-humidity conditions. In-situ analyses confirm the transition from ISD to ibuprofen sodium anhydrous (ISA) proceeds with structural reorganization, thereby combining the dehydration mechanism with phase transitions, resulting in higher energy storage capacity. Microstructural analyses reveal that repeated water intercalation and structural transitions aid in creating significant porosity that enhances water transport kinetics, further improving the hydration/dehydration performance. By combining the phase change and chemical dehydration mechanisms, ISD paves the way for designing a new class of organic salt hydrates, offering tunable properties to meet diverse thermal energy storage demands and supporting sustainable grid resilience.

Thangaraj, Kavin C.↗

Case Study of Integrating High-Temperature Heat Pump with LiBr-H2O Absorption Chiller for Data Center Liquid Cooling

Data centers (DCs) are physical infrastructures that support artificial intelligence workloads. The rapid growth of artificial intelligence is putting substantial pressure on the US power grid. Most of electricity consumed by IT equipment, accounting for 50%-60% of total DC power, ultimately becomes waste heat. This heat is dissipated by DC’s cooling facilities, accounting for an additional 30%-40% of total DC power. Recovering and repurposing this waste heat offers a significant opportunity to enhance energy efficiency and reduce operating costs of DCs. One potential pathway is converting heat to cold using thermal-driven absorption chillers, therefore, reducing the power consumption in DC cooling facilities. Existing studies mainly demonstrate the technical and economic feasibility of repurposing DC’s waste heat for cooling applications but provide limited technical details on how to integrate the thermal-driven absorption chillers with DC cooling systems. In addition, the low-grade waste heat available from DCs must be upgraded to higher temperatures suitable for absorption chillers. This paper presents a case study on integrating high-temperature heat pumps with a LiBr-H2O absorption chiller to use DC waste heat for cooling. A thermodynamic model of single-effect, LiBr-H2O absorption chiller and an empirical model of high-temperature heat pumps were built. The case study considers ASHRAE W17 liquid-cooled DC, with facility service water supplied at 17.0℃ and returned at 25.3℃. The thermal behaviors of absorption chiller components were predicted for the generation temperature ranging from 75.0℃ to 115.0℃. Based on the available waste heat in the integrated system, two waste heat recovery strategies were evaluated: a facility service water-based strategy and cooling water-based strategy. Results indicated that the cooling water-based strategy achieves higher Coefficient of Performance (COPs) than the facility service water-based strategy. The relatively low cooling COPs of single-effect LiBr-H2O absorption chillers could be offset by high heating COP of high temperature heat pumps. The maximum cooling COP of absorption chiller and the overall COP of integrated systems occur at lower generation temperatures, but these conditions also yield lower cooling capacities. In practice, system operation should balance the trade-off between the COP and cooling capacity

Wang, Pengtao [ORNL] (ORCID:0000000214713429)↗

Building heating and cooling applications thermal energy storage program overview

Thermal energy storage technology and development of building heating and cooling applications in the residential and commercial sectors is outlined. Three elements are identified to undergo an applications assessment, technology development, and demonstration. Emphasis is given to utility load management thermal energy system application where the stress is on the 'customer side of the meter'. Thermal storage subsystems for space conditioning and conservation means of increased thermal mass within the building envelope and by means of low-grade waste heat recovery are covered.

Eissenberg, D. M.↗

NASA Thermal Recovery Energy Efficient System (TREES) for Aircraft Exergy Optimization

Future air vehicles will increasingly incorporate electrical powertrains that require very tight integration of power, propulsion, thermal, and airframe technologies. These complex and highly integrated sub-systems present a new exergy utilization and thermo-economics challenge due to the significant and highly distributed low-grade waste heat being produced. One system-wide solution is proposed that utilizes acoustic thermal energy conversion technologies to simultaneously provide thermal management and waste energy recycling for the entire vehicle. This system level solution serves to optimize aircraft exergy utilization.

Dyson, Rodger↗

Solid-State Exergy Optimized Electric Aircraft Thermal and Fault Management

Future air vehicles will increasingly incorporate electrical powertrains that require very tight system level integration of power, propulsion, thermal, fault protection, and airframe technologies. This paper provides an overview of a new category of thermal energy conversion technology that can be used to enable a fully solid-state integrated thermal and fault management electric aircraft protection system, while synergistically managing and recycling both the low-grade waste heat from electrical components and the high-grade waste heat from engine components. This is achieved with exergy amplification of the powertrain waste-heat, a new class of fast flight-weight breakers, new class of long variable conductance heat pipe with multiple switchable condensers, new class of turbofan integrated heat exchangers and a gradient-based powertrain system optimizer.

safety↗

Electric Aircraft Cooling with Bio-Inspired Exergy Management

Future air vehicles will increasingly incorporate electrical powertrains that require very tight system-level integration of power, propulsion, thermal, fault protection, and airframe technologies. This chapter provides an overview of a new category of thermal energy conversion technology and describes the development of the resulting Thermal Recovery Exergy Efficient System, TREES. TREES can be used to enable a fully solid-state integrated thermal and fault management electric aircraft protection system, while synergistically managing and recycling both the low-grade waste heat from electrical components and the high-grade waste heat from engine components. This is achieved with exergy amplification of the powertrain waste heat, a new class of fast flight-weight breakers, a new class of long variable-conductance heat pipes with multiple switchable condensers, a new class of turbofan-integrated heat exchangers, and a gradient-based powertrain system optimizer. This approach is like the human body’s thermal management system in which the heart, arteries, and veins are analogous to the turbofan, acoustic tubes, and heat pipes proposed herein.

Rodger W Dyson↗

Thermal Management Ideas and Challenges

Thermal management is a challenge for electric aircraft propulsion. This is because Current electrified aircraft concepts produce large amounts of low-grade waste heat and require large, heavy thermal management systems that cause drag. Currently, NASA is considering passive approaches for the X-57 and HEATheR projects to reduce these penalties.

Electric Aircraft↗

HEATheR: High-efficiency Electric Aircraft Thermal Research

Thermal management is a challenge for electric aircraft propulsion. This is because Current electrified aircraft concepts produce large amounts of low-grade waste heat and require large, heavy thermal management systems that cause drag. The High-efficiency Electric Aircraft Thermal Research project explored two ideas to solve this problem: building a low loss power system and using the aircraft skin to cool components through the outer mold line.

electric aircraft↗

Thermomagnetic generators for ultra-low-grade marine thermal energy harvesting

Low-grade thermal gradients in marine environments represent an underexploited energy source for autonomous sensing and monitoring. Converting such small temperature differences into usable electrical power remains a key challenge for ocean-deployed systems. We present a deployable thermomagnetic generator thoroughly characterized for marine-relevant energy harvesting. The device powers an internet-connected sensor and harvests ultra-low temperature differences akin to those at the ocean surface. It draws heat from water and rejects it to ambient air, operating optimally at a temperature difference (ΔT) of ~7.5 °C. Laboratory prototypes generated up to 6.7 mW at ΔT ~ 10 °C with gentle airflow (~1 m s -1 ). A separate controlled wave-tank demonstration validated stable operation and sensor powering under marine-like boundary conditions. Given its voltage and power margins, the generator could sustain multiple sensor nodes. Scalability and material assessments identify modular deployment and non-rare-earth alternatives as pathways toward practical marine energy harvesting and low-grade waste-heat recovery.

16 TIDAL AND WAVE POWER↗

Excess fission xenon at Apollo 16

Results are reported of stepwise heating analyses of Xe and Kr in four Apollo 16 low-grade breccias: 60019, 60225, 60275, and 67455. All four samples contain significant amounts of solar wind gases and at least three contain excess fission Xe. This observation indicates that the excess fission Xe effect is global rather than local, i.e., results from moon-wide redistribution of fission Xe rather than local redistribution in KREEP-rich Apollo 14 material. It is suggested that the excess fission Xe phenomenon represents a temporal variation in the amount of fission Xe available for redistribution, that it is prominent in samples from both highland sites simply because they are older than mare sites, and that samples from these sites had experienced at least some of their surface exposure at an early epoch.

Bernatowicz, T. J.↗