Search NASA⌕ Search

SEARCH · Search NASA

Results for “low-mass WIMPs”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Search for low-mass WIMPs in a 0.6 kg day exposure of the DAMIC experiment at SNOLAB

In this paper, we present results of a dark matter search performed with a 0.6 kg d exposure of the DAMIC experiment at the SNOLAB underground laboratory. We measure the energy spectrum of ionization events in the bulk silicon of charge-coupled devices down to a signal of 60 eV electron equivalent. The data are consistent with radiogenic backgrounds, and constraints on the spin-independent WIMP-nucleon elastic-scattering cross section are accordingly placed. A region of parameter space relevant to the potential signal from the CDMS-II Si experiment is excluded using the same target for the first time. This result obtained with a limited exposure demonstrates the potential to explore the low-mass WIMP region (<10 GeV c -2 ) with the upcoming DAMIC100, a 100 g detector currently being installed in SNOLAB.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Sensitivity to low-mass WIMPs with an improved liquid argon ionization response model within the DarkSide program

Dark matter detection experiments using liquid argon rely on a precise characterization of the ionization response to nuclear recoils, especially in the keV energy range relevant for light dark matter interactions. In this work, we present a comprehensive analysis that combines new measurements from the ReD setup, part of the DarkSide experimental program, with calibration data from DarkSide-50, as well as results from the ARIS and SCENE experiments. These combined datasets enable improved constraints on atomic screening effects in the modeling of the ionization response of liquid argon to nuclear recoils. The analysis is performed within the Thomas-Imel recombination framework adopted in previous DarkSide studies, and is here further constrained by the inclusion of ReD data, which allow the screening function to be determined from calibration measurements. By including the updated ionization model into the DarkSide-50 analysis framework, we obtain stronger exclusion limits on low-mass weakly interacting massive particle (WIMP) interactions, setting new world-leading constraints in the 1 – 3 GeV / c 2 WIMP mass range. Finally, we recast the sensitivity projections for the upcoming DarkSide-20k detector, demonstrating a significantly enhanced discovery potential for low-mass dark matter candidates.

Acerbi, F. [Fond. Bruno Kessler, Trento]↗

Paleo-detectors: Searching for dark matter with ancient minerals

We explore paleo-detectors as an approach to the direct detection of weakly interacting massive particle (WIMP) dark matter radically different from conventional detectors. Instead of instrumenting a (large) target mass in a laboratory in order to observe WIMP-induced nuclear recoils in real time, the approach is to examine ancient minerals for traces of WIMP-nucleus interactions recorded over timescales as large as 1 Gyr. Here, we discuss the paleo-detector proposal in detail, including background sources and possible target materials. In order to suppress backgrounds induced by radioactive contaminants such as uranium, we propose to use minerals found in marine evaporites or in ultrabasic rocks. Here, we estimate the sensitivity of paleo-detectors to spin-independent and spin-dependent WIMP-nucleus interactions. The sensitivity to low-mass WIMPs with masses m χ ≲ 10 GeV extends to WIMP-nucleon cross sections many orders of magnitude smaller than current upper limits. Lastly, for heavier WIMPs with masses m χ ≳ 30 GeV cross sections a factor of a few to ~100 smaller than current upper limits can be probed by paleo-detectors.

79 ASTRONOMY AND ASTROPHYSICS↗

Direct Detection of Dark Matter at the University of South Dakota

The grant supports experimental research to address one of the pressing questions of our time is the nature and composition of the dark matter. Direct detection of dark matter is possible because the rotation curves of galaxies suggest the presence of a sufficiently-large weakly interacting massive particle (WIMP) density. However, the absence of any confirmed dark matter detection indicates the need for more sensitive experiments. SuperCDMS SNOLAB is a generation-2 dark matter search experiment that is designed to have vastly improved sensitivity to low-mass WIMPs. SuperCDMS SNOLAB unique capabilities also enable sensitivity to a broader range of science beyond WIMPs. The SuperCDMS SNOLAB experiment is being installed and integrated at SNOLAB, near Sudbury, Ontario in Canada. The University of South Dakota (USD) group is deeply invested in the installation, integration and planning for commissioning and operations of the SuperCDMS SNOLAB experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SuperCDMS Prototype Detector Design and Testing

A substantial amount of astrophysical evidence indicates that approximately a quarter of all energy in the universe is composed of a nonluminous, and nonbaryonic \dark" matter. Of the potential dark matter particle candidates, Weakly Interacting Massive Particles, or WIMPs, is particularly well motivated. As a means to directly detect WIMP interactions with baryonic matter, the Cryogenic Dark Matter Search (CDMS) project was established, operating at the Soudan Underground Laboratory from 2003 - 2015, under the CDMS II and SuperCDMS Soudan experiments. CDMS detectors simultaneously measure the ionization and phonon energies of recoil events in Si and Ge crystals kept at cryogenic temperatures in a low-background environment. The ratio of ionization energy to recoil energy serves as a discrimination parameter to separate nuclear recoil events from the electron-recoil background. The next installation, SuperCDMS SNOLAB, is preparing for future operation, with an initial payload of eighteen Ge and six Si, 100 mm diameter, 33 mm thick detectors. Of this initial payload, eight Ge and four Si detectors will operate in a high-voltage ( 100 V) mode, which have an increased sensitivity to low-mass WIMPs due to decreased energy thresholds. The SuperCDMS test facility at University of Minnesota aids in the detector R&D and characterization of prototype detectors, as part of the scale-up eort for Super- CDMS SNOLAB. This thesis presents the rst full ionization and phonon characterization study of a 100 mm diameter, 33 mm thick prototype Ge detector with interleaved phonon and ionization channels. Measurements include ionization collection eciency, surface event rejection capabilities, and successful demonstration of nuclear recoil event discrimination. Results indicate that 100 mm diameter, interleaved Ge detectors show potential for use in SuperCDMS SNOLAB. As part of detector R&D, the Minnesota test facility also looks beyond the next stage of SuperCDMS, investigating larger individual detectors as a means to easily scale up the sensitive mass of future searches. This thesis presents the design and initial testing results of a prototype 150 mm diameter, 33 mm thick silicon ionization detector, which is 5.2 times larger than those used in SuperCDMS at Soudan and 2.25 times larger than those planned for use at SuperCDMS SNOLAB. In addition, the detector was operated with contact-free ionization electrodes to minimize bias leakage currents, which can limit operation at high bias voltages. The results show promise for the operation of both large volume silicon detectors and contact-free ionization electrodes for scaling up detector mass and bias.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

DAMIC at SNOLAB

We introduce the fully-depleted charge-coupled device (CCD) as a particle detector. We demonstrate its low energy threshold operation, capable of detecting ionizing energy depositions in a single pixel down to 50 eV ee . We present results of energy calibrations from 0.3 keV ee to 60 ke Vee , showing that the CCD is a fully active detector with uniform energy response throughout the silicon target, good resolution (Fano ~0.16), and remarkable linear response to electron energy depositions. We show the capability of the CCD to localize the depth of particle interactions within the silicon target. We discuss the mode of operation and unique imaging capabilities of the CCD, and how they may be exploited to characterize and suppress backgrounds. We present the first results from the deployment of 250 μm thick CCDs in SNOLAB, a prototype for the upcoming DAMIC100. DAMIC100 will have a target mass of 0.1 kg and should be able to directly test the CDMS-Si signal within a year of operation.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Low-Mass Dark Matter Search Results and Radiogenic Backgrounds for the Cryogenic Dark Matter Search

An ever-increasing amount of evidence suggests that approximately one quarter of the energy in the universe is composed of some non-luminous, and hitherto unknown, “dark matter”. Physicists from numerous sub-fields have been working on and trying to solve the dark matter problem for decades. The common solution is the existence of some new type of elementary particle with particular focus on weakly interacting massive particles (WIMPs). One avenue of dark matter research is to create an extremely sensitive particle detector with the goal of directly observing the interaction of WIMPs with standard matter. The Cryogenic Dark Matter Search (CDMS) project operated at the Soudan Underground Laboratory from 2003–2015, under the CDMS II and SuperCDMS Soudan experiments, with this goal of directly detecting dark matter. The next installation, SuperCDMS SNOLAB, is planned for near-future operation. The reason the dark-matter particle has not yet been observed in traditional particle physics experiments is that it must have very small cross sections, thus making such interactions extremely rare. In order to identify these rare events in the presence of a background of known particles and interactions, direct detection experiments employ various types and amounts of shielding to prevent known backgrounds from reaching the instrumented detector(s). CDMS utilized various gamma and neutron shielding to such an effect that the shielding, and other experimental components, themselves were sources of background. These radiogenic backgrounds must be understood to have confidence in any WIMP-search result. For this dissertation, radiogenic background studies and estimates were performed for various analyses covering CDMS II, SuperCDMS Soudan, and SuperCDMS SNOLAB. Lower-mass dark matter t c2 inent in the past few years. The CDMS detectors can be operated in an alternative, higher-biased, mode v to decrease their energy thresholds and correspondingly increase their sensitivity to low-mass WIMPs. This is the CDMS low ionization threshold experiment (CDMSlite), which has pushed the frontier at lower WIMP masses. This dissertation describes the second run of CDMSlite at Soudan: its hardware, operations, analysis, and results. The results include new WIMP mass-cross section upper limits on the spin-independent and spin-dependent WIMP-nucleon interactions. Thanks to the lower background and threshold in this run compared to the first CDMSlite run, these limits are the most sensitive in the world below WIMP masses of ⇠4 GeV/c2. This demonstrates also the great promise and utility of the high-voltage operating mode in the SuperCDMS SNOLAB experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low-mass dark matter search with CDMSlite

The SuperCDMS experiment is designed to directly detect WIMPs (Weakly Interacting Massive Particles) that may constitute the dark matter in our galaxy. During its operation at the Soudan Underground Laboratory, germanium detectors were run in the CDMSlite (Cryogenic Dark Matter Search low ionization threshold experiment) mode to gather data sets with sensitivity specifically for WIMPs with masses ${<}10$ GeV/$c^2$. In this mode, a large detector-bias voltage is applied to amplify the phonon signals produced by drifting charges. This paper presents studies of the experimental noise and its effect on the achievable energy threshold, which is demonstrated to be as low as 56 eV$_{\text{ee}}$ (electron equivalent energy). The detector biasing configuration is described in detail, with analysis corrections for voltage variations to the level of a few percent. Detailed studies of the electric-field geometry, and the resulting successful development of a fiducial parameter, eliminate poorly measured events, yielding an energy resolution ranging from ${\sim}$9 eV$_{\text{ee}}$ at 0 keV to 101 eV$_{\text{ee}}$ at ${\sim}$10 keV$_{\text{ee}}$. New results are derived for astrophysical uncertainties relevant to the WIMP-search limits, specifically examining how they are affected by variations in the most probable WIMP velocity and the galactic escape velocity. These variations become more important for WIMP masses below 10 GeV/$c^2$. Finally, new limits on spin-dependent low-mass WIMP-nucleon interactions are derived, with new parameter space excluded for WIMP masses ${\lesssim}$3 GeV/$c^2$.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Travel for SuperCDMS SNOLAB Operations (Final Technical Report)

The grant supported SuperCDMS SNOLAB experimental research to address the nature and composition of the dark matter. SuperCDMS SNOLAB is a generation-2 dark matter search experiment that is designed to have vastly improved sensitivity to low-mass weakly interacting massive particles (WIMPs). SuperCDMS SNOLAB unique capabilities also enable sensitivity to a broader range of science beyond WIMPs. The SuperCDMS SNOLAB experiment is being installed and integrated at SNOLAB, near Sudbury, Ontario in Canada. The scope of this grant was support of SuperCDMS members to travel to the experiment location to engage in installation, integration and operations of the SuperCDMS experiment.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Low-mass Dark Matter Search with the DarkSide-50 Experiment

We present the results of a search for dark matter WIMPs in the mass range below 20 GeV/c^2 using a target of low-radioactivity argon. The data were obtained using the DarkSide-50 apparatus at Laboratori Nazionali del Gran Sasso (LNGS). The analysis is based on the ionization signal, for which the DarkSide-50 time projection chamber is fully efficient at 0.1 keVee. The observed rate in the detector at 0.5 keVee is about 1.5 events/keVee/kg/day and is almost entirely accounted for by known background sources. We obtain a 90% C.L. exclusion limit above 1.8 GeV/c^2 for the spin-independent cross section of dark matter WIMPs on nucleons, extending the exclusion region for dark matter below previous limits in the range 1.8-6 GeV/c^2.

Agnes, P↗

Results on low-mass weakly interacting massive particles from an 11 kg d target exposure of DAMIC at SNOLAB

We present constraints on the existence of weakly interacting massive particles (WIMPs) from a 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An excess of ionization events is observed above the analysis threshold of 50 eV$_{\rm ee}$. While the origin of this low-energy excess requires further investigation, our data exclude spin-independent WIMP-nucleon scattering cross sections $\sigma_{\chi-n}$ as low as $3\times 10^{-41}$ cm$^2$ for WIMPs with masses $m_{\chi}$ from 7 to 10 GeV$c^{-2}$ . These results are the strongest constraints from a silicon target on the existence of WIMPs with $m_{\chi}$$<$9 GeV$c^{-2}$ and are directly relevant to any dark matter interpretation of the excess of nuclear-recoil events observed by the CDMS silicon experiment in 2013.

WIMP search, Dark Matter, DAMIC, SNOLAB↗

Results on low-mass weakly interacting massive particles from a 11 kg-day target exposure of DAMIC at SNOLAB

We present constraints on the existence of weakly interacting massive particles (WIMPs) from a 11 kg-day target exposure of the DAMIC experiment at the SNOLAB underground laboratory. The observed energy spectrum and spatial distribution of ionization events with electron-equivalent energies $>$200 eV$_{\rm ee}$ in the DAMIC CCDs are consistent with backgrounds from natural radioactivity. An excess of ionization events is observed above the analysis threshold of 50 eV$_{\rm ee}$. While the origin of this low-energy excess requires further investigation, our data exclude spin-independent WIMP-nucleon scattering cross sections $\sigma_{\chi-n}$ as low as $3\times 10^{-41}$ cm$^2$ for WIMPs with masses $m_{\chi}$ from 7 to 10 GeV$c^{-2}$ . These results are the strongest constraints from a silicon target on the existence of WIMPs with $m_{\chi}$$<$9 GeV$c^{-2}$ and are directly relevant to any dark matter interpretation of the excess of nuclear-recoil events observed by the CDMS silicon experiment in 2013.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

SuperCDMS Background Models for Low-Mass Dark Matter Searches

An abundance of astrophysical and cosmological evidence indicates the existence of a non-luminous, non-baryonic form of matter, called dark matter, that is approximately a quarter of all energy in the universe. One promising candidate for dark matter is the Weakly Interacting Massive Particle (WIMP) which interacts with baryonic matter at most on the scale of the weak force. The Cryogenic Dark Matter Search (CDMS) experiment aims to detect the nuclear recoils induced by the elastic scattering of WIMPs off of germanium nuclei. This is a rare signal and difficult to detect, especially the low-energy recoils that are produced by low-mass dark matter. The CDMS project operated at the Soudan Underground Laboratory from 2003--2015, with an upgrade to the SuperCDMS experiment in 2012. The germanium detectors were operated at 50~mK and able to measure both the ionization and athermal phonons produced in a particle interaction. Measuring two signals enables discrimination between electron recoil and nuclear recoil events. An alternative operating mode for the detectors is called the CDMS low ionization threshold experiment (CDMSlite), where a higher bias was applied to the detectors and only the phonon signal analyzed. This method increased sensitivity to low-mass dark matter interactions, but sacrificed discrimination capability. The CDMSlite spectrum had a large contribution from electron recoil background events. From the information gained during the first two CDMSlite Runs, a background model was developed for the third and final CDMSlite Run. Analytical descriptions were identified for those backgrounds that were theoretically known, e.g. tritium $\beta$-spectrum, and Geant simulations were used to understand and predict the low-energy spectra from other sources, e.g. Compton scattering. Multiple new models were developed for detectors operated in CDMSlite at Soudan. These include the analytical formula for Compton scattering, and empirical models for surface backgrounds from $^{210}$Pb contamination of the germanium crystals and detector housing. In order to accurately describe the surface events, a new detector response function was developed that included information about the electric field and energy resolution of the detector. These models were essential to the implementation of a profile likelihood analysis of the CDMSlite Run 3 data, which improved on the sensitivity to dark matter over the Run 2 optimum interval analysis for WIMP masses above 2.5~GeV/$c^2$. This demonstrated a successful application of a likelihood analysis to the high-voltage operating mode, and the potential for these analyses in the future SuperCDMS SNOLAB experiment. For the SuperCDMS SNOLAB experiment, the change in background rates from radiogenic neutrons was considered as additional towers of detectors were added, and the feasibility of an active neutron veto as a potential upgrade for large payloads was studied. This veto could be constructed of plastic scintillator with layers of gadolinium resin, and would aid in reducing the nuclear recoil single scatter background that is indistinguishable from the WIMP signal.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Nuclear recoil response of liquid xenon and its impact on solar 8B neutrino and dark matter searches

Knowledge of the ionization and scintillation responses of liquid xenon (LXe) to nuclear recoils is crucial for LXe-based dark matter experiments. Current calibrations carry large uncertainties in the low-energy region below ∼3 keV nr where signals from dark matter particles of <10 GeV/c 2 masses are expected. The coherent elastic neutrino-nucleus scattering (CE ν NS) by solar 8 B neutrinos also results in a continuum of nuclear recoil events below 3.0 keV nr (99% of events), which further complicates low-mass dark matter searches in LXe experiments. In this paper, we describe a method to quantify the uncertainties of low-energy LXe responses using published calibration data, followed by case studies to evaluate the impact of yield uncertainties on 8 B searches and low-mass dark matter sensitivity in a typical ton-scale LXe experiment. We conclude that naively omitting yield uncertainties leads to overly optimistic limits by factor ∼2 for a 6 GeV WIMP mass. Future nuclear recoil light yield calibrations could allow experiments to recover this sensitivity and also improve the accuracy of solar 8 B flux measurements.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

An Indirect Search for Weakly Interacting Massive Particles in the Sun Using Upward-going Muons in NOvA

I present the first Dark Matter search results using the full data set collected with the upward-going muon trigger in NOvA. Weakly Interactive Massive Particles (WIMPs) are a theoretical non-baryonic form of Dark Matter. The nature of Dark Matter is one of the most exciting open questions in modern physics. Though its existence can be inferred by astrophysical evidence, its properties are not yet understood. If we assume that Dark Matter particles can produce Standard Model particles through their interactions, an indirect search can help shed light on this mystery.The NOvA collaboration has built a 14 kton, fine-grained, low-Z, total absorption tracking calorimeter at an off-axis angle to the NuMI neutrino beam. Even though the detector is optimized to observe electron neutrino appearance from a muon neutrino beam, it has a unique potential for more exotic searches given its excellent granularity and energy resolution and relatively low-energy neutrino thresholds. In fact, with an efficient upward-going muon trigger and sufficient background suppression offline, NOvA is capable of a competitive indirect Dark Matter search for low-mass WIMPs.The idea of the upward-going muon trigger is first to select high-quality muon tracks, then use the timing information of all of the hits of each track to estimate directionality. In this way, the background flux is suppressed by more than a factor of 10^5 at trigger level to a rate of approximately 1 Hz. To further optimize this search, we use only upward-going muons that point to the Sun, so our search occurs at night when the Sun is on the other side of the Earth. This strategy also allows us to use the time when the Sun is above the horizon as a control region to estimate the background. Ultimately, implementation of a cut based and maximum likelihood analysis provides a powerful tool for rejecting background and selecting a sample of neutrino-induced upward-going muons. The overall background rejection power achieved by the analysis is substantial and impressive. Starting with approximately 150,000 events per second, we reduced it to 40 events per year. Since no statistically significant excess was found, a 90\% C.L. upper limit on the expected muon flux of upward-going muons has been set using the upper limit on the number of events given the number of observed events in the signal region. Lastly, by assuming the theory behind the upward-going muon flux, a limit on the WIMP-nucleon spin-dependent cross-section in the Sun was estimated. Although the limits on the spin-dependent cross-section do not appear to be competitive with previous indirect Dark Matter searches, the upward-going muon flux limits are promising. The upward-going muon flux limits could extend these results to a broader class of models that are not specific to the dark matter theory but produce upward-going muons, leading to competitive results.

Principato, Cristiana↗

Unidentified gamma-ray sources as targets for indirect dark matter detection with the Fermi -Large Area Telescope

We report that one of the predictions of the ΛCDM cosmological framework is the hierarchical formation of structure, giving rise to dark matter (DM) halos and subhalos. When the latter are massive enough they retain gas (i.e., baryons) and become visible. This is the case of the dwarf satellite galaxies in the Milky Way (MW) . Below a certain mass, halos may not accumulate significant amounts of baryons and remain completely dark. However, if DM particles are Weakly Interacting Massive Particles (WIMPs), we expect them to annihilate in subhalos, producing gamma rays which can be detected with the Fermi satellite. Using the three most recent point-source Fermi Large Area Telescope (LAT) catalogs (3FGL, 2FHL and 3FHL), we search for DM subhalo candidates among the unidentified sources, i.e., sources with no firm association to a known astrophysical object. We apply several selection criteria based on the expected properties of the DM-induced emission from subhalos, which allow us to significantly reduce the list of potential candidates. Then, by characterizing the minimum detection flux of the instrument and comparing our sample to predictions from the Via Lactea II (VL-II) N-body cosmological simulation, we place conservative and robust constraints on the $\langle$σ v$\rangle$-m DM parameter space. For annihilation via the τ + τ - channel, we put an upper limit of 4 × 10 -26 (5 × 10 -25 ) cm 3 s -1 for a mass of 10 (100) GeV . A critical improvement over previous treatments is the repopulation we made to include low-mass subhalos below the VL\nobreakdash-II mass resolution. Finally, with more advanced subhalo candidate filtering the sensitivity reach of our method can potentially improve these constraints by a factor 3 (2) for τ + τ - (b $\bar{b}$ ) channel.

79 ASTRONOMY AND ASTROPHYSICS↗

The Majorana Demonstrator readout electronics system

The M AJORANA D EMONSTRATOR comprises two arrays of high-purity germanium detectors constructed to search for neutrinoless double-beta decay in 76 Ge and other physics beyond the Standard Model. Its readout electronics were designed to have low electronic noise, and radioactive backgrounds were minimized by using low-mass components and low-radioactivity materials near the detectors. This paper provides a description of all components of the M AJORANA D EMONSTRATOR readout electronics, spanning the front-end electronics and internal cabling, back-end electronics, digitizer, and power supplies, along with the grounding scheme. The spectroscopic performance achieved with these readout electronics is also demonstrated.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗