Search NASA⌕ Search

SEARCH · Search NASA

Results for “low-temperature geothermal”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Low-Temperature Geothermal Resources: Relevant Data and PFA Methods to Reduce Development Risk: Preprint

This project is part of a larger national effort focused on demonstrating the multi-faceted value of integrating low-temperature geothermal resources into national decarbonization strategies and community energy plans. Low-temperature geothermal resources are defined as reservoirs-natural or engineered-with temperatures < 150 degrees C. While the focus in the NREL effort is on geothermal heating and cooling (GHC), resources at the upper end of this temperature range can also be used for small-scale power generation. However, low-temperature geothermal resources have not been studied as extensively as higher-temperature geothermal resources. We identified three major classes of low-temperature geothermal play types: sedimentary basins, orogenic systems, and radiogenic systems. We developed workflows for evaluating the potential of these resources building off the Play Fairway Analysis (PFA) approach to de-risking geothermal exploration. This PFA-based approach to low-temperature geothermal resources includes: (1) identifying relevant data; (2) grouping and weighting of relevant datasets into PFA criteria (e.g., geological, risk, economic criteria); (3) developing favorability or common risk maps for low-temperature geothermal resources to identify potential locations for more focused data collection; and (4) estimating electric power generation and heating potential at those locations using the GeoRePORT Resource Size Assessment Tool. This project will facilitate future deployment of GHC by providing data, tools, and workflows applicable to low-temperature geothermal resources.

favorability maps↗

Low-Temperature Geothermal Play Fairway Analysis for the Denver Basin

This project is part of a national initiative to showcase the benefits of incorporating low-temperature geothermal resource assessment into the deployment of geothermal heating, combined heat and power (CHP), and geothermal direct-use (GDU) technologies. The initiative was established to accelerate the country's decarbonization efforts by identifying potential for low-temperature geothermal resource utilization (<150 degrees C, e.g., CHP and GDU) in selected sedimentary basins with numerous population centers. The play fairway analysis (PFA) methodologies in this study were adapted from previous PFA investigations of sedimentary basin geothermal play types (SBGPTs) that evaluated the potential for low-temperature resources (<150 degrees C). Workflows, relevant datasets, a new Python library, and common and composite geological criteria maps are utilized to develop low-temperature geothermal resource favorability maps for the Denver Basin, a sedimentary basin spanning Colorado, Nebraska, and Wyoming. The replication of these methodologies in other SBGPTs can evaluate potential for low-temperature resources. To facilitate future assessment of low-temperature geothermal resources in SBGPTs, this project provides PFA workflows, data, tools, and favorability maps that will ultimately support the utilization of low-temperature geothermal resources in sedimentary basins.

combined heat and power↗

Low-Temperature Geothermal Play Fairway Analysis for the Denver Basin: Preprint

This project is part of a national initiative to showcase the benefits of incorporating low-temperature geothermal resource assessment into the deployment of geothermal heating and cooling (GHC), combined heat and power (CHP), and geothermal direct use (GDU) technologies. The initiative was established to accelerate the country's decarbonization efforts by identifying potential for low-temperature geothermal resource utilization (< 150 Degrees Celsius, i.e., GHC, CHP, and GDU) in selected sedimentary basins with numerous population centers. The Play Fairway Analysis (PFA) methodologies in this study were adapted from previous PFA investigations of sedimentary basin geothermal play types (SBGPTs) that evaluated the potential for low-temperature resources (< 150 Degrees Celsius). Workflows, relevant datasets, python code, common and composite geological criteria maps are utilized to develop low-temperature geothermal resource favorability maps for the Denver Basin, a sedimentary basin spanning Colorado, Nebraska, and Wyoming. The replication of these methodologies in other SBGPTs can evaluate potential for low-temperature resources. To facilitate future assessment of low-temperature geothermal resources in SBGPTs, this project provides PFA workflows, data, tools, and favorability maps that will ultimately support the utilization of low-temperature geothermal resources in sedimentary basins.

Denver Basin↗

Testing Various Cement Formulations under Temperature Cycles and Drying Shrinkage for Low-Temperature Geothermal Wells

Low-enthalpy geothermal wells are considered a sustainable energy source, particularly for district heating in the Netherlands. The cement sheath in these wells experiences thermal cycles. The stability of cement recipes under such conditions is not well understood. In this work, thermal cycling experiments for intermediate- and low-temperature geothermal well cements have been conducted. The samples were cured either under ambient conditions or under realistic pressure and temperature for 7 days. The samples did not show any signs of failure after performing 10 cycles of thermal treatment between 100 °C and 18 °C. We also tested cement formulations under drying conditions. Drying shrinkage is caused by a reduction in the water content of cement, which leads to capillary forces that can damage cement. Such circumstances lead to tensile stresses causing radial cracks. Most samples exhibited cracks under low humidity conditions (drying). Fiber reinforcement, especially using short PP fibers, improved the cement’s resilience to temperature and humidity changes. Such additives can improve the longevity of cement sheaths in geothermal wells.

36 MATERIALS SCIENCE↗

Evaluating the Impact of Redox Potential on the Corrosion of Q125, 316L, and C276 Steel in Low-Temperature Geothermal Systems

Time series experiments were used to explore the fluid redox impact on the corrosion of Q125, 316L, and C276 steels in low-ionic-strength and neutral water at temperature and pressure conditions associated with low-temperature geothermal systems. After exposing polished samples of each steel grade to an oxidizing (H2O2) and a reducing (Zn-doped) fluid for intervals of 24 h, 1 week, and 6 weeks, the atomic force microscopy results revealed general corrosion for Q125, while 316L and C276 exhibited pitting, crevice expansion, and edge attack corrosion. Secondary depositional features are frequently found as topographic highs, adjacent to pitting corrosion. These features may be identified as there is a very strong spatial correlation between the height retrace and phase retrace surface maps. All steels became progressively rougher over time after exposure to both fluids, while the corrosion rates were more complex. Samples exposed to the reducing fluid experienced an increase in the corrosion rate over time, while C276 and 316L experienced a decrease in the corrosion rate. Finally, a novel data validation technique was developed to address the intrinsic scalability of corrosion. The results indicate that the AFM scan area does not affect the measured surface roughness over nearly three orders of magnitude.

Bowman, Samuel (ORCID:000000021510174X)↗

Geothermal Play Fairway Analysis of Low-Temperature Resources for Sedimentary Basin Geothermal Play Types: An Example in the Denver Basin

This project is part of a nationwide effort to highlight the advantages of incorporating low-temperature geothermal resource evaluation into the implementation of combined heat and power (CHP), and geothermal direct use (GDU) technologies (e.g., space heating and/or cooling). The initiative aims to hasten the nation's decarbonization process by exploring the potential for using low-temperature geothermal resources (< 150 Degrees Celsius) in selected sedimentary basins that have several population centers. The Play Fairway Analysis (PFA) techniques were modified from earlier studies of sedimentary basin geothermal play types (SBGPTs) that assessed the viability of low-temperature resources. The decision-making process for leveraging low-temperature geothermal resources for GDU and CHP applications is complex and considers a variety of factors, including geological, economic, and risk criteria. This study covers workflows, relevant datasets, python code, and both common and composite maps used to create low-temperature geothermal resource favorability maps for the Denver Basin, which extends across Colorado, Nebraska, and Wyoming. The replication of these methodologies in other SBGPTs can evaluate potential for low-temperature resources. The proposed geothermal PFA approach for low-temperature geothermal resources includes: (1) identifying available relevant data and grouping data sets into PFA criteria (e.g., geological, economic, and risk criteria); (2) analyzing data gaps enable future focalized exploration; (3) performing uncertainty quantification; (4) weighting relevant data; (5) developing favorability and common risk maps for low-temperature geothermal resources to identify potential locations for more focused data collection. This project will facilitate future deployment of CHP and GDU by providing data, tools, and a workflow applicable to low-temperature geothermal resources in sedimentary basins.

15 GEOTHERMAL ENERGY↗

Techno-Economic Analysis of Greenfield Geothermal Hybrid Power Plants using a Solar or Natural Gas Steam Topping Cycle

The relatively low generation costs associated with wind, solar photovoltaic (PV), and natural-gas power plants make it challenging for geothermal power plants to produce and sell the power that has the reliability and sustainability characteristics that are greatly needed in U.S. power markets. This is especially true for geothermal resources with low-to-medium temperatures, which results in relatively low-thermal efficiency and generation costs that are higher than those for wind, solar PV, and natural gas. This analysis evaluates solar thermal- and natural-gas combustion waste heat recovery-based topping cycle hybridization of geothermal binary power plants. This approach provides several benefits that may allow geothermal power plants to generate power at more competitive costs. First, the addition of solar thermal energy or natural-gas combustion waste heat input to a geothermal power plant provides additional heat input that can be converted to electrical power. Second, the temperature level of the heat obtained from concentrating solar collectors or natural-gas combustion exhaust is higher than that of geothermal heat, which provides opportunities for improving the efficiency of the conversion of thermal energy to electrical power. Third, the ease with which solar thermal systems integrate with energy storage and the flexibility of natural gas means power generation can occur during peak demand periods. The hybrid cycles are compared to equivalently sized, co-located, independent geothermal, concentrating solar, and/or natural-gas power plants. The hybrid cycle tends to produce slightly more power than the standalone plants combined. However, the hybrid plant Levelized Cost of Energy (LCOE) is slightly higher than the LCOE of the combined standalone power plants for each of the case study locations investigated. Using the steam-topping cycle, organic Rankine cycle (ORC)-bottoming cycle hybrid plant design to combine a solar thermal resource and low- temperature geothermal resource (<120 degrees C) leads to a hybrid plant with a lower LCOE than a standalone geothermal-only system. Thus, hybrid plants may enable the economic development of geothermal resources in locations with low geothermal resource temperatures. However, in areas with higher geothermal resource temperatures (>120 degrees C), the geothermal-only plant has a lower LCOE than the hybrid cycle and thus could be developed without the need for solar heat addition. iv A geothermal-natural-gas reciprocating engine hybrid plant was evaluated for an Elk Hills, California case study location. The Elk Hills case study analysis indicates that when the natural-gas engine operates for more than 12 hours per day the hybrid plant can produce power at an LCOE lower than a standalone geothermal plant, and comparable to that of the standalone natural-gas reciprocating engine, while also reducing the carbon intensity of the power generated relative to the standalone natural-gas engine. This may represent a scenario in which the hybrid plant provides an opportunity for the deployment of a low-temperature geothermal resource that otherwise may have an LCOE too high to develop and operate as a standalone resource, while also reducing the carbon intensity of natural-gas generation sources. A "triple-hybrid" plant that combines natural gas, solar thermal, thermal energy storage, and geothermal was also investigated. A natural-gas combustion turbine (NGCT) is added to the geothermal-solar hybrid such that the hot exhaust gas from the gas turbine provides an alternative source of heat to the steam turbine of the hybrid cycle. Analysis results suggest that the triple-hybrid plant has a significantly higher energy generation and revenue than a standalone NGCT or the original geothermal-solar hybrid. The triple-hybrid design benefits most from using a smaller solar field so that the solar energy can be dispatched at the most valuable times available. The triple-hybrid plant also has a lower LCOE than the standalone NGCT. The triple-hybrid plant was evaluated making simple assumptions about the dispatch profile of the gas cycle, and more nuanced and realistic dispatching schedules should be analyzed in future work.

15 GEOTHERMAL ENERGY↗

Techno-Economic Analysis for a Potential Geothermal District Heating System in Tuttle, Oklahoma: Preprint

Geothermal deep direct use (DDU) has potential across a wide swath of the United States but is underutilized due to challenging project economics associated with developing a deep geothermal resource for a large-scale and variable heat demand. The National Renewable Energy Laboratory (NREL) and University of Oklahoma evaluated the feasibility of a geothermal district heating (GDH) and cooling system in two schools and 250 houses by utilizing existing oil and gas (O&G) wells in Tuttle, Oklahoma. Heating and cooling demand in the two schools and a typical single-family house were modeled using EnergyPlus building energy simulation software. The modeling results indicated that annual heating demand in two schools and 250 houses is approximately 2.61 GWhth, and cooling demand in the two schools is approximately 2.65 GWhth. In this scope, the techno-economic analysis (TEA) was conducted using the GEOPHIRES tool combined with the TOUGH2 reservoir simulator. The reservoir performance, including geothermal heat production capacity, was modeled by the reservoir simulator TOUGH2. Then, levelized cost of heat (LCOH) was calculated using GEOPHIRES version 3.0, which includes new features such as hourly heat load optimization and peak performance evaluation. Geothermal reservoir temperature was estimated as 90.5 degrees C at a total depth of 3.3 km by the regional average temperature gradient of 22.8 degrees C/km and validated by cation geothermometer calculations. Four production scenarios with two different well configurations and two different heat load profiles have been developed for well flow rates ranging between 3.1 kg/s and 9.3 kg/s. The LCOH of the district heating and cooling system was calculated between $95 and $210/MWh ($28/MMBtu to $62/MMBtu) for four different production scenarios. Typical natural gas prices for residential customers in Oklahoma have ranged from 9 to 19 $/MMBtu over the past decade, which indicates a challenge for deployment of such a GDH system.

deep direct-use↗

Techno-economic feasibility of geothermal energy production using inactive oil and gas wells for district heating and cooling systems in Tuttle, Oklahoma

Oil and gas wells have been drilled in the United States and often encounter hot co-produced water possibly suitable for geothermal direct-use applications. Here this study evaluated geothermal resources, heating and cooling demand, and techno-economic potential of four oil and gas wells repurposed for geothermal energy production to serve two public schools and 250 nearby houses in Tuttle, Oklahoma, USA. Subsurface geology in the study area primarily consists of Permian to Mississippian sandstone and limestone formations approximately from 2 km to 3.5 km depth. With a geothermal gradient of 25.3 °C/km, the temperature of geothermal energy production was estimated as 68.2 °C at 2.1 km. The potential of calcite scaling within boreholes and pipes was minimal. Using the characterized reservoir properties, techno-economic analyses were conducted for evaluating levelized costs of geothermal energy production for direct-use heating and cooling and district heating systems with five different production scenarios. Heating and cooling demand in two schools and 250 houses and additional 0.3 MW and 0.6 MW base heating loads for potential geothermal direct-use applications in the study area were also incorporated in the modeling. Results indicated that the levelized cost of heating of geothermal district heating systems utilizing existing wells were significantly lower than those of conventional geothermal energy systems that include well drillings. The geothermal energy production with doublet and quartet configurations was generally sufficient to supply total annual heating demand in the district, while a peaking boiler was used to supply peak loads. Doublet configurations showed higher production temperature with a lower thermal drawdown than the quartet configurations. The doublet system at 2.1 km production depth with 9.3 kg/s flow rate represented the optimal levelized cost of $71/MWh and 91.2% utilization factor. These results imply that the Tuttle geothermal district heating system is techno-economically feasible and comparable to geothermal district heating systems in the United States and the regional natural gas rate for residentials by recycling inactive oil and gas wells with no drillings.

15 GEOTHERMAL ENERGY↗

Geospatial characterization of low-temperature heating and cooling demand in residential, commercial, manufacturing, agricultural, and data center sectors for potential geothermal applications in the United States

Thermal demand for heating and cooling has been predominantly supplied by fossil fuel combustion in the United States, although low-carbon alternatives are extensively available including geothermal, solar thermal, and waste heat. Here, this study analyzed end-use energy consumption, fuel expenditure, and data center commissioned power data to geospatially characterize the U.S. low-temperature heating and cooling demand at the county level in residential, commercial, manufacturing, agricultural, and data center sectors and understand potential opportunities for geothermal applications. In the analysis, the regional-scale energy consumption data was incorporated with system efficiencies to address actual demand and was then disaggregated with weighting factors to the county level. The results indicated that total low-temperature heating and cooling demand is 16.7 EJ, combining heating demand of 10.8 EJ and cooling demand of 5.9 EJ. Overall, 59.9 % (10 EJ) of the low-temperature heating and cooling demand occurred in the residential sector. The heating and cooling demand visualized in maps represented that the geospatial distribution of heating and cooling demand in the residential and commercial sectors is governed by the number of housing units and climate zone designations, while heating and cooling demand in the manufacturing, agricultural, and data center sectors is dependent on the number and location of facilities. The results also demonstrated that geothermal heat pumps are broadly used in the residential and commercial sectors for heating and cooling in the U.S. Midwest, South, and Northeast regions but are limited in the West, implying great decarbonization potential in the future.

15 GEOTHERMAL ENERGY↗

Evaluation of sintered bauxite proppant for binary enhanced geothermal systems

Abstract Solid granular proppant particles are widely used in oil and gas development to sustain permeability through fractures after hydraulic stimulation. Similar proppants are of interest for geothermal applications where the goal of sustaining permeability is the same, but the harsh geothermal environment risks rapid proppant degradation that will reduce fracture permeability. Here, we present proppant conductivity experiments using saw cut granite, tensile fractured granite, and aluminum control specimens packed with sintered bauxite ceramic proppants at concentrations of 0.0, 0.1, and 1.0 kg/m 2 . Simulated geothermal conditions included temperatures up to 130 °C and normal closure stresses up to 60 MPa. Compared to unpropped specimens, peak fracture conductivity enhancement was up to 6 orders of magnitude. At simulated geothermal conditions, proppants were able to sustain fracture conductivity over 60 h, but chemical dissolution and decreasing permeability over time were evident. Irreversible conductivity reductions with crushing and embedment of proppants during loading stages were also observed. Overall, sintered bauxite proppant remains a promising option for low-temperature binary-cycle enhanced geothermal systems.

58 GEOSCIENCES↗

A review of Geological Thermal Energy Storage for seasonal, grid-scale dispatching

Energy storage is essential for the decarbonization of the U.S. energy grid, especially with the increasing deployment of variable renewable energy sources like solar and wind. Geological thermal energy storage (GeoTES) has emerged as a promising long duration, grid scale solution, providing stability and security through flexible operations and valuable grid services. GeoTES utilizes subsurface reservoirs to store thermal energy for power generation and direct-use heating and cooling. This approach significantly enhances the use of low-temperature reservoirs, which would otherwise be unsuitable for geothermal power plants. It also aligns well with depleted oil and gas reservoirs, concentrating solar power, non-flexible renewables (photovoltaic and wind), and geothermal-related power cycles. Given the favorable marginal costs of GeoTES as storage duration increases, it becomes particularly competitive for seasonal, grid-scale dispatch, where few technologies are viable. This paper provides a comprehensive review of GeoTES systems and the research underpinning itsr development. This analysis begins by defining and categorizing the unique characteristics of thermal energy storage techniques, setting GeoTES apart from other technologies. The various components, configurations, subsurface characteristics, and modeling efforts that guide GeoTES development are then explored. Finally, challenges in GeoTES research, development, and deployment are discussed, along with mitigation strategies and lessons from related technologies. Beyond their economic benefits, GeoTES systems support grid resilience and decarbonize industrial processes. Their scalability, broad distribution, seasonal storage potential, and flexible dispatch capacity make GeoTES a valuable tool for expanding renewable energy deployment and addressing climate change.

15 - GEOTHERMAL ENERGY↗

Subsurface Characterization for Evaluating Geothermal Resource Potential from Existing Oil and Gas Wells in Tuttle, Oklahoma: Preprint

Oil and gas (O&G) wells often encounter co-produced hot water, possibly suitable for geothermal direct-use applications. The City of Tuttle is located on the eastern part of the Anadarko sedimentary basin in Oklahoma with high heat-in-place potential and recovery capability at depth. This study aims at demonstrating the potential of geothermal energy production for direct-use applications in two public schools and 250 nearby houses in Tuttle via repurposing existing O&G wells. In this scope, geochemistry, geology, and borehole log data were collected and incorporated into a 3D conceptual subsurface model. A digital elevation model (DEM) was used to represent the study area topography with four O&G wells. In addition, hydrogeochemical characteristics of the geothermal fluid and scaling potential were analyzed using ternary diagrams and chemical ratios to develop mixing models. The subsurface geology model indicated that the study area primarily consists of Permian to Mississippian Sandstone and Limestone formations, implying a porosity ranging between 12% and 22%, and a permeability up to 3.90E-14 m2 in certain reservoir levels. The reservoir temperature is expected to be ranging between 80 degrees C to 95 degrees C around 3 km depth with an average temperature gradient of 22.8 degrees C/km. Chemical geothermometers also estimated the reservoir temperature as 90 degrees C. Findings of the chemical model demonstrated that the geothermal fluid is Sodium-Potassium-Chloride-Sulfate type and possibly mixed with shallow groundwater resulting in higher Ca and Mg concentrations and lower Na/K ratio implying lower calcite scaling. These results comprehensively characterize the potential of geothermal resources in the study area and imply that geothermal energy production by repurposing existing O&G wells is suitable for low-temperature direct-use applications.

GEOTHERMAL ENERGY↗

Subsurface Characterization for Evaluating Geothermal Resource Potential from Existing Oil and Gas Wells in Tuttle, Oklahoma

Oil and gas (O&G) wells often encounter co-produced hot water, possibly suitable for geothermal direct-use applications. The City of Tuttle is located on the eastern part of the Anadarko sedimentary basin in Oklahoma with high heat-in-place potential and recovery capability at depth. This study aims at demonstrating the potential of geothermal energy production for direct-use applications in two public schools and 250 nearby houses in Tuttle via repurposing existing O&G wells. In this scope, geochemistry, geology, and borehole log data were collected and incorporated into a 3D conceptual subsurface model. A digital elevation model (DEM) was used to represent the study area topography with four O&G wells. In addition, hydrogeochemical characteristics of the geothermal fluid and scaling potential were analyzed using ternary diagrams and chemical ratios to develop mixing models. The subsurface geology model indicated that the study area primarily consists of Permian to Mississippian Sandstone and Limestone formations, implying a porosity ranging between 12% and 22%, and a permeability up to 3.90E-14 m2 in certain reservoir levels. The reservoir temperature is expected to be ranging between 80 degrees C to 95 degrees C around 3 km depth with an average temperature gradient of 22.8 degrees C/km. Chemical geothermometers also estimated the reservoir temperature as 90 degrees C. Findings of the chemical model demonstrated that the geothermal fluid is Sodium-Potassium-Chloride-Sulfate type and possibly mixed with shallow groundwater resulting in higher Ca and Mg concentrations and lower Na/K ratio implying lower calcite scaling. These results comprehensively characterize the potential of geothermal resources in the study area and imply that geothermal energy production by repurposing existing O&G wells is suitable for low-temperature direct-use applications.

gas wells↗

Oxygen isotope fractionation between analcime and water - An experimental study

The oxygen isotope fractionation between analcime and water is studied to test the feasibility of using zeolites as low-temperature thermometers. The fractionation of oxygen isotopes between natural analcime and water is determined at 300, 350, and 400 C, and at fluid pressures ranging from 1.5 to 5.0 kbar. Also, isotope ratios for the analcime framework, the channel water, and bulk water are obtained. The results suggest that the channel water is depleted in O-18 relative to bulk water by a constant value of about 5 percent, nearly independent of temperature. The analcime-water fractionation curve is presented, showing that the exchange has little effect on grain morphology and does not involve recrystallization. The exchange is faster than any other observed for a silicate. The exchange rates suggest that zeolites in active high-temperature geothermal areas are in oxygen isotopic equilibrium with ambient fluids. It is concluded that calibrated zeolites may be excellent low-temperature oxygen isotope geothermometers.

Karlsson, Haraldur R.↗

Geological Thermal Energy Storage (GeoTES) Charged with Solar Thermal Technology Using Depleted Oil/Gas Reservoirs and Carnot-Battery Technique Using Shallow Reservoirs: Preprint

Geological thermal energy storage (GeoTES) utilizes the underground reservoirs to storage and dispatch energy per given demand schedule over a time scale up to seasons of a year. The energy input can be of various sources/forms; in this paper, we investigate 1) the GeoTES technology with solar thermal hybridization and using depleted oil/gas reservoirs; 2) the GeoTES technology with heat pumps charged by excess renewable electricity and using low-temperature shallow reservoirs. For each GeoTES technology, we carry out the suitability analysis of candidate reservoirs, develop initial techno-economic models, and validate the model with selected case study. The paper provides an overview of our technical progress on the topics of concern and aims to promote a wider acceptance of the GeoTES technologies in the future energy market.

Carnot battery↗

RePED 250: Manufacturing and Market Analysis of High-Temperature Alternators

The novel repetitive pulsed electric drill 250 (RePED 250) has the potential to greatly lower the costs and drilling times of geothermal projects. This tool discharges electric pulses through hard rock formations, shattering the rock in tension and allowing it to be quickly removed. One hurdle in bringing this technology to market is the RePED 250 downhole alternator. This component is essential for supplying power to the electronic drilling tool. There are currently no downhole tools on the market that meet the RePED 250 alternator's high temperature and power requirements. This report focuses on the path to commercialization for this novel alternator technology being developed as part of the RePED 250 project. One aim of this work is to identify the geothermal market size for the RePED 250 alternator, as well as other potential markets for this technology outside of geothermal. The geothermal market is very small, with only approximately 13 wells drilled in the United States each year. The worldwide market is several times this size and growing each year. The ability of the RePED 250 technology to drastically reduce the cost of geothermal projects may also lead to an increase in this market size. Technology developed for the high-temperature, high-power RePED 250 alternator can also be used to create high-temperature and high-power motors. These motors and alternators will have potential applications in oil and gas drilling, a $300 billion dollar industry in the United States alone, as well as in more distant industries such as aircraft, weapon systems, space exploration, and electric vehicles. Other aspects of the RePED 250 alternator's path to commercialization are also analyzed, including the supply chain for production materials and potential manufacturing methods. The supply chain and manufacturing practices for low-temperature motors and alternators are well established and require relatively minor changes for the high-temperature and high-power RePED 250 alternator. Sourcing for high-temperature materials has been identified, as well as potential supply chain risks. These most notably include electrical steel and high-temperature samarium cobalt (SmCo) magnets. Overall, these risks are not expected to be significant at the likely manufacturing scale required for the RePED 250.

15 GEOTHERMAL ENERGY↗