Utah FORGE: Well 58-32 Stimulation Data
Pressure, temperature, and flow data from open-hole, upper perforation, and lower perforation well stimulations gathered from various tools collected at well 58-32 during phase 2C.
SEARCH · Search NASA
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Pressure, temperature, and flow data from open-hole, upper perforation, and lower perforation well stimulations gathered from various tools collected at well 58-32 during phase 2C.
The U.S. Department of Energy’s (U.S. DOE) Frontier Observatory for Research in Geothermal Energy (FORGE) is a field laboratory that provides a unique opportunity to develop and test new technologies for characterizing, creating and sustaining Enhanced Geothermal Systems (EGS) in a controlled environment. In 2018, the U.S. DOE selected a site in south-central Utah for the FORGE laboratory. Numerous geoscientific studies have been conducted in the region since the 1970s in support of geothermal development at Roosevelt Hot Springs. A vertical scientific well, 58-32, was drilled and tested to a depth of 2290 m (7515 ft) GL in 2017 on the FORGE site to provide additional characterization of the reservoir rocks. The well encountered a conductive thermal regime and a bottom hole temperature of 199degC (390degF). More than 2000 natural fractures were identified, but measured permeabilities are low, less than 30 micro-darcies. Induced fractures indicate that the maximum horizontal stress trends NNE-SSW, consistent with geologic and well observations from the surrounding area. Approximately 45 m (147 ft) at the base of the well was left uncased. A maximum wellhead pressure of 27.6 MPa (4000 psig) at an injection rate of ~1431 L/min (~9 bpm) was measured during stimulation testing in September 2017. Conventional diagnostic evaluations of the data suggest that hydraulic fracturing and shearing occurred. Estimates of the stress gradient for delta_h_min range from of 16.7 to 17.6 kPa/m (0.74 to 0.78 psi/ft). A gradient of 25.6 kPa/m (1.13psi/ft) was calculated for delta_V. In 2019, the 2017 open-hole stimulation in well 58-32 was repeated with injection rates up to 2385 L/min (15 bpm). Two additional stimulations were conducted in the cased portion of the well; one to stimulate critically stressed fractures and the second to test noncritically stressed fractures. Breakdown of the zone spanning critically-stressed fractures occurred at a surface pressure of approximately 29.0 MPa (4200 psig). Although stimulation of the noncritically stressed fractures was interrupted by failure of the bridge plug beneath the perforated interval, micro-seismic data suggests stimulation of the fractures may have been initiated at a surface pressure of 45.5 MPa (6600 psig). These stimulation results support the conclusion the Mineral Mountains granitoid is an appropriate host for EGS development. Micro-seismicity was monitored during the stimulations using surface and downhole instrumentation. Five seismometers and a nodal array of 150 seismic sensors were deployed on the surface. A Distributed Acoustic Sensing (DAS) cable and a string of 12 geophones were deployed in well 78-32, drilled to a depth of 998 m (3274 ft) GL. A broadband sensor and a high-temperature geophone were deployed in well 68-32, drilled to a depth of 303 m (994 ft) GL. More than 420 micro-seismic events were detected by the geophone string. Other instruments detected fewer events.
Worldwide Coal Bed Methane (CBM) resources are huge, estimated at 3,000 to 9,000 Tcf. The production rate from CBM reservoirs is low, perhaps 50-100 mcf/day. Various completion methods are being evaluated and new technologies are being developed with the aim of increasing production rates. Considering this interest and activity level, little attention has been paid to the CBM completion fundamentals. Perforating is a critical part of this process, especially considering the PRB development migration from single-coal, open-hole completions into multi-zone, cased-hole completions. This paper describes the first known laboratory-testing program to investigate shaped charge penetration in coal targets. We describe mechanical properties of the coals tested, and penetration results for different shaped charges (of different designs), shot at various stress conditions. CT scan and cutaway imaging of the perforation tunnels are also discussed. Tests were conducted under dry and saturated conditions. The preliminary experiments reported here indicate that shaped charge penetration in coal is significantly less than expected, considering the target's density and strength. The authors provide insight into what may be the reasons for these unexpected results and recommend a path forward for shaped charge testing, designs, predictive tools, and how to optimize CBM completions.
Abstract For transformers and inductors to meet the world’s growing demand for electrical power, more efficient soft magnetic materials with high saturation magnetic polarization and high electrical resistivity are needed. This work aimed at the development of a soft magnetic composite synthesized via spark plasma sintering with both high saturation magnetic polarization and high electrical resistivity for efficient soft magnetic cores. CoFe powder particles coated with an insulating layer of Al 2 O 3 were used as feedstock material to improve the electrical resistivity while retaining high saturation magnetic polarization. By maintaining a continuous non-magnetic Al 2 O 3 phase throughout the material, both a high saturation magnetic polarization, above 1.5 T, and high electrical resistivity, above 100 μΩ·m, were achieved. Through microstructural characterization of samples consolidated at various temperatures, the role of microstructural evolution on the magnetic and electronic properties of the composite was elucidated. Upon consolidation at relatively high temperature, the CoFe was to found plastically deform and flow into the Al 2 O 3 phase at the particle boundaries and this phenomenon was attributed to low resistivity in the composite. In contrast, at lower consolidation temperatures, perforation of the Al 2 O 3 phase was not observed and a high electrical resistivity was achieved, while maintaining a high magnetic polarization, ideal for more efficient soft magnetic materials for transformers and inductors.
Composite laminates reinforced by woven basalt fibers and based on different polymer matrices were prepared and mechanically characterized, in static and dynamic conditions, to compare the results and evaluate the influence of the matrix type. In this regard, a thermoplastic resin, polyamide 6 (PA6), and two thermosetting matrices, vinyl ester and epoxy grades, commonly used for high-performance applications, were considered. Indentation depth measurements carried out by a confocal microscope and ultrasound analyses performed on specimens subjected to falling dart tests at levels of impact energies lower than the perforation one permitted to evaluate the extent of plastic deformations and of subjected delaminations, respectively. These data have provided useful information about the involved damage mechanisms and highlighted interesting perspective of use for the eco-friendly thermoplastic sample.
A synergistic N doping plus PO 4 3- intercalation strategy is used to induce high conversion (ca. 41%) of 2H-MoS 2 into 1T-MoS, which is much higher than single N doping (ca. 28 %) or single PO 4 3- intercalation ca. 10%). A scattering mechanism is proposed to illustrate the synergistic phase transformation from the 2H to the 1T phase, which was confirmed by synchrotron radiation and.spherical aberration TEM. To further enhance reaction kindies, the designed (N, PO 4 3- )-MoS 2 nanosheds are combined with conductive vertical graphene (VG) skeleton forming binder-free arrays fir high efficiencyhydrogen evolution reaction (HER). Owing 10 the decreased band gap, lower d-band censer, and smaller hydrogen adsorption/desorption energy, the designed (NPO 4 3- )-MoSJVG electrode shows excellent HER perfor mance with a lower Tafel slope and overpotential than N-MoS 2 /VG, PO 4 3- -MoS 2 /VG counterparts, and other Mo-base catalysts in the literature.
A pressurized water reactor vessel having a flow skirt formed from a perforated cylinder structure supported in the lower reactor vessel head at the outlet of the downcomer annulus, that channels the coolant flow through flow holes in the wall of the cylinder structure. The flow skirt is supported at a plurality of circumferentially spaced locations on the lower reactor vessel head that are not equally spaced or vertically aligned with the core barrel attachment points, and the flow skirt employs a unique arrangement of hole patterns that assure a substantially balanced pressure and flow of the coolant over the entire underside of the lower core support plate.
A unique accelerated aging humidity chamber for simulating the natural aging process of nuclear grade high efficiency particulate air (HEPA) filter media is being designed, implemented, and tested. The nuclear industry currently lacks information regarding the shelf life and service life of HEPA filter media. The Department of Energy recommends disposing of HEPA filters 10 years after the manufacture date for filters operated under dry conditions. Studies have shown the tensile strength and water repellency of HEPA filter media diminish with age. The chamber's principal function is to sustain an elevated relative humidity condition for an extended duration specified by the Arrhenius aging model. To accomplish this, various design parameters were established: (1) consistently achieve uniform humidity conditions within the chamber to equally expose media sheets, (2) ensure the chamber is sufficiently sealed to mitigate the uncontrolled infiltration of air, (3) confidently secure the media sheets to avert the introduction of unnecessary stressing/creasing, (4) fabricate the chamber from clear polycarbonate material to allow inspection of the media sheets, (5) provide a safe and ergonomic design for personnel, (6) ensure the chamber design is replicable and relatively easy to fabricate/assemble. A humidity source, fan, PID controller, humidity and temperature transmitters, and data loggers are required for proper operation and control of the chamber. The humidity source must accommodate target values up to 95% relative humidity throughout the chamber. The three humidity and temperature transmitters are strategically spaced throughout the chamber to ensure uniform conditions. The 10 cubic feet per minute (CFM) fan selected intends to accomplish the desired air change rate inside the chamber of approximately 20 air changes per hour (ACH). The 2 plenums on the upper and lower portions of the chamber utilize a perforated design to uniformly distribute air, promote air mixing, and control the air velocity entering the chamber. Industrial blueprint hanging clamps are being retrofitted to be seated within the chamber drawers and firmly secure the nuclear grade filter media. The aged media will be evaluated using autopsy methodology, and the results obtained intend to help clarify the useful life of nuclear grade HEPA filters. Nuclear grade high efficiency particulate air (HEPA) filters are defined as disposable, extended-media, dry-type filters with a rigid casing enclosing the full depth of the pleats and have a minimum particle removal efficiency of 99.97%. [1] - HEPA filters are constantly exposed to stressors and subsequently have been shown to degrade as the filter ages. Properties such as tensile strength and water repellency, along with others, are negatively impacted. [2] - Due to the scarcity of naturally aged HEPA filters available, it is crucial to develop accelerated aging methods which effectively mimic the natural degradation effects. - After accelerated aging, the filters are subject to testing in the Axial Flow Large Scale Test Stand (ALSTS) and other analysis techniques such as the same qualification tests performed directly after being manufactured. - Quality data is necessary for future decisions regarding the lifetime of nuclear grade HEPA filters. - The objective is to develop a prototype accelerated aging humidity chamber for nuclear grade HEPA filter media. The chamber should expose the media to commonly occurring stressors to expedite the degradation process caused by aging. PID yields reliable and reproducible results: - CFD model correlates well with actual performance; - Further analysis is needed to complete characterization; - Future work for the chamber is still to be completed. The data shown in Figure 5 and Table 1 indicate the system is functioning as designed. As can be determined from the system response evaluation in Table 1, the PID controller is yielding reliable and reproducible results at each set point. As the set point increases, the time constant and 20% settling time increase accordingly. From the results in Table 1, it stands to reason that the CFD model correlates well with the actual performance of the system. Each system response parameter for the 90%RH* CFD model is slightly lower than the parameters collected from the physical model tested at an equivalent set point. This is to be expected considering the inlet in the CFD model is a constant supply of water vapor, whereas the physical model uses a PID controller to monitor the amount of water vapor needed and reacts accordingly. More analysis is still to be done on the prototype chamber. A pressure test will be conducted in order to determine the hourly leak rate of the chamber. This test will involve constant air flow into the chamber until the desired pressure is reached. A uniformity test will also be conducted in order to ensure each filter medium is being exposed to equivalent relative humidity levels. This test will involve an array of humidity meters strategically oriented inside the chamber to record any possible gradients. Future work for the chamber includes dehumidification abilities, tests while fully loaded with filters, and temperature control. Once completed, the autopsy team at Institute of Clean Energy Technology will conduct necessary accelerated aging studies as needed.
Spontaneously forming structures of a system composed of dimyristoyl phosphatidylcholine (DMPC) and 3-[(3-cholamidopropyl)dimethylammonio]-2-hydroxy-1-propanesulfonate (CHAPSO) were studied by small-angle neutron scattering (SANS), 31 P NMR, and stimulated echo (STE) pulsed field gradient (PFG) 1 H NMR diffusion measurements. Charged lipid dimyristoyl phosphatidylglycerol (DMPG) was used to induce different surface charge densities. The structures adopted were investigated as a function of temperature and lipid concentration for samples with a constant molar ratio of long-chain to short-chain lipids (=3). In the absence of DMPG, zwitterionic bicellar mixtures exhibited a phase transition from discoidal bicelles, or ribbons, to multilamellar vesicles either upon dilution or with increased temperature. CHAPSO-containing mixtures showed a higher thermal stability in morphology than DHPC-containing mixtures at the corresponding lipid concentrations. In the presence of DMPG, discoidal bicelles (or ribbons) were also found at low temperature and lower lipid concentration mixtures. At high temperature, perforated lamellae were observed in high concentration mixtures ( ≥ 7.5 wt %) whereas uniform unilamellar vesicles and bicelles formed in low-concentration mixtures ( ≤ 2.5 wt %), respectively, when the mixtures were moderately and highly charged. Lastly, from the results, spontaneous structural diagrams of the zwitterionic and charged systems were constructed.
During the Capstone Depleted Uranium (DU) Aerosol Study, aerosols containing depleted uranium were produced inside unventilated armored vehicles (i.e., Abrams tanks and Bradley Fighting Vehicles) by perforation with large-caliber DU penetrators. These aerosols were collected and characterized, and the data were subsequently used to assess human health risks to personnel exposed to DU aerosols. The DU content of each aerosol sample was first quantified by radioanalytical methods, and selected samples, primarily those from the cyclone separator grit chambers, were analyzed radiochemically. Deposition occurred inside the vehicles as particles settled on interior surfaces. Settling rates of uranium from the aerosols were evaluated using filter cassette samples that collected aerosol as total mass over eight sequential time intervals. A moving filter was used to collect aerosol samples over time particularly within the first minute after the shot. The results demonstrate that the peak uranium concentration in the aerosol occurred in the first 10 s, and the concentration decreased in the Abrams tank shots to about 50% within 1 min and to less than 2% 30 min after perforation. In the Bradley vehicle, the initial (and maximum) uranium concentration was lower than those observed in the Abrams tank and decreased more slowly. Uranium mass concentrations in the aerosols as a function of particle size were evaluated using samples collected in the cyclone samplers, which collected aerosol continuously for 2 h post perforation. The percentages of uranium mass in the cyclone separator stages from the Abrams tank tests ranged from 38% to 72% and, in most cases, varied with particle size, typically with less uranium associated with the smaller particle sizes. Results with the Bradley vehicle ranged from 18% to 29% and were not specifically correlated with particle size.
Bronchobiliary fistula is a rare and is an uncommon but severe complication of hydatid disease of the liver. Treatment has traditionally been surgical resection, but embolization and stent placement have been described. The invasive method seems to be a key component of patient treatment. We describe a case of a 58-year-old woman who, 25 years before, had undergone surgery for a hydatid cyst. A total cystectomy without previous puncture or parasite extraction was carried out. The lower aspect of the cyst was found to be completely perforated over the biliary duct. During the postoperative course, the patient had subphrenic right-sided pleural effusion and biliary fistula that subsided with medical treatment. Afterward, the patient came to the outpatient area of our hospital complaining of leakage of purulent exudate through the cutaneous opening, pain located on the right hypochondrium radiating to the right hemithorax, malaise, fever, chronic cough, and occasional vomiting of bile. Fistulography revealed an anfractuous cavity communicating with a residual cystic cavity on the right hepatic lobe. We observed communication with the intrahepatic canaliculi. Computed tomographic scan revealed a fistulous tract on the anterior liver border through the abdominal wall. There were no posttreatment complications. The patient is asymptomatic.
Following a recent investigation into chemi-ionization and chemiluminescence during gradual aeration of small, laminar methane flames, we proposed that partial oxidation products, or syngas constituents, formed in the pre-flame zone well below the luminous region, were responsible for the observed effects. We therefore map temperature, CO, and H{sub 2} for geometries and conditions relevant to burners in domestic boiler systems, to assess the potential hazard of CO release into the ambient atmosphere, should any partial quenching occur. CO concentrations peaks of 5.5 volume % are recorded in the core surrounding the axis. Appreciable CO concentrations are also found in the absence of added air. Experiments on various burner port geometries and temperatures suggest that this is not due to air entrainment at the flame base but to diffusion from zones closer to the flame. Next, quenching surfaces such as grids, perforated plates and flame trap matrices of different metals are progressively lowered into the flame. To avoid flow line distortion, suction aspirates the quenched products. The highest emission rate occurs with the quenching plane some 4 mm above the burner; further lowering of the quenching surface causes flame extinction. The maximum CO release is close to converting 10% of the CH{sub 4} feed, with some variation with quenching material. Expressing this potential release in terms of, e.g. boiler power, predicts a potentially serious hazard. Results of numerical simulations adequately parallel the experimental sampling profiles and provide insights into local concentrations, as well as the spatially resolved CO flux, which is calculated for a parabolic inlet flow profile. Integration across the stream implies, on the basis of the simulation, a possible tripling of the experimental CO release, were quenching simply to release the local gas composition into the atmosphere. Comparison with experiment suggests some chemical interaction with the quenching surface. (author)
A combined experimental and self-consistent-field theoretical (SCFT) investigation of the phase behavior of poly(stryrene-b-dimethylsiloxane-b-styrene) (PS-b-PDMS-b-PS, or SDS32) thin films during solvent vapor annealing is presented. The morphology of the triblock copolymer is described as a function of the as-cast film thickness and the ratio of two different solvent vapors, toluene and heptane. SDS32 formed terraced bilayer morphologies even when the film thickness was much lower than the commensurate thickness. The morphology transitioned between bilayer cylinders, bilayer perforated lamellae, and bilayer lamellae, including mixed structures such as a perforated lamella on top of a layer of in-plane cylinders, as the heptane fraction during solvent annealing increased. SCFT modeling showed the same morphological trends as a function of the block volume fraction. In comparison with diblock PS-b-PDMS with the same molecular weight, the SDS32 offers a simple route to produce a diversity of well-ordered bilayer structures with smaller feature sizes, including the formation of bilayer perforated lamellae over a large process window.
The US Department of Energy is developing a uranium-molybdenum metal alloy Enhanced Accident Tolerant Fuel concept for Light Water Reactor applications that provides improved fuel performance during normal operation, anticipated operational occurrences, and postulated accidents. The high initial uranium atom density, the high thermal conductivity, and a low heat capacity permit a U-Mo-based fuel assembly to meet important design and safety requirements. These attributes also result in a fuel design that can satisfy increased fuel utilization demands and allow for improved accident tolerance in LWRs. This paper summarizes the results obtained from the on-going activities to; 1) evaluate the impact of the U-10wt%Mo thermal properties on operational and accident safety margins, 2) produce a triple extrusion of stainless steel cladding/niobium liner/U-10Mo fuel rod specimen and 3) test the high temperature water corrosion of rodlet samples containing a drilled hole in the cladding. Characterization of the cladding and liner thickness uniformity, microstructural features of the U-Mo gamma phase, and the metallurgical bond between the component materials will be presented. The results from corrosion testing will be discussed which yield insights into the resistance to attack by water ingress during high temperature water exposure for the triple extruded samples containing a drilled hole. These preliminary evaluations find that the U-10Mo fuel design concept has many beneficial features that can meet or improve conventional LWR fuel performance requirements under normal operation, AOOs, and postulated accidents. The viability of a deployable U-Mo fuel design hinges on demonstrating that fabrication processes and alloying additions can produce acceptable irradiation stability during normal operation and accident conditions and controlled metal-water reaction rates in the unlikely event of a cladding perforation. In the area of enhanced accident tolerance, a key objective is to establish that the lower stored energy of the U-Mo fuel design can provide the emergency core cooling systems the opportunity to maintain the reactor core in a coolable geometry following an accident.
This study employs the finite element method (FEM) to predict the impact of pit shape on pit stability via shape factors of various pit geometries relevant to localized corrosion. Lower values of the shape factor indicate an increased ease in maintaining pit stability. Analyzed geometries include undercut pits, bispherical pit-within-pit structures, and covered pits with perforated (lacy) covers. The effect of the water layer thickness, transport properties of the electrolyte inside and outside the pit, and cathode location on the pit shape factor were also explored. Results show that occluded pits exhibit lower shape factors than open ones, with disk-shaped pits decreasing further as c/r ratio and occlusion angle increase. The findings also suggest minimal influence from a secondary pit if the primary remains active. An equation is presented that quantifies the impact of lacy covers, revealing significant shape factor value reduction. Additionally, high salt concentrations inside pits have a limited stabilizing effect compared to geometry, while thin water layers and adjacent cathodic/sinks reduce pit stability.
The Hydraulic Fracturing Test Site 2 (HFTS-2) is a joint industry project in the Delaware basin to advance hydraulic fracturing understanding and improve productivity in shale reservoirs. The project integrates multi-disciplinary approaches to evaluate different completion designs, well spacing, inter-well communication, and stimulated rock volume, among other factors. This paper focused on two major areas related to hydraulic fracture performance. First, an analysis of different completion designs on cluster efficiency based on near well Distributed Acoustic Sensing (DAS). Second, an evaluation of well and completion designs on inter-well fracture driven interactions (FDIs) based on downhole pressure monitoring. Fluid/sand distribution and cluster efficiency analyses were based on near wellbore DAS data collected from two adjacent horizontal wells completed in two different landing zones in the Wolfcamp formation. These wells had different completion designs aiming to evaluate the effect of normal vs. extended stage lengths, perforation hole tapering and limited entry. Standard deviation from ideal fluid/sand distribution and waterfall plots were used to evaluate cluster efficiency for each design and stage. Inter-well FDIs analysis was conducted among the horizontal wells and a vertical monitor well. One horizontal well served as the monitor well while the other horizontal well was being treated. The vertical well was instrumented with downhole pressure and temperature gauges to aid monitoring fracture height growth. The pressure response during and after fracturing was characterized based on maximum pressure increase value and slope. Pressure response vs. FDIs trigger factors such distance, cluster efficiency and stage fluid volume were also analyzed. Based on the different completion and perforation designs tested, DAS analysis suggests that limited entry design worked best. Extreme limited entry showed the potential of high perforation erosion and reduced cluster efficiency. Here, the limited entry and tapered perforation design demonstrated potential to improve the cluster efficiency for extended stage lengths. Pressure monitoring across formation units proved to be critical to understand fracture interactions and fracture vertical growth. Pressure communication across different formation units during hydraulic fracturing operation indicate fractures grew upwards during Wolfcamp wells fracturing. However, this pressure communication dissipated over time. High intensity FDIs were recorded when the frac stages Downloaded from http://onepetro.org/URTECONF/proceedings-pdf/21URTC/1-21URTC/D011S018R001/2477607/urtec-2021-5289-ms.pdf/1 by Carol Worster on 28 February 2022 URTeC 5289 were closer to the pressure gauge location in the monitor wells. Some of these stages that produced high intensity FDIs also had high fluid volume per cluster and low cluster efficiency. The multi-disciplinary and high-quality data collected from HFTS-2 helped to further understand why completion approaches such as limited entry and tapered perforation design are successful in improving cluster efficiency. The DAS data combined with downhole high-resolution pressure measurements also helped to quantify the effect of lower cluster efficiency data on the incidence and intensity of FDIs.
Histotripsy was evaluated as a non-invasive BPH treatment. The prostates of 21 canine subjects were targeted with one of three histotripsy doses. Prostates were harvested immediately, 7 days, or 28 days after treatment and assessed for changes. Lower treatment doses were found to produced scattered cellular disruption and hemorrhage that was sometimes reversible. Higher doses perforated the urethra and produced cavities in the glandular prostate that healed to leave an enlarged urinary channel.
Artificial drainage systems comprising subsurface networks of perforated pipes (tile drains) and engineered surface ditches are widely used to remove excess water from poorly drained agricultural regions. Artificial drainage lowers the water table by design but also has inadvertent effects on the watershed-scale hydrologic response with important implications for flood risk and nutrient exports. We investigated the effects of tile drains on watershed-scale hydrologic response in the Portage River, OH, Watershed using a high-resolution physically based integrated surface/subsurface hydrology model with recently developed capabilities to represent artificial drainage. Tile drains were found to enhance streamflow during times of low flow, generally consistent with previous studies. Streamflow flashiness was found to have a non-monotonic dependence on tile spacing with a minimum at intermediate spacings (∼50 m). Flashiness and the event hydrographs for small tile spacing were similar to the situation with no tiles, but flow paths from farm to stream were very different for those two end member cases, emphasizing the limitations of the stream hydrograph in characterizing hydrologic response. For typical tile spacings, peak flow can either be enhanced or attenuated by the presence of tiles, depending on the size of the event and the antecedent meteorological conditions. Tiles enhance peak flow when the event is below a threshold of ∼25 mm or when events arrive in dry conditions. Peak flow is reduced by tiles when events are large and arrive in conditions that are not overly dry. The dependence on event size and antecedent conditions is explained by differences in available storage and flow paths to the streams. These results provide additional insights into how tile drainage modulates event-scale hydrologic response, an important control on flood generation mechanisms and nutrient exports.