Search NASA⌕ Search

SEARCH · Search NASA

Results for “lumped thermal model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Advanced rocket engine cryogenic turbopump bearing thermal model

A lumped node thermal model was developed representing the Space Shuttle Main Engine (SSME) liquid oxygen (LOX) turbopump turbine end bearings operating in a cryogenically cooled bearing tester. Bearing elements, shaft, carrier, housing, cryogen flow characteristics, friction heat, and fluid viscous energy are included in the model. Heat transfer characteristics for the regimes of forced convection boiling are modeled for liquid oxygen (LOX) and liquid nitrogen (LN2). Large temperature differences between the cryogenic fluid and baring contact surfaces require detailed nodal representation in these areas. Internal loads and friction heat are affected by temperature dependent operating clearances requiring iterations between bearing thermal and mechanical models. Analyses indicate a thermal-mechanical coupling resulting in reduced operating clearances, increased loading and heating which can contribute to premature bearing failure. Contact surfaces operate at temperatures above local saturation resulting in vapor rather than liquid in the contacts, precluding possible liquid film lubrication. Elevated temperatures can reduce lubrication, increase friction, and reduce surface hardness supporting a surface failure mode rather than subsurface fatigue.

Cody, J. C.↗

Validation and Parametric Investigations of an Internal Permanent Magnet Motor Using a Lumped Parameter Thermal Model

One of the key challenges for the electric vehicle industry is to develop high-power-density electric motors. Achieving higher power density requires efficient heat removal from inside the motor. In order to improve thermal management, a multiphysics modeling framework that is able to accurately predict the behavior of the motor, while being computationally efficient, is essential. This paper first presents a detailed validation of a lumped parameter thermal network (LPTN) model of an Internal Permanent Magnet synchronous motor within the commercially available MOTOR-CAD modeling environment. The validation is based on temperature comparison with experimental data and with more detailed finite element analysis (FEA). All critical input parameters of the LPTN are considered in detail for each layer of the stator, especially the contact resistances between the impregnation, liner, laminations, and housing. Finally, a sensitivity analysis for each of the critical input parameters is provided. A maximum difference of 4% - for the highest temperature in the slot-winding and the end-winding - was found between the LPTN and the experimental data. Comparing the results from the LPTN and the FEA model, the maximum difference was 2% for the highest temperature in the slot-winding and end-winding. As for the LPTN sensitivity analysis, the thermal parameter with the highest sensitivity was found to be the liner-to-lamination contact resistance.

42 ENGINEERING↗

Validation and Parametric Investigations Using a Lumped Thermal Parameter Model of an Internal Permanent Magnet Motor

One of the key challenges for the electric vehicle industry is to develop high-power-density electric motors. Achieving higher power density requires efficient heat removal from inside the motor. In order to improve thermal management, a multi-physics modeling framework that is able to accurately predict the behavior of the motor, while being computationally efficient, is essential. This paper first presents a detailed validation of a Lumped Parameter Thermal Network (LPTN) model of an Internal Permanent Magnet (IPM) synchronous motor within the commercially available Motor-CAD® modeling environment. The IPM motor’s stator is studied at steady state, and winding losses are generated by a constant DC current. The validation is based on temperature comparison with experimental data and with more detailed Finite Element Analysis (FEA). All critical input parameters of the LPTN are considered in detail for each layer of the stator, especially the contact resistances between the impregnation, liner, laminations and housing. Finally, a sensitivity analysis for each of the critical input parameters is provided. A maximum difference of 4% — for the highest temperature in the slot windings and the end windings — was found between the LPTN and the experimental data. Comparing the results from the LPTN and the FEA model, the maximum difference was 2% for the highest temperature in the slot windings and end windings. As for the LTPN sensitivity analysis, the thermal parameter with the highest sensitivity was found to be the liner-to-lamination contact resistance. The latter is often ignored in the literature, whereas its impact on temperature rise was found to be more significant than any other contact resistance within the stator.

47 OTHER INSTRUMENTATION↗

Validation and Parametric Investigations Using a Lumped Thermal Parameter Model of an Internal Permanent Magnet Motor: Preprint

One of the key challenges for the electric vehicle industry is to develop high-power-density electric motors. Achieving higher power density requires efficient heat removal from inside the motor. In order to improve thermal management, a multi-physics modeling framework that is able to accurately predict the behavior of the motor, while being computationally efficient, is essential. This paper first presents a detailed validation of a Lumped Parameter Thermal Network (LPTN) model of an Internal Permanent Magnet (IPM) synchronous motor within the commercially available Motor-CAD® modeling environment. The IPM motor’s stator is studied at steady state, and winding losses are generated by a constant DC current. The validation is based on temperature comparison with experimental data and with more detailed Finite Element Analysis (FEA). All critical input parameters of the LPTN are considered in detail for each layer of the stator, especially the contact resistances between the impregnation, liner, laminations and housing. Finally, a sensitivity analysis for each of the critical input parameters is provided. A maximum difference of 4% - for the highest temperature in the slot windings and the end windings - was found between the LPTN and the experimental data. Comparing the results from the LPTN and the FEA model, the maximum difference was 2% for the highest temperature in the slot windings and end windings. As for the LTPN sensitivity analysis, the thermal parameter with the highest sensitivity was found to be the liner-to-lamination contact resistance. The latter is often ignored in the literature, whereas its impact on temperature rise was found to be more significant than any other contact resistance within the stator.

ADVANCED PROPULSION SYSTEMS↗

DEVELOPMENT OF A LUMPED-PARAMETER THERMAL MODEL FOR ELECTRO-HYDRAULIC ACTUATORS

This paper describes a thermal-hydraulic modeling method of a closed-circuit electro-hydraulic actuator (EHA). Despite the high energy efficiency of EHAs, it is always important to assess their cooling requirements, to guarantee that the operating temperature remains within an acceptable range. The method proposed in this paper is based on a lumped parameter approach and simplifies some of the complex heat transfer processes by introducing empirical correction factors. The model is validated by means of temperature measurements on an EHA architecture developed by the author. The good match between the simulation results and experiments confirms the capability of the proposed methodology to predict the temperature performance of the reference EHA under different drive cycles. The paper presents a detailed analysis of the power losses and passive heat dissipation for the reference system. Based on this analysis, the cooling requirements of the EHA are studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A dynamic thermal algal growth model for pilot-scale open-channel raceways

Here this study describes the makeup of and results from a simulation consisting of a lumped thermal model integrated with a dynamic algae growth model to simulate the microalgae productivity of an open-channel raceway cultivation system. The thermal model considers the dynamic effects of weather, light absorption, convective heat transfer, radiation heat transfer, conductive heat transfer, thermal capacitance, and water control strategies. The dynamic algae growth model solves a set of ordinary differential equations consisting of growth functions dependent on incident radiation, temperature, nutrient availability, basal metabolism, and losses due to dark- and photo-respiration. Relative errors in the predicted ash-free dry weight of Nannochloropsis oceanica are 12.5%, -6.1%, and 4.4% for three separate replicates of cultivation cycles (~4.2 m 2 ) performed at AzCATI during the ATP 3 Unified Field Studies in Fall, Spring, and Summer. This research demonstrates that thermal modeling is an essential contributor to the validation of microalgae growth models.

09 BIOMASS FUELS↗

Creation of lumped parameter thermal model by the use of finite elements

In the finite difference technique, the thermal network is represented by an analogous electrical network. The development of this network model, which is used to describe a physical system, often requires tedious and mental data preparation and checkout by the analyst which can be greatly reduced through the use of the computer programs to develop automatically the mathematical model and associated input data and graphically display the analytical model to facilitate model verification. Three separate programs are involved which are linked through common mass storage files and data card formats. These programs are SPAR, CINGEN and GEOMPLT, and are used to (1) develop thermal models for the MITAS II thermal analyzer program; (2) produce geometry plots of the thermal network; and (3) produce temperature distribution and time history plots.

Source record↗

An experimentally validated electro-thermal EV battery pack model incorporating cycle-life aging and cell-to-cell variations

Lithium-ion batteries are used in a wide variety of applications. To meet the power and energy demands of these applications battery packs are composed of hundreds to thousands of cells. The electrical and thermal interactions between cells introduce additional complexity in the pack dynamics. To capture these effects, a battery pack model composed of 192 cells based on a first-generation (2012) Nissan Leaf battery pack is developed in MATLAB/Simulink/Simscape. Here, with this model, we simulate the electrical dynamics (using a first-order equivalent-circuit model), the thermal dynamics (using a first-order lumped-parameter thermal model), and the aging dynamics (using a semi-empirical severity factor-based model) of every cell in the pack and we also create a pack thermal model that explicitly captures the heat exchange between the modules, and the cells contained within, during operation. The models are calibrated and validated, both at the cell and pack level, with experimental data. Two different case studies of this pack model are investigated. In the first case study, an initial, normally-distributed, cell-to-cell capacity variation is introduced and its effect on the pack voltage and module temperatures is studied. In the second case study, we deliberately insert cells with lower than nominal capacity into the pack and we investigate how this type of initial cell-to-cell capacity variation affects the pack’s ability to deliver energy over time. Finally, we also study how parallel-connected cells can reduce the effects of cell-to-cell variations at the expense of increased aging of the pack overall.

25 ENERGY STORAGE↗

Space Suit Thermal Dynamics

The present NASA space suit (the Shuttle EMU) is a self-contained environmental control system, providing life support, environmental protection, earth-like mobility, and communications. This study considers the thermal dynamics of the space suit as they relate to astronaut thermal comfort control. A detailed dynamic lumped capacitance thermal model of the present space suit is used to analyze the thermal dynamics of the suit with observations verified using experimental and flight data. Prior to using the model to define performance characteristics and limitations for the space suit, the model is first evaluated and improved. This evaluation includes determining the effect of various model parameters on model performance and quantifying various temperature prediction errors in terms of heat transfer and heat storage. The observations from this study are being utilized in two future design efforts, automatic thermal comfort control design for the present space suit and design of future space suit systems for Space Station, Lunar, and Martian missions.

Campbell, Anthony B.↗

Predicting Thermal Response in a Li-ion Cell on a UAV Fight Profile

As the energy storage devices continue to "pack" more energy in a small space, any damage, battery component failure, manufacturing defect, or electrically abusing the battery can lead to catastrophic thermal runaway events. A catastrophic thermal event in a cell leads to high temperature, in some instances spewing of battery materials due to gas development from side reactions initiated due to high internal temperatures. Also, a thermal runaway event can propagate from a single "failed" cell to the pack in a battery pack, leading to a more significant event. Mitigating a thermal runaway event is important in the commercial and automotive sectors. However, preventing such events in an electric aircraft (or air taxis) is paramount due to the lack of alternatives in the event of a failure. Battery prognostics algorithms allow the prediction of state-of-charge (SOC) and end-of-life (EOL) of a Li-ion battery in a UAV (unmanned air vehicle) [1]. For this presentation, we will extend this two-level battery predictive algorithm to predict SOC, EOL, and estimated maximum temperature during a simulated flight. The model is extended by integrating a lumped physics-driven thermal model for high current densities [2]. The parameters used to control SOC and EOL are maximum storable charge, time constant for Li-ion diffusivity in the carbon particles, and internal cell resistance. Cycling leads to an increase in the heat generated by an aged Li-ion cell with a LiyCoO2 (LCO) cathode and a LixC6 (MCMB) anode. The aging of a cell leads to increase in SEI layer thickness, the diffusion time for the lithium ions inside the electrodes, and the local reaction rates, in addition to the thermodynamic abuse caused by fixed cycling voltages controlled by a Battery Management System. As the battery ages, the cell resistance increases, while the onset temperature of the thermal runaway decreases (depends on the cell chemistry and cell abuse history). Any large deviation of the cell temperature from the estimated (expected) value can identify a faulty cell. Since SEI decomposition has the lowest onset temperature in the series of reactions leading to thermal runaway, the model considers the self-heating rate of the SEI decomposition as onset temperature (similar to Ref. [3]). The parameters in the Arrhenius equation for the SEI heating rate depend on the number of cycles, the cell's operating temperature, and the cell's abuse history [4,5]. Coupling the electrochemical, thermal, and aging model allow the prognostic algorithm to estimate a typical cell voltage and temperature as a function of age (cycling and calendar), whose departure from measured values from the BMS is used to identify a safety event. In addition, we will present the results from two simulated flight scenarios for a UAV: typical and extreme, since the power requirements vary significantly during take-off, landing, and changing altitudes, while the power requirements remain low during the cruise. For this presentation, the power requirement for a battery pack in a UAV is scaled to a single cell. This cell is cycled through a simulated profile, and the data is collected and used to predict a safety event.

Li-ion↗

Thermal analytic model of 30 cm engineering model mercury ion thruster

A lumped parameter thermal nodal network was developed for a 30 cm Engineering Model Mercury Ion Thruster. The network consists of approximately 100 nodes coded in SINDA format for use on the Univac 1106/1108 computer. This model takes into account internal dissipation, radiation, and conduction as well as environmental heating. A series of tests were performed to simulate a wide range of thermal environments on an operating 30 cm thruster, instrumented to measure the temperature distribution within the thruster. The results of these tests were used to calibrate the analytical model. The analytical model along with comparisons between analytical and experimental results for the various operating conditions are presented.

Oglebay, J. C.↗

A conceptual model for how to design for building envelope characteristics. Impact of thermal comfort intervals and thermal mass on commercial buildings in U.S. climates

The paper presents a simplified conceptual model for energy demand calculations based on building envelope characteristics, thermal mass and local climate. It is based on a network model and lumped analysis of the dynamic process. Characteristic parameters for the buildings are suggested; Driving temperature (DT), Driving temperature difference, (DTD), External Load Temperature (ELT), and Thermal Load Resistance (TLR). The Building Envelope Performance ( BEP 0 ), based on a controlled constant indoor temperature is introduced. Solution techniques using stable explicit forward differences based on analytical solutions are derived. The conceptual model has been used for mapping the Driving temperature difference and introduced two performance factors and . The first factor represents the effect of thermal comfort interval and thermal mass on the energy demand. The latter represents the ratio between cooling and heating energy demand. These three parameters and factors have been visualized on U.S. maps and enable a possibility to communicate the demand of energy, and cooling and the coupling to building characteristics, in a concise way.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ambient and Initial Temperature Effects on Energy Consumption Rate Modeled in FASTSim

Ambient and initial temperatures significantly impact the energy consumption rate (ECR) of battery electric vehicles (BEVs) due to auxiliary loads and the temperature dependence of battery efficiency. This study introduces a streamlined, physics-based thermal modeling approach within the FASTSim tool that bridges the gap between oversimplified constant-load models and computationally expensive high-fidelity simulations. By employing a lumped thermal mass framework, the model captures fundamental energy balances and critical non-linear energy penalties while maintaining the computational efficiency required for expansive sensitivity studies. The simulations evaluated a compact BEV hatchback with a resistive heater over city (UDDS) and highway (HWFET) test cycles. Compared to a 22 degrees Celsius initial and ambient temperature baseline, a -7 degrees Celsius initial/ambient temperature resulted in a 221% increase in the ECR for the city cycle and a 100% increase for the highway cycle. Conversely, a 45 degrees Celsius initial / 40 degrees Celsius ambient temperature resulted in a 40% increase for UDDS and an 18% increase for HWFET. These results demonstrate that while cold conditions impose the most severe energy penalties due to resistive heating, the impact is consistently more pronounced in city driving where auxiliary loads represent a larger proportion of total energy. This lightweight yet robust framework enables researchers to rapidly quantify BEV thermal sensitivity across diverse climates without the need for high-overhead simulation environments.

33 ADVANCED PROPULSION SYSTEMS↗

Thermal analytical model of a 30 cm mercury ion thruster

A lumped parameter thermal nodal network has been developed for a 30 cm engineering model mercury ion thruster. The network consists of approximately 100 nodes coded in SINDA format for use on the Univac 1106/1108 computer. This model takes into account internal dissipation, radiation, and conduction as well as environmental heating. A series of tests were performed at NASA-Lewis Research Center to simulate a wide range of thermal environments on an operating 30 cm thruster, instrumented to measure the temperature distribution within the thruster. The results of these tests were used to calibrate the analytical model. Presented in this paper are a description of the analytical model along with comparisons between analytical and experimental results for the various operating conditions.

Oglebay, J. C.↗

Thermal analysis of a hypersonic wing test structure

The three-dimensional finite element modeling techniques developed for the thermal analysis of a hypersonic wing test structure (HWTS) are described. The computed results are compared to measured test data. In addition, the results of a NASA two-dimensional parameter finite difference local thermal model and the results of a contractor two-dimensional lumped parameter finite difference local thermal model will be presented.

Sandlin, Doral R.↗

Spacecraft thermal environments.

Definitions are given for spacecraft-surface thermal environment characteristics. Lumped-parameter thermal network modeling techniques are derived for spacecraft thermal environment analysis. The application of these techniques to thermal/vacuum testing is described. A major computer program required by these techniques is outlined. It is noted that this approach has been used to determine thermal environments for the Skylab ATM.

Chapter, J. J.↗

Aerospace applications of SINDA/FLUINT at the Johnson Space Center

SINDA/FLUINT has been found to be a versatile code for modeling aerospace systems involving single or two-phase fluid flow and all modes of heat transfer. Several applications of SINDA/FLUINT are described in this paper. SINDA/FLUINT is being used extensively to model the single phase water loops and the two-phase ammonia loops of the Space Station Freedom active thermal control system (ATCS). These models range from large integrated system models with multiple submodels to very detailed subsystem models. An integrated Space Station ATCS model has been created with ten submodels representing five water loops, three ammonia loops, a Freon loop and a thermal submodel representing the air loop. The model, which has approximately 800 FLUINT lumps and 300 thermal nodes, is used to determine the interaction between the multiple fluid loops which comprise the Space Station ATCS. Several detailed models of the flow-through radiator subsystem of the Space Station ATCS have been developed. One model, which has approximately 70 FLUINT lumps and 340 thermal nodes, provides a representation of the ATCS low temperature radiator array with two fluid loops connected only by conduction through the radiator face sheet. The detailed models are used to determine parameters such as radiator fluid return temperature, fin efficiency, flow distribution and total heat rejection for the baseline design as well as proposed alternate designs. SINDA/FLUINT has also been used as a design tool for several systems using pressurized gasses. One model examined the pressurization and depressurization of the Space Station airlock under a variety of operating conditions including convection with the side walls and internal cooling. Another model predicted the performance of a new generation of manned maneuvering units. This model included high pressure gas depressurization, internal heat transfer and supersonic thruster equations. The results of both models were used to size components, such as the heaters and gas bottles and also to point to areas where hardware testing was needed.

Ewert, Michael K.↗

Numerical Thermal Model of a 30-cm NSTAR Ion Thruster

A thermal computer model of the NSTAR (Nasa Solar Electric Propulsion Technology Applications Readiness) xenon ion thruster has been produced using a lumped parameter thermal nodal network scheme. This model contains 104 nodes on the thruster and was implemented using SINDA (Systems Improved Numerical Differencing Analyzer) and TRASYS (Thermal Radiation Analyzer System) on various UNIX workstations. The model includes radiation and conduction heat transfer, the effect of plasma interaction on the thruster, and an account for finely perforated surfaces. The model was developed in conjunction with an NSTAR thruster outfitted with approximately 20 thermocouples for thermal testing at the NASA Lewis Research Center. The results of these experiments were used to calibrate and confirm the computer model first without and then with the plasma interaction. The calibrated model was able to predict discharge chamber temperatures to within 10 C of measured temperatures. To demonstrate the ability of the model under various circumstances the heat flux was examined for a thruster operating in the environment of space.

VanNoord, Jon↗