Search NASA⌕ Search

SEARCH · Search NASA

Results for “lumped thermal model”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Validation and Parametric Investigations of an Internal Permanent Magnet Motor Using a Lumped Parameter Thermal Model

One of the key challenges for the electric vehicle industry is to develop high-power-density electric motors. Achieving higher power density requires efficient heat removal from inside the motor. In order to improve thermal management, a multiphysics modeling framework that is able to accurately predict the behavior of the motor, while being computationally efficient, is essential. This paper first presents a detailed validation of a lumped parameter thermal network (LPTN) model of an Internal Permanent Magnet synchronous motor within the commercially available MOTOR-CAD modeling environment. The validation is based on temperature comparison with experimental data and with more detailed finite element analysis (FEA). All critical input parameters of the LPTN are considered in detail for each layer of the stator, especially the contact resistances between the impregnation, liner, laminations, and housing. Finally, a sensitivity analysis for each of the critical input parameters is provided. A maximum difference of 4% - for the highest temperature in the slot-winding and the end-winding - was found between the LPTN and the experimental data. Comparing the results from the LPTN and the FEA model, the maximum difference was 2% for the highest temperature in the slot-winding and end-winding. As for the LPTN sensitivity analysis, the thermal parameter with the highest sensitivity was found to be the liner-to-lamination contact resistance.

42 ENGINEERING↗

Validation and Parametric Investigations Using a Lumped Thermal Parameter Model of an Internal Permanent Magnet Motor

One of the key challenges for the electric vehicle industry is to develop high-power-density electric motors. Achieving higher power density requires efficient heat removal from inside the motor. In order to improve thermal management, a multi-physics modeling framework that is able to accurately predict the behavior of the motor, while being computationally efficient, is essential. This paper first presents a detailed validation of a Lumped Parameter Thermal Network (LPTN) model of an Internal Permanent Magnet (IPM) synchronous motor within the commercially available Motor-CAD® modeling environment. The IPM motor’s stator is studied at steady state, and winding losses are generated by a constant DC current. The validation is based on temperature comparison with experimental data and with more detailed Finite Element Analysis (FEA). All critical input parameters of the LPTN are considered in detail for each layer of the stator, especially the contact resistances between the impregnation, liner, laminations and housing. Finally, a sensitivity analysis for each of the critical input parameters is provided. A maximum difference of 4% — for the highest temperature in the slot windings and the end windings — was found between the LPTN and the experimental data. Comparing the results from the LPTN and the FEA model, the maximum difference was 2% for the highest temperature in the slot windings and end windings. As for the LTPN sensitivity analysis, the thermal parameter with the highest sensitivity was found to be the liner-to-lamination contact resistance. The latter is often ignored in the literature, whereas its impact on temperature rise was found to be more significant than any other contact resistance within the stator.

47 OTHER INSTRUMENTATION↗

Validation and Parametric Investigations Using a Lumped Thermal Parameter Model of an Internal Permanent Magnet Motor: Preprint

One of the key challenges for the electric vehicle industry is to develop high-power-density electric motors. Achieving higher power density requires efficient heat removal from inside the motor. In order to improve thermal management, a multi-physics modeling framework that is able to accurately predict the behavior of the motor, while being computationally efficient, is essential. This paper first presents a detailed validation of a Lumped Parameter Thermal Network (LPTN) model of an Internal Permanent Magnet (IPM) synchronous motor within the commercially available Motor-CAD® modeling environment. The IPM motor’s stator is studied at steady state, and winding losses are generated by a constant DC current. The validation is based on temperature comparison with experimental data and with more detailed Finite Element Analysis (FEA). All critical input parameters of the LPTN are considered in detail for each layer of the stator, especially the contact resistances between the impregnation, liner, laminations and housing. Finally, a sensitivity analysis for each of the critical input parameters is provided. A maximum difference of 4% - for the highest temperature in the slot windings and the end windings - was found between the LPTN and the experimental data. Comparing the results from the LPTN and the FEA model, the maximum difference was 2% for the highest temperature in the slot windings and end windings. As for the LTPN sensitivity analysis, the thermal parameter with the highest sensitivity was found to be the liner-to-lamination contact resistance. The latter is often ignored in the literature, whereas its impact on temperature rise was found to be more significant than any other contact resistance within the stator.

ADVANCED PROPULSION SYSTEMS↗

DEVELOPMENT OF A LUMPED-PARAMETER THERMAL MODEL FOR ELECTRO-HYDRAULIC ACTUATORS

This paper describes a thermal-hydraulic modeling method of a closed-circuit electro-hydraulic actuator (EHA). Despite the high energy efficiency of EHAs, it is always important to assess their cooling requirements, to guarantee that the operating temperature remains within an acceptable range. The method proposed in this paper is based on a lumped parameter approach and simplifies some of the complex heat transfer processes by introducing empirical correction factors. The model is validated by means of temperature measurements on an EHA architecture developed by the author. The good match between the simulation results and experiments confirms the capability of the proposed methodology to predict the temperature performance of the reference EHA under different drive cycles. The paper presents a detailed analysis of the power losses and passive heat dissipation for the reference system. Based on this analysis, the cooling requirements of the EHA are studied.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

A dynamic thermal algal growth model for pilot-scale open-channel raceways

Here this study describes the makeup of and results from a simulation consisting of a lumped thermal model integrated with a dynamic algae growth model to simulate the microalgae productivity of an open-channel raceway cultivation system. The thermal model considers the dynamic effects of weather, light absorption, convective heat transfer, radiation heat transfer, conductive heat transfer, thermal capacitance, and water control strategies. The dynamic algae growth model solves a set of ordinary differential equations consisting of growth functions dependent on incident radiation, temperature, nutrient availability, basal metabolism, and losses due to dark- and photo-respiration. Relative errors in the predicted ash-free dry weight of Nannochloropsis oceanica are 12.5%, -6.1%, and 4.4% for three separate replicates of cultivation cycles (~4.2 m 2 ) performed at AzCATI during the ATP 3 Unified Field Studies in Fall, Spring, and Summer. This research demonstrates that thermal modeling is an essential contributor to the validation of microalgae growth models.

09 BIOMASS FUELS↗

An experimentally validated electro-thermal EV battery pack model incorporating cycle-life aging and cell-to-cell variations

Lithium-ion batteries are used in a wide variety of applications. To meet the power and energy demands of these applications battery packs are composed of hundreds to thousands of cells. The electrical and thermal interactions between cells introduce additional complexity in the pack dynamics. To capture these effects, a battery pack model composed of 192 cells based on a first-generation (2012) Nissan Leaf battery pack is developed in MATLAB/Simulink/Simscape. Here, with this model, we simulate the electrical dynamics (using a first-order equivalent-circuit model), the thermal dynamics (using a first-order lumped-parameter thermal model), and the aging dynamics (using a semi-empirical severity factor-based model) of every cell in the pack and we also create a pack thermal model that explicitly captures the heat exchange between the modules, and the cells contained within, during operation. The models are calibrated and validated, both at the cell and pack level, with experimental data. Two different case studies of this pack model are investigated. In the first case study, an initial, normally-distributed, cell-to-cell capacity variation is introduced and its effect on the pack voltage and module temperatures is studied. In the second case study, we deliberately insert cells with lower than nominal capacity into the pack and we investigate how this type of initial cell-to-cell capacity variation affects the pack’s ability to deliver energy over time. Finally, we also study how parallel-connected cells can reduce the effects of cell-to-cell variations at the expense of increased aging of the pack overall.

25 ENERGY STORAGE↗

A conceptual model for how to design for building envelope characteristics. Impact of thermal comfort intervals and thermal mass on commercial buildings in U.S. climates

The paper presents a simplified conceptual model for energy demand calculations based on building envelope characteristics, thermal mass and local climate. It is based on a network model and lumped analysis of the dynamic process. Characteristic parameters for the buildings are suggested; Driving temperature (DT), Driving temperature difference, (DTD), External Load Temperature (ELT), and Thermal Load Resistance (TLR). The Building Envelope Performance ( BEP 0 ), based on a controlled constant indoor temperature is introduced. Solution techniques using stable explicit forward differences based on analytical solutions are derived. The conceptual model has been used for mapping the Driving temperature difference and introduced two performance factors and . The first factor represents the effect of thermal comfort interval and thermal mass on the energy demand. The latter represents the ratio between cooling and heating energy demand. These three parameters and factors have been visualized on U.S. maps and enable a possibility to communicate the demand of energy, and cooling and the coupling to building characteristics, in a concise way.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Ambient and Initial Temperature Effects on Energy Consumption Rate Modeled in FASTSim

Ambient and initial temperatures significantly impact the energy consumption rate (ECR) of battery electric vehicles (BEVs) due to auxiliary loads and the temperature dependence of battery efficiency. This study introduces a streamlined, physics-based thermal modeling approach within the FASTSim tool that bridges the gap between oversimplified constant-load models and computationally expensive high-fidelity simulations. By employing a lumped thermal mass framework, the model captures fundamental energy balances and critical non-linear energy penalties while maintaining the computational efficiency required for expansive sensitivity studies. The simulations evaluated a compact BEV hatchback with a resistive heater over city (UDDS) and highway (HWFET) test cycles. Compared to a 22 degrees Celsius initial and ambient temperature baseline, a -7 degrees Celsius initial/ambient temperature resulted in a 221% increase in the ECR for the city cycle and a 100% increase for the highway cycle. Conversely, a 45 degrees Celsius initial / 40 degrees Celsius ambient temperature resulted in a 40% increase for UDDS and an 18% increase for HWFET. These results demonstrate that while cold conditions impose the most severe energy penalties due to resistive heating, the impact is consistently more pronounced in city driving where auxiliary loads represent a larger proportion of total energy. This lightweight yet robust framework enables researchers to rapidly quantify BEV thermal sensitivity across diverse climates without the need for high-overhead simulation environments.

33 ADVANCED PROPULSION SYSTEMS↗

Development and Validation of Algorithms That Analyze Communicating Thermostat Data to Identify Enclosure Retrofit Opportunities

Annual energy savings of up to $\$ 4$ to $\$ 5$ billion could be achieved nationwide through basic insulation and heating system retrofits of existing homes. However, current utility energy efficiency programs are costly and challenging to scale. Customer acquisition occurs primarily through energy bill mailers, mass media, and online advertising that lack specificity about home-specific retrofit opportunities, expected energy savings, and cost-effectiveness. Specific retrofit opportunities are identified via on-site home energy assessments (HEAs) that are inconvenient to homeowners, expensive, and of variable accuracy. We developed computational algorithms that automatically analyze communicating thermostat (CT) heating data that could be used to increase the customer uptake of insulation and air sealing energy conservation measures (ECMs) by identifying homes with the most significant retrofit opportunities, estimating post-retrofit energy savings, and formulating home-specific outreach. The algorithms are based on an extended second-order grey-box model that characterizes a building’s thermal response using lumped elements, coupled with an empirical model of infiltration that accounts for both wind and stack effects. The basic parameters of the model correspond to actual physical parameters of the home, i.e., the home’s overall R-value of and the building envelope ACH50. Unlike the conventional approach, which estimates model parameters based on the best fit to the observed time-dependent room temperature, our approach derives correlations between the daily heating system runtime and temperature difference (indoor-outdoor) that are more robust to data quality issues in real-world applications. We also used HEA data for algorithm development and validation. With the help of our utility partners, Eversource and National Grid, we obtained data sets for hundreds of Massachusetts homes. For each home, these data sets included three sets of information anonymized by the utility: (1) CT data (HVAC runtime, room temperature, and, for some vendors, outdoor temperature and wind speed) collected by the CT vendor (one of three) over a heating season, (2) HEA report performed by the HEA vendor (same vendor for all homes), (3) Monthly utility gas bills coincident with the CT data (3 to 24 per home, depending on availability). For some homes, we also obtained blower-door test results. Initially, we applied the algorithms developed to homes with a single CT and then extended them to homes with two CTs by using an equivalent home approach. Finally, we developed algorithms for prediction of energy savings and a methodology of comparing our predictions with those generated by HEAs. The main technical results indicate that we can reliably identify homes with insulation and/or air sealing retrofit opportunities and provide accurate savings predictions. Our hypothesis is that the algorithms could be applied to utility energy efficiency programs to identify homes that could realize significant energy savings from insulation and/or air sealing retrofits. This information could then be used to reach out to those homes with highly customized outreach, thereby delivering increased program energy savings and cost-effectiveness. This would: Significantly increase the uptake rate of on-site HEAs, and Significantly increase the fraction of HEAs resulting in ECM implementation. To test these hypotheses, we designed and conducted a randomized controlled trial (RCT). The RCT results suggest that personal messaging leads to a two- to five-fold increase in the HEA uptake rate.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Machine learning-enhanced MPC for demand flexibility in small commercial buildings: An experimental study

Small- and medium-sized commercial buildings (SMCBs) represent the majority of U.S. commercial building stock and a significant share of peak electricity demand, yet they often lack centralized building automation systems, representing a significant untapped resource for urban energy management. This infrastructure gap makes advanced control implementation challenging, limiting the potential for widespread demand flexibility. Model Predictive Control (MPC) has shown strong potential for load shifting, peak demand reduction, and cost savings, but its effectiveness is hindered by unmeasured disturbances such as internal heat gains. This paper presents a Hybrid MPC framework that integrates a physics-based gray-box building thermal model, identified using a lumped disturbance (LD) approach, with a machine learning (ML) model for forecasting unmeasured disturbances. The hybrid approach is designed for buildings with multiple individually controlled heat pump and thermostat pairs, common in SMCBs, and aims to optimize coordinated scheduling of multiple heat pumps under dynamic electricity pricing while respecting comfort constraints. The methodology is validated through both simulations of case study buildings and experimental studies at a highly-instrumented test facility. Simulation results show that the Hybrid MPC achieves substantial load shifting and peak demand reduction, approaching the performance of an ideal MPC with perfect disturbance knowledge, and outperforming a conventional MPC without disturbance forecasting. In experiments, the Hybrid MPC reduced daily HVAC energy costs by 8.7%, peak-price time load (load shifting) by 41.7%, and peak demand by 29.2% compared to baseline control, demonstrating comparable benefits to the 11.6% cost savings, 42.9% load shifting, and 23.2% peak reduction of the ideal MPC. These results demonstrate that the proposed hybrid modeling approach can significantly improve MPC performance in real-world SMCB applications without requiring additional disturbance measurements.

Demand Flexibility↗

Flow Assisted Evaporative Cooling for Electric Motor

This paper examines a novel concept of flow assisted latent heat driven two-phase evaporative cooling (EC) confined in-between slot liner and active-winding of electric motor. Wicking micro-structure enhanced PDMS liner axially sucks coolant in the form of thin film between the PDMS liner and active-winding and eventually enables thin film evaporation on the outer surface of the active-winding. Therefore, EC based thermal management eliminates contact resistance between the winding and slot-liner and, enhances the heat extraction from the winding without compromising the electro-magnetic performance. Two-way coupled electro-magnetic (EM) – computational fluid dynamics/heat transfer (CFD/HT) and EM - lumped parameter thermal network (LPTN) models have been developed to assess the electro-thermal performance of the EC under steady and transient conditions. Taking a case study of a 125 kW jacket cooled BMW i3 motor and dielectric coolant FC-84, EC is shown to be capable of handling a maximum steady state rms current density of 26 A/mm2 at a evaporative heat transfer coefficient of 5,000 W/m2.K, which is about 78.7% higher compared to the traditional jacket cooling (JC). In case of EC, a maximum steady state and transient rms current density of 30 A/mm2 (106.2% higher compared to the JC), and 40.8 A/mm2 have been realized by using high thermal conductivity epoxy (1.9 W/m.K) impregnation material. Thermal performance of the EC is also assessed and compared with JC over a dynamic drive cycle. Lastly, a motorette testing has been performed to demonstrate the applicability of the proposed EC method and to validate the developed modeling framework.

42 ENGINEERING↗

Impact of size and thermal gradient on supercooling of phase change materials for thermal energy storage

Phase change material based thermal energy storage has many current and potential applications in the heating and cooling of buildings, battery and electronics thermal management, thermal textiles, and dry cooling of power plants. However, connecting lab scale thermal data obtained with differential scanning calorimetry (DSC) to the performance of large-scale practical systems has been a major challenge primarily due to the dependence of supercooling on the size and temperature gradient of the system. Here we show how a phase change material’s supercooling behavior can be characterized experimentally using common lab scale thermal analysis techniques. We then develop a statistics based theoretical model that uses the lab-scale data on small samples to quantitatively predict the supercooling performance for a general thermal energy storage application of any size, including also allowing for the possibility of temperature gradients. Finally, we validate the modeling methodology by comparing to experimental results for solid-solid phase change in neopentyl glycol, which shows how the model successfully predicts the changes in supercooling temperature across a large range of cooling rates (2 orders of magnitude) and volumes (3 orders of magnitude). By accounting for thermal gradients, the model avoids ~2x error incurred by lumped approximations.

36 MATERIALS SCIENCE↗

A Reduced-Order Model of a Nuclear Power Plant with Thermal Power Dispatch

This paper presents reduced-order modeling of thermal power dispatch (TPD) from a pressurized water reactor (PWR) for providing heat to nearby heat consuming industrial processes that seek to take advantage of nuclear heat to reduce carbon emissions. The reactor model includes the neutronics of the reactor core, thermal–hydraulics of the primary coolant cycle, and a three-lump model of the steam generator (SG). The secondary coolant cycle is represented with quasi-steady state mass and energy balance equations. The secondary cycle consists of a steam extraction system, high-pressure and low-pressure turbines, moisture separator and reheater, high-pressure and low-pressure feedwater heaters, deaerator, feedwater and condensate pumps, and a condenser. The steam produced by the SG is distributed between the turbines and the extraction steam line (XSL) that delivers steam to nearby industrial processes, such as production of clean hydrogen. The reduced-order simulator is verified by comparing predictions with results from separate validated steady-state and transient full-scope PWR simulators for TPD levels between 0% and 70% of the rated reactor power. All simulators indicate that the flow rate of steam in the main steam line and turbine systems decrease with increasing TPD, which causes a reduction in PWR electric power generation. The results are analyzed to assess the impact of TPD on system efficiency and feedwater flow control. Due to the simplicity of the proposed reduced-order model, it can be scaled to represent a PWR of any size with a few parametric changes. In the future, the proposed reduced-order model will be integrated into a power system model in a digital real-time simulator (DRTS) and physical hardware-in-the-loop simulations.

08 HYDROGEN↗

Gas Generation Models for Thermal Runaway in Lithium Ion Batteries

A numerical model is implemented to study cell venting, internal pressure, and gas-phase dynamics behavior of Li-ion cells undergoing thermal runaway. A k-ɛ Reynolds-Averaged Navier-Stokes (RANS) model is adopted to describe the turbulent flow out of the cells, while the fluid dynamics inside the cells is described by Darcy-Forchheimer’s equation. Thermal abuse reactions and gas generation kinetics are described by a single-step lumped reaction model. A series of computational fluid dynamics (CFD) simulations are conducted on a single cell at various states-of-charge (100%, 50%, 25%) to demonstrate detailed flow and thermal behavior as a function of quantity of gas generated during cell venting. Venting events are categorized into two stages: i) breaching of the cell container and ii) thermal runaway reactions. It is shown that the cell response is dominated by the second stage since most of the gases are generated during thermal runaway. Also, the propensity for propagation is highly affected by state-of-charge (SOC). Cells at higher SOCs produce more heat and gas during the venting event, owing to higher mass and concentrations of reacting gases, and consequently reach higher internal cell pressures which increase the risk of side-wall breaching.

Kim, Jinyong↗

Modeling cell venting and gas-phase reactions in 18650 lithium ion batteries during thermal runaway

A numerical model is developed to study cell venting, internal pressure, and gas-phase dynamics behavior of 18650 Li-ion cells undergoing thermal runaway. A k-e Reynolds-Averaged Navier-Stokes (RANS) model is adopted to describe the turbulent flow out of the cells, while the fluid dynamics inside the cells is described by Darcy-Forchheimer's equation. Thermal abuse reactions and gas generation kinetics are described by a single-step lumped reaction model. Then, a series of computational fluid dynamics (CFD) simulations are conducted on a single 18650 cell at various states-of-charge (100%, 50%, 25%) to study detailed flow and thermal behavior as a function of quantity of gas generated during cell venting. Venting events are categorized into two stages: i) breaching of the cell container and ii) thermal runaway reactions. It is found that the cell response is dominated by the second stage since most of the gases are generated during thermal runaway. Also, the propensity for propagation is highly affected by state-of-charge (SOC). Cells at higher SOCs produce more heat and gas during the venting event, owing to higher mass and concentrations of reacting gases, and consequently reach higher internal cell pressures which increase the risk of side-wall breaching.

25 ENERGY STORAGE↗

Design of a prototypical natural circulation water-based reactor cavity cooling system (RCCS) for a pebble-bed generic FHR

A prototypical natural circulation water-based reactor cavity cooling system (RCCS) for the UC Berkeley Mark-1 pebble-bed gFHR is designed based on one-dimensional thermal hydraulics modeling and optimization implemented in an in-house MATLAB code. The model employs a lumped core consisting of fuel pebble and graphite pebble regions, while the graphite reflector, vessel, and RCCS are represented as separate but energy-coupled regions. The model is derived based on steady state energy balance equations accounting for conductive heat transfer from the lumped core to the vessel and subsequent radiative heat transfer to the RCCS and convective heat transfer in the water. Further, mass flow rate is calculated based on momentum and thermal energy balance in the RCCS. Starting with ANL’s water NSTF as baseline, effects of RCCS design parameters such as size of the plate between pipes, pipe diameter, source-to-sink distance, surface emissivity, and pitch from the core are examined in an integral effects framework which accounts for subsequent variation of the mass flow rate, number of pipes, convection coefficient, mean region and surface temperatures, radiative view factors, and water outlet temperature. The importance of including a prototypical reactor design in RCCS design calculations is emphasized as the calculations show that temperature drops from the core to the RCCS fluid to transfer the heat tend to be the limitation not the heat removal capacity of the fluid. A closed-loop design is obtained with capability to safely remove up to 0.72% of the nominal reactor power at maximum estimated peak conditions and 0.40% at shutdown. The design is based on physics calculations and does not account for economic optimization.

21 SPECIFIC NUCLEAR REACTORS AND ASSOCIATED PLANTS↗

Greybox Thermal Parameter Identification of Electric Machine Stators

The parameters of electric machine thermal equivalent circuit networks are difficult to predict due to material and manufacturing uncertainties. In this paper, a Greybox system identification approach is used to identify parameters of electric machine stator lumped parameter thermal networks (LPTNs). LPTNs provide a low order, computationally efficient, dynamic model of temperatures at specific locations. Second and third order LPTN model structures are defined as state space equations with stator thermal parameters to be identified. To test the Greybox electric machine stator thermal system identification, five stator motorette prototypes were constructed with controlled variations in slot fill and slot liner thickness. The variation in the motorette thermal parameters and thermal time constants are detected using the Greybox identification. Special attention is given to the impact of sampling rate and Greybox data record length on parameter estimation accuracy.

33 ADVANCED PROPULSION SYSTEMS↗

Temperature Homogeneity under Selective and Localized Microwave Heating in Structured Flow Reactors

Selective heating of different phases of multiphase systems via microwaves can result in energy savings and suppression of side reactions. However, materials properties and operating conditions that maximize temperature gradients are poorly understood. Here we utilize computational fluid dynamics (CFD) computations and temperature measurements in structured flow reactors (monoliths) in a monomodal microwave cavity to assess the temperature difference between the walls and the fluid and develop a simple lumped model to estimate when temperature gradients exist. We also explore the material’s thermal and electrical properties of structured reactors for isothermal catalyst conditions. We propose that CFD simulations can be used as a nonintrusive, predictive tool of temperature homogeneity. Importantly, we demonstrate that localized heating in the bed under several conditions rather than selective heating is responsible for the selectivity enhancement. Furthermore, our results indicate that structured beds made of high thermal conductivity materials avoid arcing and enable temperature homogeneity and low electrical conductivity materials allow microwaves to penetrate the domain.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗