Search NASA⌕ Search

SEARCH · Search NASA

Results for “mCA”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

International Space Station (ISS) Major Constituent Analyzer (MCA) On-Orbit Performance

The Major Constituent Analyzer (MCA) is an essential part of the International Space Station (ISS) environmental control and life support system. The analyzer provides continuous readout of the partial pressures of six gases, nitrogen (N2), oxygen (O2), hydrogen (H2), carbon dioxide (CO2), methane (CH4) and water vapor (H2O) in the various ISS US. on-orbit modules. Continuous readout of the partial pressures of these gases is critical to verifying safe operation of the Atmosphere Revitalization (AR) system, Atmosphere Control System (ACS), and crew safety for Airlock Extravehicular Activities (EVAs). The MCA encountered some operational interruptions since being launched to orbit on Flight 5A in February 2001. Electronic, software, and hardware modifications and on-orbit crew maintenance of the MCA were necessary to restore its capability. This paper describes the modifications and the on-orbit maintenance performed to return the MCA to operational status, including brief explanations of the MCA failures and the associated hardware and electronic modifications. Operational procedures that were required to return the MCA to operational status, and the more recent successes of supporting both Russian and U.S. ISS EVA preparations, are also discussed

Reysa, Richard↗

Geotail MCA plasma wave data analysis

NASA Grant NAG 5-2346 supports the data analysis effort at The University of Iowa for the GEOTAIL Multi-Channel Analyzer (MCA) which is a part of the GEOTAIL Plasma Wave Instrument (PWI). At the beginning of this reporting period we had just begun to receive our GEOTAIL Sirius data on CD-ROMs. Much programming effort went into adapting and refining the data analysis programs to include the CD-ROM inputs. Programs were also developed to display the high-frequency-resolution PWI Sweep Frequency Analyzer (SFA) data and to include in all the various plot products the electron cyclotron frequency derived from the magnitude of the magnetic field extracted from the GEOTAIL Magnetic Field (MGF) data included in the GEOTAIL Sirius data. We also developed programs to use the MGF data residing in the Institute of Space and Astronautical Science (ISAS) GEOTAIL Scientific Data Base (SDB). Our programmers also developed programs and provided technical support for the GEOTAIL data analysis efforts of Co-lnvestigator William W. L. Taylor at Nichols Research Corporation (NRC). At the end of this report we have included brief summaries of the NRC effort and the progress being made.

Anderson, Roger R.↗

Evaluation of AK-225(R), Vertrel(R) MCA and HFE A 7100 as Alternative Solvents for Precision Cleaning and Verification Technology

The National Aeronautics and Space Administration (NASA), Kennedy Space Center (KSC) Materials Science Division conducted a study to evaluate alternative solvents for CFC-113 in precision cleaning and verification on typical samples that are used in the KSC environment. The effects of AK-225(R), Vertrel(R), MCA, and HFE A 7100 on selected metal and polymer materials were studied over 1, 7 and 30 day test times. This report addresses a study on the compatibility aspects of replacement solvents for materials in aerospace applications.

Orlando Melendez↗

Geotail MCA Plasma Wave Investigation Data Analysis

The goals of this program include identifying, studying, and understanding the source, movement, and dissipation of plasma mass, momentum, and energy between the Sun and Earth. The GEOTAIL spacecraft was built by the Japanese Institute of Space and Aeronautical Science and has provided extensive measurements of entry, storage, acceleration, and transport in the geomagnetic tail. Due to the GEOTAIL trajectory, which kept the spacecraft passing into the deep tail, GEOTAIL also made 'magnetopause skimming passes' which allowed measurements in the outer magnetosphere, magnetopause, bow shock, and upstream solar wind regions as well as in the lobe, magnetosheath, boundary layers, and central plasma sheet regions of the tail. In late 1994, after spending nearly 30 months primarily traversing the deep tail region, GEOTAIL began its near Earth phase where apogee was reduced first to about 50 Re and later to 30 Re and perigee was decreased to about 10 Re. The WIND spacecraft was launched on November 1, 1994, and the POLAR spacecraft was launched on February 24, 1996. These successful launches have dramatically increased the opportunities for GEOTAIL and the GGS spacecraft to conduct global research.

Anderson, Roger R.↗

Geotail MCA Plasma Wave Investigation Data Analysis

The primary goals of the International Solar Terrestrial Physics/Global Geospace Science (ISTP/GGS) program are identifying, studying, and understanding the source, movement, and dissipation of plasma mass, momentum, and energy between the Sun and the Earth. The GEOTAIL spacecraft was built by the Japanese Institute of Space and Astronautical Science and has provided extensive measurements of entry, storage, acceleration, and transport in the geomagnetic tail and throughout the Earth's outer magnetosphere. GEOTAIL was launched on July 24, 1992, and began its scientific mission with eighteen extensions into the deep-tail region with apogees ranging from around 60 R(sub e) to more than 208 R(sub e) in the period up to late 1994. Due to the nature of the GEOTAIL trajectory which kept the spacecraft passing into the deep tail, GEOTAIL also made 'magnetopause skimming passes' which allowed measurements in the outer magnetosphere, magnetopause, magnetosheath, bow shock, and upstream solar wind regions as well as in the lobe, magnetosheath, boundary layers, and central plasma sheet regions of the tail. In late 1994, after spending nearly 30 months primarily traversing the deep tail region, GEOTAIL began its near-Earth phase. Perigee was reduced to 10 R(sub e) and apogee first to 50 R(sub e) and finally to 30 R(sub e) in early 1995. This orbit provides many more opportunities for GEOTAIL to explore the upstream solar wind, bow shock, magnetosheath, magnetopause, and outer magnetosphere as well as the near-Earth tail regions. The WIND spacecraft was launched on November 1, 1994 and the POLAR spacecraft was launched on February 24, 1996. These successful launches have dramatically increased the opportunities for GEOTAIL and the GGS spacecraft to be used to conduct the global research for which the ISTP program was designed. The measurement and study of plasma waves have made and will continue to make important contributions to reaching the ISTP/GGS goals and solving the significant problems of sun-earth connections. Plasma waves are involved in the energization and de-energization of plasma and energetic particles via numerous wave-particle interaction processes. Plasma waves in many instances are the source for the heating or cooling of the particles. They can cause particle precipitation by scattering particles into the loss cone. They move particles across boundaries in mass and energy dependent ways. Identifying the waves and the instabilities which produce them are thus crucial for understanding the plasma processes. Wave-particle interaction processes are especially important at various boundaries between the different regions of geospace including the bow shock, magnetopause, and interfaces in the geomagnetic tail between the magnetosheath, lobe, plasmasheet, boundary layers, and neutral sheet. In addition to identifying the characteristics of the instabilities and generation mechanisms encountered, plasma wave measurement are used in conjunction with other fields and particle measurements to identify the region of space the spacecraft is in or the boundary that is being crosed.

Anderson, Roger R.↗

An idealized model for the crystal structure of intermetallic compounds isostructural with Mg 3 Cr 2 Al 18

Mg 3 Cr 2 Al 18 (abbreviated in this report as MCA) is the parent phase for a large class of intermetallic compounds that belong to the cubic crystal space group, $Fd\overline{3}m$. The purpose of this paper is to introduce an ideal, unrelaxed crystal structure for compounds isostructural with MCA. There are five distinct atomic sublattices in MCA compounds, which can be denoted, $A, B, C, D,$ and $E$. With this, a general description for MCA structures can be written as $A^{8a}_{1}B^{16c}_{2}C^{16d}_{2}D^{48f}_{6}E^{96g}_{12}$, where the superscripts represent the Wyckoff special equipoints associated with the various sublattices in MCA, and the subscripts indicate the contributions of each sublattice to the stoichiometry of one formula unit in an any given MCA structured compound. Sublattices D and E are where deviations from ideality occur in real, MCA-like compounds. This paper examines MCA bond lengths, nearest-neighbour polyhedral arrangements, 3-D sublattice crystal structures, 2-D atom tessellation patterns, and crystal chemical effects associated with atomic relaxations on the $D$ and $E$ sublattices. The ideal MCA crystal structure developed in this report provides an appropriate initial structure for use as input to crystal structure refinements of diffraction data for MCA-like phases being examined experimentally, or as input for computational, atomistic simulations of the structures of such compounds.

36 MATERIALS SCIENCE↗

Robustness of magnetocrystalline anisotropy and coercivity in Fe–Co–B

As a potential candidate for critical chemical element free permanent magnet, (Fe 0.7 Co 0.3 ) 2 B, shows promising intrinsic magnetic properties, including large magnetization, high Curie temperature and moderate magnetocrystalline anisotropy (MCA). Still, the coercivity that has been achieved is relatively low. To understand and improve coercivity, here we study the robustness of MCA related to the fluctuation of chemical composition and the structural distortion and its effect on coercivity in (Fe 0.7 Co 0.3 ) 2 B from first principles DFT (density functional theory) calculation and micromagnetic simulation. A fluctuation of cobalt content of 10%, or 1% isotropic lattice strain, or 2% tetragonal distortion reduces MCA energy up to 30%. By considering randomly distributed local MCA energy reduction up to 30%, the calculated coercivity of anisotropic bulk magnets reduced from 3.6 kOe to 2.2 kOe. Rational microstructure design, such as grain size refinement and development of strong crystal texture of MCA easy-axis (i.e., degree of alignment for (Fe 0.7 Co 0.3 ) 2 B grains), can enhance coercivity and mitigate the effect of local MCA reduction. In addition to acceptable intrinsic magnetic properties, the promising hard magnetic phase needs good MCA robustness to facilitate the development of practical magnets.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Paternal preconception alcohol consumption increased Angiotensin II‐mediated vasoconstriction in male offspring cerebral arteries via oxidative stress‐AT1R pathway

Abstract Alcohol consumption is popular worldwidely and closely associated with cardiovascular diseases. Influences of paternal preconception alcohol consumption on offspring cerebral arteries are largely unknown. Male rats were randomly given alcohol or water before being mated with alcohol‐naive females to produce alcohol‐ and control‐sired offspring. Middle cerebral artery (MCA) was tested with a Danish Myo Technology wire myograph, patch‐clamp, IONOPTIX, immunofluorescence and quantitative PCR. Alcohol consumption enhanced angiotensin II (AngII)‐mediated constriction in male offspring MCA mainly via AT1R. PD123,319 only augmented AngII‐induced constriction in control offspring. AngII and Bay K8644 induced stronger intracellular calcium transient in vascular smooth muscle cells (VSMCs) from MCA of alcohol offspring. L‐type voltage‐dependent calcium channel (L‐Ca 2+ ) current at baseline and after AngII‐stimulation was higher in VSMCs. Influence of large‐conductance calcium‐activated potassium channel (BK C a ) was lower. Caffeine induced stronger constriction and intracellular calcium release in alcohol offspring. Superoxide anion was higher in alcohol MCA than control. Tempol and thenoyltrifluoroacetone alleviated AngII‐mediated contractions, while inhibition was significantly higher in alcohol group. The mitochondria were swollen in alcohol MCA. Despite lower Kcnma1 and Prkce expression, many genes expressions were higher in alcohol group. Hypoxia induced reactive oxygen species production and increased AT1R expression in control MCA and rat aorta smooth muscle cell line. In conclusion, this study firstly demonstrated paternal preconception alcohol potentiated AngII‐mediated vasoconstriction in offspring MCA via ROS‐AT1R. Alcohol consumption increased intracellular calcium via L‐Ca 2+ channel and endoplasmic reticulum and decreased BK Ca function. The present study provided new information for male reproductive health and developmental origin of cerebrovascular diseases.

Zhang, Ze↗

International Space Station Major Constituent Analyzer On-Orbit Performance

The Major Constituent Analyzer (MCA) is an integral part of the International Space Station (ISS) Environmental Control and Life Support System (ECLSS). The MCA is a mass spectrometer-based instrument designed to provide critical monitoring of six major atmospheric constituents; nitrogen, oxygen, hydrogen, carbon dioxide, methane, and water vapor. These gases are sampled continuously and automatically in all United States On-Orbit Segment (USOS) modules via the Sample Distribution System (SDS). The MCA is the primary tool for management of atmosphere constituents and is therefore critical for ensuring a habitable ISS environment during both nominal ISS operations and campout EVA preparation in the Airlock. The MCA has been in operation in the US Destiny Laboratory Module for over 10 years, and a second MCA has been delivered to the ISS for Node 3 operation. This paper discusses the performance of the MCA over the two past year, with particular attention to lessons learned regarding the operational life of critical components. Recent data have helped drive design upgrades for a new set of orbit-replaceable units (ORUs) currently in production. Several ORU upgrades are expected to increase expected lifetimes and reliability.

Gardner, Ben D.↗

Alternative, Green Processes for the Precision Cleaning of Aerospace Hardware

Precision cleaning is necessary to ensure the proper functioning of aerospace hardware, particularly those systems that come in contact with liquid oxygen or hypergolic fuels. Components that have not been cleaned to the appropriate levels may experience problems ranging from impaired performance to catastrophic failure. Traditionally, this has been achieved using various halogenated solvents. However, as information on the toxicological and/or environmental impacts of each came to light, they were subsequently regulated out of use. The solvent currently used in Kennedy Space Center (KSC) precision cleaning operations is Vertrel MCA. Environmental sampling at KSC indicates that continued use of this or similar solvents may lead to high remediation costs that must be borne by the Program for years to come. In response to this problem, the Green Solvents Project seeks to develop state-of-the-art, green technologies designed to meet KSCs precision cleaning needs.Initially, 23 solvents were identified as potential replacements for the current Vertrel MCA-based process. Highly halogenated solvents were deliberately omitted since historical precedents indicate that as the long-term consequences of these solvents become known, they will eventually be regulated out of practical use, often with significant financial burdens for the user. Three solvent-less cleaning processes (plasma, supercritical carbon dioxide, and carbon dioxide snow) were also chosen since they produce essentially no waste stream. Next, experimental and analytical procedures were developed to compare the relative effectiveness of these solvents and technologies to the current KSC standard of Vertrel MCA. Individually numbered Swagelok fittings were used to represent the hardware in the cleaning process. First, the fittings were cleaned using Vertrel MCA in order to determine their true cleaned mass. Next, the fittings were dipped into stock solutions of five commonly encountered contaminants and were weighed again showing typical contaminant deposition levels of approximately 0.00300g per part. They were then cleaned by the solvent or process being tested and then weighed a third time which allowed for the calculation of the cleaning efficiency of the test solvent or process.Based on preliminary experiments, five solvents (ethanol, isopropanol, acetone, ethyl acetate, and tert-butyl acetate) were down selected for further testing. When coupled with ultrasonic agitation, these solvents removed hydrocarbon contaminants as well as Vertrel MCA and showed improved removal of perfluorinated greases. Supercritical carbon dioxide did an excellent job dissolving each of the five contaminants but did a poor job of removing Teflon particles found in the perfluorinated greases. Plasma cleaning efficiency was found to be dependent on which supply gas was used, exposure time, and gas pressure. Under optimized conditions it was found that breathing air, energized to the plasma phase, was able to remove nearly 100% of the contamination.These findings indicate that alternative cleaning methods are indeed able to achieve precision levels of cleanliness. Currently, our team is working with a commercial cleaning company to get independent verification of our results. We are also evaluating the technical and financial aspects of scaling these processes to a size capable of supporting the future cleaning needs of KSC.

Vertrel MCA↗

Hard and semi-hard Fe-based magnetic materials

Iron (Fe) is the most important ferromagnetic element, not only for its high magnetic moment and high Curie temperature but for its abundance as well. Fe-based magnetic materials are therefore widely applied in technologies and industries, with most of the applications for soft magnetic materials, because of the low magnetocrystalline anisotropy (MCA) of Fe. However, it is possible to realize magnetic hardening in Fe-based materials as we have learned from the early carbon steel permanent magnets although their coercivity was modest. Recent efforts to search for rare-earth-free hard magnetic materials have shown more promising evidences for achieving high MCA in Fe-based materials. In this paper, we review the history and the recent developments of Fe-based hard and semi-hard magnetic materials with a focus on mechanisms of high MCA in Fe-based phases and the related crystal and electronic structures. Here, we have tabulated and discussed the structures and the magnetic properties of the Fe-based binary or ternary systems containing p-block and d-block elements, with many of them showing considerable MCA. Furthermore, it is important to know and to understand that the MCA in Fe-based magnetic materials can be tailored/enhanced through chemical and/or structural modifications that will lead to “artificially engineered” hard and semi-hard magnetic materials for advanced permanent magnets in the future.

36 MATERIALS SCIENCE↗

Cerebral blood velocity and other cardiovascular responses to 2 days of head-down tilt

Spaceflight induces a cephalad redistribution of fluid volume and blood flow within the human body, and space motion sickness, which is a problem during the first few days of space flight, could be related to these changes in fluid status and in blood flow of the cerebrum and vestibular system. To evaluate possible changes in cerebral blood flow during simulated weightlessness, we measured blood velocity in the middle cerebral artery (MCA) along with retinal vascular diameters, intraocular pressure, impedance cardiography, and sphygmomanometry on nine men (26.2 +/- 6.6 yr) morning and evening for 2 days during continuous 10 deg head-down tilt (HDT). When subjects went from seated to head-down bed rest, their heart rate and retinal diameters decreased, and intraocular pressures increased. After 48 h of HDT, blood flow velocity in the MCA was decreased and thoracic impedance was increased, indicating less fluid in the thorax. Percent changes in blood flow velocities in the MCA after 48 h of HDT were inversely correlated with percent changes in retinal vascular diameters. Blood flow velocities in the MCA were inversely correlated (intersubject) with arterial pressures and retinal vascular diameters. Heart rate, stroke volume, cardiac output, systolic arterial pressure, and at times pulse pressure and blood flow velocities in the MCA were greater in the evening. Total peripheral resistance was higher in the morning. Although cerebral blood velocity is reduced after subjects are head down for 2 days, the inverse relationship with retinal vessel diameters, which have control analogous to that of cerebral vessels, indicates cerebral blood flow is not reduced.

Frey, Mary A. B.↗

Relationship of 133Xe cerebral blood flow to middle cerebral arterial flow velocity in men at rest

Cerebral blood flow (CBF) was measured by 133Xe clearance simultaneously with the velocity of blood flow through the left middle cerebral artery (MCA) over a wide range of arterial PCO2 in eight normal men. Average arterial PCO2, which was varied by giving 4% and 6% CO2 in O2 and by controlled hyperventilation on O2, ranged from 25.3 to 49.9 mm Hg. Corresponding average values of global CBF15 were 27.2 and 65.0 ml 100 g min-1, respectively, whereas MCA blood-flow velocity ranged from 42.8 to 94.2 cm/s. The relationship of CBF to MCA blood-flow velocity over the imposed range of arterial PCO2 was described analytically by a parabola with the equation: CBF = 22.8 - 0.17 x velocity + 0.006 x velocity2 The observed data indicate that MCA blood-flow velocity is a useful index of CBF response to change in arterial PCO2 during O2 breathing at rest. With respect to baseline values measured while breathing 100% O2 spontaneously, percent changes in velocity were significantly smaller than corresponding percent changes in CBF at increased levels of arterial PCO2 and larger than CBF changes at the lower arterial PCO2. These observed relative changes are consistent with MCA vasodilation at the site of measurement during exposure to progressive hypercapnia and also during extreme hyperventilation hypocapnia.

NASA Discipline Cardiopulmonary↗

Investigation of International Space Station Major Constituent Analyzer Anomalous ORU 02 Performance

The Major Constituent Analyzer (MCA) is a mass spectrometer-based instrument designed to provide critical monitoring of six major atmospheric constituents; nitrogen, oxygen, hydrogen, carbon dioxide, methane, and water vapor on-board the International Space Station. It is an integral part of the Environmental Control and Life Support System (ECLSS). The MCA system is comprised of seven orbit-replaceable units (ORUs) that provide flexibility in maintaining the MCA. Of these, ORU 02, the analyzer assembly requires replacement every 1 to 2 years due to the consumption of limited life components including the ion pump and ion source filaments. Typically, ORU 02s that reach end of life are swapped out of the MCA on orbit and replaced with the on-orbit spare. The replaced ORU 02 is then returned to the OEM for refurbishment and is then return to service. Recently, 2 refurbished ORU 02s, serial numbers F0001 and F0003, failed on orbit shortly after being installed into the MCA. Both ORU 02s have been returned to ground for TT&E, and a failure investigation is underway. The failure signatures have been reproduced on the ground and an initial investigation has determined that both ORU 02 failures involve either the ion source or the ion source control electronics. This paper discusses the results of the failure investigation, the steps required to refurbish the ORU 02s, and the risk mitigation steps that are being incorporated into the refurbishment process to preclude the reoccurrence of these failures in the future

Gardner, Ben D.↗

Investigation of International Space Station Major Constituent Analyzer Anomalous ORU 02 Performance

The Major Constituent Analyzer (MCA) is a mass spectrometer-based instrument designed to provide critical monitoring of six major atmospheric constituents; nitrogen, oxygen, hydrogen, carbon dioxide, methane, and water vapor on-board the International Space Station. It is an integral part of the Environmental Control and Life Support System (ECLSS). The MCA system is comprised of seven orbit-replaceable units (ORUs) that provide flexibility in maintaining the MCA. Of these, ORU 02, the analyzer assembly requires replacement every 1 to 2 years due to the consumption of limited life components including the ion pump and ion source filaments. Typically, ORU 02s that reach end of life are swapped out of the MCA on orbit and replaced with the on-orbit spare. The replaced ORU 02 is then cycled through the OEM for refurbishment and returned to service. Recently, two refurbished ORU 02s, serial numbers F0001 and F0003, failed on orbit shortly after being installed into the MCA. Both ORU 02s were returned to ground for TT&E and a failure investigation. The failure signatures were reproduced on the ground and the investigation determined that both ORU 02 failures involve either the ion source or the ion source control electronics. This paper discusses the results of the failure investigation, the steps required to refurbish the ORU 02s, and the corrective actions that are being incorporated into the build and refurbishment process to preclude the reoccurrence of these failures in the future.

Gardner, Ben D.↗

Integrated ab initio modelling of atomic ordering and magnetic anisotropy for design of FeNi-based magnets

We describe an integrated modelling approach to accelerate the search for novel, single-phase, multicomponent materials with high magnetocrystalline anisotropy (MCA). For a given system we predict the nature of atomic ordering, its dependence on the magnetic state, and then proceed to describe the consequent MCA, magnetisation, and magnetic critical temperature (Curie temperature). Crucially, within our modelling framework, the same ab initio description of a material’s electronic structure determines all aspects. We demonstrate this holistic method by studying the effects of alloying additions in FeNi, examining systems with the general stoichiometries Fe 4 Ni 3 X and Fe 3 Ni 4 X, for additives including X = Pt, Pd, Al, and Co. The atomic ordering behaviour predicted on adding these elements, fundamental for determining a material’s MCA, is rich and varied. Equiatomic FeNi has been reported to require ferromagnetic order to establish the tetragonal L1 0 order suited for significant MCA. Our results show that when alloying additions are included in this material, annealing in an applied magnetic field and/or below a material’s Curie temperature may also promote tetragonal order, along with an appreciable effect on the predicted hard magnetic properties.

36 MATERIALS SCIENCE↗