Search NASASearch

SEARCH · Search NASA

Results for “magnet design and analysis techniques”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Advanced Design for the WIQ Magnet With Steering Corrector Function

The Facility for Rare Isotopes Beams (FRIB) delivers heavy-ion primary beams at energies of up to 300 MeV/u at 10 kW of beam power to generate rare isotope beams for experiments and will eventually operate at beam power of 400 kW. The preseprator of the Advanced Rare Isotope Separator (ARIS) is equipped with six warm-iron quadrupole (WIQ) singlets and two dipoles integrated right after the production target. They have a compact structure and operate in a high radiation vacuum environment within a hot cell having remote handling capabilities for installation and maintenance. Due to asymmetry with respect to the quadrupole poles, nested sextupole excitations in WIQs induce vertical dipoles that offset the centroid trajectory; Magnet misalignments also result in trajectory offsets. Such offsets degrade separator performance but can be minimized by changing the current distribution on sextupole and octupole coils. In this work, we show how modifications to the WIQ coil design can allow superimposed dipole fields to be included to the octupole and sextupole windings, as well as addition of dipole components by splitting coil currents over groups with separator power supplies. Adjusting the group currents can cancel the sextupole-induced vertical dipole component which can be as high as 0.012 Tm. Octupole coil changes may superimpose a horizontal dipole integrated strength as high as 0.0332 Tm. Unwanted higher harmonics induced as a side effect of the new design are kept to a minimum such that separator performance is preserved as much as possible.

Accelerator magnets

A Two-Dimensional Non-Linear Magnetic Equivalent Circuit Model to Facilitate the Preliminary Design of a Normal Conducting Quadrupole

Normal conducting quadrupoles have been used to focus charged particle beams in synchrotrons, beam transfer lines, medical linacs, etc. for a long time. Optimization techniques based on analytical expressions combined with the use of a numerical field analysis tool exist in the literature for the design of an optimal pole tip shape. However, the initial shape and dimensions of the remaining yoke (including the pole itself and yoke base that act as the return path) are usually less well defined. This article discusses a design methodology for a normal conducting quadrupole based on a two-dimensional magnetic equivalent circuit. Here, this approach considers the geometry of the entire magnet and the non-linear behavior of the yoke material, thereby eliminating the initial iterations. The design outcome of this exercise serves as a competent starting point and can then be used to refine the pole tip, pole taper, yoke size, and add other geometrical features to achieve the required field quality, gradient, coil considerations, etc. by employing a finite element analysis tool. An example design study to demonstrate the proposed methodology is presented.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Magnetic Field Mapping Design for the MOLLER Spectrometer Magnets at Jefferson Lab

The Thomas Jefferson National Accelerator Facility (JLab) has developed a unique spectrometer system to study the weak interaction between electrons. The "Measurement of Lepton-Lepton Electroweak Reaction" (MOLLER) experiment, utilizing JLab's recent 12 GeV electron beam upgrade, is scheduled to operate for three years. Central to the MOLLER experiment are five water-cooled toroidal magnets, each with a unique geometry and seven-fold symmetry, designed to focus the particles. These magnets generate the magnetic field needed to separate incident beam electrons scattered from target electrons (Møller scattering) and protons (elastic e-p scattering) within a liquid hydrogen target. Here, this paper details the magnet field measuring technique developed to map all five MOLLER toroidal magnets at multiple locations inside and along the bore. It covers the design, mounting, and operation of the probe, along with the calibration procedure to determine the field and to prepare a field map for GEANT4 analysis. Additionally, the paper addresses the challenges of accurately measuring low magnetic fields.

Ghoshal, Probir K. [Thomas Jefferson National Acce

Fast ionic conduction achieved through the design and synthesis of ceramic heterointerfaces

Lithium (Li) chloride and iron oxychloride (FeOCl), typically nonconductive, were combined to form a [Li 1+δ Cl] δ+ /[FeOCl] δ- heterointerface composite material (LFH), achieving ionic conductivities of >1 mS cm -1 . Analysis techniques (scanning transmission electron microscopy [STEM] and electron energy-loss spectroscopy [EELS]) indicated that the microstructure of LFH consisted of an amorphous LiCl-based shell surrounding a crystalline FeOCl-based core. Electrochemical measurements alongside solid-state 6,7 Li nuclear magnetic resonance (NMR) and molecular dynamic simulations revealed Li+ as the sole conductive species, with a diffusion barrier of ~0.25 eV. X-ray photoelectron spectroscopy (XPS) and X-ray absorption fine structure (XAFS) results further supported interstitial Li + diffusion at the heterointerface and within the LiCl phase, made possible by the heterointerface. Despite susceptibility to electronic conductivity, iron’s defects and multivalency (Fe³⁺, Fe²⁺) enable the Fe–O–Cl framework to accept Cl - , facilitating Li⁺ ionic conduction. Finally, a prototype solid-state cell (showing 97% Coulombic efficiency) demonstrated the viability of this heterointerface design for applications in energy storage.

36 MATERIALS SCIENCE

Design and Analysis of Short Period 2G-HTS Undulators

Recent advancements in second-generation high-temperature superconducting (2G-HTS) materials have opened new possibilities for superconducting undulator (SCU) technology, particularly in achieving shorter periods and higher magnetic fields. Here, this paper presents the design and analysis of a short-period, as small as 10 mm, 2G-HTS undulator, focusing on magnetic performance, mechanical force minimization, and quench protection. A force-balanced coil pack design is introduced to significantly reduce mechanical stresses on the conductors, eliminating the need for heavy support structures. Rapid prototyping techniques such as3D printing is employed to refine the design for scalability and manufacturability. Correction schemes for end-field effects are developed using a combination of 2G-HTS tapes and NbTi conductors to optimize field integrals. Simulation results demonstrated that optimized magnetic performance and enhanced mechanical stability, positioning 2G-HTS undulators as promising candidates for storage ring and free-electron based light sources.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND

Mechanical Design of the PIP-II ORBUMP Pulsed Dipole Magnet

The Proton Improvement Plan II (PIP-II) project is a vital upgrade to the Fermilab accelerator complex. The magnet pulse rate of the PIP-II Injection system requires an increase from the current rate of 15 Hz to 20 Hz as well as a roughly 30% increase in the magnetic field of the new Orbital Bump (ORBUMP) pulsed dipole magnets in the Booster. Here, the ORBUMP magnet mechanical design is presented in this paper. The ORBUMP magnet is secured in a vacuum box and the core is made up of 0.127 mm thick, low carbon steel laminations with a C-5 inorganic magnesium phosphate coating. The core is clamped using external tie bars welded to the core end plates. ANSYS Finite Element Analysis (FEA) was used to evaluate the clamping design to minimize the deflection of the core post welding of the tie bars. The water-cooled, single turn coil, which shapes the magnetic field by acting as the pole tips, is critical for the integrated field homogeneity. The coil manufacturing tolerances and fabrication techniques were evaluated to ensure the magnetic properties of the magnet could be obtained. The coil is electrically isolated from the core using virgin Polyether ether ketone (PEEK) insulating material in the gap. An investigation into the high voltage performance of the virgin PEEK insulator was conducted via partial discharge testing using a 1:1 scale sample.

Karas, D. [Fermi National Accelerator Laboratory (

Describing Function Analysis of Transformer Magnetizing Inductance for Direct Power Control of Back-to-Back Modular Multilevel Converters with Advanced Grid Support

This paper provides a detailed investigation into the application of describing function-based analysis for assessing transformer magnetizing inductance and its impact on system performance. The focus is on a back-to-back modular multilevel converter architecture, designed to interconnect systems operating at different frequencies. The study explores the implementation of a Direct Power Control strategy, examining its effects on transformer magnetizing inductance saturation and offering effective mitigation techniques. Furthermore, the integration of advanced grid support functionalities is highlighted, demonstrating how these enhancements bolster the converter's ability to improve grid stability and power quality, positioning it as a robust solution for modern power systems. The proposed approach is validated through extensive computer simulations based MAT LAB/Simulink domain, supported by significant case study results, confirming its practical effectiveness.

back-to-back modular multilevel converters (B2B- M

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER

Controlling beam trajectory and transport in a tapered helical undulator

In this paper we present a detailed discussion of the helical undulator system developed for high extraction efficiency experiments in the tapered-enhanced stimulated superradiant amplification regime. The design is based on permanent magnet technology and comprises two Halbach arrays orthogonally oriented and shifted by 90° with respect to each other. When used in low energy beamlines for THz generation, the electron beam trajectory and transport are particularly sensitive to the undulator off-axis fields so that it becomes important to complement on-axis field measurements with analysis and tuning of the higher-order field components. Here we describe how the pulsed wire measurement technique can be effectively used to retrieve on- and off-axis magnetic field characteristics of the undulator. A simple two-dipole model is developed to guide the final adjustments to the permanent magnet positions along the array to tune the quadrupole and sextupole components of the field.

free-electron lasers

Fault localization in a microfabricated surface ion trap using diamond nitrogen-vacancy center magnetometry

Here, as quantum computing hardware becomes more complex with ongoing design innovations and growing capabilities, the quantum computing community needs increasingly powerful techniques for fabrication failure root-cause analysis. This is especially true for trapped-ion quantum computing. As trapped-ion quantum computing aims to scale to thousands of ions, the electrode numbers are growing to several hundred, with likely integrated photonic components also adding to the electrical and fabrication complexity, making faults even harder to locate. In this work, we used a high-resolution quantum magnetic imaging technique, based on nitrogen-vacancy centers in diamond, to investigate short-circuit faults in an ion trap chip. We imaged currents from these short-circuit faults to ground and compared them to intentionally created faults, finding that the root cause of the faults was failures in the on-chip trench capacitors. This work, where we exploited the performance advantages of a quantum magnetic sensing technique to troubleshoot a piece of quantum computing hardware, is a unique example of the evolving synergy between emerging quantum technologies to achieve capabilities that were previously inaccessible.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Mechanical Design of the PIP-II ORBUMP Pulsed Dipole Magnet

The Proton Improvement Plan-II (PIP-II) is a vital upgrade to Fermilab's accelerator complex. The upgrade is designed to power the world s most intense high-energy neutrino beam in future experiments. The magnet pulse repetition rate of the PIP-II injection system is being upgraded from 15 Hz to 20 Hz and requires a roughly 30% increase in the magnetic field of the new Orbital Bump (ORBUMP) magnets in the Booster. The magnet is secured in a vacuum box and the core is made up of 0.127 mm thick, low carbon steel laminations with a C-5 inorganic coating. The core is clamped using external tie bars welded to the core end plates. ANSYS Finite Element Analysis (FEA) was used to evaluate the clamping design to minimize the deflection of the core post welding of the tie bars. The water-cooled single turn coil is electrically isolated from the core using virgin PEEK insulating material in the gap. An investigation into the high voltage performance of the virgin PEEK insulator was conducted. The design of the coil which shapes the magnetic field by acting as the pole tips is critical for the integrated field homogeneity. The coil manufacturing tolerances and fabrication techniques were evaluated to ensure the magnetic properties of the magnet could be obtained. The ORBUMP magnet mechanical design is presented in this paper.

Karas, Dino [Fermilab] (ORCID:0000000304340670)

Accelerator Physics at NSLS-II: Research Accomplishments in 2024

NSLS-II accelerator physicists advanced the operational performance and scientific capabilities of NSLS-II, providing regular lattice characterization and correction, injec tion optimization, vertical emittance control, and beam dynamics reports with corre lation analysis. We further developed advanced lattice characterization techniques and studies on impedance, beam-induced heating, and higher-harmonic RF cavity effects to support NSLS-II and its high-brightness upgrade. The assessment of free-electron laser options for the NSLS-II upgrade has been completed. We carried out comprehensive studies focused on complex bend magnets and novel efficient injection schemes for next-generation low-emittance synchrotrons. We contributed to the Electron-Ion Collider project, including Electron Storage Ring lattice design, beam diagnostics, and injector studies. The physicists participated in international collaborations, including the development of Python-based Middle Layer software, and participated in key accel erator physics workshops and scientific meetings. The main research accomplishments achieved in 2024 are summarized in this report.

43 PARTICLE ACCELERATORS

Neural Network Analysis of Nuclear Magnetic Resonance and Infrared Spectra

Nuclear magnetic resonance (NMR) spectroscopy and infrared (IR) spectroscopy are powerful chemical characterization techniques with broad general usage. However, the manual evaluation of the resulting spectra is time-consuming and requires significant expertise, preventing insights from being used in real-time applications. With recent advances in computation and artificial intelligence (AI), new tools are available for automating spectral interpretation. In this work, machine learning (ML) algorithms using 1-dimensional convolutional neural networks (CNNs) were applied to identify common functional groups from spectral information. Raw spectra were collected virtually from the Human Metabolome Database (HMDB) and National Institute of Standards and Technology (NIST) Chemistry WebBook and processed into a suitable standard. Algorithm design was tailored to best fit the nature of the problem, with built-in flexibility to accommodate relevant parameters beyond the raw spectral input, specifically solvent identity and magnetic frequency for NMR. The predictive capability of the algorithm in identifying functional groups is displayed in several examples. This methodology has been compiled into a code repository and could easily be modified to adapt alternative data sources, including other spectrum types. To mitigate overfitting, a common problem in mathematical modeling where overfamiliarity with training data produces trends that are not representative of the general data, a novel metric was developed, referred to as Accufit. Accufit includes a parameter that penalizes substantial differences in the training accuracy and the accuracy of an independent validation set. Examples are presented showing the effectiveness of Accufit in maintaining the model’s predictive capability while controlling the overfitting when used as a custom metric for hyperparameter tuning.

Sturgill, James

Confinement performance predictions for a high field axisymmetric tandem mirror

This paper presents a Hammir tandem mirror confinement performance analysis based on Realta Fusion’s first-of-a-kind model for axisymmetric magnetic mirror fusion performance. This model uses an integrated end plug simulation model including, heating, equilibrium and transport combined with a new formulation of the plasma operation contours (POPCONs) technique for the tandem mirror central cell. Using this model in concert with machine learning optimization techniques, it is shown that an end plug utilizing high temperature superconducting magnets and modern neutral beams enables a classical tandem mirror pilot plant producing a fusion gain Q > 5. The approach here represents an important advance in tandem mirror design. The high-fidelity end plug model enables calculations of heating and transport in the highly non-Maxwellian end plug to be made more accurately. The detailed end plug modelling performed in this work has highlighted the importance of classical radial transport and neutral beam absorption efficiency on end plug viability. The central cell POPCON technique allows consideration of a wide range of parameters in the relatively simple near-Maxwellian central cell, facilitating the selection of more optimal central cell plasmas. These advances make it possible to find more conservative classical tandem mirror fusion pilot plant operating points with lower temperatures, neutral beam energies and end plug performance requirements than designs in the literature. Despite being more conservative, it is shown that these operating points have sufficient confinement performance to serve as the basis of a viable fusion pilot plant provided that they can be stabilized against magnetohydrodynamic and trapped particle modes.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY

Precision Measurement of the Muon Spin Precession Frequency in the Fermilab Muon g-2 Experiment

The Fermilab Muon $g-2$ Experiment is designed to measure the muon's anomalous magnetic moment, $ a_\mu = (g-2)/2 $ with an accuracy of 140 parts per billion. This quantity is determined from two key measurements; the difference between the muon's spin precession frequency and its cyclotron frequency, given by $\omega_a = \omega_s - \omega_c$, and $\tilde{\omega_p^\prime}$, proportional to the muon-weighted magnetic field.In this talk, we focus on presenting the methodology for determining $\omega_a$. Muons with a momentum of 3.1 GeV are injected into a storage ring, and $\omega_a$ is extracted from the time distribution of decay positrons recorded by 24 electromagnetic calorimeters placed symmetrically inwards around the ring. We present the final result from the muon g-2 collaboration and analysis techniques based on data collected from 2020 to 2023.

Zaid, Estifa'a [Liverpool U.]

Ultralow-temperature cryogenic transmission electron microscopy using a new helium flow cryostat stage

Advances in cryogenic electron microscopy have opened new avenues for probing quantum phenomena in correlated materials. This study reports the installation and performance of a new side-entry condenZero cryogenic cooling system for JEOL (Scanning) Transmission Electron Microscopes (S/TEM), utilizing compressed liquid helium (LHe) and designed for imaging and spectroscopy at ultra-low temperatures. The system includes an external dewar mounted on a vibration-damping stage and a pressurized, low-noise helium transfer line with a remotely controllable needle valve, ensuring stable and efficient LHe flow with minimal thermal and mechanical noise. Performance evaluation demonstrates a stable base temperature of 4.37 K measured using a Cernox bare chip sensor on the holder with temperature fluctuations within ±0.004 K. Complementary in-situ electron energy-loss spectroscopy (EELS) via aluminum bulk plasmon analysis was used to measure the local specimen temperature and validate cryogenic operation during experiments. The integration of cryogenic cooling with other microscopy techniques, including electron diffraction and Lorentz TEM, was demonstrated by resolving charge density wave (CDW) transitions in NbSe2 using electron diffraction, and imaging nanometric magnetic skyrmions in MnSi via Lorentz TEM. In conclusion, this platform provides reliable cryogenic operation below 7 K, establishing a low-drift route for direct visualization of electronic and magnetic phase transformations in quantum materials.

Charge density wave

Porous transport electrodes for oxygen evolution reaction in proton exchange membrane water electrolysis -cells: Materials, designs, and diagnoses

H 2 production using proton exchange membrane (PEM) water electrolysis (PEMWE) cells has received considerable attention because of the high efficiencies of these cells and no harmful emissions from the related process. In PEMWE cells, porous transport electrodes (PTEs) composed of a catalyst layer (CL) comprising O 2 evolution reaction (OER) catalysts, porous transport layer (PTL), and PEM play key roles in the stack performance and lifetime. Herein, Ir-based and non-precious-metal OER catalysts that are highly active and stable at low pH values and high anodic potentials are reviewed to understand their OER mechanisms. Various strategies are proposed for engineering CLs and PTLs to improve the interfacial properties and mass transfers of reactants and products to and from the active sites. Additionally, diagnoses of PTEs is significantly crucial for interpreting electrochemical processes and addressing their current challenges. Therefore, half-cell analyses, including diffusion electrode (DE), floating electrode (FE), and modified rotating disk electrode (MRDE) techniques, are explored, and membrane electrode assembly (MEA)-based analyses, such as the polarization technique, electrochemical impedance spectroscopy, and magnetic field analysis, are established. In conclusion, this study aims to provide an overview of recent technologies used for the engineering and diagnostic tools of PEMWE cells and insights into the advanced components and systems to be developed in this field.

Diagnosis of PEMWE Cells

Reference Hardware and Software Architecture for a Solenoid Pulser for Scientific Instrumentation at the National Ignition Facility

High current, high voltage solenoid pulser power systems for the generation of magnetic fields in a solenoid is not a radical or new concept. Despite being a cornerstone of scientific and weapons research for over 100 years, a commercial off the shelf unit easily configurable for a broad set of applications has yet to appear on the open market. Pulser systems are instead designed for specific target requirements. For gigawatt to terawatt systems, this is unavoidable. For megawatt systems however, many hundreds of thousands of dollars are wasted designing pulser systems from the ground up for clients, when it is possible to simply architect a modular system once that can have its capacitors swapped for many possible target applications. The National Ignition Facility (NIF) at the Lawrence Livermore National Laboratory (LLNL) is one such institution that would benefit from such a system, having bought such pulsers for several imaging systems. Ideally, all such a system would require is only a bachelors-level circuit analysis to find the correct capacitor values, as well as a written procedure to calibrate the software to correctly deliver the voltages required by the application. In this work, systems architecture and software engineering techniques are used to design and analyze such a system. Such a design, it is the hope of this author, will be used in scientific and engineering purposes in the future to build solenoid pulsers at the National Ignition Facility and other institutions to drastically cut development costs of scientific instrumentation.

42 ENGINEERING