Search NASA⌕ Search

SEARCH · Search NASA

Results for “magnetic imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Magnetic imaging of topological phases of matter (Final Report)

This project presents a detailed understanding of the local electronic transport in two different types of conductors. The experimental tools are a combination of local magnetic probes and electronic transport measurements. The first set of samples were superconducting microstructures that exhibited unusual transport behavior. Magnetic imaging revealed the presence of a strain field in the microstructures, which spatially modulated the superconducting properties. This strain field can be controlled through a variety of design parameters opening opportunities for a broad range of quantum materials including topological phases of matter. The second set of samples was fabricated from Cr-doped (Bi,Sb) 2 Te 3 heterostructures that exhibited the quantum anomalous Hall effect (QAHE). Magnetic imaging visualized the current flow in these devices, while simultaneous transport measurements verified that the devices exhibit the QAHE. Surprisingly, the current flowed in the interior of the sample even when exhibiting a high level of quantization.

36 MATERIALS SCIENCE↗

Magnetic Imaging with Spin Defects in Hexagonal Boron Nitride

Optically active spin defects hosted in hexagonal boron nitride (ℎ-BN) are promising candidates for the development of a two-dimensional (2D) quantum sensing unit. Here, we demonstrate quantitative magnetic imaging with ℎ-BN flakes doped with negatively charged boron-vacancy ($V^{-}_{B}$) centers through neutron irradiation. As a proof-of-concept, we image the magnetic field produced by Cr⁢Te 2 , a van der Waals ferromagnet with a Curie temperature slightly above 300 K. Compared to other quantum sensors embedded in 3D materials, the advantages of the ℎ-BN-based magnetic sensor described in this work are its ease of use, high flexibility, and, more importantly, its ability to be placed in close proximity to a target sample. Further, such a sensing unit will likely find numerous applications in 2D materials research by offering a simple way to probe the physics of van der Waals heterostructures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Machine learning for improved current-density reconstruction from two-dimensional vector magnetic images

The reconstruction of electrical current densities from magnetic field measurements is an important technique with applications in materials science, circuit design, quality control, plasma physics, and biology. Analytic reconstruction methods exist for planar currents, but break down in the presence of high-spatial-frequency noise or large standoff distance, restricting the types of systems that can be studied. Here, we demonstrate the use of a deep convolutional neural network for current density reconstruction from two-dimensional images of vector magnetic fields acquired by a quantum diamond microscope . Trained network performance significantly exceeds analytic reconstruction for data with high noise or large standoff distances. This machine learning technique can perform quality inversions on lower-signal-to-noise-ratio data, significantly reducing the data collection time and permitting reconstructions of weaker and three-dimensional current sources. Published by the American Physical Society 2025

Reed, Niko R. (ORCID:0009000305222403)↗

Magnetic flux imaging in a 3D superconductor integrated circuit

We report on imaging magnetic flux distributions in a multilayered superconductor integrated circuit which emerge during magnetization and after field cooling of the circuit in the DC magnetic field. The obtained complicated field maps expose the flux propagation across the patterned superconducting ground planes sandwiching layers with Josephson junction-based logic cells, fine wire grid around the functional units, and multiple superconducting fill structures located in different inner layers. The observed intricate flux distributions are explained by specific patterns of Meissner screening currents and superconducting critical currents in different mutually interacting parts of the integrated circuit. Our results provide important insights into possible ways of improving the protection of superconductor integrated circuits from magnetic fields and their resilience against flux trapping.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Multihead Attention U‐Net for Magnetic Particle Imaging–Computed Tomography Image Segmentation

Magnetic particle imaging (MPI) is an emerging noninvasive molecular imaging modality with high sensitivity and specificity, exceptional linear quantitative ability, and potential for successful applications in clinical settings. Computed tomography (CT) is typically combined with the MPI image to obtain more anatomical information. Herein, a deep learning‐based approach for MPI‐CT image segmentation is presented. The dataset utilized in training the proposed deep learning model is obtained from a transgenic mouse model of breast cancer following administration of indocyanine green (ICG)‐conjugated superparamagnetic iron oxide nanoworms (NWs‐ICG) as the tracer. The NWs‐ICG particles progressively accumulate in tumors due to the enhanced permeability and retention (EPR) effect. The proposed deep learning model exploits the advantages of the multihead attention mechanism and the U‐Net model to perform segmentation on the MPI‐CT images, showing superb results. In addition, the model is characterized with a different number of attention heads to explore the optimal number for our custom MPI‐CT dataset.

Juhong, Aniwat↗

Imaging nanomagnetism and magnetic phase transitions in atomically thin CrSBr

Since their first observation in 2017, atomically thin van der Waals (vdW) magnets have attracted significant fundamental, and application-driven attention. However, their low ordering temperatures, T c , sensitivity to atmospheric conditions and difficulties in preparing clean large-area samples still present major limitations to further progress, especially amongst van der Waals magnetic semiconductors. The remarkably stable, high-T c vdW magnet CrSBr has the potential to overcome these key shortcomings, but its nanoscale properties and rich magnetic phase diagram remain poorly understood. Here we use single spin magnetometry to quantitatively characterise saturation magnetization, magnetic anisotropy constants, and magnetic phase transitions in few-layer CrSBr by direct magnetic imaging. We show pristine magnetic phases, devoid of defects on micron length-scales, and demonstrate remarkable air-stability down the monolayer limit. We furthermore address the spin-flip transition in bilayer CrSBr by imaging the phase-coexistence of regions of antiferromagnetically (AFM) ordered and fully aligned spins. Our work will enable the engineering of exotic electronic and magnetic phases in CrSBr and the realization of novel nanomagnetic devices based on this highly promising vdW magnet.

36 MATERIALS SCIENCE↗

Roadmap on nanoscale magnetic resonance imaging

Abstract The field of nanoscale magnetic resonance imaging (NanoMRI) was started 30 years ago. It was motivated by the desire to image single molecules and molecular assemblies, such as proteins and virus particles, with near-atomic spatial resolution and on a length scale of 100 nm. Over the years, the NanoMRI field has also expanded to include the goal of useful high-resolution nuclear magnetic resonance (NMR) spectroscopy of molecules under ambient conditions, including samples up to the micron-scale. The realization of these goals requires the development of spin detection techniques that are many orders of magnitude more sensitive than conventional NMR and MRI, capable of detecting and controlling nanoscale ensembles of spins. Over the years, a number of different technical approaches to NanoMRI have emerged, each possessing a distinct set of capabilities for basic and applied areas of science. The goal of this roadmap article is to report the current state of the art in NanoMRI technologies, outline the areas where they are poised to have impact, identify the challenges that lie ahead, and propose methods to meet these challenges. This roadmap also shows how developments in NanoMRI techniques can lead to breakthroughs in emerging quantum science and technology applications.

Budakian, Raffi↗

Wide-field microwave magnetic field imaging with nitrogen-vacancy centers in diamond

Non-invasive imaging of microwave (MW) magnetic fields with microscale lateral resolution is pivotal for various applications, such as MW technologies and integrated circuit failure analysis. Diamond nitrogen-vacancy (NV) center magnetometry has emerged as an ideal tool, offering micrometer-scale resolution, millimeter-scale field of view, high sensitivity, and non-invasive imaging compatible with diverse samples. However, up until now, it has been predominantly used for imaging of static or low-frequency magnetic fields or, concerning MW field imaging, to directly characterize the same microwave device used to drive the NV spin transitions. In this work, we leverage an NV center ensemble in diamond for wide-field imaging of MW magnetic fields generated by a test device employing a differential measurement protocol. The microscope is equipped with a MW loop to induce Rabi oscillations between NV spin states, and the MW field from the device-under-test is measured through local deviations in the Rabi frequency. This differential protocol yields magnetic field maps of a 2.57 GHz MW field with a sensitivity of ∼9 μT Hz −1/2 for a total measurement duration of T=357 s, covering a 340 × 340 μm 2 field of view with a micrometer-scale spatial resolution and a device-under-test input power dynamic range of 30 dB. This work demonstrates a novel NV magnetometry protocol, based on differential Rabi frequency measurement, that extends NV wide-field imaging capabilities to imaging of weak MW magnetic fields that would be difficult to measure directly through standard NV Rabi magnetometry.

crystallographic defects↗

Precipitation of gadolinium from magnetic resonance imaging contrast agents may be the Brass tacks of toxicity

The formation of gadolinium-rich nanoparticles in multiple tissues from intravenous magnetic resonance imaging contrast agents may be the initial step in rare earth metallosis. The mechanism of gadolinium-induced diseases is poorly understood, as is how these characteristic nanoparticles are formed. Gadolinium deposition has been observed with all magnetic resonance imaging contrast agent brands. Aside from endogenous metals and acidic conditions, little attention has been paid to the role of the biological milieu in the degradation of magnetic resonance imaging contrast agents into nanoparticles. Herein, we describe the decomposition of the commercial magnetic resonance imaging contrast agents Omniscan and Dotarem in the presence of oxalic acid, a well-known endogenous compound. Omniscan dechelated rapidly and preluded measurement by the means available, while Dotarem underwent a two-step decomposition process. The decomposition of both magnetic resonance imaging contrast agents by oxalic acid formed gadolinium oxalate (Gd 2 [C 2 O 4 ] 3 , Gd 2 Ox 3 ). Furthermore, both observed steps of the Dotarem reaction involved the associative addition of oxalic acid. Adding protein (bovine serum albumin) increased the rate of dechelation. Displacement reactions could occur at lysosomal pH. Through these studies, we have demonstrated that magnetic resonance imaging contrast agents can be dissociated by endogenous molecules, thus illustrating a metric by which gadolinium-based contrast agents (GBCAs) might be destabilized in vivo.

Gadodiamide↗

The onset of rare earth metallosis begins with renal gadolinium-rich nanoparticles from magnetic resonance imaging contrast agent exposure

The leitmotifs of magnetic resonance imaging (MRI) contrast agent-induced complications range from acute kidney injury, symptoms associated with gadolinium exposure (SAGE)/gadolinium deposition disease, potentially fatal gadolinium encephalopathy, and irreversible systemic fibrosis. Gadolinium is the active ingredient of these contrast agents, a non-physiologic lanthanide metal. The mechanisms of MRI contrast agent-induced diseases are unknown. Mice were treated with a MRI contrast agent. Human kidney tissues from contrast-naïve and MRI contrast agent-treated patients were obtained and analyzed. Kidneys (human and mouse) were assessed with transmission electron microscopy and scanning transmission electron microscopy with X-ray energy-dispersive spectroscopy. MRI contrast agent treatment resulted in unilamellar vesicles and mitochondriopathy in renal epithelium. Electron-dense intracellular precipitates and the outer rim of lipid droplets were rich in gadolinium and phosphorus. We conclude that MRI contrast agents are not physiologically inert. The long-term safety of these synthetic metal–ligand complexes, especially with repeated use, should be studied further.

36 MATERIALS SCIENCE↗

Imaging the magnetic nanowire cross section and magnetic ordering within a suspended 3D artificial spin-ice

Artificial spin-ice systems are patterned arrays of magnetic nanoislands arranged into frustrated geometries and provide insight into the physics of ordering and emergence. The majority of these systems have been realized in two-dimensions, mainly due to the ease of fabrication, but with recent developments in advanced nanolithography, three-dimensional artificial spin ice (ASI) structures have become possible, providing a new paradigm in their study. Such artificially engineered 3D systems provide new opportunities in realizing tunable ground states, new domain wall topologies, monopole propagation, and advanced device concepts, such as magnetic racetrack memory. Direct imaging of 3DASI structures with magnetic force microscopy has thus far been key to probing the physics of these systems but is limited in both the depth of measurement and resolution, ultimately restricting measurement to the uppermost layers of the system. In this work, a method is developed to fabricate 3DASI lattices over an aperture using two-photon lithography, thermal evaporation, and oxygen plasma exposure, allowing the probe of element-specific structural and magnetic information using soft x-ray microscopy with x-ray magnetic circular dichroism (XMCD) as magnetic contrast. The suspended polymer–permalloy lattices are found to be stable under repeated soft x-ray exposure. Analysis of the x-ray absorption signal allows the complex cross section of the magnetic nanowires to be reconstructed and demonstrates a crescent-shaped geometry. Measurement of the XMCD images after the application of an in-plane field suggests a decrease in magnetic moment on the lattice surface due to oxidation, while a measurable signal is retained on sub-lattices below the surface.

36 MATERIALS SCIENCE↗

A Field-Deployable Magnetic Resonance Imaging Rhizotron for Modeling and Enhancing Root Growth and Biogeochemical Function

A collaborative team from Texas A&M AgriLife Research, ABQMR Inc., the Soil Health Institute, the Athinoula A. Martinos Center for Biomedical Imaging, and NIST developed low-field magnetic resonance imaging (LF-MRI) instrumentation capable of imaging intact soil-root systems. The system measured root biomass, architecture, 3D mass distribution, and growth rates, providing a non-destructive means to evaluate ideal plant characteristics based on root metrics. It also successfully generated three-dimensional images of soil water content, a key property influencing root growth and exploration. Operating much like an MRI used in a medical setting, the system functioned in field conditions without damaging plants, overcoming the limitations of traditional methods such as trenching, soil coring, and root excavation. Over the course of the project, the team designed and built three functional prototype systems. These prototypes provided new insights into root–water–soil interactions that drive processes such as nutrient uptake, water use, and carbon management. This information contributed to efforts to optimize plants for carbon sequestration without sacrificing economic yield. The project also supported the identification of desirable traits for energy sorghum, including high root growth rates, more vertical root angles, and enhanced drought resilience under water-limiting conditions.

09 BIOMASS FUELS↗

Reducing the Energy Consumption of Magnetic Resonance Imaging and Computed Tomography Scanners: Integrating Ecodesign and Sustainable Operations

This review aims to provide valuable insights into how energy consumption in magnetic resonance imaging (MRI) and computed tomography (CT) scanners can be effectively monitored, managed, and reduced, thereby contributing to more sustainable medical imaging practices. Demand for advanced imaging technologies such as MRI and CT scanners continues to increase, and understanding the resultant impact on greenhouse gas emissions requires a thorough evaluation of their energy consumption. Here, this review examines the energy monitoring and consumption characteristics of MRI and CT scanners, highlighting potential approaches for energy savings. An overview of MRI and CT principles, hardware components, and their associated energy consumption is provided. After addressing the technical aspects, the hardware and software requirements essential for accurate energy metering are detailed. Baseline measurements of energy consumption data are then provided as a foundation to understand current usage patterns and identify areas for improvement. Ongoing efforts to reduce energy consumption are categorized into 3 main strategies: operations, scanner design enhancements, and active scanning techniques, including accelerated MRI protocols. Ultimately, we emphasize that achieving sustainability in medical imaging requires collaboration across disciplines. By incorporating eco-friendly design in new imaging equipment, we can reduce the environmental impact, promote sustainability, and set a health care industry standard for a healthier planet.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

The safety of magnetic resonance imaging contrast agents

Gadolinium-based contrast agents are increasingly used in clinical practice. While these pharmaceuticals are verified causal agents in nephrogenic systemic fibrosis, there is a growing body of literature supporting their role as causal agents in symptoms associated with gadolinium exposure after intravenous use and encephalopathy following intrathecal administration. Gadolinium-based contrast agents are multidentate organic ligands that strongly bind the metal ion to reduce the toxicity of the metal. The notion that cationic gadolinium dissociates from these chelates and causes the disease is prevalent among patients and providers. We hypothesize that non-ligand-bound (soluble) gadolinium will be exceedingly low in patients. Soluble, ionic gadolinium is not likely to be the initial step in mediating any disease. The Kidney Institute of New Mexico was the first to identify gadolinium-rich nanoparticles in skin and kidney tissues from magnetic resonance imaging contrast agents in rodents. In 2023, they found similar nanoparticles in the kidney cells of humans with normal renal function, likely from contrast agents. We suspect these nanoparticles are the mediators of chronic toxicity from magnetic resonance imaging contrast agents. This article explores associations between gadolinium contrast and adverse health outcomes supported by clinical reports and rodent models.

59 BASIC BIOLOGICAL SCIENCES↗

High fidelity simulations of contaminant dispersion in an urban environment with comparison to magnetic resonance imaging measurements

The dispersion of a contaminant in an urban environment has the potential to impact a large population of people. In this work, a complex urban canopy flow based on the Oklahoma City downtown business district circa 2003 is studied using Magnetic Resonance Imaging (MRI) and high-fidelity Large Eddy Simulations (LES). MRI is a novel experimental technique that can provide high-resolution measurements in four dimensions (three spatial and temporal) for lab scale models. The experiments and simulations use the same geometry and boundary conditions providing a one-to-one comparison of the two methods. Results are presented on the time-averaged velocity and concentration fields, the temporal dynamics of the concentration plumes for a transient release, and a novel Cloud Identification Algorithm that can separate plumes produced by periodic contaminant releases used for ensemble averaging over many releases. The MRI and LES datasets both include millions of measurement voxels and the comparisons highlight the complex 3D nature of the flow including strong vertical velocities in spanwise street canyons and flow acceleration in streamwise street canyons. The concentration fields are qualitatively similar albeit the LES shows larger dispersion. A quantitative analysis with performance measures compares the datasets pointwise and demonstrates that the two 3D datasets are similar with respect to many measures including a fractional bias of 0.02 (ideal=0.0), correlation coefficient of 0.87 (ideal = 1.0), and the fraction points within a factor of 2 is 0.98 (ideal = 1.0). Plume analysis compares the arrival and residence time of contaminant and is found to vary significantly with location within the urban environment with arrival times between 0 and 1.25 and differences within the contaminant cloud less than 10% at most locations.

54 ENVIRONMENTAL SCIENCES↗

A Telomerase-Activated Magnetic Resonance Imaging Probe for Consecutively Monitoring Tumor Growth Kinetics and In Situ Screening Inhibitors

Telomerase has long been considered as a biomarker for cancer diagnosis and a therapeutic target for drug discovery. Detecting telomerase activity in vivo could provide more direct information of tumor progression and response to drug treatment, which, however, is hampered by the lack of an effective probe that can generate an output signal without a tissue penetration depth limit. Here in this study, using the principle of distance-dependent magnetic resonance tuning, we constructed a telomerase-activated magnetic resonance imaging probe (TAMP) by connecting superparamagnetic ferroferric oxide nanoparticles (SPFONs) and paramagnetic Gd-DOTA (Gd(III) 1,4,7,10- tetraazacyclododecane-1,4,7,10-tetraazacyclododecane-1,4,7,10-tet-raacetic acid) complexes via telomerase-responsive DNA motifs. Upon telomerase-catalyzed extension of the primer in TAMP, Gd-DOTA-conjugated oligonucleotides can be liberated from the surface of SPFONs through a DNA strand displacement reaction, restoring the T 1 signal of the Gd-DOTA for a direct readout of the telomerase activity. Here we show that, by tracking telomerase activity, this probe provides consistent monitoring of tumor growth kinetics during progression and in response to drug treatment and enables in situ screening of telomerase inhibitors in whole-animal models. This study provides an alternative toolkit for cancer diagnosis, treatment response assessment, and anticancer drug screening.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗