Search NASA⌕ Search

SEARCH · Search NASA

Results for “masers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Interacting masers and the extreme brightness of astrophysical water masers

Extreme surface brightnesses have long been reported for water masers which are well beyond what is found in self-consistent, theoretical investigations of these masers. The transport of maser radiation is calculated when two masers, having the properties inferred for the numerous weaker masers and separated by distances characteristic of the molecular cloud, are aligned to within the angular spread of the beam of maser radiation. The beam size is reduced and brightness temperatures similar to the highest observed values are readily produced. This enhanced beaming reduces the number of photons required from each maser feature to a level that can be understood within available pumping scenarios. The large number of weaker masers that have been identified in the most luminous galactic cloud of water masers (the W49 region) makes it especially plausible that alignments occur and produce the very bright masers in this region.

Deguchi, Shuji↗

Detection of a weak maser emission pedestal associated with the SiO maser

Results are reported for high-spectral-resolution observations of the v = 1, J = 1-0 SiO maser sources at 43,122.027 MHz (6.95 mm wavelength) associated with the variable stars Omega Cet, NML Tau, VY CMa, R Leo, W Hya, VX Sgr, NML Cyg, and R Cas. A weak underlying maser emission pedestal is clearly observed in the spectra of all but NML Cyg and R Cas. The data indicate that the underlying pedestal of SiO emission appears to originate in a shell-like region around the star, has a thermal appearance even though it must be due to weak maser emission, and appears to be part of the spectral signature of SiO maser emission from late-type stars. It is found that the center velocities of the pedestals may be used to determine stellar radial velocities. Observations of large-scale time variations in the intensity of the Ori A SiO maser and the detection of weak maser pedestals associated with each of the two strong emission-feature groups in Orion are also discussed. It is suggested that the Orion molecular cloud might contain two late-type long-period variable stars that may be semiregular variables.

Snyder, L. E.↗

Saturation and beaming in astrophysical masers. III - Asymmetrically pumped masers

There is reason to believe that the physical conditions in many astrophysical masers are far from homogeneous. In particular, if the maser pump involves the absorption of infrared photons, the pump rate may vary rapidly (perhaps exponentially) across the cloud. The consequences of such variation of the pump rate for the maser radiation are calculated, and it is shown that there are substantial asymmetries in the output of the maser. A general result is that the maser radiation is preferentially emitted back toward the source of pump radiation. The implication of this result for the interpretation of the circumstellar 1612 MHz OH masers is briefly discussed.

Alcock, C.↗

Theoretical comparison of maser materials for a 32-GHz maser amplifier

The computational results of a comparison of maser materials for a 32 GHz maser amplifier are presented. The search for a better maser material is prompted by the relatively large amount of pump power required to sustain a population inversion in ruby at frequencies on the order of 30 GHz and above. The general requirements of a maser material and the specific problems with ruby are outlined. The spin Hamiltonian is used to calculate energy levels and transition probabilities for ruby and twelve other materials. A table is compiled of several attractive operating points for each of the materials analyzed. All the materials analyzed possess operating points that could be superior to ruby. To complete the evaluation of the materials, measurements of inversion ratio and pump power requirements must be made in the future.

Lyons, James R.↗

Radiative transfer in astronomical masers. III - Filamentary masers

The complete solution of a filamentary maser is presented. An integral equation and an iterative procedure are developed to calculate and solve the contribution of rays emanating from the filament sidewall. The solution provides complete expressions for the distributions of intensity and flux across the source as functions of position and direction with regard to the axis. The results are used to find the number distribution of brightness temperature in a large sample of randomly oriented filaments with an arbitrary distribution of lengths. The effects of external radiation on the maser structure and intensity are studied. It is proposed that the two giant bursts of H2O maser emission observed in W49 and Orion resulted from the interaction or two interacting filaments and a foreground slab amplifying a background filament.

Elitzur, Moshe↗

Atomic hydrogen for low temperature atomic hydrogen masers and in-vacuum dissociators for VLG-11 series masers

The operation of a cryogenically-cooled hydrogen maser using an RF plasma dissociator operating at liquid nitrogen temperature (77K) in confunction with a state selector magnet whose dimensions are suitable for slow atoms is studied. The focusing characteristics for a hexapole state selector magnet with maximum fields at the pole tips, provide a maximum acceptance angle for atoms at the most probable velocity in the beam. By thermally isolating the RF circuitry from the dissociator glassware, only dielectric losses in the glass and the energy coupled to the plasma will result in the boil-off of liquid nitrogen. It is estimated that this is about one watt and thus a loss rate of approximately .022 liters pr hour is anticipated.

Vessot, R. F. C.↗

Astrophysical masers; Proceedings of the Conference, Arlington, VA, Mar. 9-11, 1992

Various papers on astrophysical masers are presented. The general topics addressed include: theory, maser surveys, extragalactic masers, masers in star-forming regions (general), OH masers in star-forming regions, water masers in star-forming regions, methanol masers in star-forming regions, proper motions, scattering, variability, circumstellar masers (general), circumstellar OH masers, circumstellar water masers, circumstellar SiO masers, and solar system masers.

Clegg, Andrew W.↗

The Physical Parameters of Clumps Associated with Class I Methanol Masers

We present a study of the association between class I methanol masers and cold dust clumps from the APEX Telescope Large Area Survey of the Galaxy (ATLASGAL) survey. It was found that almost 100% of class I methanol masers are associated with objects listed in the ATLASGAL compact source catalog. We find a statistically significant difference in the flux density, luminosity, number and column density, and temperature distributions of ATLASGAL sources associated with 95/44 GHz methanol masers compared with those ATLASGAL sources devoid of 95 GHz methanol masers. The masers tend to arise in clumps with higher densities, luminosities, and temperatures compared with both the full sample of ATLASGAL clumps, as well as the sample of ATLASGAL sources that were cross-matched with positions previously searched for methanol masers but with no detections. Comparison between the peak position of ATLASGAL clumps and the interferometric positions of the associated class I and II methanol masers reveals that class I masers are generally located at larger physical distances from the peak submillimeter emission than class II masers. We conclude that the tight association between ATLASGAL sources and class I methanol masers may be used as a link toward understanding the conditions of the pumping of these masers and evolutionary stages at which they appear.

79 ASTRONOMY AND ASTROPHYSICS↗

Complete the development and construction of a spaceborne hydrogen maser clock

The objective, to complete the development of an engineering model of a spaceborne hydrogen maser, was successfully achieved. A layout of the maser and detail drawings of the physics package was completed during the first 7 months of the contract. A computer model was made for the maser's thermal design. Using numerical computations, heater resistances were established for 7 temperature controlled zones. The physics package includes: a vacuum manifold that houses four sorption pumps capable of scavenging hydrogen for 4 years, a titanium vacuum tank housing the cavity, metallic seals for all vacuum joints, an RF dissociator within the vacuum envelope, a two-layer printed circuit solenoid and four layers of moly-permalloy magnetic shields. Problems were encountered and overcome in the procurements of the PC solenoid and the magnetic shields. After completion of the fabrication of the maser's components, the maser was assembled using these parts and other components made available by SAO, NRL, and NASA from earlier development work. In March, 1990, the vacuum system was assembled, and by May the maser assembly was completed. The magnetic shielding was poor and the shields were removed, reannealed by a local vendor, and the maser was reassembled. The maser began tests in early June and has been oscillating since that time. The test results of the maser are very good and a life test of the maser is being conducted. It is anticipated that the development and construction of a maser to be tested in space under a new contract from NASA's Marshall Space Flight Center will continue.

Vessot, Robert F. C.↗

Discovery of 22 GHz Water Masers in the Serpens South Region

Using the Karl G. Jansky Very Large Array (VLA), we have conducted a survey for 22 GHz, 6{sub 1,6}–5{sub 2,3} H{sub 2}O masers toward the Serpens South region. The masers were also observed with the Very Long Baseline Array following the VLA detections. We detect for the first time H{sub 2}O masers in the Serpens South region that are found to be associated to three Class 0–Class I objects, including the two brightest protostars in the Serpens South cluster, known as CARMA-6 and CARMA-7. We also detect H{sub 2}O masers associated to a source with no outflow or jet features. We suggest that this source is most probably a background asymptotic giant branch star projected in the direction of Serpens South. The spatial distribution of the emission spots suggest that the masers in the three Class 0–Class I objects emerge very close to the protostars and are likely excited in shocks driven by the interaction between a protostellar jet and the circumstellar material. Based on the comparison of the distributions of bolometric luminosity of sources hosting 22 GHz H{sub 2}O masers and 162 young stellar objects covered by our observations, we identify a limit of L {sub Bol} ≈ 10L {sub ⊙} for a source to host water masers. However, the maser emission shows strong variability in both intensity and velocity spread, and therefore masers associated to lower-luminosity sources may have been missed by our observations. We also report 11 new sources with radio continuum emission at 22 GHz.

47 OTHER INSTRUMENTATION↗

A receiver design for the superconducting cavity-maser oscillator

A new frequency standard was demonstrated with the aid of a double phase locked loop (PLL) receiver. A superconducting cavity maser oscillator (SCMO) and a hydrogen maser are combined to show the medium term performance of the hydrogen maser together with improved short term performance made possible by the SCMO. The receiver, which generates a 100 MHz signal with reduced noise, is phase locked to (and may be used in place of) the 100 MHz hydrogen maser output. The maser signal, 2.69xxx-GHz SCMO output, and a 100 MHz quartz crystal oscillator are optimally combined by the receiver. A measured two source fractional frequency stability of 2 x 10(exp -14) was obtained for a measuring time of r = 1 sec, and 1 x 10(exp -15) at r = 1,000 sec. The 1 sec value is approx. 10 times lower than that for hydrogen masers, while the 1,000 sec value is identical to hydrogen maser performance. The design is based on phase noise models for the hydrogen maser, the SCMO, and quartz crystal oscillators for offset frequencies down to 1 x 10(exp -6) Hz.

Wang, R. T.↗

A correlational analysis of the effects of changing environmental conditions on the NR atomic hydrogen maser

An extensive statistical analysis has been undertaken to determine if a correlation exists between changes in an NR atomic hydrogen muser's frequency offset and changes in environmental conditions. Data have been acquired over the past 20 months by recording the frequency offset of three NR atomic hydrogen masers along with the relative and absolute humidity, barometric pressure, and ambient temperature of the laboratory in which the masers are maintained. Correlational analyses have been performed comparing barometric pressure, humidity, and temperature with maser frequency offset as functions of time for periods ranging from 5.5 to 17 days. Semi partial correlation coefficients as large as -0.9 have been fond between barometric pressure and maser frequency offset for data covering periods as long as a week. Maser frequency offset and barometric pressure were consistently found to change simultaneously. The correlation between humidity and frequency offset is less predictable, and the resulting semi partial correlation coefficients were usually small when compared with those derived from the relationship between pressure and frequency offset. The time delay between changes in humidity and correlated changes in maser frequency offset was found to vary extensively with no predictable pattern. Analysis of temperature data indicates that, in the most current design, temperature does not significant(y affect maser frequency offset in the laboratory environment. Thus, the results of the analyses disclose a significant statistical correlation between changes in maser frequency offset and changes in barometric pressure. The statistics also reveal some correlation between humidity and frequency offset, bat for reasons to be discussed, the effects of humidity should be considered secondary to the effects of changing barometric pressure.

R. A. Dragonette↗

A search for H2O masers in 100 active dwarf galaxies

ABSTRACT We present the results of the first dedicated survey for 22 GHz H2O maser emission in dwarf galaxies outside of the Local Group, with the aim of discovering disc masers. Studies of disc masers yield accurate and precise measurements of black hole (BH) mass, and such measurements in dwarf galaxies would be key to understanding the low-mass end of BH–galaxy coevolution. We used the Green Bank Telescope to survey 100 nearby (z ≲ 0.055) dwarf galaxies (M* ≲ 109.5 M⊙) with optical emission line ratios indicative of accretion on to a massive black hole. We detected no new masers down to a limit of ∼12 mJy (5σ). We compared the properties of our sample with those of ∼1850 known detections and non-detections in massive galaxies. We find, in agreement with previous studies, that masers are preferentially hosted by Seyferts and highly obscured, [O iii]-bright active galactic nuclei (AGNs). Our sample has fewer Seyferts, is less obscured, and is [O iii]-faint. Though the overall maser detection rate is ∼3 per cent in massive galaxies, the predicted rate for our sample, weighted by its optical properties, is ∼0.6–1.7 per cent, corresponding to a probability of making no detections of ∼20–50 per cent. We also found a slight increase in the detection rate with increased stellar mass in previously surveyed galaxies. However, further observations are required to discern whether there is an intrinsic difference between the maser fraction in active dwarf galaxies and in their massive counterparts for the same AGN properties.

Rosenthal, M. J.↗

Characteristics of advanced hydrogen maser frequency standards

In house research and development at Goddard Space Flight Center to provide advanced frequency and time standards for the most demanding applications is concentrated primarily in field operable atomic hydrogen masers. Some of the most important goals for the new maser designs have been improved long and short term stability, elimination of the need for auto tuning, increased maser oscillation level, improved hydrogen economy, increased operational life, minimization of operator control or monitoring, improvement in magnetic isolation or sensitivity, and reduction in size and weight. New design concepts which have been incorporated in these masers to achieve these goals are described. The basic maser assemblies and control systems have recently been completed; the masers are oscillating; and operational testing has begun. Data illustrating the improvements in maser performance was available and presented.

Peters, H. E.↗

X- and K-band maser development: Effects of interfering signals

Signals at levels exceeding - 90 dbmW at the input connection of a traveling-wave maser can affect maser performance in a variety of ways. Both S band and X band masers are considered where interfering signals are: (1) within the maser bandpass, (2) near the maser bandpass, and (3) far from the maser bandpass, where mixing with the maser pump can occur.

Clauss, R. C.↗