Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass accuracy”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Selective Detection of Diglycolamide Diastereomers By Metal-Ligand Cluster Formation

Introduction (120 words): Differentiation of isomers using mass spectrometry is a challenge, as these species tend to produce ions of identical mass-to-charge ratio. Therefore, separation with mass spectrometry must rely on chemical differences between isomeric species. Separation of stereoisomers is especially challenging, as these species often have very similar chemistry. However, recent investigations of the solvent extraction behavior of diastereomers of diglycolamide molecules have shown that different stereoisomers can have significantly different lanthanide extraction efficiencies. These studies showed that the R,S stereoisomer of 2,2'-oxybis(N,N-dioctylpropanamide efficiently extracts lanthanides, while the S,S stereoisomer does not. Thus, gas-phase metal complexation may provide a pathway for differentiating these species using mass spectrometry. Methods (120 words): Europium, samarium, and holmium clusters with the R,S, and the S,S diastereomers of 2,2'-oxybis(N,N-didecylpropanamide (trivially tetradecyl diglycolamide, or mTDDGA) were generated in gas-phase using the electrospray ionization source of a Bruker (Billerica, MA, USA) micrOTOF-Q II quadrupole time-of-flight mass spectrometer. Solutions of aqueous lanthanide nitrate and diglycolamide ligands in 2-propanol were added to 50%:50% by volume acetonitrile:2-propanol to generate the spray solutions. Ligand concentration was maintained at approximately 6 µM, while lanthanide concentration was maintained at either 6 µM or 30 µM . High resolution, high mass accuracy spectra were recorded using the time-of-flight. Mass accuracy was ensured using external calibration with Agilent (Santa Clara, CA, USA) ESI-L Low Concentration tuning mix. Preliminary data (300 words): Electrospray of solutions containing only R,S-mTDDGA or S,S-m-TDDGA yield abundant peaks at m/z= 721.7, corresponding to [mTDDGA+H]+1, m/z = 743.7, corresponding to [mTDDGA+Na]+1, and m/z = 1464.4, corresponding to the sodium-bound dimer, [Na(mTDDGA)2]+1. Spray of solutions containing 6 µM europium (Eu) with 3 µM R,S-mTDDGA produced an abundant cluster ion with an isotopic envelope centered at m/z=772.0, corresponding to [Eu(R,S-mTDDGA)3]3+. Europium-containing cluster ions with isotopic envelopes apexing at m/z = 1012.3 and 1189.0 correspond to the [Eu(R,S-mTDDGA)4]3+ and [Eu(R,S-mTDDGA)5]3+ cluster ions, respectively. Protonated and sodiated R,S-mTDDGA are present as well, along with the sodium-bound dimer. In contrast, spray of solutions containing 6 µM europium (Eu) with 3 µM S,S-mTDDGA diastereomer yielded only protonated and sodiated ligand ions; no Eu- S,S-mTDDGA ions were present. This mirrors the solution-phase behavior, where the S,S diestereomer extracts lanthanides with significantly less efficiency than the R,S diestereomer. Experiments with holmium and samarium yielded the same results. Increasing the lanthanide concentration to 30 µM resulted in limited formation of lanthanide-S,S-mTDDGA clusters. However, the abundance of the [Ln(S,S-mTDDGA)3]3+ clusters remained low compared to the abundance of the protonated and sodiated ligand. Additionally, the abundance of the [Ln(R,S-mTDDGA)3]3+ cluster ion was significantly higher than that of the protonated and sodiated ligand in experiments with spray solutions containing 30 µM lanthanide with R,S-mTDDA, supporting the hypothesis that R,S-mTDDGA has a higher intrinsic affinity for the lanthanides than S,S-mTDDGA. Thus, the intrinsic complexation with lanthanides appears to offer a route to differentiate diglycolamide diestereomers in the gas-phase. Novelty (20): Stereoisomers can be differentiated in the gas phase by exploitation of differences in metal complexation chemistry.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Preliminary Evidence of Gas-Phase Water Splitting on Holmium Nitrogen Oxide Clusters

Preliminary Evidence of Gas-Phase Water Splitting on Holmium Nitrogen Oxide Clusters Christopher A. Zarzana1, Makayla R. Baxter , Introduction: Molecular hydrogen is a potential energy carrier that could be used to help implement a clean energy economy if it is generated from splitting of water. Improvements in the efficiencies of water-splitting electrolyzers relies on development of novel materials with enhanced performance. However, research in this area is slowed due to underdeveloped understanding of the mechanisms of device performance due to challenges interrogating the fundamental chemical reactions at play in bulk materials. Studies of the intrinsic reactivity of clusters that are representative of the reactive sites of these materials can increase understanding of the fundamental reaction mechanisms involved in hydrogen production, allowing for more efficient development of new water-splitting materials. Methods: Holmium tetranitrato ([Ho(NO3)4]-) clusters were generated in gas-phase using the electrospray ionization source of a Bruker (Billerica, MA, USA) micrOTOF-Q II quadrupole time-of-flight mass spectrometer. Spray solutions consisted of aqueous holmium (Ho) nitrate solutions (at nominally 3 mM) diluted to 30 µM in acetonitrile. The holmium (Ho) tetranitrato clusters were isolated using the quadrupole and were subsequently activated and allowed to react with background water in the collision cell. High resolution, high mass accuracy spectra were recorded using the time-of-flight. Mass accuracy was ensured using external calibration with Agilent (Santa Clara, CA, USA) ESI-L Low Concentration tuning mix. Preliminary data: Collisional activation of the holmium tetranitrato complexes ([Ln(NO3)4]-) resulted in an expected series of ions resulting from the loss of ·NO and ·NO2. This included an ion at m/z = 382.885 assigned as [HoO2(NO3)3]- (theoretical m/z=382.884, error=-1.2 ppm), resulting from loss of ·NO, and an ion at m/z=366.890 assigned as [HoO(NO3)3]- (theorical m/z=366.889, error=-1.8 ppm), resulting from loss of ·NO2. Additional ions were detected that would result from more complicated losses from [Ho(NO3)4]-, including ions at m/z=320.898 assigned as [HoO2(NO3)2]- (theoretical m/z=320.896, error=-4.9 ppm), at m/z=304.904 assigned as [HoO(NO3)2]- (theoretical m/z=304.901, error=-8.1 ppm, very low signal), and at m/z=288.908 assigned as [Ho(NO3)2]- (theoretical m/z=288.907, error=-3.4 ppm). This ion series would arise from loss of some combination of ·NO, ·NO2, and ·NO3, although it is not known whether these losses occur sequentially (e.g. loss of ·NO and ·NO3 to yield [HoO2(NO3)2]-) or as a single species (e.g. direct loss of N2O4). These ions were accompanied by a complementary series representing addition of a single water molecule. This included an ion at m/z=338.908 assigned as [HoO2(NO3)2H2O]- (theoretical m/z=338.907, error=-4.1 ppm), an ion at m/z=322.912 assigned as [HoO(NO3)2H2O]- (theoretical m/z=322.912, error=1.2 ppm), and an ion at m/z=306.918 assigned as [Ho(NO3)2H2O]-, (theoretical m/z=306.918, error=-3.7 ppm). An additional hydrated ion was observed at m/z=276.921 assigned as [HoO2(NO3) H2O]- (theoretical m/z=276.919, error=-7.3 ppm), although corresponding dehydrated ion was not observed. An additional ion was observed at m/z=367.898 that has been assigned as [Ho(NO3)3OH]- (theoretical m/z=367.897, error=-2.5 ppm). It is hypothesized that this ion arises from addition of water to [Ho(NO3)3]- followed by elimination of a hydrogen radical. Neither [Ho(NO3)3]- nor [Ho(NO3)3H2O]- were detected, suggesting that, if the hypothesis is correct, addition of water to [Ho(NO3)3]- and its subsequent splitting is rapid. Elimination of HNO3 from [Ho(NO3)4H2O]- could also yield [Ho(NO3)3OH]-; however, no [Ho(NO3)4H2O]- ions were observed. Novelty: Potential evidence of water splitting on gas-phase lanthanide clusters offers a way to study the intrinsic reactivity of hydrogen-generation materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

ToF-SIMS spectral analysis of Shewanella oneidensis MR-1 biofilms

Analysis of bacterial biofilms is particularly challenging and important with diverse applications from systems biology to biotechnology. Among the variety of techniques that have been applied, time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many powerful features in studying the surface characteristics of biofilms. ToF-SIMS offers high spatial resolution, mass resolution, and mass accuracy, which permit surface sensitive analysis of biofilm components. Thus, ToF-SIMS provides a powerful solution to addressing the challenge of bacterial biofilm analysis. This dataset covers ToF-SIMS analysis of Shewanella oneidensis MR-1 isolated from freshwater lake sediment in New York state. The MR-1 strain is known to have metal and sulfur reducing properties and it can be used for bioremediation and wastewater treatment. There is a current need to identify small molecules and fragments produced from bacterial biofilms, especially those from extracellular polymeric substance (EPS). Static ToF-SIMS spectra of MR-1 were obtained using an IONTOF TOF.SIMS V instrument equipped with a 25 keV Bi$^+_3$ metal ion gun. Identified molecules and molecular fragments are compared against known biological databases and the reported peaks have at least 65 ppm mass accuracy. These molecules range from lipids, fatty acids, flavonoids, and quinolones to other naturally occurring organic compounds. It is anticipated that the mass spectral identification of key peaks will assist detection of metabolites, EPS molecules like polysaccharides, and biologically relevant small organic molecules using ToF-SIMS in future surface and interface research.

59 BASIC BIOLOGICAL SCIENCES↗

ToF-SIMS spectral data analysis of Paenibacillus sp. 300A biofilms and planktonic cells

Analysis of bacterial biofilms is particularly challenging and important with diverse applications from systems biology to biotechnology. Among the variety of techniques that have been applied, time-of-flight secondary ion mass spectrometry (ToF-SIMS) has many promising features in studying the surface characteristics of biofilms. ToF-SIMS offers high spatial resolution and high mass accuracy, which permit surface sensitive analysis of biofilm components. Thus, ToF-SIMS provides a powerful solution to addressing the challenge of bacterial biofilm analysis. This dataset covers ToF-SIMS analysis of Paenibacillus sp. 300A (300A) isolated from the Hanford site in Richland, WA. The strain is known to have metal and sulfur reducing properties and can be used for bioremediation, wastewater treatment, bioengineering and technology development. There is a current need to identify small molecules and fragments produced from bacterial biofilms. Static ToF-SIMS spectra of 300A were obtained using an IONTOF TOF-SIMS V instrument equipped with a 25 keV Bi 3 + metal ion gun. Identified molecules and molecular fragments are compared against known biological databases and the reported peaks have at least 65 ppm mass accuracy. These molecules range from lipids and fatty acids to flavonoids, quinolones, and other naturally occurring organic compounds. It is anticipated that the spectral identification of key peaks will assist detection of metabolites, extracellular polymeric substance molecules like polysaccharides, and biologically relevant small molecules using ToF-SIMS in future surface and interface research of bacterial biofilms.

Biofilms↗

ftmsRanalysis: An R package for exploratory data analysis and interactive visualization of FT-MS data

The high-resolution and mass accuracy of Fourier transform mass spectrometry (FT-MS) has made it an increasingly popular technique for discerning the composition of soil, plant and aquatic samples containing complex mixtures of proteins, carbohydrates, lipids, lignins, hydrocarbons, phytochemicals and other compounds. Thus, there is a growing demand for informatics tools to analyze FT-MS data that will aid investigators seeking to understand the availability of carbon compounds to biotic and abiotic oxidation and to compare fundamental chemical properties of complex samples across groups. We present ftmsRanalysis, an R package which provides an extensive collection of data formatting and processing, filtering, visualization, and sample and group comparison functionalities. The package provides a suite of plotting methods and enables expedient, flexible and interactive visualization of complex datasets through functions which link to a powerful and interactive visualization user interface, Trelliscope. Example analysis using FT-MS data from a soil microbiology study demonstrates the core functionality of the package and highlights the capabilities for producing interactive visualizations.

97 MATHEMATICS AND COMPUTING↗

(Phospho)Proteomic dataset of ischemia- and ultrasound- stimulated mouse cardiac endothelial cells in vitro

Cardiac endothelial cells respond to both ischemia and therapeutic ultrasound; the proteomic changes underlying these responses are unknown. This data article provides raw and processed data resulting from our global, unbiased phosphoproteomics investigation conducted on primary mouse cardiac endothelial cells exposed to ischemia (2-hour oxygen glucose deprivation) and ultrasound (250 kHz, 1.2 MPa) in vitro [1]. Proteins were extracted from cell lysates and enriched phosphopeptides were analyzed with a high mass accuracy liquid chromatrography (LC) - tandem mass spectrometry (MS/MS) proteomic platform, yielding multiple alterations in both total protein levels and phosphorylation events in response to ischemic injury and ultrasound. This dataset can be used as a reference for future studies on the cardiac endothelial response to ischemia and the mechanistic underpinnings of the cellular response to ultrasound, with the potential to yield clinically relevant therapeutic targets.

59 BASIC BIOLOGICAL SCIENCES↗

Toward Revealing Microcystin Distribution in Mouse Liver Tissue Using MALDI-MS Imaging

Cyanotoxins can be found in water and air during cyanobacterial harmful algal blooms (cHABs) in lakes and rivers. Therefore, it is very important to monitor their potential uptake by animals and humans as well as their health effects and distribution in affected organs. Herein, the distribution of hepatotoxic peptide microcystin-LR (MC-LR) is investigated in liver tissues of mice gavaged with this most common MC congener. Preliminary matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS) imaging experiments performed using a non-automated MALDI matrix deposition device and a MALDI-time-of-flight (TOF) mass spectrometer yielded ambiguous results in terms of MC-LR distribution in liver samples obtained from MC-LR-gavaged mice. The tissue preparation for MALDI-MS imaging was improved by using an automated sprayer for matrix deposition, and liver sections were imaged using an Nd:YAG MALDI laser coupled to a 15 Tesla Fourier-transform ion cyclotron resonance (FT-ICR)-mass spectrometer. MALDI-FT-ICR-MS imaging provided unambiguous detection of protonated MC-LR (calculated m/z 995.5560, z = +1) and the sodium adduct of MC-LR (m/z 1017.5380, z = +1) in liver sections from gavaged mice with great mass accuracy and ultra-high mass resolution. Since both covalently bound and free MC-LR can be found in liver of mice exposed to this toxin, the present results indicate that the distribution of free microcystins in tissue sections from affected organs, such as liver, can be monitored with high-resolution MALDI-MS imaging.

59 BASIC BIOLOGICAL SCIENCES↗

GEER Status Update

History: The Glenn Extreme Environments Rig (GEER) first became operational in the early part of 2015. Since that time GEER has completed a number of scientific tests and has undergone improvements in the chemical delivery system and analytics following a year of operations experience. Recent Updates: In June 2016, the GEER process system was rebuilt to provide a more robust system, higher accuracy and new capabilities. New insulation was installed on the exterior of the pressure vessel and gas lines. The newly revamped GEER plumbing system can provide extremely precise custom gas mixtures using any gas desired by the investigator in any combination. GEER can heat the resulting mixture up to 500 deg C and 1500 psia. The 304 stainless steel vessel walls were polished to reduce corrosion rate and reduce unwanted chemical reactions. The process lines were replaced with high purity Sulfinert coated tubing. The GEER team added the ability to individually boost specialty gases to GEER thus allowing operators to make very precise changes to the gas chemistry inside of GEER during a test while at high temperature and pressure. High accuracy mass flow meters were added to further improve gas mixing accuracy and precision. An in-line, integrated Inficon MicroGC Fusion was added for real time gas analysis along with a high purity gas sampling system, providing fully automated, real time analysis of the gas chemistry inside of GEER in minutes. This complements a co-located mass spectrometer and both are used for regular monitoring of the vessel chemistry. All internal vessel components were replaced with polished 304SS equivalents. Hot vent down capability was increased. Finally, an automated liquid injection system was added and is rated for max vessel operating conditions of (1500 psia, 500 C). Recent Results and Publications: In May 2016, GEER completed a test that exposed high temperature electronics to Venus surface conditions for 21.5 days. This demonstrated the potential for operating robotic spacecraft in the Venus environment without the need for thermal or environmental protection. Results from this test were published in December 2016 and received national media attention. In April 2017 GEER implemented an 80 day test at Venus surface conditions to simulate chemical weathering of expected Venus minerals. This test supported a ROSES award to a team led by Prof. Ralph Harvey of Case Western Reserve University. The test concluded in July 2017 and nearly doubled previous operation record of 42 days at Venus surface conditions. Preliminary results of these and previous experiments were presented at the recent Venus Modeling Workshop. In June 2017, NASA TM2017-219437 "Chemical and Microstructural Changes in Metallic and Ceramic Materials Exposed to Venusian Surface Conditions" was published. This report provides an extensive and valuable resource detailing the behavior of a variety of engineering materials at Venus surface conditions. Community Involvement: An external science advisory panel has been formed.

Kremic, Tibor↗

Molecular Characterization of Organophosphorus Compounds in Wildfire Smoke Using 21-T Fourier Transform-Ion Cyclotron Resonance Mass Spectrometry

Here, we present a detailed molecular characterization of organophosphorus compounds in ambient organic aerosol influenced by wildfire smoke. Biomass burning organic aerosol (BBOA) is an important source of phosphorus (P) to surface waters, where even a small imbalance in the P flux can lead to substantial effects on water quality, such as eutrophication, algal blooms, and oxygen depletion. We aimed to exploit the ultrahigh resolving power, mass accuracy, and sensitivity of Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR MS) to explore the molecular composition of an ambient BBOA sample collected downwind of Pacific Northwest wildfires. The 21-T FT-ICR MS yielded 10533 distinct formulae, which included molecular species comprising C, H, O, and P with or without N, i.e., organophosphorus compounds that have long been quantified in wildfire smoke but have not yet been characterized at the molecular level. The lack of detailed molecular characterization of organophosphorus compounds in BBOA is primarily due to their inherently low concentrations in aerosols and poor ionization efficiency in complex mixtures. We demonstrate that the exceptional sensitivity of the 21-T FT-ICR MS allows qualitative analysis of a previously uncharacterized fraction of BBOA without its selective concentration from the organic matrix, exemplifying the need for ultrahigh-resolution tools for a more detailed and accurate molecular depiction of such complex mixtures.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Shifting the Inertial Navigation Paradigm with MEMS Technology

Why don t you use MEMS? is one of the most common questions posed to navigation systems engineers designing inertial navigation solutions in the modern era. The question stems from a general understanding that great strides have been made in terrestrial MEMS accelerometers and attitude rate sensors in terms of accuracy, mass, and power. Yet, when compared on a unit-to-unit basis, MEMS devices do not provide comparable performance (accuracy) to navigation grade sensors. This paper will propose a paradigm shift where the comparison in performance is between multiple MEMS devices and a single navigation grade sensor. The concept is that systematically, a sufficient number of MEMS sensors may mathematically provide comparable performance to a single navigation grade device and be competitive in terms power and mass allocations when viewed on a systems level. The implication is that both inertial navigation system design and fault detection, identification, and recovery could benefit from a system of MEMS devices in the same way that swarm sensing has benefited Earth observation and astronomy. A survey of the state of the art in inertial sensor accuracy scaled by mass and power will be provided to show the specific error in MEMS and navigation graded devices, a mathematical comparison of multi-unit to single-unit sensor errors will be developed, and preliminary applications to Constellation vehicles will be explored.

Crain, Timothy↗

Shifting the Intertial Navigation Paradigm with the MEMS Technology

"Why don't you use MEMS?" is of the most common questions posed to navigation systems engineers designing inertial navigation solutions in the modern era. The question stems from a general understanding that great strides have been made in terrestrial MEMS accelerometers and attitude rate sensors in terms of accuracy, mass, and power. Yet, when compared on a unit-to-unit basis, MEMS devices do not provide comparable performance (accuracy) to navigation grade sensors in several key metrics. This paper will propose a paradigm shift where the comparison in performance is between multiple MEMS devices and a single navigation grade sensor. The concept is that systematically, a sufficient number of MEMS sensors may mathematically provide comparable performance to a single navigation grade device and be competitive in terms power and mass allocations when viewed on a systems level. The implication is that both inertial navigation system design and fault detection, identification, and recovery could benefit from a system of MEMS devices in the same way that swarm sensing has benefited Earth observation and astronomy. A survey of the state of the art in inertial sensor accuracy scaled by mass and power will be provided to show the scaled error in MEMS and navigation graded devices, a mathematical comparison of multi-unit to single-unit sensor errors will be developed, and preliminary application to an Orion lunar skip atmospheric entry trajectory will be explored.

Crain, Timothy P., II↗

193 nm Ultraviolet Photodissociation for the Characterization of Singly Charged Proteoforms Generated by MALDI

MALDI imaging allows for the near-cellular profiling of proteoforms directly from microbial, plant, and mammalian samples. Despite detecting hundreds of proteoforms, identification of unknowns with only intact mass information remains a distinct challenge, even with high mass resolving power and mass accuracy. To this end, many supplementary methods have been used to create experimental databases for accurate mass matching, including bulk or spatially resolved bottom-up and/or top-down proteomics. Herein, we describe the application of 193 nm ultraviolet photodissociation (UVPD) for fragmentation of quadrupole isolated singly charged ubiquitin (m/z 8565) by MALDI-UVPD on a UHMR HF Orbitrap. This platform permitted the high-resolution accurate mass measurement of not just terminal fragments but also large internal fragments. Finally, the outlined workflow demonstrates the feasibility of top-down analyses of isolated MALDI protein ions and the potential toward more comprehensive characterization of proteoforms in MALDI imaging applications.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Improved high-precision mass measurements of mid-shell neon isotopes

New mass values measured with the TITAN MR-TOF-MS are reported for the short-lived isotopes 24-26 Ne, produced at TRIUMF's ISAC facility using a uranium carbide target and cold FEBIAD ion source. A least-squares adjustment within the framework of the Atomic Mass Evaluation was performed and the improved precision of the new mass values is highlighted. The improved mass accuracy in this N = 14mid-shell region can also point to the refinement in values of the charge radii. By reducing the mass uncertainty of isotopes, their contribution of the mass shift uncertainty in laser spectroscopy can be negated. The work is part of developments for reaching the N = 20 Island of Inversion, where high molecular contamination hinders mass measurements of the neon isotopes.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Data Set Analysis to Reduce Uncertainty in Formula Assignments of Ultrahigh Resolution Mass Spectra

Environmental samples contain a vast array of organic compounds with diverse elemental compositions and heteroatom content. Molecular formula assignments of ultrahigh resolution mass spectra (HRMS) hold promise for elucidating the molecular composition of these compounds. However, the need to account for an assortment of heteroatoms increases the uncertainty associated with individual assignments – and ultimately the ecological, biological, and biogeochemical insights gleaned from the assignments. To address this challenge, we introduce a formula assignment strategy that leverages HRMS data sets to improve assignment confidence, filter false assignments, and mitigate bias in assignment routines. The strategy, implemented using CoreMS, first identifies the highest confidence assignment for a recurring ion in a data set by assessing the mass accuracy and isotopologue similarity of all assignments to the ion across the data set. The second component of the strategy examines the consistency of mass errors for an assigned ion throughout a data set and flags formulas with statistically unlikely deviations in mass error. Here, we illustrate the application and utility of the strategy by comparing its results against documented misassignment patterns within a set of oceanographic samples that were measured with 21 T Fourier Transform Ion Cyclotron Resonance Mass Spectrometry. Because the efficacy of our strategy improves with data set size, it is particularly useful for enhancing assignment confidence in large HRMS data sets common in studies of environmental systems.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

2023 American Society for Mass Spectrometry (ASMS) 71st Annual Conference on Mass Spectrometry and Allied Topics

Introduction (120 words max) Understanding metal-cluster chemistry occuring at solvent boundaries in the aqueous and organic phases has applications in environments from cellular processes to nuclear fuel reprocessing. Transport of metal ions at the boundaries from aqueous to organic phases involves forming a metal-ligand complex, and wherever the initial metal coordination environment is significantly different from the final one, the metal transitions through a series of transient species in passing from one phase to another. Here an investigation of the role of coordination in the chemistry of the transient species using gas-phase measurements that are free of solvent effects to better understand the binding of complexes of metals with triphenylphosphine chalcogenide ligands, examining metal-ligand homo- and hetero-dimers to better understand transient species. Methods (120 word max) Mass spectrometry and collision induced dissociation (CID) experiments were performed with a Bruker (Billerica, MA, USA) micrOTOF-Q II quadrupole time-of-flight mass spectrometer (QTOF) and Bruker amaZon speed ETD (ion trap). High resolution/high mass accuracy spectra were generated using the QTOF. External calibration was performed with Agilent (Santa Clara, CA, USA) ESI-L Low Concentration tuning mix. Both mass spectrometers were equipped with either the electrospray ionization source or nanospray sources. Metal samples were prepared between 40 – 60 uM of the metal-ligand complex in 25% water and 75% acetonitrile. Metal-ion clusters were isolated and subjected to collision induced dissociation. Density functional theory calculations were performed. Preliminary Data or Plenary Speakers Abstract (300 words max) Metal ion clusters with triphenylphosphine chalcogenide ligands were observed for group I metals with triphenylphosphine chalcogenide samples in the mass spectrum upon electrospray ionization. For each metal ligand complex of interest, the parent ion was isolated and collision induced dissociation fragmentation spectra were acquired. We observed clusters of group I metal with triphenylphosphine oxide, triphenyl phosphine sulfide, and triphenylphosphine selenide, with homodimers and heterodimer formation. In samples where the ligands were mixed, we observed mixed sodium ligand clusters at varying amounts. These mixed ligand clusters were fragmented. Metal clusters of mixed ligand dimers containing triphenylphosphine oxide showed preferential loss of the other ligand, either triphenylphosphine sulfide or triphenyl selenide. In samples with mixed triphenylphosphine sulfide and triphenylphosphine selenium ligands, sodium bound similarly between the ligands, and losses were more evenly split, showing loss ratio upon CID with losses of triphenylphosphine sulfide:triphenylphosphine selenide 43:57 ratio observed on CID. These results suggest that the oxide binds significantly more strongly than either the selenium or sulfur triphenylphosphine ligand, and the sulfur and selenium ligands are more evenly bound. Calculations were performed using density functional theory to calculate likely structures and bond energies between the group I metal and the ligands. Novel Aspect Novel analysis of sodium bound dimers with chalcogenide triphenylphosphine ligands were investigated using mass spectrometry and theoretical calculations.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Ambient Single-Cell Analysis and Native Tissue Imaging Using Laser-Ablation Electrospray Ionization Mass Spectrometry with Increased Spatial Resolution

Laser ablation electrospray ionization mass spectrometry (LAESI-MS) is an emerging method that has the potential to transform the field of metabolomics. This is in part due to LAESI-MS being an ambient ionization method that requires minimal sample preparation and uses (endogenous) water for in situ analysis. This application note details the employment of the ‘LAESI microscope’ source to perform spatially resolved MS analysis of cells and MS imaging (MSI) of tissues at high spatial resolution. This source configuration utilizes a long-working distance reflective objective that permits both visualization of the sample and a smaller LAESI laser beam profile than conventional LAESI setups. In this work, we analyzed 200 single cells of Allium cepa (red onion) and imaged Fittonia argyroneura (nerve plant) in high spatial resolution using this source coupled to a Fourier transform mass spectrometer for high mass resolution and high mass accuracy metabolomics.

59 BASIC BIOLOGICAL SCIENCES↗

Review: Recent advances of ToF-SIMS for environmental analysis and imaging

Background: Time-of-flight secondary ion mass spectrometry (ToF-SIMS) is a powerful surface analysis technique, initially developed and applied in inorganic materials and semiconductors. In past decades, ToF-SIMS has attracted more attention in its analysis capabilities of organic materials, with increased applications in biology, medical, and health development. It has also become a versatile and effective tool in environmental analysis due to its high mass resolution, mass accuracy, and depth profiling. Results: In this review, we first give an overview of the principle of ToF-SIMS and follow with recent ToF-SIMS applications in exemplary environmental study cases, including atmospheric aerosol, soil, water, plant, and organic solvent analysis. Moreover, sample preparation techniques are summarized in relation to corresponding environmental applications. Specifically, we call attention to ToF-SIMS investigations showcasing studies in surface chemical compositions, images, and depth profile analysis. These findings emphasize the important role of interfacial chemistry in environmental processes and provide valuable insights into dynamic processes, such as chemical transformation, particle formation, plant biology, and microbial inspired biotechnology development. The mass spectral imaging results acquired by ToF-SIMS offer a deeper understanding of intermediate stages and transient phases for environmental specimens. Significance: In situ and operando imaging offer new possibilities in studying phenomena in real time with high spatial resolution. Furthermore, it is anticipated that more research groups will use ToF-SIMS in environmental research given recent advances in measurement capabilities and surging needs in chemical mapping of complex analytes and systems.

Aerosol↗

Chimera Spectrum Diagnostics for Peptides Using Two-Dimensional Partial Covariance Mass Spectrometry

The rate of successful identification of peptide sequences by tandem mass spectrometry (MS/MS) is adversely affected by the common occurrence of co-isolation and co-fragmentation of two or more isobaric or isomeric parent ions. This results in so-called `chimera spectra’, which feature peaks of the fragment ions from more than a single precursor ion. The totality of the fragment ion peaks in chimera spectra cannot be assigned to a single peptide sequence, which contradicts a fundamental assumption of the standard automated MS/MS spectra analysis tools, such as protein database search engines. This calls for a diagnostic method able to identify chimera spectra to single out the cases where this assumption is not valid. Here, we demonstrate that, within the recently developed two-dimensional partial covariance mass spectrometry (2D-PC-MS), it is possible to reliably identify chimera spectra directly from the two-dimensional fragment ion spectrum, irrespective of whether the co-isolated peptide ions are isobaric up to a finite mass accuracy or isomeric. We introduce ‘3-57 chimera tag’ technique for chimera spectrum diagnostics based on 2D-PC-MS and perform numerical simulations to examine its efficiency. We experimentally demonstrate the detection of a mixture of two isomeric parent ions, even under conditions when one isomeric peptide is at one five-hundredth of the molar concentration of the second isomer.

47 OTHER INSTRUMENTATION↗