Search NASA⌕ Search

SEARCH · Search NASA

Results for “mass spectrometry analysis”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

A Simple and Flexible Infusion Platform for Automated Native Mass Spectrometry Analysis

High throughput native mass spectrometry analysis of proteins and protein complexes has been enabled by recent development of infusion and liquid chromatography (LC) systems, which often include complete LC pumps without fully utilizing their gradient flows. We demonstrated a lower-cost infusion cart for native mass spectrometry applications using a single isocratic solvent pump that can operate at both nano- and high-flow configurations (0.05-150 $μ$L/min) for both infusion and online buffer exchange experiments. In conclusion, the platform is controlled via open-source software and can potentially be expanded for customized experimental designs, offering a lower cost alternative to laboratories with limited budgets and/or needs in student training.

47 OTHER INSTRUMENTATION↗

Workflow for High-throughput Screening of Enzyme Mutant Libraries Using Matrix-assisted Laser Desorption/Ionization Mass Spectrometry Analysis of Escherichia coli Colonies

High-throughput molecular screening of microbial colonies and DNA libraries are critical procedures that enable applications such as directed evolution, functional genomics, microbial identification, and creation of engineered microbial strains to produce high-value molecules. A promising chemical screening approach is the measurement of products directly from microbial colonies via optically guided matrix-assisted laser desorption/ionization mass spectrometry (MALDI-MS). Measuring the compounds from microbial colonies bypasses liquid culture with a screen that takes approximately 5 s per sample. We describe a protocol combining a dedicated informatics pipeline and sample preparation method that can prepare up to 3,000 colonies in under 3 h. The screening protocol starts from colonies grown on Petri dishes and then transferred onto MALDI plates via imprinting. The target plate with the colonies is imaged by a flatbed scanner and the colonies are located via custom software. The target plate is coated with MALDI matrix, MALDI-MS analyzes the colony locations, and data analysis enables the determination of colonies with the desired biochemical properties. This workflow screens thousands of colonies per day without requiring additional automation. The wide chemical coverage and the high sensitivity of MALDI-MS enable diverse screening projects such as modifying enzymes and functional genomics surveys of gene activation/inhibition libraries.

Choe, Kisurb↗

Vacuum Pyrolysis of Hybrid Poplar Milled Wood Lignin with Fourier Transform-Ion Cyclotron Resonance Mass Spectrometry Analysis of Feedstock and Products for the Elucidation of Reaction Mechanisms

The pyrolysis of lignocellulosic materials is a promising technique to produce fuels and chemicals. It is well known that the most abundant products of lignin pyrolysis are oligomeric molecules, known as pyrolytic lignin (PL). The chemical composition of PL has been extensively studied; however, there is still an important debate whether these oligomers are produced directly from the lignin or from the recombination of monomeric pyrolytic products. Existing theories are unable to describe the effect of vacuum on the distribution of pyrolysis products. Hybrid poplar milled wood lignin (MWL) was initially isolated and thoroughly characterized by Fourier transform-ion cyclotron resonance mass spectrometry (FT-ICR MS). Chemical formulas were assigned to each oligomeric compound detected. The MWL was also subjected to vacuum pyrolysis in a modified pyroprobe at 250, 750, and 1000 mbar (absolute pressure), and the resulting liquid products were analyzed by FT-ICR MS. A new strategy to assign structural representations to the oligomeric PL products is proposed, based on the plausible pyrolysis reaction mechanisms of depolymerization/fragmentation applied to original MWL oligomer formulas. Our results support the hypothesis that PL is formed from the removal of moieties from primary lignin pyrolysis products with between three and five aromatic rings. This depolymerization/fragmentation allows the oligomers to reduce their molecular weights to the point where they can be removed from the reaction zone by direct vaporization. Furthermore, this phenomenon highlights the importance of pressure on removal mechanisms and their impact on the molecular weight of the resulting products from lignin pyrolysis.

09 BIOMASS FUELS↗

Product specific thermal degradation kinetics of bisphenol F epoxy in inert and oxidative atmospheres using evolved gas analysis–mass spectrometry

Knowledge of the degradation kinetics for polymer materials is important for understanding thermal stability. In this study, evolved gas analysis–mass spectrometry and pyrolysis gas-chromatography-mass spectrometry were evaluated for the potential to deliver additional insight into thermal degradation kinetics of diglycidal ether of bisphenol F (DGEBF) epoxy thermoset under inert and oxidative atmospheres. Degradation products of selected precursor ions were evaluated for their uniqueness to the specific precursor using extracted ion thermographs. Unique mass peaks, solely attributed to a single reaction pathway of a specific product, were determined from extracted ion thermographs and used to determine both activation energy (E a ) and pre-exponential factors for the specific primary reaction pathways. These primary reaction pathways for DGEBF epoxy degradation were then evaluated in the context of transition state theory (TST) and related transition state enthalpies (ΔH ‡ ) and entropies (ΔS ‡ ) of activation to further elucidate the degradation process. It was determined under pyrolysis conditions, as suggested by the E a , the formation of bisphenol F monomer was the rate-limiting step toward the formation of xanthene and phenol. In contrast, under thermo-oxidative conditions, reactions involving oxygen containing species were identified as the rate-limiting step for all observed products based on the large negative ΔS ‡ calculated from TST. This work demonstrates a powerful combination of technique and theory that can provide new insight into the degradation of polymer materials.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Evolved Gas Analysis–Mass Spectrometry Exposes Polymer Network Structures

Polymer network structures in epoxy thermosets play an important role in the final thermoset material properties. However, analytical characterization of these network structures is difficult due to their amorphous nature. In this work, the application of evolved gas analysis–mass spectrometry (EGA-MS) to characterize the polymer network structures of bisphenol A (BPA)-based thermosets is demonstrated. Analytical characterization of the polymer network structures is accomplished by monitoring the Product-Specific Kinetics (PSK) of BPA monomer formation during thermal degradation investigations. We relate observed differences in the activation energy (E a ) of BPA monomer formation to the local packing environment around the BPA monomer units within the polymer network. Variations in the local environment related to the polymer networks manifest qualitatively as broadening in the thermal profile of the BPA monomer evolution and quantitatively as changes in the activation energy (E a ). Three BPA thermoset formulations were investigated; two amine-cured thermoset with 4,4′-diaminodiphenylmethane (DDM) or poly(propylene glycol) bis(2-amino-propyl ether) (PPG400) and a homopolymerized thermoset via curing with Epikure 3253 catalyst (3253). Results revealed that the 3253 thermoset contained two distinct packing densities in the polymer network, while DDM and PPG400 thermosets had uniform distributions of packing densities. Results from the DDM thermoset revealed a gradually decreasing E a , while the apparent E a of PPG400 was consistent over the entire degradation. Furthermore, these differences in E a were concluded to stem from the flexibility of the corresponding polymer networks and the ability of the network components to rearrange and occupy formed voids. Due to the minimal sample required for analysis (100–200 μg), this EGA-MS technique has great potential for postproduction evaluation of composite parts to identify changes in the polymer networks from use and aging, which could signal compromised performance.

Degradation↗

HPLC-Parallel accelerator and molecular mass spectrometry analysis of 14 C-labeled amino acids

Accelerator mass spectrometry (AMS) is the method of choice for quantitation of low amounts of 14 C-labeled biomolecules. Despite exquisite sensitivity, an important limitation of AMS is its inability to provide structural information about the analyte. This limitation is not critical when the labeled compounds are well-characterized prior to AMS analysis. However, analyte identity is important in other experiments where, for example, a compound is metabolized and the structures of its metabolites are not known. We previously described a moving wire interface that enables direct AMS measurement of liquid sample in the form of discrete drops or HPLC eluent without the need for individual fraction collection, termed liquid sample-AMS (LS-AMS). Here, we now report the coupling of LS-AMS with a molecular mass spectrometer, providing parallel accelerator and molecular mass spectrometry (PAMMS) detection of analytes separated by liquid chromatography. The repeatability of the method was examined by performing repeated injections of 14 C-labeled tryptophan, and relative standard deviations of the 14 C peak areas were ≤10.57% after applying a normalization factor based on a standard. Five 14 C-labeled amino acids were separated and detected to provide simultaneous quantitative AMS and structural MS data, and AMS results were compared with solid sample-AMS (SS-AMS) data using Bland-Altman plots. To demonstrate the utility of the workflow, yeast cells were grown in a medium with 14 C-labeled tryptophan. The cell extracts were analyzed by PAMMS, and 14 C was detected in tryptophan and its metabolite kynurenine.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

Parts-Per-Million Carbonate Mineral Quantification with Thermogravimetric Analysis–Mass Spectrometry

Mitigating the deleterious effects of climate change requires the development and implementation of carbon capture and storage technologies. To expand the monitoring, verification, and reporting (MRV) capabilities of geologic carbon mineralization projects, we developed a thermogravimetric analysis–mass spectrometry (TGA–MS) methodology to enable quantification of <100 ppm calcite (CaCO 3 ) in complex samples. We extended TGA–MS calcite calibration curves to enable a higher measurement resolution and lower limits of quantification for evolved CO 2 from a calcite–corundum mixture. We demonstrated <100 ppm carbonate mineral quantification with TGA–MS for the first time, an outcome applicable across earth, environmental, and materials science fields. We applied this carbonate quantification method to a suite of Columbia River Basalt Group (CRBG) well cuttings recovered in 2009 from Pacific Northwest National Laboratory’s Wallula #1 Well. Our execution of this new combined calcite and calcite–corundum calibration curve TGA–MS method on our CRBG sample suite indicated average carbonate contents of 0.050 wt % in flow interiors (caprocks) and 0.400 wt % in interflow zones (reservoirs) in the upper 1250 m of the Wallula #1 Well. Finally, by advancing our knowledge of continental flood basalt-hosted carbonates in the mafic subsurface and reaching new TGA–MS quantification limits for carbonate minerals, we expand MRV capabilities and support the commercial-scale deployment of carbon mineralization projects in the Pacific Northwest United States and beyond.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Model-based compositional predictions for a differential scanning calorimetry/thermogravimetric analysis-mass spectrometry system used for heat of vaporization measurements

A Differential Scanning Calorimetry/Thermogravimetric Analysis (DSC/TGA) procedure for determination of Heat of Vaporization (HOV) of fuel and surrogate fuel mixtures has been previously utilized for evaluation of oxygenate impacts on spark ignition fuels. This analysis has been further leveraged with mass spectrometry (MS) to elucidate vapor phase compositional changes during evaporation. In this study we focus on a simple system of three compounds (ethanol, n-hexane, and n-octane) to provide a model-based understanding of the evaporation process under these experimental conditions. An Aspen Plus model was set up to provide liquid and vapor phase concentration predictions during mixture evaporation using the initial mixture composition, and measured temperature and mass loss profiles from DSC/TGA experiments. Agreements between the trends of the MS ion count profiles and model composition predictions provide a degree of validation of this modeling approach that can allow the interpretation and extrapolation of DSC/TGA measurements for more complex fuel mixtures.

33 ADVANCED PROPULSION SYSTEMS↗

Comparability of Liquid Chromatography Tandem Mass Spectrometry Analysis of Dissolved Organic Matter across Laboratories

Non-targeted liquid chromatography tandem highresolution mass spectrometry (LC−MS/MS) is increasingly applied for the structure-resolved chemical analysis of dissolved organic matter (DOM). With new developments in MS instrumentation and analysis software, the approach has gained substantial momentum over the past decade. However, achieving high-quality analytical data that is reproducible and comparable across laboratories can be a bottleneck in non-targeted metabolomics and organic matter chemical analysis, especially for data reuse in repository-scale analyses. Understanding the capabilities as well as challenges of comparing LC−MS/MS data from different laboratories is necessary for inferring global trends from public data sets. To illuminate instrumentation factors that drive differences and variability, we used a standardized data analysis pipeline, including classical (CMN) and featurebased molecular networking (FBMN), to analyze data from a ring trial by 24 laboratories on identical sample sets of algal and DOM extracts that were mixed in predefined concentrations and spiked with standards. Our results showed that data sets from similar mass spectrometer types with unified instrument parameters were qualitatively comparable, resolving the same general trends and shared mass spectral features. Interlaboratory comparability was best for high-intensity features, while low-intensity features showed greater detection variability. Our analysis also highlights challenges when comparing data from instruments with different acquisition rates or operating with less standardized methods. Lastly, we provide recommendations for data integration, public data sharing, standardization, and best practices for standardized LC−MS/MS data acquisition, which will be critical for long-term time series and intercomparability of DOM chemical analyses.

DOM↗

Rapid Droplet Sampling Interface for Low-Volume, High-Throughput Mass Spectrometry Analysis

Here, we present a rapid droplet sampling interface (RDSI) electrospray ionization mass spectrometry (ESI-MS) system as a high-throughput, low-volume, noncontact, and minimal-carryover approach for characterization of liquids. Liquid characterization was achieved by combining droplet ejection with an open-face microflow capillary with a 2.5 μL/min continuous flow of carrier solvent. Through this implementation, single 0.3 nL droplets containing the analyte effectively mix with 4–8 nL of carrier solvent and create a combined electrospray plume. The carrier solvent continuously cleaned the system, eliminating carryover. A sampling rate of 5 Hz was achieved for droplets containing 1 μM propranolol or 5 μM leu-enkephalin with each droplet fully baseline-resolved (138 ± 32 ms baseline-to-baseline). Using a SCIEX API4000 mass spectrometer, a lower limit of quantification (LLOQ) of propranolol was 15 nM, corresponding to 1.16 fg of propranolol in the droplet, and was linear across 3 orders of magnitude. Further, quantitation could be achieved by adding an isotopically labeled internal standard, as done in conventional ESI. Signal transients were faster than the acquisition speed of the mass spectrometer, resulting in artificially high reproducibility of 15–30% RSD droplet-to-droplet. Analyte–solvent mixing ratios could be controlled by adjusting droplet positioning along the open-face capillary with an optimal position about 0.4 mm from the tip end. The range of analyte coverage was exemplified by measures of peptides and drugs in methanol, water, and buffer solutions. In a comparison to the Open Port Sampling Interface (OPSI) implemented on the same system, the RDSI had 78× greater sensitivity, 6× greater throughput and used significantly less carrier solvent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High-throughput mass spectrometry analysis using immediate drop-on-demand technology coupled with an open port sampling interface

Rationale: The sampling throughput of immediate drop-on-demand technology (I.DOT) coupled with an open port sampling interface (OPSI) is limited by software communication. To enable much-needed high-throughput mass spectrometry (MS) analysis capabilities, a novel software was developed that allows for flexible sample selection from a 96-well plate and for maximized analysis throughput using I.DOT/OPSI-MS coupling. Methods: Wells of a 96-well I.DOT plate were filled with propranolol solution and were used to test maximum sampling throughput strategies to minimize analysis time. Demonstration of chemical reaction monitoring was done using acid-catalyzed ring closure of 2,3-diaminonaphthalene (DAN) with nitrite to form 2,3-naphthotriazole (NAT). Analytes were detected in positive electrospray ionization mode using selected reaction monitoring. Results: A maximum throughput of 1.54 s/sample (7.41 min/96-well plate with three technical replicates) was achieved, and it was limited by the peak width of the MS signal resulting in an occasional slight overlap between the peaks. Further, relative standard deviation was 10 ± 1% with all tested sampling strategies. Chemical reaction monitoring of DAN to NAT using nitrite was successfully accomplished with 2 s/sample throughout showing almost complete transformation in 10 min with no signal overlap. Conclusions: This work illustrates the development of a noncontact, automated I.DOT/OPSI-MS system with improved throughput achieved through an optimized software interface. Its achievable analysis time and precision make it a viable approach for drug discovery and in situ reaction monitoring studies.

47 OTHER INSTRUMENTATION↗

Pyrolysis_Molecular_Beam_Mass_Spectrometry_Analysis_of_Specific_Switchgrass_Genotypes

Select natural variant switchgrass genotypes grown in Tifton, GA were analyzed by Pyrolysis-Molecular Beam Mass Spectrometry (Py-MBMS). Biomass was harvested, milled, several genotypes were analyzed with and without being destarched and extracted with ethanol prior to analysis (indicated with -DE if destarched and extracted). Py-MBMS analysis was conducted using approximately 4 mg of biomass and each sample was analyzed in duplicate. A Frontier PY2020 unit pyrolyzed samples at 500°C for 30 s in 80 µL deactivated stainless steel cups. An Extrel Super-Sonic MBMS Model Max 1000 was used to collect mass spectral data fromm/z30 to 450 at 17 eV and processed using Merlin Automation software (V3). Spectral ion intensities were normalized to the total ion chromatogram signal for each sample for analysis of spectral variance. Lignin content (wt %) was estimated based on relative responses from standards of known Klason lignin content using mean-normalized ion intensities ofm/z120, 124 (G), 137 (G), 138 (G), 150 (G), 152, 154 (S), 164 (G), 167 (S), 168 (S), 178 (G), 180, 181, 182 (S), 194 (S), 208 (S) and 210 (S) where G indicates guaiacyl-derived ions, S indicates syringyl-derived ions, and other ions either derive from other lignin monomers or multiple sources. Ratios of S and G lignin monomer units (S/G) were obtained by dividing the sum of S-based ions by the sum of G-based ions using mean-normalized ion intensities.

CBI↗

Interlaboratory comparison of secondary ion mass spectrometry analysis results from the 7th international technical nuclear forensics working group collaborative material exercise

A review and interlaboratory comparison of secondary ion mass spectrometry (SIMS) data obtained by laboratories participating in the International Technical Nuclear Forensics Working Group (ITWG) 7th Collaborative Material Exercise (CMX-7) has been conducted. The analyzed materials were two uranium compounds in powder form and two pieces of uranium metal. The instruments used in this comparison were a small-geometry (SG) SIMS, CAMECA IMS 7f from the Research Centre Rez, and a large-geometry (LG) SIMS, CAMECA IMS 1280 from Los Alamos National Laboratory. Despite the differences in instruments and analytical procedures, e.g., sample preparation, SIMS setups, and data post-processing, there was good agreement for the 234 U/ 238 U, 235 U/ 238 U, and 236 U/ 238 U ratios in the analyzed materials. The main difference was in the precision, which was, as expected, higher for the LG-SIMS. In addition, a comparison between the laboratories was also made for the image processing algorithms applied to raw data acquired in automated particle measurement (APM) mode. In conclusion, the result of this comparison has led to identification of best practices for setting up parameters of the APM software.

and nuclear chemistry↗

Pyrolysis Molecular Beam Mass Spectrometry_Analysis_of_Natural_Variants_of_Poplulus_Trichocarpa_Leaves

Select leaves from natural variants of Poplar (Populus Trichocarpa) grown in a greenhouse at Oak Ridge National Laboratory were analyzed by Pyrolysis-Molecular Beam Mass Spectrometry (Py-MBMS). Leaves were harvested, cryomilled and kept frozen until analysis. Py-MBMS analysis was conducted using approximately 4 mg of biomass and each sample was analyzed in duplicate. A Frontier PY2020 unit pyrolyzed samples at 500°C for 30 s in 80 µL deactivated stainless steel cups. An Extrel Super-Sonic MBMS Model Max 1000 was used to collect mass spectral data fromm/z30 to 450 at 17 eV and processed using Merlin Automation software (V3). Spectral ion intensities were normalized to the total ion chromatogram signal for each sample for analysis of spectral variance. Lignin content (wt %) was estimated based on relative responses from standards of known Klason lignin content using mean-normalized ion intensities ofm/z120, 124 (G), 137 (G), 138 (G), 150 (G), 152, 154 (S), 164 (G), 167 (S), 168 (S), 178 (G), 180, 181, 182 (S), 194 (S), 208 (S) and 210 (S) where G indicates guaiacyl-derived ions, S indicates syringyl-derived ions, and other ions either derive from other lignin monomers or multiple sources. Ratios of S and G lignin monomer units (S/G) were obtained by dividing the sum of S-based ions by the sum of G-based ions using mean-normalized ion intensities.

CBI↗

Pyrolysis_Molecular_Beam_Mass_Spectrometry_Analysis_of_hybrid_cross_of_Populus_tremula_x_P_alba_717-1B4_and_overexpression_of_a_lectin_receptor-like_kinase_(PtLecRLK1)

Stem tissues from the hybrid poplarPopulus tremula × P. albaclone 717-1B4 and from lectin receptor-like kinase overexpression lines PP7 and PP19 were individually colonized with the ectomycorrhizal fungiLaccaria bicolorstrain S238N,Hyaloscypha finlandicastrain PMI746, orUmbelopsis vinaceastrain PMI3018, as well as with a mixed fungal inoculum; non-inoculated plants served as controls. Plants were grown in a greenhouse at Oak Ridge National Laboratory and harvested in January 2025. Stem samples were analyzed using Pyrolysis–Molecular Beam Mass Spectrometry (Py-MBMS). Stems were harvested, debarked, dried, milled, destarched and ethanol extracted prior to analysis. Py-MBMS analysis was conducted using approximately 4 mg of wood from biomass and each sample was analyzed in duplicate. A Frontier PY2020 unit pyrolyzed samples at 500°C for 30 s in 80 µL deactivated stainless steel cups. An Extrel Super-Sonic MBMS Model Max 1000 was used to collect mass spectral data fromm/z30 to 450 at 17 eV and processed using Merlin Automation software (V3). Spectral ion intensities were normalized to the total ion chromatogram signal for each sample for analysis of spectral variance. Lignin content (wt %) was estimated based on relative responses from standards of known Klason lignin content using mean-normalized ion intensities ofm/z120, 124 (G), 137 (G), 138 (G), 150 (G), 152, 154 (S), 164 (G), 167 (S), 168 (S), 178 (G), 180, 181, 182 (S), 194 (S), 208 (S) and 210 (S) where G indicates guaiacyl-derived ions, S indicates syringyl-derived ions, and other ions either derive from other lignin monomers or multiple sources. Ratios of S and G lignin monomer units (S/G) were obtained by dividing the sum of S-based ions by the sum of G-based ions using mean-normalized ion intensities.

CBI↗

Improving Peptide-Level Mass Spectrometry Analysis via Double Competition

A critical statistical task in the analysis of shotgun proteomics data involves controlling the false discovery rate (FDR) among the reported set of discoveries. This task is most commonly solved at the peptide-spectrum match (PSM) level by using target-decoy competition (TDC), in which a set of observed spectra are searched against a database containing a mixture of real (target) and decoy peptides. The PSM-level procedure can be adapted to the peptide level by selecting the top-scoring PSM per peptide prior to FDR estimation. Here, we investigate both PSM-level and peptide-level FDR control methods and come to two conclusions. First, although the TDC procedure is provably correct under certain assumptions, we observe that one of these assumptions - that incorrect PSMs are independent of one another - is frequently violated. Hence, we empirically demonstrate that TDC-based PSM-level FDR estimates can be liberally biased. Further, we propose that researchers avoid PSM-level results and instead focus on peptide-level analysis. Second, we investigate three ways to carry out peptide level TDC and show that the most common method ("PSM-only") offers the lowest statistical power in practice. The most powerful method, peptide-level FDR with PSM competition ("PSM-and-peptide"), carries out competition first at the PSM level and then again at the peptide level. In our experiments, this approach yields an average increase of 17% more discovered peptides at a1% FDR threshold relative to the PSM-only method.

59 BASIC BIOLOGICAL SCIENCES↗