Search NASA⌕ Search

SEARCH · Search NASA

Results for “matrix sampling”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Modeling Background Attenuation by Sample Matrix in Gamma Spectrometric Analyses

In laboratory gamma spectrometric analyses, the procedures for estimating background usually overestimate it. If an empty container similar to that used to hold samples is measured, it does not consider the background attenuation by sample matrix. If a 'blank' sample is measured, the hypothesis that this sample will be free of radionuclides is generally not true. The activity of this 'blank' sample is frequently sufficient to mask or to overwhelm the effect of attenuation so that the background remains overestimated. In order to overcome this problem, a model was developed to obtain the attenuated background from the spectrum acquired with the empty container. Beyond reasonable hypotheses, the model presumes the knowledge of the linear attenuation coefficient of the samples and its dependence on photon energy and samples densities. An evaluation of the effects of this model on the Lowest Limit of Detection (LLD) is presented for geological samples placed in cylindrical containers that completely cover the top of an HPGe detector that has a 66% relative efficiency. The results are presented for energies in the range of 63 to 2614keV, for sample densities varying from 1.5 to 2.5 g{center_dot}cm{sup -3}, and for the height of the material on the detector of 2 cm and 5 cm. For a sample density of 2.0 g{center_dot}cm{sup -3} and with a 2cm height, the method allowed for a lowering of 3.4% of the LLD for the energy of 1460keV, from {sup 40}K, 3.9% for the energy of 911keV from {sup 228}Ac, 4.5% for the energy of 609keV from {sup 214}Bi, and8.3% for the energy of 92keV from {sup 234}Th. For a sample density of 1.75 g{center_dot}cm{sup -3} and a 5cm height, the method indicates a lowering of 6.5%, 7.4%, 8.3% and 12.9% of the LLD for the same respective energies.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

A data-driven approach to sampling matrix selection for compressive sensing

Sampling is a fundamental aspect of any implementation of compressive sensing. Typically, the choice of sampling method is guided by the reconstruction basis. However, this approach can be problematic with respect to certain hardware constraints and is not responsive to domain-specific context. We propose a method for defining an order for a sampling basis that is optimal with respect to capturing variance in data, thus allowing for meaningful sensing at any desired level of compression. We focus on the Walsh-Hadamard sampling basis for its relevance to hardware constraints, but our approach applies to any sampling basis of interest. We illustrate the effectiveness of our method on the Physical Sciences Inc. Fabry-Perot interferometer sensor multispectral dataset, the Johns Hopkins Applied Physics Lab FTIR-based longwave infrared sensor hyperspectral dataset, and a Colorado State University Swiss Ranger depth image dataset. The spectral datasets consist of simulant experiments, including releases of chemicals such as GAA and SF6. We combine our sampling and reconstruction with the adaptive coherence estimator (ACE) and bulk coherence for chemical detection and we incorporate an algorithmic threshold for ACE values to determine the presence or absence of a chemical. We compare results across sampling methods in this context. We have successful chemical detection at a compression rate of 90%. For all three datasets, we compare our sampling approach to standard orderings of sampling basis such as random, sequency, and an analog of sequency that we term `frequency.' In one instance, the peak signal to noise ratio was improved by over 30% across a test set of depth images.

compressive sensing, hyperspectral imaging, Walsh-↗

Rapid separation and purification of uranium and plutonium from dilute-matrix samples

This work presents a streamlined separation and purification approach for trace uranium and plutonium from dilute (carrier-free) matrices. The method, effective for nanogram quantities of U and femtogram to picogram quantities of Pu, is ideally suited for environmental swipe samples that contain a small amount of collected bulk material. As such, it may be applicable for processing swipe samples such as those collected in IAEA inspection activities as well as swipes that are loaded with unknown analytes, such as those implemented in interlaboratory round-robin or proficiency tests. Additionally, the simplified actinide separation could find use in internal laboratory monitoring of clean room conditions prior to or following more extensive chemical processing. We describe key modifications to conventional techniques that result in a relatively rapid, cost-effective, and efficient U and Pu separation process. We demonstrate the efficacy of implementing anion exchange chromatography in a single column approach. We also show that hydrobromic acid is an effective substitute in lieu of hydroiodoic acid for eluting Pu. Lastly, we show that nitric acid is an effective digestion agent in lieu of perchloric acid and/or hydrofluoric acid. A step by step procedure of this process is detailed.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

LLNL measurements of thermally irradiated HEU sample and saltwater-matrixed HEU sample

Two scintillation vials, kindly provided by the PNNL team, were received in the LLNL radiochemistry building on June 10, 2024; one containing approximately 2 mL dissolved thermally-irradiated HEU, and the other containing dried salt from irradiated seawater. A quick, semiquantitative screening count of the salt showed that the activation product activities were very low, with the highest activity being ~1 Bq 24 Na. The dissolved HEU solution was transferred to a Prindle vial (LLNL standard counting geometry) and weighed. Approximately 2 mL 3 M HNO 3 was added so that the solution completely covered the bottom of the vial and Gamanal software would be able to accurately generate an efficiency curve. This sample, called “PNNLFP24” is the irradiated HEU solution received, gravimetrically diluted by a factor of 1.7356 ± 0.0003, and was sent for quick gamma counting prior to further modification. Meanwhile the salt was quantitatively transferred to a 250 mL polyethylene bottle and dissolved in 160 mL 3 M HNO 3 . After counting, 50 µL PNNLFP24 was aliquoted for Resonance Ionization Mass Spectrometry (RIMS) analysis, and then 10.0 mL of the salt solution (6.03% of the total salt, gravimetrically) was added to the remaining PNNLFP24 solution to make “PNNLFPSW24”. After weighing, two 100 µL aliquots were removed for RIMS and DES, and 3 mL was aliquoted for microfluidic chemistry. The remaining “PNNLFPSW24” solution was weighed and proceeded for singles and coincidence counting on the MCBOS system.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Sample processing approach for detection of ricin in surface samples

With several ricin contamination incidents reported over the past decade, rapid and accurate methods are needed for environmental sample analysis, especially after decontamination. A sample processing method was developed for common surface sampling devices to improve the limit of detection and avoid false negative/positive results for ricin analysis. Potential assay interferents from the sample matrix (bleach residue, sample material, wetting buffer), including reference dust, were tested using a Time-Resolved Fluorescence (TRF) immunoassay. Test results suggested that the sample matrix did not cause the elevated background fluorescence sometimes observed when analyzing post-bleach decontamination samples from ricin incidents. Furthermore, sample particulates (80 mg/mL Arizona Test Dust) did not enhance background fluorescence or interfere with ricin detection by TRF. These results suggested that high background fluorescence in this immunoassay could be due to labeled antibody quality and/or quantity issues. Centrifugal ultrafiltration devices were evaluated for ricin concentration as a part of sample processing. Up to 30-fold concentration of ricin was observed by the devices, which serve to remove soluble interferents and could function as the front-end sample processing step to other ricin analytical methods. Here, the procedure has the potential to be used with a broader range of environmental sample types and with other potential interferences and to be followed by other ricin analytical methods, although additional verification studies would be required.

54 ENVIRONMENTAL SCIENCES↗

Uncertainty Measurement for Trace Element Analysis of Uranium and Plutonium Samples by Inductively Coupled Plasma-Atomic Emission Spectrometry (ICP-AES) and Inductively Coupled Plasma-Mass Spectrometry (ICP-MS)

The measurement uncertainty estimation associated with trace element analysis of impurities in U and Pu was evaluated using the Guide to the Expression of Uncertainty Measurement (GUM). I this evaluation the uncertainty sources were identified and standard uncertainties for the components were categorized as either Type A or B. The combined standard uncertainty was calculated and a coverage factor k = 2 was applied to obtain the expanded uncertainty, U. The ICP-AES and ICP-MS methods used were developed for the multi-element analysis of U and Pu samples. A typical analytical run consists of standards, process blanks, samples, matrix spiked samples, post digestion spiked samples and independent calibration verification standards. The uncertainty estimation was performed on U and Pu samples that have been analyzed previously as part of the U and Pu Sample Exchange Programs. Control chart results and data from the U and Pu metal exchange programs were combined with the GUM into a concentration dependent estimate of the expanded uncertainty. Comparison of trace element uncertainties obtained using this model was compared to those obtained for trace element results as part of the Exchange programs. This process was completed for all trace elements that were determined to be above the detection limit for the U and Pu samples.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Luminescence relaxation dynamics for planar and rolled-up CdSe nanocrystals in a photonic-crystal matrix

Samples of inverted photonic-crystal films, containing planar and rolled-up (in the form of scrolls) CdSe nanocrystals, are studied. The transmission spectra of these structures are recorded. These spectra (along with the change in colour) confirm the incorporation of nanocrystals into the films. The photoluminescence decay dynamics is investigated. It is shown that the photonic-crystal matrix affects significantly the luminescence kinetics of nanostructures. The differences in the decay curves measured for nanocrystals in a photonic-crystal matrix and for their ensemble on a glass substrate are explained by the influence of the photonic-crystal stop band and the orientational effect of crystalline matrix, which orients anisotropic nanocrystals and prevents them from aggregation. The results obtained may be important for potential applications in optoelectronic devices. (paper)

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

IRRADIATION OF ETHYLENE DILUTED IN SOLID NITROGEN WITH VACUUM ULTRAVIOLET LIGHT AND ELECTRONS: ITS IMPLICATIONS FOR THE FORMATION OF HCN AND HNC

Chemical reactions of C{sub 2}H{sub 4} dispersed in solid nitrogen at 10 K that occur upon irradiation with Lyα light at a wavelength of 121.6 nm and 500 eV electrons were investigated by measuring the infrared absorption spectra. Photolysis of the matrix samples with 121.6 nm light yielded products, including C{sub 2}H{sub 2}, CN, and isomers of C{sub 2}N{sub 2}, as well as a pair of HCN and HNC. In contrast, electron bombardment of similar matrix samples mainly resulted in the generation of N{sub 3}, C{sub 2}H{sub 2}, C{sub 2}H{sub 3}, C{sub 3}H{sub 2}, and C{sub 3}N{sup −}. Mechanisms of the reactions that occur during the photolysis and electron-radiation of the matrix samples are discussed. The results of the study provide insights into the formation of HNC and HCN, as well as nitriles, in N{sub 2}-rich ice samples containing a small proportion of C{sub 2}H{sub 4}.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Production of zirconium-88 via proton irradiation of metallic yttrium and preparation of target for neutron transmission measurements at DICER

Abstract A process for the production of tens to hundreds of GBq amounts of zirconium-88 ( 88 Zr) using proton beams on yttrium was developed. For this purpose, yttrium metal targets (≈20 g) were irradiated in a ~16 to 34 MeV proton beam at a beam current of 100–200 µA at the Los Alamos Isotope Production Facility (IPF). The 88 Zr radionuclide was produced and separated from the yttrium targets using hydroxamate resin with an elution yield of 94(5)% (1σ). Liquid DCl solution in D 2 O was selected as a suitable 88 Zr sample matrix due to the high neutron transmission of deuterium compared to hydrogen and an even distribution of 88 Zr in the sample matrix. The separated 88 Zr was dissolved in DCl and 8 µL of the obtained solution was transferred to a tungsten sample can with a 1.2 mm diameter hole using a syringe and automated filling station inside a hot cell. Neutron transmission of the obtained 88 Zr sample was measured at the Device for Indirect Capture Experiments on Radionuclides (DICER).

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Portable sample preparation and analysis system for micron and sub-micron particle characterization using light scattering and absorption spectroscopy

There is provided a method and device for remote sampling, preparation and optical interrogation of a sample using light scattering and light absorption methods. The portable device is a filtration-based device that removes interfering background particle material from the sample matrix by segregating or filtering the chosen analyte from the sample solution or matrix while allowing the interfering background particles to be pumped out of the device. The segregated analyte is then suspended in a diluent for analysis. The device is capable of calculating an initial concentration of the analyte, as well as diluting the analyte such that reliable optical measurements can be made. Suitable analytes include cells, microorganisms, bioparticles, pathogens and diseases. Sample matrixes include biological fluids such as blood and urine, as well as environmental samples including waste water.

47 OTHER INSTRUMENTATION↗

Scanning Electron Microscopy Analysis of Fuel/Matrix Interaction Layers in Highly-Irradiated U–Mo Dispersion Fuel Plates with Al and Al–Si Alloy Matrices

In order to investigate how the microstructure of fuel/matrix-interaction (FMI) layers change during irradiation, different U–7Mo dispersion fuel plates have been irradiated to high fission density and then characterized using scanning electron microscopy (SEM). Specifially, samples from irradiated U–7Mo dispersion fuel elements with pure Al, Al–2Si and AA4043 (~4.5 wt.%Si) matrices were SEM characterized using polished samples and samples that were prepared with a focused ion beam (FIB). Features not observable for the polished samples could be captured in SEM images taken of the FIB samples. For the Al matrix sample, a relatively large FMI layer develops, with enrichment of Xe at the FMI layer/Al matrix interface and evidence of debonding. Overall, a significant penetration of Si from the FMI layer into the U–7Mo fuel was observed for samples with Si in the Al matrix, which resulted in a change of the size (larger) and shape (round) of the fission-gas bubbles. Additionally, solid-fission-product phases were observed to nucleate and grow within these bubbles. These changes in the localized regions of the microstructure of the U–7Mo may contribute to changes observed in the macroscopic swelling of fuel plates with Al–Si matrices.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Embedding PbS Quantum Dots (QDs) in Pb-Halide Perovskite Matrices: QD Surface Chemistry and Antisolvent Effects on QD Dispersion and Confinement Properties

Hybrid materials of metal chalcogenide colloidal quantum dots (QDs) embedded in metal halide perovskites (MHPs) have led to composites with synergistic properties. Here, we investigate how QD size, surface chemistry, and MHP film formation methods affect the resulting optoelectronic properties of QD/MHP “dot-in-matrix” systems. We monitor the QD absorption and photoluminescence throughout synthesis, ligand exchange, and transfer into the MHP ink, and we characterize the final QD/MHP films via electron microscopy and transient absorption. In addition, we are the first to globally map how PbS QDs are distributed on the micrometer scale within these dot-in-matrix systems, using three-dimensional (3D) tomography time-of-flight secondary ion mass spectrometry. The surface chemistry imparted during synthesis directly affects the optical properties of the dot-in-matrix composites. Pb-halide passivation leads to QD/MHP dot-in-matrix samples with optical properties that are well-described by a theoretical model, based on a Type I finite-barrier heterostructure between the PbS QD and the MHP matrix. Samples without Pb-halide passivation show complicated size-dependent behavior, indicating a transition from a Type I heterostructure between the PbS QD wells and MHP barriers for small-sized QDs to PbS QDs that are electronically decoupled from the MHP matrix for larger QDs. Furthermore, the choice in perovskite antisolvent crystallization method leads to a difference in the spatial QD distribution within the perovskite matrix, differences in carrier lifetime, and photoluminescence shifts of up to 180 meV for PbS in methylammonium lead iodide. This work establishes an understanding of such emerging synergistic systems relevant for technologies such as photovoltaics, infrared emitters and detectors, and other unexplored technological applications.

92 SC - Basic Energy Sciences (BES) (SC-22)↗

Investigation of high‐level waste glass melting using X‐ray computed tomography

Abstract A method has been developed to quantitatively assess the melting behavior of simulated nuclear waste glasses in a 5‐cm‐diameter stainless steel beaker heated from the bottom. The method applies X‐ray scanning and computed tomography to build three‐dimensional volumetric data of a heat‐treated sample and performs an adaptive segmentation analysis of the volumetric data to identify morphologically distinct regions in the sample matrix and quantify the amount of material in each region based on computed tomography density. The method was applied to two different series of simulated high‐level waste glass melter feeds, and the results showed that it provides detailed images of samples at various stages of melting, including distribution of gas bubbles of varying sizes within the sample matrix, as well as a quantitative measure of how fast various waste/frit feeds melted relative to each other. The results show that the melting rate is influenced by the rate of calcine gas evolution, melt viscosity, and the presence of modifier ions in the feed.

Choi, Alexander S.↗

Analysis of cellular and extracellular DNA in fingerprints

It has been previously shown that DNA can be recovered from latent fingerprints left on various surfaces [R. A. H. van Oorschot and M. K. Jones, Nature 387, 767 (1997)]. However, the source of the DNA, extracellular versus cellular origin, is difficult to determine. If the DNA is cellular, it is believed to belong to skin cells while extracellular DNA is believed to originate from body fluids such as sweat [D. J. Daly et. al, Forensic Sci. Int. Genet. 6, 41-46 (2012); V. V. Vlassov et. al, BioEssays 29, 654-667 (2007)]. The origin of the DNA in fingerprints has implications for processing and interpretation of forensic evidence. The determination of the origin of DNA in fingerprints is further complicated by the fact that the DNA in fingerprints tends to be at a very low quantity [R. A. H. van Oorschot and M. K. Jones, Nature 387, 767 (1997)]. This study examined fingerprints from five volunteers left on sterilized glass slides and plastic pens. Three fingerprints were left on each glass slide (thumb, index, and middle fingers) while the pens were held as if one was writing with them. The DNA was collected from the objects using the wet swabbing technique (TE buffer). Following collection, the cellular and extracellular components of each sample were separated using centrifugation and an acoustofluidics system. Centrifugation is still the primary separation technique utilized in forensics laboratories, while acoustic focusing uses sound waves to focus large particles (cells) into low pressure nodes, separating them from the rest of the sample matrix. After separation, all samples were quantified using real-time quantitative PCR (qPCR). The overall trend is that there is more DNA in the extracellular fractions than cellular fractions for both centrifugation and acoustofluidic processing. Additionally, more DNA was generally collected from the pen samples than the samples left on glass slides.

47 OTHER INSTRUMENTATION↗

Smart Scattering Scanning Near-Field Optical Microscopy

Scattering scanning near-field optical microscopy (s-SNOM) provides spectroscopic imaging from molecular to quantum materials with few nanometer deep subdiffraction limited spatial resolution. However, in its conventional implementation s-SNOM is slow to effectively acquire a series of spatio-spectral images, especially with large fields of view. This problem is further exacerbated for weak resonance contrast or when using light sources with limited spectral irradiance. Indeed, the generally limited signal-to-noise ratio prevents sampling a weak signal at the Nyquist sampling rate. Here, we demonstrate how acquisition time and sampling rate can be significantly reduced by using compressed sampling, matrix completion, and adaptive random sampling, while maintaining or even enhancing the physical or chemical image content. We use fully sampled real data sets of molecular, biological, and quantum materials as ground-truth physical data and show how deep under-sampling with a corresponding reduction of acquisition time by 1 order of magnitude or more retains the core s-SNOM image information. We demonstrate that a sampling rate of up to 6× smaller than the Nyquist criterion can be applied, which would provide a 30-fold reduction in the data required under typical experimental conditions. Furthermore, our smart s-SNOM approach is generally applicable and provides systematic full spatio-spectral s-SNOM imaging with a large field of view at high spectral resolution and reduced acquisition time.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Selection and characterization of ssDNA aptamers specifically recognizing pathogenic Vibrio alginolyticus

Abstract Vibrio alginolyticus ( V. alginolyticus ) is a major opportunistic pathogen to both marine animals and humans, which has also caused heavy economic losses to mariculture. The aim of this study was to develop highly specific aptamers for V. alginolyticus . Single‐stranded DNA (ssDNA) aptamers with high binding affinity to viable V. alginolyticus were generated by Systematic Evolution of Ligands by Exponential Enrichment (SELEX) and identified by flow cytometric analysis in this study. The selected aptamers showed high specificity for V. alginolyticus and low apparent binding for other bacteria. The aptamers formed distinct stem‐loop structures, which could form the basis of aptamers’ specific binding to the target V. alginolyticus . Aptamer VA2 and VA8 showed particularly high binding affinity constant (K d ) of 14.31 ± 4.26 and 90.00 ± 13.51 nM, respectively. The aptamers produced no cytotoxic effects in vitro and in vivo. ssDNA aptamers were successfully selected against the viable bacteria pathogen V. alginolyticus by SELEX. The aptamers selected in this study could be not only applied as specific chemical molecular probes for studying V. alginolyticus pathogenesis to Trachinotus ovatus , but also developing rapid convenient diagnosis assay for V. alginolyticus infection, even when applied to the complex sample matrix, such as food and environment samples.

Yu, Qing↗

Automation of Extraction Chromatograhic and Ion Exchange Separations for Radiochemical Analysis and Monitoring

Radiochemical analysis, complete with the separation of radionuclides of interest from the sample matrix and from other interfering radionuclides, is often an essential step in the determination of the radiochemical composition of a nuclear sample or process stream. Although some radionuclides can be determined nondestructively by gamma spectroscopy, where the gamma rays penetrate significant distances in condensed media and the gamma ray energies are diagnostic for specific radionuclides, other radionuclides that may be of interest emit only alpha or beta particles. For these, samples must be taken for destructive analysis and radiochemical separations are required. For process monitoring purposes, the radiochemical separation and detection methods must be rapid so that the results will be timely. These results could be obtained by laboratory analysis or by radiochemical process analyzers operating on-line or at-site. In either case, there is a need for automated radiochemical analysis methods to provide speed, throughput, safety, and consistent analytical protocols. Classical methods of separation used during the development of nuclear technologies, namely manual precipitations, solvent extractions, and ion exchange, are slow and labor intensive. Fortunately, the convergence of digital instrumentation for preprogrammed fluid manipulation and the development of new separation materials for column-based isolation of radionuclides has enabled the development of automated radiochemical analysis methodology. The primary means for separating radionuclides in solution are liquid-liquid extraction and ion exchange. These processes are well known and have been reviewed in the past.1 Ion exchange is readily employed in column formats. Liquid-liquid extraction can also be implemented on column formats using solvent-impregnated resins as extraction chromatographic materials. The organic liquid extractant is immobilized in the pores of a microporous polymer material. Under suitable conditions, the analyte of interest partitions into the immobilized organic phase while other matrix speces and interferences are washed away in the mobile aqueous phase. After the wash step, retained analytes are rapidly released in one or more steps by changing the aqueous eluent, such that the analytes now partition back into the mobile phase. The development of solvent impregnated resins, their physical chemistry, technological applications for metal and radionuclide recovery, and analytical uses were described in detail in a previous chapter in this series by Cortina and Warshawsky. The extraction chromatographic approach is well suited for the isolation of radionuclides from complex sample matrixes in a rapid automated format. The development of automated radioanalytical methods is, in fact, closely coupled to the availability of such materials. In this review, we will focus on the application of radiochemical separations in automated fluidic formats for the analysis of alpha- and beta-emitting radionuclides.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

EMP Attachment 1: DOE-SC PNNL Site Sampling and Analysis Plan

This Sampling and Analysis Plan (SAP) is written for the radiological environmental air surveillance program for the DOE-SC PNNL Site, Richland Washington. It provides the requirements for planning sampling events, and the requirements imposed on the analytical laboratory analyzing the air samples. The actual air sampling process is in procedure EPRP-AIR-029. The rationale for analyte selection, media, and sampling site location has been vetted through the data quality objectives (DQO) process (Barnett et al. 2010). The results from the DQO process have been reviewed and approved by the Washington State Department of Health. The DQO process (Barnett et al. 2010) identified seven specific radionuclides for analysis along with the need for gross alpha and gross beta radiological analyses. The analytes are 241<\sup>Am, 243<\sup>Am, 244<\sup>Cm, 60<\sup>Co, 238<\sup>Pu, 239<\sup>Pu, and 233<\sup>U. The report also determined that air samples for particulates are the only sample matrix required for the monitoring program. These samples are collected on 47-mm glass-fiber filters.

54 ENVIRONMENTAL SCIENCES↗