Search NASA⌕ Search

SEARCH · Search NASA

Results for “measurement path”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Release path temperatures of shock-compressed tin from dynamic reflectance and radiance measurements

Dynamic reflectance and radiance measurements were conducted for tin samples shock compressed to 35 GPa and released to 15 GPa using high explosives. We determined the reflectance of the tin samples glued to lithium fluoride windows using an integrating sphere with an internal xenon flashlamp as an illumination source. The dynamic reflectance (R) was determined at near normal incidence in four spectral bands with coverage in visible and near-infrared spectra. Uncertainties in R/R{sub 0} are <2%, and uncertainties in absolute reflectance are <5%. In complementary experiments, thermal radiance from the tin/glue/lithium fluoride interface was recorded with similar shock stress and spectral coverage as the reflectance measurements. The two sets of experiments were combined to obtain the temperature history of the tin surface with an uncertainty of <2%. The stress at the interface was determined from photonic Doppler velocimetry and combined with the temperatures to obtain temperature-stress release paths for tin. We discuss the relationship between the experimental release paths and release isentropes that begin on the principal shock Hugoniot.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

ProgLIMI: Programmable LInk Metric Identification in Software-Defined Networks

In this paper, we propose the Programmable LInk Metric Identification (ProgLIMI) infrastructure for software-defined networking (SDN) networks. ProgLIMI identifies round-trip link metrics (RTLMs) from accumulated end-to-end metrics of selected measurement paths by leveraging the flexible routing control capability of SDN networks. ProgLIMI mainly solves three sub-problems: (1) monitor placement; (2) linearly independent measurement path construction; and (3) flow rule design. To reduce measurement cost, ProgLIMI tries to minimize the number of required monitors and flow rules. In this paper, we address the three sub-problems for both full and hybrid SDN networks. For full SDN networks, ProgLIMI can achieve full RTLM identification using only one monitor and two flow rules in each SDN switch. In contrast, the RTLM identification in hybrid SDN networks is more complicated due to the routing constraint of hybrid SDN networks. We first prove that the monitor placement problem in hybrid SDN networks is NP-hard. We then formulate the monitor placement and measurement path selection problem in hybrid SDN networks and propose a greedy heuristic algorithm to solve the problem efficiently. Our evaluations on both physical testbed and simulation platform reveal that ProgLIMI can accurately identify the RTLMs (delay and loss rate). Besides, ProgLIMI is also resource efficient, i.e., it only requires two flow rules in each SDN switch and a small number of monitors, and the extra probing traffic load incurred by ProgLIMI is also low.

97 MATHEMATICS AND COMPUTING↗

Standoff Detection of Chemical Plumes Using Swept-ECQCL Remote Detection Technology: Results from EMRTC Complex Terrain Dual Tracer Experiment

As part of the Complex Terrain Dual Tracer Experiments performed in support of the LYNM program, a swept-wavelength external cavity quantum cascade laser (swept-ECQCL) remote detection system was deployed to measure chemical plume propagation with high temporal resolution. The swept-ECQCL remote detection technology was initially developed at PNNL, and is now under further development at Opticslah, LLC under SBIR funding from DOE (DOE SBIR Phase I Project DE-SC0019855, Remote Detection Technologies, Program Manager Chris Ramos). The swept-ECQCL technology provides a single-frequency infrared laser source which is rapidly scanned over a large wavelength range to measure the infrared absorption of gases, liquids, or solids. Analysis of the measured infrared absorption spectrum is used to detect, identify, and quantify the chemical species which are present. While most previous laser-based techniques used small wavelength tuning ranges to measure only a few isolated spectral lines of a few species, the swept-ECQCL provides the large tuning range needed to measure multiple species simultaneously, and to detect broad absorption features from large molecules or condensed phase materials. In addition, the swept-ECQCL systems have high enough spectral resolution and sensitivity to measure narrow lines of small molecules and determine isotope ratios. The remote detection system for gas plumes is based on the swept-ECQCL technology, and consists of a swept-ECQCL source, infrared detector, control electronics, and beam transmitting and alignment optics. The remote detection system directs the infrared output of the swept-ECQCL to a target retro reflector typically located at ~10-10,000 m distance. The swept-ECQCL wavelength is varied continuously over a large wavelength range (>1000 nm) at rates up to 1000 Hz. The swept ECQCL light reflected from the remote target is collected and focused onto an infrared photodetector. By measuring the detector signal continuously as the swept-ECQCL wavelength is varied, a time-series of absorption spectra are measured for the gases along the beam line of-sight. Based on analysis and fitting of the measured absorption spectra, the time-dependent chemical concentrations of species are determined. Multiple species and mixtures can be detected simultaneously, for all species with absorption features above the sensor noise floor. The sensor output is thus a continuous, high-speed record of identified chemicals along with their concentrations and isotope ratios of interest. The high-speed operation enables low-noise operation in conditions of atmospheric turbulence and allows tracking of fluctuating concentrations in transient chemical plumes as needed for reliable remote detection applications. All components operate with minimal cooling requirements and no cryogens are needed. In addition, the output infrared light is invisible with an intensity below the maximum permissible exposure (MPE) threshold of 100 mW/cm2 for these infrared wavelengths and thus eye safe. The measurement concept for plume detection using the swept-ECQCL remote detection system is as follows. The ECQCL beam is directed toward a remote retro-reflector, which reflects the beam back to the ECQCL system where it is focused onto an infrared photodetector. The line-of-sight from the ECQCL system to the retro-reflector defines the measurement path. The detected infrared signal is recorded continuously and detects the absorption of molecular species along the measurement path. Before a plume release, the system measures absorption from atmospheric constituents, which in this LWIR band consist primarily of lines from H 2 O and CO 2 , with additional weaker absorption from N 2 O, NH 3 , and O 3 possibly contributing. The system then measures any changes in absorption due to the tracer compounds when they enter the measurement path. The shape of absorption features is used to distinguish and identify the different tracer compounds, and the strength of the absorption is used to determine the path-integrated concentration – also called the column density.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Bootstrap inversion technique for atmospheric trace gas source detection and quantification using long open-path laser measurements

Advances in natural gas extraction technology have led to increased activity in the production and transport sectors in the United States and, as a consequence, an increased need for reliable monitoring of methane leaks to the atmosphere. We present a statistical methodology in combination with an observing system for the detection and attribution of fugitive emissions of methane from distributed potential source location landscapes such as natural gas production sites. We measure long (> 500 m), integrated open-path concentrations of atmospheric methane using a dual frequency comb spectrometer and combine measurements with an atmospheric transport model to infer leak locations and strengths using a novel statistical method, the non-zero minimum bootstrap (NZMB). The new statistical method allows us to determine whether the empirical distribution of possible source strengths for a given location excludes zero. Using this information, we identify leaking source locations (i.e., natural gas wells) through rejection of the null hypothesis that the source is not leaking. The method is tested with a series of synthetic data inversions with varying measurement density and varying levels of model–data mismatch. It is also tested with field observations of (1) a non-leaking source location and (2) a source location where a controlled emission of 3.1 &times; 10 -5 kg s -1 of methane gas is released over a period of several hours. This series of synthetic data tests and outdoor field observations using a controlled methane release demonstrates the viability of the approach for the detection and sizing of very small leaks of methane across large distances (4 + km 2 in synthetic tests). The field tests demonstrate the ability to attribute small atmospheric enhancements of 17 ppb to the emitting source location against a background of combined atmospheric (e.g., background methane variability) and measurement uncertainty of 5 ppb (1 σ ), when measurements are averaged over 2 min. The results of the synthetic and field data testing show that the new observing system and statistical approach greatly decreases the incidence of false alarms (that is, wrongly identifying a well site to be leaking) compared with the same tests that do not use the NZMB approach and therefore offers increased leak detection and sizing capabilities.

03 NATURAL GAS↗

Path integral measure, constraints and ghosts for massive gravitons with a cosmological constant

For massive gravity in a de Sitter background one encounters problems of stability when the curvature is larger than the graviton mass. I analyze this situation from the path integral point of view and show that it is related to the conformal factor problem of Euclidean quantum (massless) gravity. When a constraint for massive gravity is incorporated and the proper treatment of the path integral measure is taken into account one finds that, for particular choices of the DeWitt metric on the space of metrics (in fact, the same choices as in the massless case), one obtains the opposite bound on the graviton mass.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Water equivalent path length measurement in proton radiotherapy using time resolved diode dosimetry

Purpose: To verify water equivalent path length (WEPL) before treatment in proton radiotherapy using time resolved in vivo diode dosimetry. Methods: Using a passively scattered range modulated proton beam, the output of a diode driving a fast current-to-voltage amplifier is recorded at a number of depths in a water tank. At each depth, a burst of overlapping single proton pulses is observed. The rms duration of the burst is computed and the resulting data set is fitted with a cubic polynomial. Results: When the diode is subsequently set to an arbitrary depth and the polynomial is used as a calibration curve, the ''unknown'' depth is determined within 0.3 mm rms. Conclusions: A diode or a diode array, placed (for instance) in the rectum in conjunction with a rectal balloon, can potentially determine the WEPL at that point, just prior to treatment, with submillimeter accuracy, allowing the beam energy to be adjusted. The associated unwanted dose is about 0.2% of a typical single fraction treatment dose.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Iron X-ray Transmission at Temperature Near 150 eV Using the National Ignition Facility: First Measurements and Paths to Uncertainty Reduction

Discrepancies exist between theoretical and experimental opacity data for iron, at temperatures 180–195 eV and electron densities near 3 × 1022/cm3, relevant to the solar radiative-convective boundary. Another discrepancy, between theory and helioseismic measurements of the boundary’s location, would be ameliorated if the experimental opacity is correct. To address these issues, this paper details the first results from new experiments under development at the National Ignition Facility (NIF), using a different method to replicate the prior experimental conditions. In the NIF experiments, 64 laser beams indirectly heat a plastic-tamped rectangular iron-magnesium sample inside a gold cavity. Another 64 beams implode a spherical plastic shell to produce a continuum X-ray flash which backlights the hot sample. An X-ray spectrometer records the transmitted X-rays, the unattenuated X-rays passing around the sample, and the sample’s self-emission. From these data, X-ray transmission spectra are inferred, showing Mg K-shell and Fe L-shell X-ray transitions from plasma at a temperature of ~150 eV and electron density of ~8 × 1021/cm3. These conditions are similar to prior Z measurements which agree better with theory. The NIF transmission data show statistical uncertainties of 2–10%, but various systematic uncertainties must be addressed before pursuing quantitative comparisons. The paths to reduction of the largest uncertainties are discussed. Once the uncertainty is reduced, future NIF experiments will probe higher temperatures (170–200 eV) to address the ongoing disagreement between theory and Z data.

36 MATERIALS SCIENCE↗

Two-path transport measurements with bias dependence on a triple quantum dot

We present transport measurements on a lateral triple quantum dot with a star-like geometry and one lead attached to each dot. The system is studied in a regime close to established quadruple points, where all three dots are in resonance. The specific sample structure allows us to apply two different bias voltages to the two source leads and thus to study the influence between the paths with serial double dots.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

A volumetric approach to path-length measurements is essential when treating radiotherapy with modulated beams

The established dosimetric benefits of intensity-modulated radiation therapy (IMRT) and volumetric-modulated arc therapy have lead to their increased use in prostate radiotherapy. Complimenting these techniques, volumetric image guidance has supported increased positional accuracy. In addition, 3-dimensional image guidance has also allowed for assessment of potential dosimetric variation that can be attributed to a deformation of either internal or external structures, such as rectal distension or body contour. Compounding these issues is the variation of tissue density through which the new field position passes and also the variation of dose across a modulated beam. Despite the growing level of interest in this area, there are only a limited number of articles that examine the effect of a variation in beam path length, particularly across a modulated field. IMRT and volumetric-modulated radiation therapy (VMAT) fields are dynamic in nature, and the dose gradient within these fields is variable. Assessment of variation of path length away from the beam's central axis and across the entire field is vital where there is considerable variation of dose within the field, such as IMRT and VMAT. In these cases, reliance on the traditional central axis to focus skin distances is no longer appropriate. This article discusses these more subtle challenges that may have a significant clinical effect if left unrecognized and undervalued.

61 RADIATION PROTECTION AND DOSIMETRY↗

Comparison of Aromatic Hydrocarbon Measurements made by PTR-MS, DOAS and GC-FID during the MCMA 2003 Field Experiment

A comparison of aromatic hydrocarbon measurements is reported for the CENICA upersite in the district of Iztapalapa during the Mexico City Metropolitan Area field experiment in April 2003 (MCMA 2003). Data from three different measurement methods were compared: a Proton Transfer Reaction Mass Spectrometer (PTR-MS), long path measurements using a UV Differential Optical Absorption Spectrometer (DOAS), and Gas Chromatography-Flame Ionization analysis (GC-FID) of canister samples. The principle focus was on the comparison between PTR-MS and DOAS data. Lab tests established that the PTR-MS and DOAS calibrations were consistent for a suite of aromatic compounds including benzene, toluene, p-xylene, ethylbenzene, 1,2,4-trimethylbenzene, phenol and styrene. The point sampling measurements by the PTR-MS and GC-FID showed good correlations (r=0.6), and were in reasonable agreement for toluene, C₂-alkylbenzenes and C3-alkylbenzenes. The PTR-MS benzene data were consistently high, indicating interference from ethylbenzene fragmentation for the 145 Td drift field intensity used in the experiment. Correlations between the open-path data measured at 16-m height over a 860-m path length (retroreflector in 430m distance), and the point measurements collected at 37-m sampling height were best for benzene (r=0.61), and reasonably good for toluene, C2-alkylbenzenes, naphthalene, styrene, cresols and phenol (r>0.5). There was good agreement between DOAS and PTR-MS measurements of benzene after correction for the PTR-MS ethylbenzene interference. Mixing ratios easured by DOAS were on average a factor of 1.7 times greater than the PTR-MS data for toluene, C2-alkylbenzenes, naphthalene and styrene. The level of agreement for the toluene data displayed a modest dependence on wind direction, establishing that spatial gradients - horizontal, vertical, or both – in toluene mixing ratios were significant, and up to a factor of 2 despite the fact that all measurements were conducted above roof level. Our analysis highlights a potential problem in defining a VOC sampling strategy that is meaningful for the comparison with photochemical transport models: meaningful measurements require a spatial fetch that is comparable to the grid cell size of models, which is typically a few 10 km2. Long-path DOAS measurements inherently average over a larger spatial scale than point measurements. The spatial representativeness can be further increased if observations are conducted outside the surface roughness sublayer, which might require measurements at altitudes as high as 10s of metres above roof level.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Optical CT imaging of solid radiochromic dosimeters in mismatched refractive index solutions using a scanning laser and large area detector

Purpose: The practical use of the PRESAGE® solid plastic dosimeter is limited by the inconvenience of immersing it in high-viscosity oils to achieve refractive index matching for optical computed tomography (CT) scanning. The oils are slow to mix and difficult to clean from surfaces, and the dosimeter rotation can generate dynamic Schlieren inhomogeneity patterns in the reference liquid, limiting the rotational and overall scan speed. Therefore, it would be beneficial if lower-viscosity, water-based solutions with slightly unmatched refractive index could be used instead. The purpose of this work is to demonstrate the feasibility of allowing mismatched conditions when using a scanning laser system with a large acceptance angle detector. A fiducial-based ray path measurement technique is combined with an iterative CT reconstruction algorithm to reconstruct images. Methods: A water based surrounding liquid with a low viscosity was selected for imaging PRESAGE® solid dosimeters. Liquid selection was optimized to achieve as high a refractive index as possible while avoiding rotation-induced Schlieren effects. This led to a refractive index mismatch of 6% between liquid and dosimeters. Optical CT scans were performed with a fan-beam scanning-laser optical CT system with a large area detector to capture most of the refracted rays. A fiducial marker placed on the wall of a cylindrical sample occludes a given light ray twice. With knowledge of the rotation angle and the radius of the cylindrical object, the actual internal path of each ray through the dosimeter can be calculated. Scans were performed with 1024 projections of 512 data samples each, and rays were rebinned to form 512 parallel-beam projections. Reconstructions were performed on a 512 × 512 grid using 100 iterations of the SIRT iterative CT algorithm. Proof of concept was demonstrated with a uniformly attenuating solution phantom. PRESAGE® dosimeters (11 cm diameter) were irradiated with Cobalt-60 irradiator to achieve either a uniform dose or a 2-level “step-dose” pattern. Results: With 6% refractive index mismatching, a circular field of view of 85% of the diameter of a cylindrical sample can be reconstructed accurately. Reconstructed images of the test solution phantom were uniform (within 3%) inside this radius. However, the dose responses of the PRESAGE® samples were not spatially uniform, with variations of at least 5% in sensitivity. The variation appears as a “cupping” artifact with less sensitivity in the middle than at the periphery of the PRESAGE® cylinder. Polarization effects were also detected for these samples. Conclusions: The fiducial-based ray path measurement scheme, coupled with an iterative reconstruction algorithm, enabled optical CT scanning of PRESAGE® dosimeters immersed in mismatched refractive index solutions. However, improvements to PRESAGE® dose response uniformity are required.

60 APPLIED LIFE SCIENCES↗

Towards the development of a standardized testing protocol for overhead island kitchen exhaust devices: Procedures, measurements and paths forward

Cooking is one of the most important sources of airborne pollutants in the indoor environments of residential buildings. Elevated concentrations of NO 2 due to cooking have been reported widely (Garret et al. 1998; Garrett et al. 1999; Mullen et al. 2016; Ryan et al. 1988; Schwab et al. 1994; J. Spengler et al. 1994; J. D. Spengler et al. 1983; Wilson et al. 1995). Many researchers have attributed elevated particulate concentrations to cooking, and some have attributed extremely high short-term concentrations of fine particles (>300 μg/m3) and ultrafine particles (>105 μg/m3) to cooking events (Abdullahi et al. 2013; Abt et al. 2000; Afshari et al. 2005; Buonanno et al. 2009; He et al. 2004; Kearney et al. 2011; Lance A. Wallace et al. 2004; See and Balasubramanian 2008; Stieb et al. 2008; Wallace and Ott 2011; Wheeler et al. 2011; Zhang et al. 2010). Cooking is also a source of other gas-phase pollutants including carbon monoxide, formaldehyde, acrolein, and other volatile organic compounds (Garret et al. 1998; Garrett et al. 1999; Logue et al. 2013; Mullen et al. 2016; Ryan et al. 1988; Schwab et al. 1994; J. Spengler et al. 1994; J. D. Spengler et al. 1983; V. Seaman et al. 2007; Wilson et al. 1995). Lastly, cooking can be a significant source of water vapor, and the water vapor produced from cooking can eventually lead to moisture-related problems (Parrott and Emmel 2003)

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Wide-range fission chambers signal simulator - 373

Fission chambers (FC) signal simulators are a useful means to test neutron flux instrumentation channels of the reactors control and protection systems (CPS). Well-known signal simulators do not provide a secondary equipment testing in all modes of measurement. A wide range simulator that simulates a full range of FC signal changes (pulse, fluctuation, current) was designed. The simulator takes into account the statistical nature of neutrons detection in the FC, including the shape of the pulse and the spectrum of the pulse amplitude distribution. The simulator uses the principle of mathematical simulation of the fission chambers signal with realtime calculations using the FPGA. The wide-range simulator reproduces a FC signal in the range of ten orders without switching ranges or playback modes while ensuring very good linearity. It allows to generate both static and dynamic test signals such as: stair-step, linearly and exponential varying signals, exponential varying signals with a linearly changing period or a signal change simulating the response of the nuclear reactor power to a given reactivity response. Continuity of reproduced signals and the ability to playback dynamic effects makes it possible the simulator using to check the algorithms of cross-linking of measuring paths, reactivity and period measuring tools and to monitor the operation of interlocking and alarm CPS functions. This article discusses the simulator's software and hardware, its features and specifications, user interface and example of the simulator using to check the neutron flux monitoring channels. (authors)

22 GENERAL STUDIES OF NUCLEAR REACTORS↗

Simultaneous measurement of surface velocity and plasma density with interferometric velocimetry

The apparent velocity measured by an interferometric surface velocimeter is a function of both the surface velocity and the time derivative of the refractive index along the measurement path. We employed this dual sensitivity to simultaneously measure km/s surface velocities and 10 18 cm -3 average plasma densities with combined VISAR (velocity interferometer system for any reflector) and PDV (photonic Doppler velocimetry) measurements in experiments performed on the Z Pulsed Power Facility. We detail the governing equations, associated assumptions, and analysis specifics and show that the surface velocity can be extracted without knowledge of the specific plasma density profile.

47 OTHER INSTRUMENTATION↗

Path description of coordinate-space amplitudes

We develop a coordinate version of light-cone-ordered perturbation theory, for general time-ordered products of fields, by carrying out integrals over one light-cone coordinate for each interaction vertex. The resulting expressions depend on the lengths of paths, measured in the same light-cone coordinate. Each path is associated with a denominator equal to a “light-cone deficit,” analogous to the “energy deficits” of momentum-space time- or light-cone-ordered perturbation theory. In effect, the role played by intermediate states in momentum space is played by paths between external fields in coordinate space. We derive a class of identities satisfied by coordinate diagrams, from which their imaginary parts can be derived. Using scalar QED as an example, we show how the eikonal approximation arises naturally when the external points in a Green function approach the light cone, and we give applications to products of Wilson lines. Although much of our discussion is directed at massless fields in four dimensions, we extend the formalism to massive fields and dimensional regularization.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗