The Practical Implementation of Non-Contacting Laser Strain Measurements Systems

Measurement of stress and strain in rotating turbomachinery is critical to many industries. The search for a non-contacting, non-interfering, non-degrading measurement system is on going and extensive. While several methods seem promising in theory, implementation has proven troublesome. This work uncovers and quantifies these implementation issues in the context of a laser measurement system. Both a Laser Doppler Velocimeter system and a displacement laser system are utilized. It is found that the key issues are signal to noise ratio, rigid body compensation, measurement location, and conversion of intermittent measurements to a continuous signal. Accounting for these factors leads to successful measurements. These results should lead to better ideas and more practical solutions to the non-contacting, non-degrading, non-interfering strain measurement system problem.

Yunis, Isam↗

Advanced optical measuring systems for measuring the properties of fluids and structures

Four advanced optical models are reviewed for the measurement of visualization of flow and structural properties. Double-exposure, diffuse-illumination, holographic interferometry can be used for three-dimensional flow visualization. When this method is combined with optical heterodyning, precise measurements of structural displacements or fluid density are possible. Time-average holography is well known as a method for displaying vibrational mode shapes, but it also can be used for flow visualization and flow measurements. Deflectometry is used to measure or visualize the deflection of light rays from collimation. Said deflection occurs because of refraction in a fluid or because of reflection from a tilted surface. The moire technique for deflectometry, when combined with optical heterodyning, permits very precise measurements of these quantities. The rainbow schlieren method of deflectometry allows varying deflection angles to be encoded with colors for visualization.

Decker, A. J.↗

Development of a surface panel measurement system

Reflector measurement systems are studied in support of the reshaping of the 34 meter antenna at Goldstone. The requirements for measurement systems are presented. A survey is made of the surface errors of existing antennas. Reflector measurement systems are divided into three categories and representative examples of each category are illustrated and discussed. Parametric error analyses are made of selected optical systems. The existing measurement method using a theodolite at the vertex is retained. A method using a theodolite on the RF cone is a possible variant.

Jones, D. L.↗

The Earth Observing System's Space Measurement System

The EOS Space Measurement System (SMS) is intended to provide global earth science data from a low-altitude orbit on a long-term, sustained basis. The SMS consists of a series of small and intermediate spacecraft carrying a diverse set of scientific instruments. The instruments include optical, IR, and microwave sensors that provide detailed imagtes of the earth's surface; tropospheric and stratospheric sounders that provide vertical profiles of parameters such as temperature, trace gas concentration, and humdity; and accurate positioning instruments.

Scolese, Christopher J.↗

Video-Camera-Based Position-Measuring System

A prototype optoelectronic system measures the three-dimensional relative coordinates of objects of interest or of targets affixed to objects of interest in a workspace. The system includes a charge-coupled-device video camera mounted in a known position and orientation in the workspace, a frame grabber, and a personal computer running image-data-processing software. Relative to conventional optical surveying equipment, this system can be built and operated at much lower cost; however, it is less accurate. It is also much easier to operate than are conventional instrumentation systems. In addition, there is no need to establish a coordinate system through cooperative action by a team of surveyors. The system operates in real time at around 30 frames per second (limited mostly by the frame rate of the camera). It continuously tracks targets as long as they remain in the field of the camera. In this respect, it emulates more expensive, elaborate laser tracking equipment that costs of the order of 100 times as much. Unlike laser tracking equipment, this system does not pose a hazard of laser exposure. Images acquired by the camera are digitized and processed to extract all valid targets in the field of view. The three-dimensional coordinates (x, y, and z) of each target are computed from the pixel coordinates of the targets in the images to accuracy of the order of millimeters over distances of the orders of meters. The system was originally intended specifically for real-time position measurement of payload transfers from payload canisters into the payload bay of the Space Shuttle Orbiters (see Figure 1). The system may be easily adapted to other applications that involve similar coordinate-measuring requirements. Examples of such applications include manufacturing, construction, preliminary approximate land surveying, and aerial surveying. For some applications with rectangular symmetry, it is feasible and desirable to attach a target composed of black and white squares to an object of interest (see Figure 2). For other situations, where circular symmetry is more desirable, circular targets also can be created. Such a target can readily be generated and modified by use of commercially available software and printed by use of a standard office printer. All three relative coordinates (x, y, and z) of each target can be determined by processing the video image of the target. Because of the unique design of corresponding image-processing filters and targets, the vision-based position- measurement system is extremely robust and tolerant of widely varying fields of view, lighting conditions, and varying background imagery.

Lane, John↗

Contour measurement system

A measurement system for measuring the departures from a straight line of discrete track sections of a track along a coal face in a mine employing a vehicle having a pair of spaced wheel assemblies which align with the track is presented. A reference arm pivotally connects between the wheel assemblies, and there is indicating means for measuring the angle of pivot between the arm and each of the wheel assemblies. The length of the device is less than the length of a track section, and thus when one of the wheel assemblies is on one track section and one is on an adjoining track section, the sum of the indicated angles will be indicative of the angle between track sections. Thus, from the length of a track section and angle, the departure of each track section from the line may be calculated.

Currie, J. R.↗

Laser System Measures Two-Dimensional Strain

Principal strains on surface of hot specimen determined at temperatures up to 750 degrees C by use of noncontact optical method based on work of I. Yamaguchi. Strains deduced from measured shifts in laser speckle patterns reflected from specimen. No preparation of surface required. Optical strain-measuring system includes rotatable assembly to enable measurement of strain in any desired direction along surface of specimen.

Lant, Christian T.↗

High-temperature capacitive strain measurement system

Capacitive strain gage and signal conditioning system measures stress-induced strain and cancels thermal expansion strain at temperatures to 1,500 F (815 C). Gage does not significantly restrain or reinforce specimen.

Wilson, E. J.↗

Television-and-Laser Range-Measuring System

Triangulation system measures angle between two lines of sight to point on object, determining distance to object. Amenable to automation. Includes automatically aimed rotatable mirrors and laser beam to define one of lines of sight. Adjusts automatically to bring two lines of sight into convergence at common point on object.

Russell, J. Kevin↗

Circularity-Measuring System

Shape gauge and associated computer constitute system measuring deviations of large cylinders from roundness. Shaped and held somewhat like crossbow, measures relative locations of three points on surface of large, round object. By making connected series of measurements around periphery technician using gauge determines deviation of object from perfect circularity. Used to measure straightness, roundness, or complicated shapes of such large geometrical objects as surfaces of aircraft and hulls of ships.

WHIPPO. WALTER B.↗

Measurement system

A measurement system is described for providing an indication of a varying physical quantity represented by or converted to a variable frequency signal. Timing pulses are obtained marking the duration of a fixed number, or set, of cycles of the sampled signal and these timing pulses are employed to control the period of counting of cycles of a higher fixed and known frequency source. The counts of cycles obtained from the fixed frequency source provide a precise measurement of the average frequency of each set of cycles sampled, and thus successive discrete values of the quantity being measured. The frequency of the known frequency source is made such that each measurement is presented as a direct digital representation of the quantity measured.

Turner, J. W.↗

Space Acceleration Measurement Systems

The Space Acceleration Measurement Systems (SAMS) Project develops and deploys the measurement systems for the Acceleration Measurement Program (AMP). At this time there are two types of measurement systems available, quasi-steady and vibratory. Orbital Acceleration Research Experiment (OARE) and Microgravity Acceleration Measurement System (MAMS) are the current quasi-steady systems available. OARE has flown numerous times supporting STS missions. MAMS has been delivered to Kennedy Space Center (KSC) for its deployment on the International Space Station (ISS). Vibratory measurements have been made and will be made by the Space Acceleration Measurement System (SAMS-I) Generation I, Space Acceleration Measurement System Generation II (SAMS-II), and Space Acceleration Measurement System Free Flyer or Generation III (SAMS-FF). SAMS-I supported 21 STS missions and has been retired. SAMS-II will be delivered to KSC to support ISS-6A launch (currently April 19, 2001). SAMS-FF has replaced SAMS-I in support of STS missions and has been deployed on sounding rockets, the KC-135 and ground facilities. SAMS-FF hardware shall be deployed on ISS in the future to provide a more compact solution.

Foster, William↗

Mass properties measurement system: Dynamics and statics measurements

This report presents and interprets experimental data obtained from the Mass Properties Measurement System (MPMS). Statics measurements yield the center-of-gravity of an unknown mass and dynamics measurements yield its inertia matrix. Observations of the MPMS performance has lead us to specific design criteria and an understanding of MPMS limitations.

Doty, Keith L.↗

Detailed Uncertainty Analysis of the ZEM-3 Measurement System

The measurement of Seebeck coefficient and electrical resistivity are critical to the investigation of all thermoelectric systems. Therefore, it stands that the measurement uncertainty must be well understood to report ZT values which are accurate and trustworthy. A detailed uncertainty analysis of the ZEM-3 measurement system has been performed. The uncertainty analysis calculates error in the electrical resistivity measurement as a result of sample geometry tolerance, probe geometry tolerance, statistical error, and multi-meter uncertainty. The uncertainty on Seebeck coefficient includes probe wire correction factors, statistical error, multi-meter uncertainty, and most importantly the cold-finger effect. The cold-finger effect plagues all potentiometric (four-probe) Seebeck measurement systems, as heat parasitically transfers through thermocouple probes. The effect leads to an asymmetric over-estimation of the Seebeck coefficient. A thermal finite element analysis allows for quantification of the phenomenon, and provides an estimate on the uncertainty of the Seebeck coefficient. The thermoelectric power factor has been found to have an uncertainty of +9-14 at high temperature and 9 near room temperature.

Seebeck effect↗

Performance of the Rotor Systems Research Aircraft calibrated rotor loads measurement system

The compound Rotor Systems Research Aircraft (RSRA) is designed to make high accuracy, simultaneous measurements of all rotor forces and moments in flight. Physical calibration of the rotor force- and moment-measurement system when installed in the aircraft is required to account for any errors and to ensure that measurement system accuracy is traceable to the National Bureau of Standards. The first static calibration and associated analysis has been completed with good results. Hysteresis was a potential cause of static calibration errors, but was found to be negligible in flight, and analytical methods have been devised to eliminate its effects on calibration data. Flight tests confirmed that the calibrated rotor loads measurement system performs as expected in flight, and that it can dependably make direct measurements of fuselage vertical drag in hover.

Acree, C. W., Jr.↗

A practical approach to determining the uncertainty of a pressure measurement system

The pressure measurement systems located at three propulsion component test stands at the Marshall Space Flight Center (MSFC) were evaluated for their specific measurement uncertainty levels. An elemental error source evaluation was performed to provide an analytical estimate of uncertainty. Applied loads tests were also conducted at the different MSFC test sites to derive an empirical estimate of uncertainty for the measurement system process. The analytical results are compared to those obtained empirically. The data from MFSC was also compared to data reported from other comparable test facilities. Methods for acquiring and processing the data from calibration, acquisition, and reduction error sources are also addressed.

Fish, James E.↗

Computer Generated Hologram System for Wavefront Measurement System Calibration

Computer Generated Holograms (CGHs) have been used for some time to calibrate interferometers that require nulling optics. A typical scenario is the testing of aspheric surfaces with an interferometer placed near the paraxial center of curvature. Existing CGH technology suffers from a reduced capacity to calibrate middle and high spatial frequencies. The root cause of this shortcoming is as follows: the CGH is not placed at an image conjugate of the asphere due to limitations imposed by the geometry of the test and the allowable size of the CGH. This innovation provides a calibration system where the imaging properties in calibration can be made comparable to the test configuration. Thus, if the test is designed to have good imaging properties, then middle and high spatial frequency errors in the test system can be well calibrated. The improved imaging properties are provided by a rudimentary auxiliary optic as part of the calibration system. The auxiliary optic is simple to characterize and align to the CGH. Use of the auxiliary optic also reduces the size of the CGH required for calibration and the density of the lines required for the CGH. The resulting CGH is less expensive than the existing technology and has reduced write error and alignment error sensitivities. This CGH system is suitable for any kind of calibration using an interferometer when high spatial resolution is required. It is especially well suited for tests that include segmented optical components or large apertures.

Olczak, Gene↗