Gamma-based nuclear fusion measurements at inertial confinement fusion facilities

Experiments performed on an inertial confinement fusion (ICF) platform offer a unique opportunity to study nuclear reactions, including reaction branches that are useful for diagnostic applications in ICF experiments as well as several that are relevant to nuclear astrophysics. In contrast to beam-accelerator experiments, experiments performed on an ICF platform occur over a short time scale and produce a plasma environment with physical parameters that are directly relevant to big bang and/or stellar nucleosynthesis. Several reactions of interest, such as D(T,γ) 5 He, H(D,γ) 3 He, H(T,γ) 4 He, and T( 3 He,γ) 6 Li produce high-energy gamma rays. S factors or branching ratios for these four reactions have recently been studied using various temporally-resolved Cherenkov detectors at the Omega laser facility. This work describes these detectors as well as the current standard technique for performing these measurements. Recent results for reactions D(T,γ) 5 He, H(D,γ) 3 He, H(T,γ) 4 He, and T( 3 He,γ) 6 Li are reviewed and compared to accelerator-based measurements. Limitations associated with implosion experiments and use of the current standard gamma detectors are discussed. A basic design for a gamma spectrometer for use at ICF facilities is briefly outlined.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Deuterium-tritium fusion γ -ray spectrum at MeV energies with application to reaction-in-flight inertial confinement fusion measurements

In inertial confinement fusion implosions, tertiary reaction-in-flight processes create deuterium-tritium fusion reactions [ T ( d , n ) 4 He ] with an incident particle moving at MeV energies instead of the thermonuclear keV temperatures. Additional relativistic kinematic treatments were added to a nuclear resonance code, , and resulting calculations showed an upshifting of the deuterium-tritium fusion γ -ray pathway [ T ( d , γ ) 5 He ] for MeV interactions. Using the calculated spectra, a representative reaction-in-flight γ -ray emission for ICF implosions was estimated. Published by the American Physical Society 2024

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Measuring fusion excitation functions with RIBs: A thorough analysis of the stacked target technique and the related problems

The use of the stacked target technique to measure fusion cross-sections of reactions induced by low intensity radioactive beams offers considerable advantages since several reaction energies may be simultaneously measured. The main disadvantage of the method is the degradation of the beam quality as it passes through the stack due to statistical nature of energy loss processes and any non-uniformity of the stacked targets. This degradation can lead to ambiguities of associating effective beam energies to reaction product yields for the targets within the stack. A detailed investigation of these ambiguities has been performed and some of the obtained results are presented.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Discrepancy between estimated and measured fusion product rates on $\mathrm{MAST}$ using $\mathrm{TRANSP/NUBEAM}$

Here experimental evidence is presented of a discrepancy between the predicted and measured D–D fusion product rates on MAST. Both the neutron and proton production rates, measured independently with a neutron camera and charged fusion product detector array, are approximately 40% lower than those predicted by TRANSP/NUBEAM codes. This deficit is scenario independent and cannot be explained by uncertainties in the typical plasma parameters suspected for such discrepancies, such as electron temperature, the plasma effective charge and the injected neutral beam power. Instead, a possible explanation is an overestimate of the neutron emissivity due to the guiding centre approximation used in NUBEAM to model the fast ion orbits.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Using Co-Moving Collisions in a Gear-Changing System to Measure Fusion Cross Sections

In this work we look at a pos­si­ble use for a sys­tem that col­lides beams mov­ing in the same di­rec­tion using a gear-chang­ing syn­chro­niza­tion method as a means of mea­sur­ing low en­ergy phe­nom­ena, such as fu­sion cross sec­tions. De­pend­ing on the en­er­gies used this process will allow for in­ter­ac­tions for any de­sired charge state of the tar­get nu­clei. Ear­lier con­cepts for low en­ergy in­ter­ac­tions to study fo­cused on beams cross­ing at an angle to give the low en­ergy in­ter­ac­tions, as well as gen­eral in­ves­ti­ga­tions of co­mov­ing col­li­sions. This pro­posal would use gear-chang­ing, a method in­volv­ing two dif­fer­ent har­monic num­bers of bunches in each col­lider ring, to have the same types of col­li­sions, with a lu­mi­nos­ity equal that of a head-on ma­chine. In this work we de­tail the de­sign con­sid­er­a­tions for such a ma­chine, lever­ag­ing ex­per­i­men­tal ex­pe­ri­ence with a co-mov­ing, gear-chang­ing sys­tem.

Nissen, E. A.↗

GNSS Ephemeris with Graceful Degradation and Measurement Fusion

A method for providing an extended propagation ephemeris model for a satellite in Earth orbit, the method includes obtaining a satellite's orbital position over a first period of time, applying a least square estimation filter to determine coefficients defining osculating Keplarian orbital elements and harmonic perturbation parameters associated with a coordinate system defining an extended propagation ephemeris model that can be used to estimate the satellite's position during the first period, wherein the osculating Keplarian orbital elements include semi-major axis of the satellite (a), eccentricity of the satellite (e), inclination of the satellite (i), right ascension of ascending node of the satellite (.OMEGA.), true anomaly (.theta.*), and argument of periapsis (.omega.), applying the least square estimation filter to determine a dominant frequency of the true anomaly, and applying a Fourier transform to determine dominant frequencies of the harmonic perturbation parameters.

Garrison, James Levi↗

Fusion-neutron measurements for magnetized liner inertial fusion experiments on the Z accelerator

Several magnetized liner inertial fusion (MagLIF) experiments have been conducted on the Z accelerator at Sandia National Laboratories since late 2013. Measurements of the primary DD (2.45 MeV) neutrons for these experiments suggest that the neutron production is thermonuclear. Primary DD yields up to 3e12 with ion temperatures ~2-3 keV have been achieved. Measurements of the secondary DT (14 MeV) neutrons indicate that the fuel is significantly magnetized. Measurements of down-scattered neutrons from the beryllium liner suggest ρR liner ~ 1g/cm 2 . Neutron bang times, estimated from neutron time-of-flight (nTOF) measurements, coincide with peak x-ray production. Furthermore, plans to improve and expand the Z neutron diagnostic suite include neutron burn-history diagnostics, increased sensitivity and higher precision nTOF detectors, and neutron recoil-based yield and spectral measurements.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Generalized Measurable Ignition Criterion for Inertial Confinement Fusion

A multidimensional measurable criterion for central ignition of inertial-confinement-fusion capsules is derived. The criterion accounts for the effects of implosion nonuniformities and depends on three measurable parameters: the neutron-averaged total areal density (pRn^tot), the ion temperature (Tn), and the yield over clean (YOC = ratio of the measured neutron yield to the predicted one-dimensional yield). The YOC measures the implosion uniformity. The criterion can be approximated by chi = (pRn^tot)^0.8 x (Tn/4.7)^1.7 YOC^u > 1 (where pR is in g cm^-2, T in keV, and u ~~0.4–0.5) and can be used to assess the performance of cryogenic implosions on the NIF and OMEGA. Cryogenic implosions on OMEGA have achieved chi ~ 0.02–0.03.

Chang, P Y↗

Fusion Power measurement at ITER

Nuclear fusion research aims to provide energy for the future in a sustainable way and the ITER project scope is to demonstrate the feasibility of nuclear fusion energy. ITER is a nuclear experimental reactor based on a large scale fusion plasma (tokamak type) device generating Deuterium - Tritium (DT) fusion reactions with emission of 14 MeV neutrons producing up to 700 MW fusion power. The measurement of fusion power, i.e. total neutron emissivity, will play an important role for achieving ITER goals, in particular the fusion gain factor Q related to the reactor performance. Particular attention is given also to the development of the neutron calibration strategy whose main scope is to achieve the required accuracy of 10% for the measurement of fusion power. Neutron Flux Monitors located in diagnostic ports and inside the vacuum vessel will measure ITER total neutron emissivity, expected to range from 1014 n/s in Deuterium - Deuterium (DD) plasmas up to almost 10{sup 21} n/s in DT plasmas. The neutron detection systems as well all other ITER diagnostics have to withstand high nuclear radiation and electromagnetic fields as well ultrahigh vacuum and thermal loads. (authors)

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

First fusion proton measurements in TEXTOR plasmas using activation technique

MeV particle loss measurements from fusion plasmas, in particular alpha particles, remain difficult in large fusion devices and further R and D is needed for ITER. This paper describes the first attempt to measure 3 MeV escaping fusion protons emitted from TEXTOR tokamak plasmas using activation technique. This technique was successfully demonstrated, initially, in 2006 on the JET tokamak. An ion camera equipped with a collimator and several types of activation detectors was installed inside the TEXTOR vacuum vessel to perform these measurements. After irradiation, the detectors were analyzed using ultra low level gamma-ray spectrometry at the HADES underground laboratory. 3 MeV escaping fusion protons were detected in larger number -{approx}6 times more - compared to earlier measurements using this technique on JET. Another major progress was the reduction of the cooling time by a factor of 50, which made possible to detect radionuclides with half-life of less than 90 min.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Measurements of the Differential Cross Sections for the Elastic n-{sup 3}H and n-{sup 2}H Scattering at 14.1 MeV by Using an Inertial Confinement Fusion Facility

For the first time the differential cross section for the elastic neutron-triton (n-{sup 3}H) and neutron-deuteron (n-{sup 2}H) scattering at 14.1 MeV has been measured by using an inertial confinement fusion facility. In these experiments, which were carried out by simultaneously measuring elastically scattered {sup 3}H and {sup 2}H ions from a deuterium-tritium gas-filled inertial confinement fusion capsule implosion, the differential cross section for the elastic n-{sup 3}H scattering was obtained with significantly higher accuracy than achieved in previous accelerator experiments. The results compare well with calculations that combine the resonating-group method with an ab initio no-core shell model, which demonstrate that recent advances in ab initio theory can provide an accurate description of light-ion reactions.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Technique for an improved and time-resolved carbon areal density measurement with a single channel diagnostic for inertial confinement fusion

Measurement of the areal density and velocity of the carbon ablator shell during peak burn in inertial confinement fusion give powerful information on the state of the ablator and where in the trajectory of implosion it reaches peak burn. Detailed comparison of the absolute densities and velocities of the carbon in implosions has been prevented by the limited ability to resolve shot-to-shot variation within a shot series or within a campaign. Here, a new approach using a single, ultra fast (~10 ps) gamma ray channel can massively reduce uncertainties and will provide insights on improvements to target and drive variables. Small improvements in these experimental design parameters may result in much greater yields.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Three-dimensional diagnostics and measurements of inertial confinement fusion plasmas

Recent inertial confinement fusion measurements have highlighted the importance of 3D asymmetry effects on implosion performance. One prominent example is the bulk drift velocity of the deuterium–tritium plasma undergoing fusion (“hotspot”), v HS . Upgrades to the National Ignition Facility neutron time-of-flight diagnostics now provide v HS to better than 1 part in 10 4 and enable cross correlations with other measurements. Here we present the impact of v HS on the neutron yield, downscatter ratio, apparent ion temperature, electron temperature, and 2D x-ray emission. The necessary improvements to diagnostic suites to take these measurements are also detailed. The benefits of using cross-diagnostic analysis to test hotspot models and theory are discussed, and cross-shot trends are shown.

47 OTHER INSTRUMENTATION↗

Total fusion yield measurements using deuterium–tritium gamma rays

The deuterium–tritium (DT) fusion reaction, D ( T , γ ) 5 He , has a rare (4.2 × 10 – 5 ) branching ratio that releases a ~16 MeV gamma ray instead of the more common 14.1 MeV fusion neutron. These fusion gamma rays can be used as a complementary source of measuring the net fusion yield of experiments. Fusion gamma rays have the advantage of having negligible Doppler broadening, being isotropic and less down-scattered compared to fusion neutrons. At the National Ignition Facility, we measured the DT fusion gamma rays by the Gamma Reaction History diagnostic that thresholds to only measure >10 MeV gamma rays. After removing a ~12% contribution from neutron capture interactions in deuterium, D ( n , γ ) T , and carbon, 12 C ( n , γ ) 13 C , the deviation between GRH measurements and neutron-based yield measurements has been reduced to 10%. Further improvements are needed for detailed physics comparison.