Search NASASearch

SEARCH · Search NASA

Results for “measures”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Over three decades, and counting, of near-surface turbulent flux measurements from the Atmospheric Radiation Measurement (ARM) user facility

Processes mediating the coupling of terrestrial, aquatic, biospheric, and atmospheric systems influence weather, climate, and ecosystem dynamics via transfer of energy, momentum, water, and carbon (or other species). These exchange processes are quantified by measurements of near-surface turbulent fluxes. Understanding processes at these interfaces provides insight toward understanding and predicting current and future states within the Earth system. The Atmospheric Radiation Measurement (ARM) user facility has been conducting measurements of near-surface turbulent fluxes since the early 1990s at long-term fixed locations and shorter-term mobile deployments across the Earth. ARM has utilized two established methods for conducting these measurements: energy balance Bowen ratio (EBBR) and eddy covariance (EC). Primary measurements from the former include sensible and latent heat flux, while the latter also measures fluxes of momentum and carbon (primarily carbon dioxide, with methane fluxes measured at two locations to date). The EBBR systems have been deployed at 22 locations, and, to date, the EC systems have been deployed at over 50 sites, with plans for additional novel site locations in the future. Herein, the history, evolution, and key aspects of these instrument systems are documented, along with information on data quality assurance and post-processing, as well as best use practices. Additionally, three data validation experiments were recently conducted, and their key findings are summarized. Finally, ancillary datasets acquired by ARM, which can contextualize and aid interpretation of the near-surface turbulent flux measurements, are discussed. The datasets described herein include the eddy correlation flux measurement system: 30ECOR (https://doi.org/10.5439/1879993, Sullivan et al., 1997), 30QCECOR (https://doi.org/10.5439/1097546, Gaustad, 2003), ECORSF (https://doi.org/10.5439/1494128, Sullivan et al., 2019a), and associated AmeriFlux and Methane Value-Added Product, AMCMETHANE (https://doi.org/10.5439/1508268, Billesbach, 2011); the energy balance Bowen ratio system: 30EBBR (https://doi.org/10.5439/1023895, Sullivan et al., 1993) and 30BAEBBR (https://doi.org/10.5439/1027268, Gaustad and Xie, 1993); and the carbon dioxide flux measurement system: CO2FLX (https://doi.org/10.5439/1287574, https://doi.org/10.5439/1287575, https://doi.org/10.5439/1287576, Koontz et al., 2015a, b, c; https://doi.org/10.5439/1989774, https://doi.org/10.5439/1989776, https://doi.org/10.5439/1992202, Biraud and Chan, 2002a, b, c). These data can be found by searching the above data stream names at https://adc.arm.gov/discovery/#/results/ (last access: 8 September 2025).

Sullivan, Ryan C. [Argonne National Laboratory (AN

Long-term measurements of ice nucleating particles at Atmospheric Radiation Measurement (ARM) sites worldwide

Ice nucleating particles (INPs) play a critical role in cloud microphysics and precipitation formation, yet long-term, spatially extensive observational datasets remain limited. Here, we present one of the most comprehensive publicly available datasets of immersion-mode INP concentrations using a single analytical method, generated through the U.S. Department of Energy's (DOE) Atmospheric Radiation Measurement (ARM) user facility. INP filter samples have been collected across a broad range of environments – including agricultural plains, Arctic coastlines, high-elevation mountain sites, marine regions, and urban areas – via fixed observatories, mobile facility deployments, and vertically-resolved tethered balloon system operations. We describe the standardized processing and quality assurance pipeline, from filter collection and processing using the Ice Nucleation Spectrometer to final data products archived on the ARM Data Discovery portal. The dataset includes both total INP concentrations and selectively treated samples, allowing for classification of biological, organic, and inorganic INP types. It features a continuous 5-year record of INP measurements from a central U.S. site, with data collection still ongoing. Seasonal and site-specific differences in INP concentrations are illustrated through intercomparisons at −10 and −20 °C, revealing distinct regional sources and atmospheric drivers. We also outline mechanisms for researchers to access existing data, request additional sample analyses, and propose future field campaigns involving ARM INP measurements. This dataset supports a wide range of scientific applications, from observational and mechanistic studies to model development, and provides critical constraints on aerosol-cloud interactions across diverse atmospheric regimes (Creamean et al., 2024, 2020b; https://doi.org/10.5439/1770816).

Creamean, Jessie M. [Colorado State Univ., Fort Co

Quasiprobabilistic Readout Correction of Midcircuit Measurements for Adaptive Feedback via Measurement Randomized Compiling

Quantum measurements are a fundamental component of quantum computing. However, on present-day quantum computers, measurements can be more error prone than quantum gates and are susceptible to nonunital errors as well as nonlocal correlations due to measurement crosstalk. While readout errors can be mitigated in postprocessing, this is inefficient in the number of qubits due to a combinatorially large number of possible states that need to be characterized. In this work, we show that measurement errors can be tailored into a simple stochastic error model using randomized compiling, enabling the efficient mitigation of readout errors via quasiprobability distributions reconstructed from the measurement of a single preparation state in an exponentially large confusion matrix. We demonstrate the scalability and power of this approach by correcting readout errors without matrix inversion on a large number of different preparation states applied to a register of eight superconducting transmon qubits. Moreover, we show that this method can be extended to midcircuit measurements used for active feedback via quasiprobabilistic error cancellation, and we demonstrate the correction of measurement errors on an ancilla qubit used to detect and actively correct bit-flip errors on an entangled memory qubit. Our approach enables the correction of readout errors on large numbers of qubits and offers a strategy for correcting readout errors in adaptive circuits in which the results of midcircuit measurements are used to perform conditional operations on nonlocal qubits in real time.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC

Readout optimization of multi-amplifier sensing charge-coupled devices for single-quantum measurement

The non-destructive readout capability of the Skipper Charge Coupled Device (CCD) has been demonstrated to reduce the noise limitation of conventional silicon devices to levels that allow single-photon or single-electron counting. The noise reduction is achieved by taking multiple measurements of the charge in each pixel. These multiple measurements come at the cost of extra readout time, which has been a limitation for the broader adoption of this technology in particle physics, quantum imaging, and astronomy applications. This work presents recent results of a novel sensor architecture that uses multiple non-destructive floating-gate amplifiers in series to achieve sub-electron readout noise in a thick, fully-depleted silicon detector to overcome the readout time overhead of the Skipper-CCD. This sensor is called the Multiple-Amplifier Sensing Charge-Coupled Device (MAS-CCD) can perform multiple independent charge measurements with each amplifier, and the measurements from multiple amplifiers can be combined to further reduce the readout noise. We will show results obtained for sensors with 8 and 16 amplifiers per readout stage in new readout operations modes to optimize its readout speed. The noise reduction capability of the new techniques will be demonstrated in terms of its ability to reduce the noise by combining the information from the different amplifiers, and to resolve signals in the order of a single photon per pixel. The first readout operation explored here avoids the extra readout time needed in the MAS-CCD to read a line of the sensor associated with the extra extent of the serial register. The second technique explore the capability of the MAS-CCD device to perform a region of interest readout increasing the number of multiple samples per amplifier in a targeted region of the active area of the device.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Neutron capture measurements at UMass lowell research reactor

A new facility was designed around the thermal column beam port of the 1 MW Research Reactor at the University of Massachusetts Lowell. Thermal neutrons are collimated to a 1-inch diameter beam and incident on samples to induce the radiative neutron capture. New measurements of capture gamma rays are planned for Mn, Cu, Ni, Cr, and Gd samples in the next few years. The experiments will be carried out in close collaboration with the ENSDF (Evaluated Nuclear Structure Data File) evaluation group at Brookhaven National Laboratory. The gamma rays are measured using an array of high-resolution HPGe detectors. Some of the HPGe detectors use active Compton shields that were designed from scintillation detectors and improve significantly the signal-to-background in the measured gamma-ray spectra with HPGe. The experimental spectra will be validated by the GEANT4 simulations of the array and theoretical models of the emission of gamma rays from the compound nucleus. In conclusion, the new experimental results on the capture gamma ray intensities will be incorporated in future ENSDF evaluations.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Measuring error rates of mid-circuit measurements

High-fidelity mid-circuit measurements, which read out the state of specific qubits in a multiqubit processor without destroying them or disrupting their neighbors, are a critical component for useful quantum computing. They enable fault-tolerant quantum error correction, dynamic circuits, and other paths to solving classically intractable problems. But there are few methods to assess their performance comprehensively. In this work, we address this gap by introducing the first randomized benchmarking protocol that measures the rate at which mid-circuit measurements induce errors in many-qubit circuits. Using this protocol, we detect and eliminate previously undetected measurement-induced crosstalk in a 20-qubit trapped-ion quantum computer. Then, we use the same protocol to measure the rate of measurement-induced crosstalk error on a 27-qubit IBM Q processor, and quantify how much of that error is eliminated by dynamical decoupling.

Hothem, Daniel [Sandia National Laboratories (SNL-

Laser absorption measurements of temperature, pressure, CO, and CO 2 at near-MHz rates in post-detonation fireballs with comparison to synthetic measurements

A laser absorption spectroscopy (LAS) diagnostic was used to obtain measurements of temperature, pressure, CO, and CO 2 at 500 kHz or 1 MHz in post-detonation fireballs produced by hemispherical samples of pentaerythritol tetranitrate (PETN). A quantum-cascade laser was scanned over multiple CO absorption transitions near 2008.5 cm −1 at 1 MHz, while an interband-cascade laser was scanned over a CO 2 absorption transition near 2394.8 cm −1 at 500 kHz. Light from each laser was combined onto a single path and passed through a detonation chamber approximately 83 mm above the 12-mm diameter hemispherical PETN charge. The CO and CO 2 absorption signals were post-processed to obtain time histories of temperature, pressure, species column pressures (P CO L, P CO2 L), and species column mole fractions (X CO L, X CO2 L). Additionally, schlieren imaging was performed simultaneously at 500 kHz to aid interpretation of the LAS measurements. Experimental and synthetic (i.e., CFD based) LAS measurements were compared to evaluate the accuracy of the CFD model and its ability to model the turbulent afterburning of the detonation products in air. In general, the experimental measurements exhibit reasonable agreement with the synthetic measurements at early times; thereby supporting the accuracy of the CFD model. Periods of disagreement between experimental and synthetic measurements at later times are most likely due to a reflected shock and detonator cavity jetting, which are not accounted for in the CFD model.

Schwartz, Charles J. [Purdue Univ., West Lafayette

The impact of optical measurement techniques on measured aerosol particle size distributions

Ambient aerosol particle size distributions measured by the Ultra-High Sensitivity Aerosol Spectrometer (UHSAS) at various sites around the world exhibit modes at optical diameters near 600 nm and 850 nm. These modes are not present in concurrent measurements with the Grimm 11-D Optical Particle Counter (OPC). Here, in this study, we argue that these modes result from the optical measurement technique itself, and we explain why they appear in measurements by the UHSAS but not in those by the Grimm OPC. We construct computer models of the UHSAS and Grimm (“digital UHSAS” and “digital Grimm”) and use these to investigate the size distribution that would result from measurements of artificial aerosol particle size distributions that do not contain modes. The appearance of modes for the structureless incoming size distributions sampled by the digital UHSAS is explained by the nonlinear behavior of partial scattering cross sections of uniform spherical particles as a function of their diameter. The absence of modes in the digital Grimm is explained by the coarser size resolution of that instrument. Detailed analysis of the relationship between optical and geometric diameters for uniform spherical particles reveals two important results. First, these diameters generally have different numerical values for the same particle, and second, the relationship is nonlinear; thus, widths of size bins in terms of optical diameter differ from those in geometric diameter. These results explain the modes observed in the ambient size distributions and highlight concerns with attempts to create a merged size distribution by combining measurements from different instruments.

54 ENVIRONMENTAL SCIENCES

Measurement of the 252 Cf ⁢(sf) prompt fission neutron spectrum utilizing 12 C ⁡(𝑛, 𝑛) and 9 Be ⁢(𝑛, 𝑛) neutron scattering reference measurements

The 252 Cf spontaneous fission (sf), prompt fission neutron spectrum (PFNS) is a fundamental quantity for nuclear physics measurements of neutron-emitting reactions. This energy distribution of neutrons emitted from fission has been considered a neutron data standard for decades and has been utilized as a reference for neutron detection efficiency, validation of Monte Carlo simulations, benchmarking of dosimetry standards, and more. A significant portion of the global collection of nuclear data on neutron-induced reactions is correlated with the 252 Cf ⁢(sf) PFNS. Despite the reliance on this quantity by the nuclear physics community, the historical collection of 252 Cf PFNS measurements display systematic disagreements that are not understood or easily explained. These experimental discrepancies could potentially bias the 252 Cf PFNS Standard evaluation. On top of this, these past experiments frequently employed correlated experimental measurement or analysis methods. The artificial intelligence (AI)/machine learning (ML)-informed californium chi-nuclear data experiment (AIACHNE) project was formed to (a) investigate these discrepancies utilizing AI/ML methods to identify outlying regions of literature data, assign these regions to features of the experiment itself, and perform an improved evaluation of the 252 Cf PFNS and (b) perform a new experimental measurement of this quantity designed to improve upon the existing literature database. Here, in this work, we report on the AIACHNE 252 Cf PFNS experiment utilizing a new analysis method uncorrelated with all previous measurements: neutron efficiency determinations based on elastic neutron scattering on 12 C and 9 Be . This new method provides an independent test of the existing literature data and evaluation of the 252 Cf ⁢(sf) PFNS. The method is described with detailed covariance quantification procedures, as well as a direct discussion of the sources of uncertainty described as requirements in the “Templates” series of papers. The 252 Cf ⁢(sf) PFNS reported in this work agrees well with the overall shape of the existing standard PFNS evaluation as well as many literature measurements, thus verifying the current evaluation utilizing new techniques. However, the results suggest that there are deficiencies in the angle-differential 12 C and 9 Be ⁢(𝑛, 𝑛) evaluated nuclear data, which produce unphysical structures in the reported result. While these structures are relatively minor, they become obvious because of the high statistical precision of the data and the expected smooth continuity of the 252 Cf ⁢(sf) PFNS.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

Final design and first use of in-situ measuring apparatus for measurement of permanent magnet resiliency in CEBAF’s radiation environment

In this work we outline the final design and initial measurement lessons for the holders and measuring apparatus of the permanent magnet resiliency experiment which is a part of the FFA@CEBAF proposed upgrade. The experiment will expose permanent magnets to the radiation environment of CEBAF. Due to safety regulations we need to measure the magnets in the tunnel without bringing them out, so we designed a mobile measuring system as well as a series of protocols to allow us to speedily measure these samples even under adverse conditions. We also designed our system to be capable of taking measurements even with component failures.

Accelerator Physics

Comparison of the sensitivity of 236 U measurements in environmental samples by MC-ICP-MS and ATONA based high precision U TIMS measurements

The ATONA project is focused upon exploring the improvements in uranium isotope ratio measurements by thermal ionization mass spectrometry (TIMS) provided by a new, capacitor-based, amplifier technology. These “ATONA” Faraday amplifiers (Isotopx Ltd, UK) promise accurate, low-noise measurements of very small signals (< 1 femto-amp) in a traditional Faraday cup, which was only previously possible using an ion counter. This report outlines a series of experiments that were performed to assess the performance of the system in samples that test our rapid analysis procedures, and then compare the results against other mass spectrometry techniques currently available for environmental analyses. The following major goals were achieved: (1) illustrated the importance of 236 U measurements for the screening and analysis of environmental samples; (2) improved sensitivity for 236 U, and then identified 236 U in the 4350B standard at ultra-trace levels (3) Provided comparison of the 236 U sensitivity to multi-collector inductively coupled mass spectrometry techniques (4) Illustrated high TRL for the ATONA based measurement technique. This completes the reporting requirements for task 4 in the project LCP and highlights the utility of the system to make highly sensitive 236 U measurements in programmatically relevant sample matrices and at relevant uranium concentrations.

07 ISOTOPE AND RADIATION SOURCES

Fast and sensitive measurements of sub-3 nm particles using Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM)

New particle formation (NPF) is the atmospheric process whereby gas molecules react and nucleate to form detectable particles. NPF has a strong impact on Earth's radiative balance as it produces roughly half of global cloud condensation nuclei. However, the time resolution and sensitivity of current instrumentation are inadequate in measuring the size distribution of sub-3 nm particles, the particles critical for understanding NPF. Here we present the Condensation Particle Counters For Atmospheric Rapid Measurements (CPC FARM), a method to measure the concentrations of freshly nucleated particles. The CPC FARM consists of five CPCs operating in parallel, each configured to operate at different detectable particle sizes between 1–3 nm. This study explores two methods to calculate the size distribution from the differential measurements across the CPC channels. The performance of both inversion methods was tested against the size distribution measured by a pair of stepping particle mobility sizers (SMPSs) during an ambient air sampling study in Pittsburgh, PA. Observational results indicate that the CPC FARM is more accurate with higher time resolution and sensitivity in the sub-3 nm range compared to the SMPS.

Cheng, Darren [Carnegie Mellon Univ., Pittsburgh,

Tidal energy resource characterization measurements at Cook Inlet’s East Foreland: Velocity and turbulence

To characterize tidal current and turbulence at a top tidal energy site off the East Foreland in Cook Inlet, Alaska, United States, three moorings were deployed for two months between July and August 2021, and a transect survey was conducted over the course of two tidal cycles at the end of the deployment period. Measurements of velocity and turbulence were then analyzed to better understand the site's hydrodynamics and power potential. Analysis reveals that swift, north-flowing flood currents peak at 4~m/s, while south-flowing ebb currents reach just over 3~m/s. Turbulence intensity ranges from 23\% at the seafloor to 8\% near the surface, and the presence of the foreland creates more intense turbulence near-shore during ebb tide than flood. Power availability at the site could be as high as 720~MW, or 13~kW/m$^2$, though the energy available to a marine energy device will be smaller than this estimate because of water-to-wire efficiency and wake losses. The results from this measurement campaign will inform the validation of a high-resolution tidal hydrodynamic model, as well as early tidal energy projects that are beginning to move beyond the prototyping and demonstration stages to full-scale deployments.

McVey, James R.

Interference fringe (IF) technique for droplet contact angle and thickness measurements: Ultralow contact angle and nanoscale thickness measurement

Recently, reflection interference fringe (RIF) and transmission fringe (TIF) techniques have been introduced to investigate the origin of far-field interference fringe (IF) formation and to determine a droplet's contact angle and thickness by measuring the fringe radius. In this study, characteristics of the IF technique are analyzed based on the RIF and TIF by varying the schematics, such as configuration (transmission/reflection), the droplet's side (left-hand side/right-hand side), and the substrate types (flat/prism). The analysis also investigates the refraction effect at the droplet edge and the maximum incidence and contact angles. The schematic variation shows that the widest contact angle range can be measured in a transmission configuration with droplet's right-hand side, and that the fringe radius decreases with incidence angles on a prism substrate, consistent with the recent observation. Refraction at the droplet edge causes the fringe radius to increase or decrease depending on the degree of refraction. Based on the characteristics study, it is revealed that the IF technique can determine nanometer-scale thicknesses below 100 nm on droplets, corresponding to ultra-small contact angles of less than 0.01°, with an extended working distance of 3000 mm and an optimized incidence angle, assuming a spherical profile. This finding is significant, as it demonstrates that the nanoscale thickness can be determined in situ under ambient conditions using a simple optical configuration, without requiring a sophisticated setup, such as a microscope. It is anticipated that the IF technique can be combined with other nanoscale thickness measurement techniques to enhance its measurement reliability.

36 MATERIALS SCIENCE

Measurement of the transverse energy density in Measurement of the transverse energy density in Au + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV with the sPHENIX detector

Here, this paper reports measurements of the transverse energy per unit pseudorapidity (𝑑⁢𝐸 𝑇 /𝑑⁢𝜂) produced in Au + Au collisions at $\sqrt{𝑠_{𝑁⁢𝑁}}$ = 200 GeV, performed with the sPHENIX detector at the Relativistic Heavy Ion Collider (RHIC). The results cover the pseudorapidity range |𝜂| < 1.1 and constitute the first such measurement performed using a hadronic calorimeter at RHIC. Measurements of 𝑑⁢𝐸 𝑇 /𝑑⁢𝜂 are presented for a range of centrality intervals and the average 𝑑⁢𝐸 𝑇 /𝑑⁢𝜂 as a function of the number of participating nucleons, 𝑁 part , is compared to a variety of Monte Carlo heavy-ion event generators. The results are in agreement with previous measurements at RHIC, and feature an improved granularity in 𝜂 and improved precision in low-𝑁 part events.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS

A precise measurement of the jet energy scale derived from single-particle measurements and in situ techniques in proton–proton collisions at $\sqrt{s}=$ 13 TeV with the ATLAS detector

The jet energy calibration and its uncertainties are derived from measurements of the calorimeter response to single particles in both data and Monte Carlo simulation using proton–proton collisions at $\sqrt{s} = 13$ TeV collected with the ATLAS detector during Run 2 at the Large Hadron Collider. The jet calibration uncertainty for anti-$k_T$ jets with a jet radius parameter of R$_\textrm{jet} = 0.4$ and in the central jet rapidity region is about 2.5% for transverse momenta ($p_{\text {T}}$) of 20 $\text {GeV}$ , about 0.5% for $p_{\text {T}} = 300$ GeV and 0.7% for $p_{\text {T}} = 4$ TeV . Excellent agreement is found with earlier determinations obtained from -balance based in situ methods ($Z/\gamma$ +jets). The combination of these two independent methods results in the most precise jet energy measurement achieved so far with the ATLAS detector with a relative uncertainty of 0.3% at $p_\textrm{T} = 300$ GeV and 0.6% at 4 TeV. The jet energy calibration is also derived with the single-particle calorimeter response measurements separately for quark- and gluon-induced jets and furthermore for jets with R jet varying from 0.2 to 1.0 retaining the correlations between these measurements. Differences between inclusive jets and jets from boosted top-quark decays, with and without grooming the soft jet constituents, are also studied.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS

Integration of a real-time orientation measurement system for a real-time evaluator (RTE) to measure the position and orientation of crane-lifted components

Prefabrication of building components holds the potential to revolutionize the construction industry. Prefabrication consists of manufacturing building components, modules, and other elements in a factory to be shipped and installed on a construction site. Prefabricated components have been produced for various applications including precast concrete panels for new construction and exterior wall retrofits. The manufacturing process has seen much innovation in recent years; however, the installation process has seen minimal advancements. A real-time evaluator (RTE) was developed to reduce the installation cost of prefabricated components by reducing installation time, decreasing rework, and improving accuracy. The RTE uses off-the-shelf hardware and novel algorithms to assist erectors with component installation by measuring the real-time positions of connections and prefabricated components, providing installation guidance through a graphical user interface, and monitoring the accumulated installation errors. An overview of the RTE and the proposed workflow is presented. Previous on-site demonstrations provided valuable feedback from users on the potential areas for improvement of the system. One common request was real-time measurement of component orientation during lifting, a process that previously required that the component remain stationary while the laser tracker cycled through target prisms. This paper will present the incorporation and testing of a real-time orientation measurement system as it was implemented into the RTE, allowing for measurement of component orientation during movement.

Selvakumar, Balaji [ORNL]

Advancing Building Air Leakage Measurement and Modeling: Measurement of Interior Air Leaks, Experimental Comparison to Conventional Methods, and Building Modeling Characteristics

This report, Advancing Building Air Leakage Measurement and Modeling: Measurement of Interior Air Leaks, Experimental Comparison to Conventional Methods, and Building Modeling Characteristics, developed two new building air leakage measurement methods, experimentally evaluated the performance in comparison to conventional methods, experimentally evaluated the behavior of leaks for specific crack structures, and identified testing constraints and model implications.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI