Comparing Server Energy Use and Efficiency Using Small Sample Sizes

This report documents a demonstration that compared the energy consumption and efficiency of a limited sample size of server-type IT equipment from different manufacturers by measuring power at the server power supply power cords. The results are specific to the equipment and methods used. However, it is hoped that those responsible for IT equipment selection can used the methods described to choose models that optimize energy use efficiency. The demonstration was conducted in a data center at Lawrence Berkeley National Laboratory in Berkeley, California. It was performed with five servers of similar mechanical and electronic specifications; three from Intel and one each from Dell and Supermicro. Server IT equipment is constructed using commodity components, server manufacturer-designed assemblies, and control systems. Server compute efficiency is constrained by the commodity component specifications and integration requirements. The design freedom, outside of the commodity component constraints, provides room for the manufacturer to offer a product with competitive efficiency that meets market needs at a compelling price. A goal of the demonstration was to compare and quantify the server efficiency for three different brands. The efficiency is defined as the average compute rate (computations per unit of time) divided by the average energy consumption rate. The research team used an industry standard benchmark software package to provide a repeatable software load to obtain the compute rate and provide a variety of power consumption levels. Energy use when the servers were in an idle state (not providing computing work) were also measured. At high server compute loads, all brands, using the same key components (processors and memory), had similar results; therefore, from these results, it could not be concluded that one brand is more efficient than the other brands. The test results show that the power consumption variability caused by the key components as a group is similar to all other components as a group. However, some differences were observed. The Supermicro server used 27 percent more power at idle compared to the other brands. The Intel server had a power supply control feature called cold redundancy, and the data suggest that cold redundancy can provide energy savings at low power levels. Test and evaluation methods that might be used by others having limited resources for IT equipment evaluation are explained in the report.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Comparing datasets of volume servers to illuminate their energy use in data centers

As data centers proliferate, their energy intensity deserves close attention. Always-on operations and growing usage for cloud and other backend processes make servers the fundamental driver of data center energy use. Yet servers’ power draw under real-world conditions is poorly understood. This paper explores characteristics of volume servers that affect energy use, quantifying differences in power draw between higher-performing Standard Performance Evaluation Corporation (SPEC) and ENERGY STAR servers and that of a typical server. First, we establish general characteristics of the US installed base, before reporting hardware configurations from a major online retail website. We then compare idle power across three datasets (one unique to this paper) and explain their differences via the hardware characteristics to which power draw is most sensitive. We find idle server power demand to be significantly higher than benchmarks from ENERGY STAR and the industry-released SPEC database, and SPEC server configurations—and likely their power scaling—to be atypical of volume servers. Next, we examine power draw trends among high-performing servers across their load range to consider whether these trends are representative of volume servers, before inputting average idle power load values into a recent national server energy use model. Lastly, results from two surveys of IT professionals illustrate the incidence of more efficient equipment and operational practices in server rooms/closets. Future work should include server power field measurements in data centers of different sizes, accounting for variations in configurations and setting changes post-purchase, as well as investigating the linkage between time and server energy efficiency.

Fuchs, Heidi (ORCID:0000000300105411)↗

LEED: A Lightwave Energy-Efficient Datacenter

The Lightwave Energy-Efficient Datacenter (LEED) program is a disruptive “green-field” approach that provides a quantum leap in the energy efficiency of datacenters. LEED’s fundamental value proposition is that a novel and re-architected optical network—RotorNet— can deliver “more bandwidth per buck” as well as unique system-level attributes that significantly improve overall datacenter energy efficiency and performance. LEED has developed three system-level testbeds. The first testbed uses calibrated hardware and software power measurements to determine server energy efficiency as a function of network bandwidth and workload. These measurements have shown that increasing network communications bandwidth dramatically increases server energy efficiency providing a realistic path to the overall ENLITENED program goal of doubling the number of transactions per joule. The second testbed demonstrates key hardware: a prototype low-loss, high-port count optical “selector switch”. This switch was fabricated, racked, and tested. Measured switch characteristics include loss, bandwidth, crosstalk, switch time, system-level switch time (including the transceivers), and bit error rate. The third testbed demonstrates a fully working and manufactured pinwheel design which dramatically lowers the cost of design, while delivering high switch radix and low reconfiguration times. The LEED project has tied these three novel photonic switch prototypes together with production servers and software through the development of a novel FPGA-based NIC platform called Corundum. Corundum ensures that the packet-switched protocols supported by commodity operating systems and devices can interface with the Rotor switch design. The LEED group has used this combined hardware and software prototype to characterize applications running at a commercially relevant scale. The project has used a combination of enhanced optical modulation amplitude (OMA) modulators, broadband multiplexers and demultiplexers, avalanche photodiodes, and a novel burst-mode receivers to enable the insertion of LEED-developed optical switches without the need for expensive optical amplification. Our modeling has shown that measured LEED-developed device characteristics can achieve link characteristics of 2 pJ/bit including both transceivers and the Rotor switch. In summary, the LEED program has demonstrated a credible and practical path, through novel hardware and software, to realize the program objectives of ENLITENED. The net result will ensure that the United States maintains its strength in the crucial sector of Information Technology, which is vital to both our economic security and our national security.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Performance analysis of Wald-statistic based network detection methods for radiation sources

There have been increasingly large deployments of radiation detection networks that require computationally fast algorithms to produce prompt results over ad-hoc sub-networks of mobile devices, such as smart-phones. These algorithms are in sharp contrast to complex network algorithms that necessitate all measurements to be sent to powerful central servers. In this work, at individual sensors, we employ Wald-statistic based detection algorithms which are computationally very fast, and are implemented as one of three Z-tests and four chi-square tests. At fusion center, we apply the K-out-of-N fusion to combine the sensors hard decisions. We characterize the performance of detection methods by deriving analytical expressions for the distributions of underlying test statistics, and by analyzing the fusion performances in terms of K, N, and the false-alarm rates of individual detectors. We experimentally validate our methods using measurements from indoor and outdoor characterization tests of the Intelligence Radiation Sensors Systems (IRSS) program. In particular, utilizing the outdoor measurements, we construct two important real-life scenarios, boundary surveillance and portal monitoring, and present the results of our algorithms.

Sen, Satyabrata↗

Power system model parameter conditioning tool

A power system model parameter conditioning tool including a server control processor in communication with phasor measurement unit monitored data records of multiple disturbance events, a model calibration unit providing event screening, power system model simulation, and simultaneous tuning of model parameters. The model calibration performing a simulation using default model parameters, the processor comparing the simulation results to the monitored data. If the prediction is within threshold, then terminating conditioning; else performing parameter identifiability analysis to determine differing effects of various model parameters on power system model accuracy, selecting a parameter set causing a degradation in power system model prediction, and updating the default model parameters corresponding to members of the parameter set with values selected to reduce the degradation. A method and a non-transitory computer readable medium are also disclosed.

Baone, Chaitanya Ashok↗

Outdoor Test Bed Performance of a Power Line Sensor Using a Real-Time Event Simulator

This report summarizes the design and application of an outdoor power line sensor testbed (OPLST) with a real-time simulator and power meter to compare a potential transformer (PT) and current transformer (CT) versus an advanced line-post sensor. The OPLST was created to validate advanced medium-voltage (20/34.5 kV) outdoor power line sensors used in electrical distribution systems. Electrical utilities have installed metering and relay-protection transformers like PTs and CTs for several decades. The PTs/CTs are iron core measurement transformers based on the electromagnetic induction principle and provide reliable data in normal grid operation. However, new outdoor power line sensors (OPLS) using other technologies like voltage divider, Rogowski coil and optical principles have become available and may have favorable performance and costs compared to PTs/CTs. Therefore, the importance of testing these technologies with the PT/CT, to compare the measured phase voltage/current at different power grid scenarios is crucial to understand the performance of these new OPLS. For this study a G&W Electric Model CVS-36-O power line sensor was chosen as the OPLS to test with voltage/current signals. An OPAL-RT Technologies Model OP4510 real-time simulator and Schweitzer Engineering Laboratories Model SEL-735 power meter were installed with the 20/34.5 kV OPLST to compare the measured transient events collected from an advanced OPLS and the PT/CT. This system is installed at the Distributed Energy Communications and Control (DECC) lab, Oak Ridge National Laboratory (ORNL). The simulator generated different power grid scenarios (electrical faults, capacitor bank operation, service restoration, etc.), and its analog-output signals were connected to the voltage/current amplifiers that feed the 20/34.5 kV aerial cable loop through the PT/CT devices. Additional PT/CT devices were also wired with the medium voltage aerial cable loop to measure the phase current/voltage signals and server as references. After each test, common format for transient data exchange (COMTRADE) files were collected from the SEL-735 power meter and used to compare the performance of the OPLS with the PT/CT. The behavior of analog signals, harmonic components, total harmonic distortion and crest factors were assessed and found favorable for the G&W sensor as compared to the reference PT/CT.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Blockchain-Enabled Cyber-Secure Microgrid Control Using Consensus Algorithm

This paper proposes a distributed control method based on a consensus algorithm for distributed energy resources (DERs) using blockchain as a secure communication medium for cyber resilience. Each DER communicates with a local blockchain server that is maintained by the distributed ledger technology to allow for securely sharing local measurements among neighbouring assets to achieve the global control objectives, i.e., voltage and frequency regulation as well as accurate power sharing among the DERs, including collective grid-forming capability. To prove that the distributed control can retain system stability under a blockchain-induced variable communication delay, Lyapunov function-based stability analysis is carried out. This paper demonstrates the concept on an 11-bus test case developed in MATLAB Simulink, which has been modified from the IEEE 9-bus test case, to study dynamic operations of the five inverter-based DERs working with a blockchain-induced variable delay. The results validate the superior performance of the proposed control method, compared to heavily compromised operations of the other test cases without the security measure, affected by heavy communication delays and communication interruptions.

blockchains↗

Adding power of artificial intelligence to situational awareness of large interconnections dominated by inverter‐based resources

Abstract Large‐scale power systems exhibit more complex dynamics due to the increasing integration of inverter‐based resources (IBRs). Therefore, there is an urgent need to enhance the situational awareness capability for better monitoring and control of power grids dominated by IBRs. As a pioneering Wide‐Area Measurement System, FNET/GridEye has developed and implemented various advanced applications based on the collected synchrophasor measurements to enhance the situational awareness capability of large‐scale power grids. This study provides an overview of the latest progress of FNET/GridEye. The sensors, communication, and data servers are upgraded to handle ultra‐high density synchrophasor and point‐on‐wave data to monitor system dynamics with more details. More importantly, several artificial intelligence (AI)‐based advanced applications are introduced, including AI‐based inertia estimation, AI‐based disturbance size and location estimation, AI‐based system stability assessment, and AI‐based data authentication.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Data Analytics for Electrical Distribution Systems with Micro PMUs (GMLC 1.4.9 Technical Report)

This report describes how electrical utilities with residential, industrial, commercial and government customers make decisions using Data Analytics (DA) applications and discusses how OpenFMB was leveraged to share that data among disparate types of devices for DA. OpenFMB is a data standard developed by utilities for distributed communication and control of power system assets. Here we explored how OpenFMB can be used for sharing analytics and what those analytics could be for a set of representative grid devices. A review of DA applications performed by electrical utilities and customers is presented. An overview of how the testbed we used was built and configured is summarized. Several experiments which were carried out to explore the capabilities of OpenFMB alongside other data sharing mechanisms for gathering sensor measurements and sharing analytics is also discussed. And finally a comparison of OpenFMB and LBNL’s SPARK framework is summarized. Today’s electrical utilities focus on monitoring the real-time customer consumptions, offering new real-time tariff models based on customer usage habits (rewards and punishments), providing energy peak during peak load times (plan energy generation and distribution), improving the load management for transformers and power lines, and controlling the energy and grid resources efficiently. On the other hand, the DA applications for residential customers are based on modifying the customer electricity usage habit to save money, making accurate and timely decisions for electrical billing. However, the DA applications for industrial, commercial and government customers focus on creating efficient programs to improve the environmental condition (reducing CO₂ emission), developing better load forecasting for industrial and/or commercial activities. In this project, a testbed was built to explore how the OpenFMB framework can be used to distribute data among various types of representative grid edge devices. Micro PMUs (Phasor Measurement Unit) were used to collect and transmit data to an OpenPDC server alongside relays with a framework configured with a system using OpenFMB to collect and transmit data. The testbed was composed of a physical asset based on a 60 Hz AC radial power system constructed using SI-GRID components. The power system consisted of a 3-phase 14 volts line-to-ground (24 volts line-to-line) power source, three 3-phase line emulators, a programmable resistive load bank, two smart relays, two micro PMUs, and a (SCADA) and Phasor Data Concentrator (PDC) computer. This testbed configuration allowed us to perform breaker operation tests collecting data from the micro PMUs and from the relays’ sensors. During the micro PMU breaker operation tests we collected the measured and estimated fundamental voltages, currents, frequency as well as the total true, reactive and apparent power. The displacement power factor from two micro PMUs located in parallel power lines was also used. The software steps for the implementation of the Synchrophasor system are explained in detail in this report. The setting (1-2-3) and data collection (4-5) phases were performed with a free download open source software. In the setting phase, the micro PMUs were set (1), the data stream for each micro PMU was validated, and the connection and configuration files were created (2). The PDC computer was set using the connection and configuration files of the micro PMUs (3). In the data collection phase, the binary data from the micro PMUs was collected (4), and the binary data files of the micro PMUs was converted to analyze the test results (5). OpenFMB was configured to use protocol translators to read Modbus and transform the reading into the OpenFMB data model to be read for DA applications.Our experiments showed that by leveraging the OpenFMB data model and the micro PMUs together we could obtain better situational awareness of network faults, which in some cases could lead to failures in the system and would be less perceivable otherwise. For example, in one experiment the fundamental RMS current angle, and the fundamental displacement power factor (estimated by the ratio between the measured real and apparent total power) had a disturbance at the micro PMU connected to the beginning of the parallel power line because the breaker was opened without the operators or SCADA system’s knowledge, and no current was available. Based on the breaker state scenarios and micro PMU locations, the DA applications using the current angle and displacement power factor from the micro PMUs should be studied in detail to avoid a non-desired measurement that could affect the decision from the DA. Also, the sample rates for PMU, Relay and micro PMU devices were compared. The DA application improved the control and operation between the electrical utilities and their customers (residential, industrial, transportation, commercial and government). The higher the sample rate, the better the quality of the measurement for DA estimations.

42 ENGINEERING↗

Blockchain-Enabled Cyber-Secure Microgrid Control Using Consensus Algorithm: Preprint

This paper proposes a distributed control method based on a consensus algorithm for distributed energy resources (DERs) using blockchain as a secure communication medium for cyber resilience. Each DER communicates with a local blockchain server that is maintained by the distributed ledger technology to allow for securely sharing local measurements among neighboring assets to achieve the global control objectives, i.e., voltage and frequency regulation as well as accurate power sharing among the DERs, including collective grid-forming capability. To prove that the distributed control can retain system stability under a blockchain-induced variable communication delay, Lyapunov function-based stability analysis is carried out. This paper demonstrates the concept on an 11-bus test case developed in MATLAB Simulink, which has been modified from the IEEE 9-bus test case, to study dynamic operations of the five inverter-based DERs working with a blockchain-induced variable delay. The results validate the superior performance of the proposed control method, compared to heavily compromised operations of the other test cases without the security measure, affected by heavy communication delays and communication interruptions.

blockchain↗

Methods and systems for detection of man-in-the-middle attacks for SCADA communication networks and applications of same

A system for detecting MITM for SCADA communication networks includes secure substation-substation communication links for providing secure and reliable paths to exchange OT data between substations for OT data consistency check; a SIB in each substation for sampling CT and PT measurements to calculate voltage magnitude and phase angle thereof; a S&C server in each substation coupled to the SIB for receiving the voltage magnitude and phase angle from the SIB and obtaining a packet carrying active power flow in transmission lines between two substations and a time stamp; an IDS server placed in a SCADA center for collecting the packet of each substation sent by the S&C server; analyzing the received packet from every adjacent substation; inspecting the payload of the received packet; and triggering an intrusion alarm to a SCADA operator when the power flow is not the same as the payload of the packets.

McCann, Roy A.↗

Validating Safecast data by comparisons to a U. S. Department of Energy Fukushima Prefecture aerial survey

Safecast is a volunteered geographic information (VGI) project where the lay public collects radiation measurements via hand-held sensors that are uploaded to a central server and then made freely available. However, Safecast data fidelity is uncertain given that the these sensors are hand assembled with various levels of technical proficiency, and that the sensors may not be properly deployed. We validated Safecast data gathered in the Fukushima Prefecture shortly after the Daiichi nuclear power plant catastrophe by comparing it with authoritative data collected by the Department of Energy (DOE) and the National Nuclear Security Administration (NNSA) during the same period. We found that the two data sets were highly correlated, though the DOE/NNSA observations were generally higher than the Safecast measurements. We concluded that this high correlation alone makes Safecast a viable data source for detecting and monitoring fallout during radiological emergencies.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

NREL Energy Performance Testing of Asetek's RackCDU System on a Single Rack of Twin Blade Servers: Cooperative Research and Development Final Report, CRADA Number CRD-13-518

The project will entail Asetek retrofitting 1 - 2 compute racks of servers at the National Renewable Energy Laboratory (NREL) to test and validate RackCDU's cooling performance and long-term reliability. The project will also entail measuring and reporting energy savings under a real workload by comparing total power input to the system vs. total heat removed by liquid and air. Direct measurements will be made to compare and contrast energy consumption and performance both before and after RackCDU installation. The scope of this project is strictly demonstration and feedback on the system. No development work will be performed under this CRADA.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

SOL: An end-to-end solution for real-world remote monitoring systems

This paper introduces SOL, which is both an efficient data representation for sensor measurements and network statistics, and a complete low-power wireless sensor management system that builds around it. A SOL system consists of multiple low-power wireless mesh networks in which motes connected to sensors and actuators send data to a single server. It offers multi-tier data replication and the associated data recovery. SOL is used in 3 pilot deployments for micro-climate monitoring, building automation and agriculture applications. In conjunction with Metronome Systems' NeoMote and Manager devices, SOL is a turn-key ready-to-deploy end-to-end system.

47 OTHER INSTRUMENTATION↗

Big Data Processing for Power Grid Event Detection

In this paper we present the application of big data processing for the development of machine learning (ML) models to detect relevant events in power grid operations. This is based on almost 20TB of phasor measurement unit data corresponding to up to two years of operation of three grid interconnections which provide power to most of the United States. A significant aspect of the work consists in having all data processing performed on a single standard GPU server, from pre-processing to ML model training and testing. We describe the data and computational infrastructure, challenges faced and methods used in data processing, main findings and results. The ML approach employed for best utilization of the big data is also discussed, including sample results.

Paes Leao, Bruno↗

Steel Creek, Pen Branch, and D-Area Watershed Stream Gauging Stations

A network of stream gauging systems were installed in the Steel Creek, Pen Branch, D-Area Discharge Canal, and the D006 Stream in support of the groundwater modeling efforts for the P-Area Groundwater Operable Unit (OU); Chemical, Metals, and Pesticides (CMP) Pits OU; and the D-Area Watershed, respectively. Each location is monitored by a MACE Floseries3 FloPro data logger and a MACE doppler ultrasonic area/velocity sensor. Each stream gauging system is powered by an internal 12-volt battery supplied by a solar panel with a trickle charger. Information collected by each data logger is logged internally and telecommunicated via a cellular network to an online server for real time analysis and monitoring. The MACE doppler ultrasonic area/velocity sensor can measure stream depth and velocities to give output values of flow rates, total flow, net flow, and volumes. The water depth is measured by a ceramic pressure transducer located on the top of the sensor. The velocity is measured by a continuous wave doppler sensor to give an average velocity across the whole stream profile. This report discusses the equipment and methods used to install continuous stream gauging stations and provides a summary of data collected through FY2025.

54 ENVIRONMENTAL SCIENCES↗

Energy–Performance Trade-offs in Privacy-Preserving Federated Learning on SmartNIC-Enabled HPC Systems

Federated learning (FL) is increasingly deployed on accelerator-rich high-performance computing (HPC) systems, yet the system-level energy cost of privacy-aware FL remains poorly understood, particularly across heterogeneous networking and server-placement options. We present a measurement-driven study of energy–performance trade-offs for FL on GH200-class nodes across three deployment configurations: CPU-Ethernet, CPU-InfiniBand (RDMA-capable), and a DPU-hosted FL server over InfiniBand using a BlueField-3 SmartNIC/DPU. Using NVIDIA FLARE (NVFLARE), we align node-level power telemetry with per-round timing extracted from NVFLARE logs to quantify time-to-solution (TTS), energy-to-solution (ETS), energy-delay product (EDP), and synchronization behavior for three transformer models (ALBERT, DistilBERT, BERT), trained with and without differential privacy (DP). We find that interconnect choice is the dominant driver of runtime and energy: host-managed InfiniBand consistently reduces communication overhead versus Ethernet, yielding lower TTS/ETS/EDP. In contrast, in our NVFLARE deployment, placing the FL server on the DPU does not consistently match CPU-InfiniBand performance and can be slower—especially for larger models—highlighting that server placement alone is not sufficient to guarantee end-to-end gains. Finally, under our fixed-round protocol, DP increases per-round cost and runtime variance; ETS increases largely in proportion to TTS because average node power remains relatively stable across configurations.

Kotevska, Olivera [ORNL] (ORCID:0000000316772243)↗