Search NASA⌕ Search

SEARCH · Search NASA

Results for “mechanical coolers”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Updated design of the CMB polarization experiment satellite LiteBIRD

Recent developments of transition-edge sensors (TESs), based on extensive experience in ground-based experiments, have been making the sensor techniques mature enough for their application on future satellite CMB polarization experiments. LiteBIRD is in the most advanced phase among such future satellites, targeting its launch in Japanese Fiscal Year 2027 (2027FY) with JAXA's H3 rocket. It will accommodate more than 4000 TESs in focal planes of reflective low-frequency and refractive medium-and-high-frequency telescopes in order to detect a signature imprinted on the cosmic microwave background (CMB) by the primordial gravitational waves predicted in cosmic inflation. The total wide frequency coverage between 34GHz and 448GHz enables us to extract such weak spiral polarization patterns through the precise subtraction of our Galaxy's foreground emission by using spectral differences among CMB and foreground signals. Telescopes are cooled down to 5Kelvin for suppressing thermal noise and contain polarization modulators with transmissive half-wave plates at individual apertures for separating sky polarization signals from artificial polarization and for mitigating from instrumental 1/f noise. Passive cooling by using V-grooves supports active cooling with mechanical coolers as well as adiabatic demagnetization refrigerators. Sky observations from the second Sun-Earth Lagrangian point, L2, are planned for three years. An international collaboration between Japan, USA, Canada, and Europe is sharing various roles. In May 2019, the Institute of Space and Astronautical Science (ISAS), JAXA selected LiteBIRD as the strategic large mission No. 2.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Remediating neutron damage in large area planar Ge-DSSD with amorphous germanium contacts through annealing and pulse-height correction

Large area, position sensitive planar germanium detectors offer new opportunities in -ray spectroscopy. For in-beam studies remediating neutron damage is important. This work studied a mechanically cooled circular planar 9 × 1 cm wafer with orthogonal 16 × 16 amorphous germanium strip electrodes. Before neutron irradiation the wafer was heated in-cryostat to above 373 K for more than 24 h in order to test the robustness of the contacts and the mechanical cooler. No deterioration in performance was observed. The detector was then exposed to controlled doses of 2.2 MeV neutrons, produced from the 7 Li(p,n) 7 Be reaction until substantial damage was observed. Averaged over the surface of the wafer, a flux of 1.9(1) x 10 9 n/cm 2 was delivered. The detector then survived thermal cycling and 350 K (~77°C) annealing for 70 h which substantially reduced hole trapping. pulse-height correction is investigated to further mitigate the neutron damage. Higher temperature annealing at 365 K was not successful.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Thermodynamics of diamond formation from hydrocarbon mixtures in planets

Hydrocarbon mixtures are extremely abundant in the Universe, and diamond formation from them can play a crucial role in shaping the interior structure and evolution of planets. With first-principles accuracy, we first estimate the melting line of diamond, and then reveal the nature of chemical bonding in hydrocarbons at extreme conditions. We finally establish the pressure-temperature phase boundary where it is thermodynamically possible for diamond to form from hydrocarbon mixtures with different atomic fractions of carbon. Notably, here we show a depletion zone at pressures above 200 GPa and temperatures below 3000 K-3500 K where diamond formation is thermodynamically favorable regardless of the carbon atomic fraction, due to a phase separation mechanism. The cooler condition of the interior of Neptune compared to Uranus means that the former is much more likely to contain the depletion zone. Our findings can help explain the dichotomy of the two ice giants manifested by the low luminosity of Uranus, and lead to a better understanding of (exo-)planetary formation and evolution.

75 CONDENSED MATTER PHYSICS, SUPERCONDUCTIVITY AND↗

Compact SRF based accelerator

An accelerator comprising at least one accelerator cavity, an electron gun, at least one cavity cooler configured to at least partially encircle the accelerator cavity, a cooling connector, an intermediate conduction layer formed between the at least one cavity cooler and the at least one accelerator cavity configured to facilitate thermal conductivity between the cavity cooler and the accelerator cavity, a mechanical support connected to the accelerator cavity via at least one endplate and configured for stabilizing the accelerator cavity, and a refrigeration source for providing refrigerant via the cooling connector to the at least one cavity cooler.

Kephart, Robert↗

system2atoms

system2atoms is a suite of models that can simulate the performance of hydrogen infrastructure across multiple scales. Examples of the different scale levels include: 1. System Scale - techno-economic analysis for hydrogen applications, integration of hydrogen infrastructure with the electrical grid, and supply and demand constraints across applications 2. Component Scale - continuous-flow catalyst beds, electrochemical conversion units, gas-phase separators, pumps, compressors, storage tanks, evaporators, heaters, and coolers 3. Material Scale - surface reactions, degradation mechanisms, and catalyst poisoning

Mcnenly, MatthewJ↗

Dual Energy Electron Storage Ring Cooler Design for Relativistic Ion Beams

Collider experiments demand small beam emittances in order to achieve high luminosity. For light particles such as electrons, there exists a natural synchrotron radiation damping resulting in low emittance beams at equilibrium. In the case of heavy particle beams such as proton or ion beams, there is no significant synchrotron radiation damping effect and some cooling mechanism is needed to get to low emittance beams. A dual energy storage ring cooler is a novel concept proposed to cool hadron beams at higher energies. The design consists of two rings: a low energy ring and a high energy ring connected by the energy recovering linac (ERL) that provides the necessary energy difference. The low energy ring has an electron cooler where the cooling interaction takes place between the electron and hadron beams whereas electron beam going through the high energy ring undergoes synchrotron radiation damping. In this document, we present a possible design of a dual energy storage ring-based electron cooler for high energy proton beam cooling suitable for the Electron Ion Collider (EIC) to be built at Brookhaven National laboratory (BNL). A special feature of a dual energy storage ring cooler design is that the electron beam energy in the low energy section must be tuned to match the hadron beam velocity in the cooling section, and the electron beam energy in the high energy section is chosen to provide an adequate synchrotron radiation damping. In addition, the ring optics design is carried out considering chromaticity correction, dynamic aperture, momentum aperture, beam lifetime, radiation damping and the intrabeam scattering effect. Finally, the cooling performance is simulated for 275 GeV proton beams at the top energy of the EIC. In such a collider it is desirable to cool the hadron beams to balance the emittance growth rates due to intra-beam scattering (IBS) to maintain a high luminosity during the collision runs. In such a situation, a dual energy storage ring based cooler could be a practical approach to be used for hadron beam cooling.

Dhital, Bhawin↗

Sandia Cooler

Air-cooled heat exchangers are used to reject excess heat from a concentrated source to the surrounding atmosphere for a variety of mechanical and electrical systems. Advancements in heat exchanger design have been very limited in recent years for most product applications. In support of heat exchanger advancement, Sandia developed the Sandia Cooler.

42 ENGINEERING↗

Waste heat recovery system and control

A waste heat recovery (WHR) system that can be utilized in internal combustion engine systems includes at least two circuits, one having a low pressure working fluid and another having a high pressure working fluid. Each circuit can include heat exchangers to allow the working fluid to absorb heat form one or more heat source fluids associated with the engine. The system can also include an expander configured to receive the working fluid from the at least two circuits, and generating mechanical power. The system also can include a condenser, a sub cooler, and at least one working fluid pump to pump the working fluid in the at least two circuits. The cooling system also includes a controller that can receive temperature and pressure values from various locations in the WHR system and control at least the flow rates of the working fluids in the at least two circuits.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Thermoelectric coolers for high-power-density 3D electronics heat management

Future advancements in three-dimensional (3D) electronics require robust thermal management methodology. Thermoelectric coolers (TECs) are reliable and solid-state heat pumping devices with high cooling capacity that can meet the requirements of emerging 3D microelectronic devices. In this work, we first provide the design of TECs for electronics cooling using a computational model and then experimentally validate the main predictions. Key device parameters such as device thickness, leg density, and contact resistance were studied to understand their influence on the performance of TECs. Our results show that it is possible to achieve high cooling power density through optimization of TE leg height and packing density. Scaling of TECs is shown to provide ultra-high cooling power density.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Separated reactant mix width across diffusion-dominated and hydrodynamically dominated interface mix in inertial confinement fusion implosions

Diffusion-dominated mix in inertial confinement fusion (ICF) is characterized where the majority of the mix occurs in the immediate fuel-shell interface while hydrodynamic-dominated mix pulls shell material from farther away into the central fuel. A thin (150 nm) separated reactants ICF mix platform is highly sensitive to the amount of mix from the first micron of shell-fuel interface. This fine-spatial resolution platform has revealed that material mix in moderate convergence ( CR ∼ 12 ) ICF implosions is dominated by a diffusion mechanism. This technique has now been expanded across a set of OMEGA ICF implosions, observing an increase in mix width and mix amount for cooler, slower, and more compressive implosions. Hydrodynamic simulations require a buoyancy-drag mix model to capture the increasing mix width, suggesting a transition between these two mix mechanisms. Published by the American Physical Society 2024

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Sensitivity analysis for characterizing the impact of HNGD model on the prediction of hydrogen redistribution in Zircaloy cladding using BISON code

Hydrogen in zirconium cladding is able to precipitate into zirconium hydrides which impacts cladding integrity. The Hydride Nucleation-Growth-Dissolution (HNGD) model in the BISON code accounts for the precipitation and dissolution kinetics of hydride in Zircaloy material. This paper presents global sensitivity analyses of the HNGD model aiming to enhance our understanding of the hydride precipitation phenomena by quantifying the variance that key parameters have on the prediction of hydrogen behavior under various environmental conditions. Here, model predictions are compared to experimental data obtained under two different conditions: 1) with uniformly precharged specimens subjected to a linear thermal gradient, and 2) specimens precharged with a cathodically applied hydride rim at one end of the sample and subjected to an asymmetric thermal gradient. The Sobol sensitivity analysis identifies the key parameters in the HNGD model for both types of specimens. For linear temperature cases, the heat of transport dominates the accuracy of predictions when no precipitation occurs at the cold end, while Terminal Solid Solubility for Dissolution (TSSD) is the most important parameter when precipitation occurs. A large variation in the predicted hydrogen concentration profiles is found in the range of high TSSD due to the occurrence of precipitation. For asymmetric temperature cases, the solubility coefficient gives the largest impact on the predicted hydrogen distribution, as it determines the amount of solute hydrogen dissolved from the initially applied hydride rim. A large discrepancy in hydrogen distribution between simulations and experiments exists with the asymmetric specimens because BISON simulations fail to predict the precipitation of hydride at the cooler end. Comparative studies using former and updated models verifies the significant impact of the hydride growth mechanism on predicted hydrogen concentration profiles. In particular, when hydride initially exists, changes in TSSD generate a large variation in the predicted amount of precipitation by hydride growth, giving large uncertainty in predicting the hydrogen distribution over the sample length. The outputs characterize the significant impact of the hydride growth mechanism in the HNGD model on predicting hydrogen behavior, and improve the understanding of the precipitation of hydride in Zircaloy cladding within a range of expected environmental conditions. The analyses indicate work is still needed to improve the hydride solvus models in the BISON code to accurately predict experimentally observed hydride concentrations and distributions.

36 MATERIALS SCIENCE↗

A spectrophotometric analysis of cool white dwarfs in the Gaia and pan-STARRS footprint

We present a spectrophotometric analysis of 2880 cool white dwarfs within 100 pc of the Sun and cooler than T eff ∼ 10 000 K, with grizy Pan-STARRS photometry and Gaia trigonometric parallaxes available. We also supplement our data sets with near-infrared JHK photometry, when available, which is shown to be essential for interpreting the coolest white dwarfs in our sample. We perform a detailed analysis of each individual object using state-of-the-art model atmospheres appropriate for each spectral type, including DA, DC, DQ, DZ, He-rich DA, and the so-called IR-faint white dwarfs. We discuss the temperature and mass distributions of each subsample, as well as revisit the spectral evolution of cool white dwarfs. We find little evidence in our sample for the transformation of a significant fraction of DA stars into He-atmosphere white dwarfs through the process of convective mixing between T eff = 10 000 and ∼6500 K, although the situation changes drastically in the range T eff = 6500–5500 K where the fraction of He-atmosphere white dwarfs reaches ∼45 per cent. However, we also provide strong evidence that at even cooler temperatures (T eff ≲ 5200 K), most DC white dwarfs have H atmospheres. We discuss a possible mechanism to account for this sudden transformation from He- to H-atmosphere white dwarfs involving the onset of crystallization and the occurrence of magnetism. Finally, we also argue that DQ, DZ, and DC white dwarfs may form a more homogeneous population than previously believed.

79 ASTRONOMY AND ASTROPHYSICS↗

High Energy ERLs for Electron Cooling

Future electron-ion colliders such as the recently approved eRHIC collide high-intensity ion beams with high current electron beams. The electron beams take advantage of synchrotron radiation to damp emittances but the ion beams must be cooled via some beam-cooling mechanism, including electron cooling. The ion energies are typically a few hundreds of GeV per nucleon. At this energy, a DC cooler powered by an electrostatic accelerator, the preferred cooling approach on existing machines, is not feasible. An ERL, in principle, can provide the high current and brightness to cool these high-brightness ion beams. The beam quality requirements are much different from previous ERLs designs used for FELs. The cooling bunch must be very long to match the ion beam and the relative energy spread must be very small. Incoherent cooling can be enhanced with magnetized beams, but the magnetization must be maintained throughout the ERL. An alternate cooling mechanism, the so-called Coherent Electron Cooling, is, in principle, stronger and can be done with non-magnetized beams. We will present two applications of an ERL to high energy electron cooling and describe some of the technical challenges that must be overcome to operate such an ERL

Benson, Stephen↗

Field Validation of Thermoelectric Generation System at Holcim Cement Plant in Alpena, Michigan

Executive Summary Project Background The Industrial Technology Validation (ITV) program aims to identify and demonstrate the performance of new, emerging, and underutilized energy-saving technologies in the industrial sector to help inform decisions to help accelerate their commercialization and deployment, as well as to help make industries more competitive. This ITV demonstration evaluated a thermoelectric generation (TEG) technology at a cement plant, aiming to reduce energy demand in the cement industry. A median cement plant consumes 5.73 million British thermal units per ton of clinker production (resulting in 0.838 metric tons of carbon dioxide [CO₂] emissions per ton of clinker) (Boyd and Zhang 2011, EPA 2021), equivalent to approximately 6.9 trillion British thermal units (TBtu) per year in energy consumption at a cement plant producing 3,300 tons of clinker per day.¹ Collaborating with Holcim, Advanced Thermovoltaic Systems (ATS) developed and deployed a pilot-scale thermoelectric power system to efficiently capture and convert waste heat to electricity. The system leverages the Seebeck effect to convert temperature differences on two sides of semiconductor cartridges into electrical power (ScienceDirect, n.d.). This generation is realized with minimal moving parts compared to existing waste-heat-to-generation solutions and allows capture from heat sources with temperatures as low as 150°C. This project aimed to validate a scalable solution applicable for capturing medium-temperature waste heat, including ambient losses from other high-temperature processes, and high-temperature sources less suitable for other waste-heat-to-power solutions. By recovering this otherwise wasted heat, this project intends to validate improvements to overall process efficiency through reduction in purchased electricity, thereby reducing operational costs while enhancing resiliency and competitiveness. Description and Scope This study evaluated the performance of a TEG system from ATS as a solution to convert waste heat into useful power at a Holcim cement plant in Alpena, Michigan. This plant is a fully integrated cement plant that has been operating since 1907. The facility operates continuously (24/7/365) with approximately 250 employees and five long dry kilns, yielding a total production capacity of 7,852 tons of cement per day (EPA 2023). Currently, the Alpena plant uses waste heat boilers to convert waste heat from the exhaust of each kiln into steam, which drives steam turbine generators. The ATS TEG is being evaluated for its potential to supplement the steam turbines by capturing the remaining lower grade heat. This technology is also being considered for other Holcim plants where steam turbines are not a viable option. ATS installed a pilot-scale TEG unit with an array of 582 individual thermoelectric semiconductor cartridges, of which 573 were operational. The cartridges are sandwiched between 48 hot plates and 49 cold plates. Each cartridge is designed to generate 20 watts (W) of gross power at a hot-side temperature of 240°C and cold-side temperature of 20°C. As such, the total gross generation capacity of the installed system is 11.5 kilowatts (kW) at design conditions. The system configuration for the evaluation was designed to prioritize convenience of installation and minimize disruption to production at the site, while ensuring that the heat required can be obtained for evaluating the TEG system at various operational conditions. To accomplish this, a portion of the steam supplied to Alpena’s steam turbine generation system was diverted to be used as the heat source for the TEG system, while water was supplied to the cold side of the system from nearby Lake Huron. This configuration was designed for the evaluation of the pilot-scale system to assess the performance at different conditions. A commercial-scale system will likely vary from the pilot system depending on typical configurations, including both scale and application. Future commercial applications of the ATS system would involve integrating the system into the exhaust from kiln preheaters, clinker coolers, or radiant heat capture from kiln shells for the heat source. For the cold source, a range of cooling solutions can be considered, including a mechanical cooling system, depending on the location and the application. To increase the generation capacity for commercial applications, the technology provider is working toward developing a commercial-scale TEG system, which would combine multiple TEG units (each similar in design to the pilot system) together. The scope of this evaluation includes the pilot-scale TEG system and all impacted equipment including pumps, controllers, and power handling equipment. Study Objectives The evaluation's goal was to assess the potential of the ATS TEG system to generate useful electrical power by capturing waste heat from cement production kilns. The objectives of this study are to evaluate and verify the following claims made by ATS regarding the pilot-scale system installed at the Holcim Alpena plant. The following design parameters and claims are also outlined in Table ES- 1 and Table ES- 2: • Gross Power: The thermoelectric system converts heat into power to create gross power, the total measured power generated by the system. The 573 active cartridge pilot-scale system is expected to generate 11.5 kW of gross power at the designed hot-side temperature of 240°C and cold-side temperature of 20°C. Power production is dependent on the temperature difference between the heat source (ultimately from the waste heat) and cold temperature supply source. • Net Power: The net power is the total usable power provided to the site by the TEG system after deducting parasitic power loads from the gross generated power. Supplementary equipment is required to operate the TEG system including pumps, controllers, and, in certain anticipated applications, mechanical cooling, which introduce parasitic loads to system operation. After deducting the parasitic loads from the gross power generation, ATS anticipates achieving a net power generation of 7.5 kW from the pilot-scale system. • Thermal Efficiency: The thermal efficiency is the percent of the total heat transferred to the TEG system that is converted to gross power. Historically, TEGs have a thermal efficiency of 2%–5% (DOE 2008). Prior industrial-scale TEG systems, such as the E1 TEG offered by Alphabet Energy, operated at an efficiency of 2.5% (Lamonica, 2014). ATS anticipates achieving an average efficiency of 4.8% or higher in converting heat energy to usable electricity. • Cartridge Performance: The TEG system comprises 573 active individual semiconductor cartridges, each of which generates a portion of the total power. Cartridge optimization and selection is an important design consideration for potential future TEG system design performance. Therefore, understanding the distribution of gross power and efficiency within the pilot system is vital to understanding what is achievable. At a design hot-side temperature of 240°C and cold-side temperature of 20°C, ATS anticipates a cartridge performance of 20 W of gross power per cartridge at an efficiency of 4.8% per cartridge. In addition to evaluating the claimed performance of the TEG pilot-scale unit, the study estimated the potential annual impacts of a scaled-up commercial system used to capture kiln waste heat over annual operations. The evaluation estimated the gross and net annual electric generation achievable by capturing heat from the two proposed tap-in points: the kiln exhaust and the clinker cooler exhaust; see Section 2.1 for details. Two use cases were examined: • Holcim Alpena: The Holcim Alpena site consists of long dry kilns with superheater boilers, which differs from the rest of Holcim’s cement plant portfolio and results in lower waste heat temperatures. The study estimates gross and net annual generation using the superheater boiler exhaust and clinker cooler exhaust, based on 2023 operational data. • Typical Installation: Common cement plants have preheater kilns with higher exhaust temperatures than Holcim Alpena across a range of production rates. The study estimates gross and net annual generation using the preheater exhaust and clinker cooler exhaust, with a sensitivity analysis to account for the typical range of preheater exhaust temperatures, clinker cooler exhaust temperatures, and clinker production rates. Methodology The evaluation methodology followed a measurement and verification (M&V) strategy based on the International Performance Measurement and Verification Protocol Option B through comprehensive measurements and analyses of the affected systems. Evaluation data was collected from March 9 to March 11, 2024, the test period of the pilot TEG system. During the test period, in coordination with the ITV team, the ATS team adjusted system operations to capture the range of variability expected for each of the variables pertinent to performance of the system. The methodology consisted of two parts: evaluating the performance of the pilot unit's TEG system and estimating the annual TEG impact in terms of gross and net power based on a given waste heat profile. First, the evaluation of the thermoelectric generation performance of the pilot unit relative to the claims was performed by analyzing the collected test data. Gross power of the pilot TEG system was directly measured. Net power was determined by deducting the measured parasitic power from the gross power. The gross power generation was compared to heat transferred to the system by the working fluid (which was heated by steam generated from the kiln waste heat) to calculate the thermal efficiency achieved by the system. Performance of individual semiconductor cartridges within the pilot array was also assessed in terms of measured gross cartridge power and calculated cartridge thermal efficiency. The second part of the evaluation estimated the annual TEG impacts in terms of gross power and net power (calculated from the difference between gross power and parasitic power). This analysis comprised development of mathematical regression models for gross power and parasitic power, with assessment of each model’s goodness-of-fit characteristics to ensure satisfaction of statistical requirements. The models predicted the gross power generation, the parasitic load based on the temperature difference between the hot working fluid and the cold-side fluid (cold water from Lake Huron) entering the system, the volumetric flow rate of the cold-side fluid at the inlet, and the volumetric flow rate of the hot working fluid at the inlet. The annual impact analysis considered a theoretical commercial-scale system sized to capture the available waste heat at a cement plant, consisting of linked pilot-scale units that receive heat from a theoretical gas-to-working-fluid heat exchanger. To estimate annual impacts at the Alpena plant, the gross power and parasitic power regression models were applied to the arrays in the theoretical commercial-scale system. The heat supplied to the unit was calculated based on the kiln run time, annual production, kiln exhaust waste heat, and clinker cooler waste heat derived from 2023 Holcim Alpena kiln operational data. Net power impacts were calculated by deducting the resulting parasitic power from the estimated gross power. Inputs for the model were generated from a combination of hourly data, assumed design considerations for TEG system scale-up from the pilot-scale unit, and assumptions regarding TEG system operations. This analysis was then used as the basis for estimating annual impacts of typical TEG installation at cement plants, by applying sensitivity analyses to key kiln operational characteristics including kiln preheater exhaust temperatures, cooler clinker exhaust temperatures, and plant daily production rates across a range of expected values. Project Results/Findings Table ES- 2 and Table ES- 2 provide a summary of the operating conditions and evaluation results compared to the stated claims from the technology provider. Key takeaways include: • Gross Power: The peak gross power achieved during the testing period was 10.0 kW, compared to the 11.5 kW expected for 573 active cartridges. The claimed gross power was associated with a target hot side of 240°C; however, the system only received a maximum hot-side mean plate temperature of 212°C during the testing period. • Net Power: The pilot-scale unit exceeded the claims for net power, achieving a peak of 7.7 kW net compared to a claim of 7.5 kW. One factor contributing to the higher achieved net power is the relatively high water pressure available through Lake Huron. The pilot TEG system did not require cold-side pumps during the test, whereas most installations would. This reduced the parasitic loads on the system, ultimately contributing to higher net power relative to the gross power. • Thermal Efficiency: The pilot-scale unit outperformed the claimed efficiency, achieving a peak system efficiency of 5.0% thermal efficiency compared to the stated 4.8%. • Cartridge Performance: To compare cartridge performance against claims, the study focused on the third day of testing, which aimed for conditions closest to the design specifications, with a hot side of 240°C and cold-side exit temperature of 6.4°–30°C. On this day, the mean gross power observed in the cartridges within the TEG array was 18.1 W/cartridge, and the peak performance was 34.7 W/cartridge. The estimated mean cartridge efficiency was 5.2%, and the estimated efficiency at peak gross cartridge power was 10%. The regression models developed for gross power generation and parasitic loads were used to estimate the generation impact for given heat input to the TEG from the working fluid (captured from the waste heat) and from the cold loop (Lake Huron) on an hourly basis for a year of operation. Based on this analysis, installation of a commercial-scale TEG system at the Holcim cement plant in Alpena, Michigan, with a waste heat exchanger of 0.85 effectiveness, would generate up to 391 kW of net power, translating to between 920,000 and 1,800,000 kilowatt-hours (kWh) in net electricity per year. Based on typical grid emissions for Alpena, this would avoid estimated net emissions by 752 metric tons of CO₂ annually.² The sensitivity analysis estimated that typical TEG system installations at cement plants could generate an average of 56–1,040 kW of net power, or between 488,000 and 9,110,000 kWh of net energy. This generation potential is most significantly affected by plant production rates and also influenced by preheater and clinker cooler exhaust temperatures. Applying the national average emission rate, typical commercial-scale installations at Holcim plants are projected to avoid between 182 and 3,401 metric tons of CO₂ annually per site. Table ES- 3 shows a summary of the estimated annual impacts.³ While parasitic loads are significant and vary by application, this analysis assumed the use of heating loop pumps and access to Lake Huron as a cold sink. This setup assumed no need for cooling loop pumps due to the available water pressure at the test site. Applications that require cooling towers or additional equipment are likely to experience higher parasitic loads. Therefore, the study’s estimates are most applicable to scenarios with similar parasitic load configurations—namely, access to a high-pressure cold sink. Applicability to other locations may be limited, as differing conditions could necessitate additional pumps and cooling systems, potentially impacting performance significantly.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Catastrophic Cooling Instability in Optically Thin Plasmas

The solar corona is the prototypical example of a low-density environment heated to high temperatures by external sources. The plasma cools radiatively, and because it is optically thin to this radiation, it becomes possible to model the density, velocity, and temperature structure of the system by modifying the MHD equations to include an energy source term that approximates the local heating and cooling rates. The solutions can be highly inhomogeneous and even multiphase because the well-known linear instability associated with this source term, thermal instability, leads to a catastrophic heating and cooling of the plasma in the nonlinear regime. Here we show that there is a separate, much simpler linear instability accompanying this source term that can rival thermal instability in dynamical importance. The stability criterion is the isochoric one identified by Parker (1953), and we demonstrate that cooling functions derived from collisional ionization equilibrium are highly prone to violating this criterion. If catastrophic cooling instability can act locally in global simulations, then it is an alternative mechanism for forming condensations, and due to its nonequilibrium character, it may be relevant to explaining a host of phenomena associated with the production of cooler gas in hot, low density plasmas.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

Upper bounds for 21st-century surface air temperatures in the Western United States

The last decade has seen a large number of severe heatwaves that were unprecedented in the observational record, highlighting challenges associated with observationally-based statistical quantification of the likelihood and magnitude of future extreme temperatures. An alternative to such probabilistic assessments is identification of upper bounds that quantify the hottest surface air temperatures that can possibly be achieved by the end of the 21st century. Theory, simulations, and observational analyses support the existence of a finite upper bound for surface air temperature; however, estimates for future upper-bound values that are realistic and usable for planning remain unavailable. Here, we combine atmospheric theory with large ensembles of dynamically downscaled projections to estimate historical and end-of-century upper bounds for surface air temperatures. A number of physical mechanisms can influence upper bounds, and at the end of the 21st century, estimates based on mechanisms that yield more moderate upper-bounds produce values around 60∘C for much of the Western United States and in excess of 80∘C for the hottest parts of the domain. Even cooler high-altitude locations have end-of-century upper bounds over 50∘C. Although these upper-bound estimates might seem implausibly large, increases in the upper bounds over the 21st century are similar to increases in dynamically downscaled peak surface temperatures after adjusting those downscaled temperatures to eliminate the possibly biased model trends in surface specific humidity. While upper bound estimates are high relative to historical observations, they nonetheless suggest that heatwave intensity risk is bounded, with uncertainty dominated by projections of surface and upper-level humidity.

Risser, Mark D↗

Velocity structure functions in multiphase turbulence: interpreting kinematics of Hα filaments in cool-core clusters

ABSTRACT The central regions of cool-core galaxy clusters harbour multiphase gas, with gas temperatures ranging from $10$ to $10^7\, \mathrm{K}$. Feedback from active galactic nuclei jets prevents the gas from undergoing a catastrophic cooling flow. However, the exact mechanism of this feedback energy input is unknown, mainly due to the lack of velocity measurements of the hot-phase gas. However, recent observations have measured the velocity structure functions (VSFs) of the cooler molecular (${\sim} 10\, \mathrm{K}$) and Hα filaments (${\sim} 10^4\, \mathrm{K}$) and used them to indirectly estimate the motions of the hot phase. In the first part of this study, we conduct high-resolution (3843–15363 resolution elements) simulations of homogeneous isotropic subsonic turbulence, without radiative cooling. We analyse the second-order velocity structure functions (VSF2) in these simulations and study the effects of varying spatial resolution, the introduction of magnetic fields, and the effect of projection along the line of sight (LOS) on it. In the second part of the study, we analyse high-resolution (7683 resolution elements) idealized simulations of multiphase turbulence in the intracluster medium from the companion study Mohapatra et al. We compare the VSF2 for both the hot ($T\sim 10^7\, \mathrm{K}$) and cold ($T\sim 10^4\, \mathrm{K}$) phases and find that their amplitude depends on the density contrast between the phases. They have similar scaling with separation, but introducing magnetic fields steepens the VSF2 of only the cold phase. We also find that projection along the LOS steepens the VSF2 for the hot phase and mostly flattens it for the cold phase.

Mohapatra, Rajsekhar (ORCID:0000000216007552)↗

ENG 572 Final Report

Thermo-electric coolers (TECs) provide an essential function in many high-powered applications by diverting heat away from a temperature-sensitive load. This summer I have worked with Sandia National Laboratories in exploring the failure mechanisms behind said devices. I have been tasked with determining a plan of action for two TECs manufactured by two different companies labeled A and B respectively. Prior to my involvement in the project, the former has displayed failures during normal operation within its packaging. The latter was subsequently chosen to resolve these issues. Thermal cycling between the extreme expected operating temperatures (-40°C to 80°C) was applied to 5 unmounted TECAs over a period of 5 hours with 1-hour soaks at each extreme. The unmounted TECBs are currently undergoing the same process, and the task is expected to be completed over the next few weeks. The results of the TECA characterization have indicated no failure has occurred, which indicates that failure will need to be induced through either higher temperature extremes or additional mechanical stress.

47 OTHER INSTRUMENTATION↗