Search NASA⌕ Search

SEARCH · Search NASA

Results for “mechanical devices”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

LANSCE wire scanning diagnostics device mechanical design

The Los Alamos Neutron Science Center (LANSCE) is one of the major experimental science facilities at the Los Alamos National Laboratory (LANL). The core of LANSCE's work lies in the operation of a powerful linear accelerator, which accelerates protons up to 84% the speed oflight. These protons are used for a variety of purposes, including materials testing, weapons research and isotopes production. To assist in guiding the proton beam, a series of over one hundred wire scanners are used to measure the beam profile at various locations along the half-mile length of the particle accelerator. A wire scanner is an electro-mechanical device that moves a set of wires through a particle beam and measures the secondary emissions from the resulting beam-wire interaction to obtain beam intensity information. When supplemented with data from a position sensor, this information is used to determine the cross-sectional profile of the beam. This measurement allows beam operators to adjust parameters such as acceleration, beam steering, and focus to ensure that the beam reaches its destination as effectively as possible. Some of the current wire scanners are nearly forty years old and are becoming obsolete. The problem with current wire scanners comes in the difficulty of maintenance and reliability. The designs of these wire scanners vary making it difficult to keep spare parts that would work on all designs. Also many of the components are custom built or out-dated technology and are no longer in production.

43 PARTICLE ACCELERATORS↗

Mechanical Device Traces Parabolas

Mechanical device simplifies generation of parabolas of various focal lengths. Based on fundamental geometrical construction of parabola. Constancy of critical total distance enforced by maintaining cable in tension. Applications of device include design of paraboloidal antennas, approximating catenaries on drawings of powerlines or long-wire antennas, and general tracing of parabolas on drawings.

Soper, Terry A.↗

Mechanical devices: A compilation

A collection of new technology items that should be of interest to mechanical engineers, machinists, and others who design or work with mechanical devices was described. Section 1 contains articles on several new or modified tools, Section 2 describes a number of specialized mechanical systems, and the last section is devoted to valves, bearings, and other parts that might be used with larger systems. The last patent information available is also given.

Source record↗

Determining Functional Reliability of Pyrotechnic Mechanical Devices

This paper describes a new approach for evaluating mechanical performance and predicting the mechanical functional reliability of pyrotechnic devices. Not included are other possible failure modes, such as the initiation of the pyrotechnic energy source. The requirement of hundreds or thousands of consecutive, successful tests on identical components for reliability predictions, using the generally accepted go/no-go statistical approach routinely ignores physics of failure. The approach described in this paper begins with measuring, understanding and controlling mechanical performance variables. Then, the energy required to accomplish the function is compared to that delivered by the pyrotechnic energy source to determine mechanical functional margin. Finally, the data collected in establishing functional margin is analyzed to predict mechanical functional reliability, using small-sample statistics. A careful application of this approach can provide considerable cost improvements and understanding over that of go/no-go statistics. Performance and the effects of variables can be defined, and reliability predictions can be made by evaluating 20 or fewer units. The application of this approach to a pin puller used on a successful NASA mission is provided as an example.

Bement, Laurence J.↗

Mechanical Devices Readiness FY04.0402.3

This project funded production process and tooling improvements to meet and sustain rate production for the W76-1 mechanism assemblies. Techniques were developed to allow evaluation and disposition of sealed stronglinks that resulted in prevention of the scrapping of numerous stronglinks and firesets. Improved processes and tooling allowed D-Test rates to be reduced in favor of E-Test, thus saving millions of dollars over the life of the program. Future system mechanisms will likely be smaller with tighter toleranced parts that will require improved inspection equipment and techniques. During the latter phase of this project, a method of improving inspection was developed that will have benefits for existing and future system mechanical assemblies.

42 ENGINEERING↗

Lansce Wire Scanning Diagnostics Device Mechanical Design

The Accelerator Operations & Technology Division at Los Alamos National Laboratory operates a linear particle accelerator which utilizes 110 wire scanning diagnostics devices to gain position and intensity information of the proton beam. In the upcoming LANSCE improvements, 51 of these wire scanners are to be replaced with a new design, up-to-date technology and off-the-shelf components. This document outlines the requirements for the mechanical design of the LANSCE wire scanner and presents the recently developed linac wire scanner prototype. Additionally, this document presents the design modifications that have been implemented into the fabrication and assembly of this first linac wire scanner prototype. Also, this document will present the design for the second, third, and fourth wire scanner prototypes being developed. Prototypes 2 and 3 belong to a different section of the particle accelerator and therefore have slightly different design specifications. Prototype 4 is a modification of a previously used wire scanner in our facility. Lastly, the paper concludes with a plan for future work on the wire scanner development.

Accelerator Design, Technology, and Operations↗

Micro-opto-mechanical devices and systems using epitaxial lift off

The integration of high quality, single crystal thin film gallium arsenide (GaAs) and indium phosphide (InP) based photonic and electronic materials and devices with host microstructures fabricated from materials such as silicon (Si), glass, and polymers will enable the fabrication of the next generation of micro-opto-mechanical systems (MOMS) and optoelectronic integrated circuits. Thin film semiconductor devices deposited onto arbitrary host substrates and structures create hybrid (more than one material) near-monolithic integrated systems which can be interconnected electrically using standard inexpensive microfabrication techniques such as vacuum metallization and photolithography. These integrated systems take advantage of the optical and electronic properties of compound semiconductor devices while still using host substrate materials such as silicon, polysilicon, glass and polymers in the microstructures. This type of materials optimization for specific tasks creates higher performance systems than those systems which must use trade-offs in device performance to integrate all of the function in a single material system. The low weight of these thin film devices also makes them attractive for integration with micromechanical devices which may have difficulty supporting and translating the full weight of a standard device. These thin film devices and integrated systems will be attractive for applications, however, only when the development of low cost, high yield fabrication and integration techniques makes their use economically feasible. In this paper, we discuss methods for alignment, selective deposition, and interconnection of thin film epitaxial GaAs and InP based devices onto host substrates and host microstructures.

Camperi-Ginestet, C.↗

Mechanical Devices Readiness FY04.0402.1

This Advanced Design and Production Technologies (ADAPT) project funded production process and tooling improvements to meet and sustain rate production for the program mechanism assemblies. Techniques were developed to allow evaluation and rework of sealed mechanisms that will result in prevention of the scrapping of future mechanisms. Future system mechanisms will likely be smaller with tighter tolerance parts that will require improved inspection equipment and techniques. During the latter phase of this project, the ISL (Intent Stronglink) PRT (Product Realization Team) developed designs and manufacturing processes at Sandia and at multiple KCP (Kansas City Plant) vendors, to produce glass ceramic headers to replace the brazed ceramic headers in the ISL. This achievement will result in significant production costs savings (unit cost and product scrap due to leaking headers).

42 ENGINEERING↗

Laser-actuated mechanical device

Actuator is portable and can be used in high-temperature (over 500 C) environments by incorporating tungsten metal film and quartz window. Actuator can be triggered when it is not directly in laser beam path by utilizing fiber optics. It is advantageous for remotely switching ultra-high voltage systems.

Murphy, A. J.↗

Detection of bearing failure in mechanical devices using neural networks

We present a novel time-domain method for the detection of faulty bearings that has direct applicability to monitoring the health of the turbo pumps on the Space Shuttle Main Engine. A feed-forward neural network was trained to detect modelled roller bearing faults on the basis of the periodicity of impact pulse trains. The network's performance was dependent upon the number of pulses in the network's input window and the signal-to-noise ratio of the input signal. To test the model's validity, we fit the model's parameters to an actual vibration signal generated by a faulty roller element bearing and applied the network trained on this model to detect faults in actual vibration data. When this network was tested on the actual vibration data, it correctly identified the vibration signal as a fault condition 76 percent of the time.

Burne, Richard A.↗

A Mechanical Device for Illustrating Airplane Stability

An instrument is described which will illustrate completely in a qualitative sense the longitudinal stability characteristics of an airplane. The instrument is primarily of use for the lecture room, but it is hoped that ultimately it will be possible to obtain quantitative results from it.

Norton, F H↗

Study of Control Rod Device Mechanism Missile Impact on Protection Plate

The flying of missile will severely jeopardize the structural integrity in control rod ejection accident. In order to analyze the strength of a new type of shield plate under control rod drive mechanism (CRDM) impact, this article develops the simulation model and conducts the nonlinear response analysis of the missile under 4 cases. In addition, the stress analysis and evaluation of protection shield plate at the most dangerous case are performed. The computed results are validated via empirical formula. The motion analysis of CRDM missile indicates that the fracture at trapezoid thread place is more dangerous than the fracture occurs at cold fitting place. Moreover, the impact at the rim of the shield by the CRDM rod travelling housing is more dangerous than at the center. Therefore, the fracture at trapezoid thread place as well as the shield plate rim under impact should be examined when performing the stress evaluation of the shield plate. Under this circumstance, the maximum stress intensity of the shield plate will exceed the yielding stress and thereby local plasticity will occur. Strain analysis shows that compared with the extension ratio at structural failure, the computed strain still has quite amount of margin to ensure the shield plate will not be penetrated. Hence, this new type of the protection shield plate is capable to prevent the damage of other components by the flying of CRDM missile.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Remote weighing device

Mechanical device for accurate measurement of weight and changes in weight is presented. Diagram of mechanical equipment is illustrated. Construction of system is described and method of operation is analyzed.

Valinsky, J. P.↗