Mechanotransduction in bone: osteoblasts are more responsive to fluid forces than mechanical strain

Mechanical force applied to bone produces two localized mechanical signals on the cell: deformation of the extracellular matrix (substrate strain) and extracellular fluid flow. To study the effects of these stimuli on osteoblasts, MC3T3-E1 cells were grown on type I collagen-coated plastic plates and subjected to four-point bending. This technique produces uniform levels of physiological strain and fluid forces on the cells. Each of these parameters can be varied independently. Osteopontin (OPN) mRNA expression was used to assess the anabolic response of MC3T3-E1 cells. When fluid forces were low, neither strain magnitude nor strain rate was correlated with OPN expression. However, higher-magnitude fluid forces significantly increased OPN message levels independently of the strain magnitude or rate. These data indicate that fluid forces, and not mechanical stretch, influence OPN expression in osteoblasts and suggest that fluid forces induced by extracellular fluid flow within the bone matrix may play an important role in bone formation in response to mechanical loading.

Non-NASA Center↗

Estrogen regulates the rate of bone turnover but bone balance in ovariectomized rats is modulated by prevailing mechanical strain

Estrogen deficiency induced bone loss is associated with increased bone turnover in rats and humans. The respective roles of increased bone turnover and altered balance between bone formation and bone resorption in mediating estrogen deficiency-induced cancellous bone loss was investigated in ovariectomized rats. Ovariectomy resulted in increased bone turnover in the distal femur. However, cancellous bone was preferentially lost in the metaphysis, a site that normally experiences low strain energy. No bone loss was observed in the epiphysis, a site experiencing higher strain energy. The role of mechanical strain in maintaining bone balance was investigated by altering the strain history. Mechanical strain was increased and decreased in long bones of ovariectomized rats by treadmill exercise and functional unloading, respectively. Functional unloading was achieved during orbital spaceflight and following unilateral sciatic neurotomy. Increasing mechanical loading reduced bone loss in the metaphysis. In contrast, decreasing loading accentuated bone loss in the metaphysis and resulted in bone loss in the epiphysis. Finally, administration of estrogen to ovariectomized rats reduced bone loss in the unloaded and prevented loss in the loaded limb following unilateral sciatic neurotomy in part by reducing indices of bone turnover. These results suggest that estrogen regulates the rate of bone turnover, but the overall balance between bone formation and bone resorption is influenced by prevailing levels of mechanical strain.

STS-62 Shuttle Project↗

Mechanical strain isolator mount

Certain devices such as optical instruments must preserve their alignmental integrity while being subjected to mechanical strain. A mechanical strain isolator mount is provided to preserve the alignmental integrity of an alignment sensitive instrument. An alignment sensitive instrument is mounted on a rectangular base. Flexural legs are connected at their proximal ends to the rectangular base. Flexural legs are also spaced parallel to the sides. Mounting pads are connected to the legs at the distal end and the mechanical strain isolator mount is attached to the substrate by means of threaded bolts. When a mounting pad and its respective leg is subjected to lateral strain in either the X or Y direction via the substrate, the respective leg relieves the strain by bending in the direction of the strain. An axial strain on a mounting pad in the Z direction is relieved by a rotational motion of the legs in the direction of the strain. When the substrate is stress free, the flexural legs return to their original condition and thus preserve the original alignment integrity of the alignment sensitive instrument.

James, Gordon E.↗

Transduction of mechanical strain in bone

One physiologic consequence of extended periods of weightlessness is the rapid loss of bone mass associated with skeletal unloading. Conversely, mechanical loading has been shown to increase bone formation and stimulate osteoblastic function. The mechanisms underlying mechanotransduction, or how the osteoblast senses and converts biophysical stimuli into cellular responses has yet to be determined. For non-innervated mechanosensitive cells like the osteoblast, mechanotransduction can be divided into four distinct phases: 1) mechanocoupling, or the characteristics of the mechanical force applied to the osteoblast, 2) biochemical coupling, or the mechanism through which mechanical strain is transduced into a cellular biochemical signal, 3) transmission of signal from sensor to effector cell and 4) the effector cell response. This review examines the characteristics of the mechanical strain encountered by osteoblasts, possible biochemical coupling mechanisms, and how the osteoblast responds to mechanical strain. Differences in osteoblastic responses to mechanical strain are discussed in relation to the types of strain encountered and the possible transduction pathways involved.

Review, Tutorial↗

Human osteoblast-like cells respond to mechanical strain with increased bone matrix protein production independent of hormonal regulation

Exposure of osteosarcoma cell lines to chronic intermittent strain increases the activity of mechano-sensitive cation (SA-cat) channels. The impact of mechano-transduction on osteoblast function has not been well studied. We analyzed the expression and production of bone matrix proteins in human osteoblast-like osteosarcoma cells, OHS-4, in response to chronic intermittent mechanical strain. The OHS-4 cells exhibit type I collagen production, 1,25-Dihydroxyvitamin D-inducible osteocalcin, and mineralization of the extracellular matrix. The matrix protein message level was determined from total RNA isolated from cells exposed to 1-4 days of chronic intermittent strain. Northern analysis for type I collagen indicated that strain increased collagen message after 48 h. Immunofluorescent labeling of type I collagen demonstrated that secretion was also enhanced with mechanical strain. Osteopontin message levels were increased several-fold by the application of mechanical load in the absence of vitamin D, and the two stimuli together produced an additive effect. Osteocalcin secretion was also increased with cyclic strain. Osteocalcin levels were not detectable in vitamin D-untreated control cells. However, after 4 days of induced load, significant levels of osteocalcin were observed in the medium. With vitamin D present, osteocalcin levels were 4 times higher in the medium of strained cells compared to nonstrained controls. We conclude that mechanical strain of osteoblast-like cells is sufficient to increase the transcription and secretion of matrix proteins via mechano-transduction without hormonal induction.

NASA Discipline Number 40-40↗

Real-Time Modulation of Hydrogen Evolution Activity of Graphene Electrodes Using Mechanical Strain

This paper reports the effect of mechanically applied elastic strain on the hydrogen evolution reaction (HER) activity of graphene under acidic conditions. Here, applied tensile strain of 0.2% on a graphene electrode is shown to lead to a 1–3% increase of HER current. Tensile strain increases HER activity while compressive strain decreases it. Density functional theory (DFT) calculations using a periodic graphene slab model show increasing in the adsorption energy of H atom with growing tensile strain, leading to a corresponding enhancement of current density in HER, similar to that observed experimentally.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Thermal Conductivity of Graphene Coated Copper Under Uniaxial Tensile Mechanical Strain

Graphene continues to demonstrate promise as a highly effective barrier coating, even at only one atom thick. The thermal properties of this coating are also promising to allow diffusion of heat across the surface, as the isolated graphene is an intrinsically good thermal conductor, yet this and its behavior under mechanical deformation has been less extensively studied. This report demonstrates that the in-plane thermal conductivity and interfacial thermal conductance of graphene coatings on copper are affected by mechanical strain. By inducing a strain in the copper substrate, the Raman-active 2D peak exhibits a change in position as well as a change in laser power dependence as the copper substrate is uniaxially elongated to a maximum of 0.5%. Non-linear trends in thermal conductivity are observed with tensile strain in samples with differing strain transfer rates from the substrate, indicating the close correlation between intrinsic thermal conduction and interfacial properties in atomically thin coatings transferred onto metals.

36 MATERIALS SCIENCE↗

A novel culture morphology resulting from applied mechanical strain

To demonstrate that cells both perceive and respond to external force, a strain/relaxation regimen was applied to normal human fetal and aged dermal fibroblasts cultured as monolayers on flexible membranes. The precisely controlled protocol of stretch (20% elongation of the culture membrane) at 6.67 cycles/min caused a progressive change in the monolayers, such that the original randomly distributed pattern of cells became a symmetric, radial distribution as the cell bodies aligned parallel to the applied force. High cell density interfered with the success of re-alignment in the fetal cell cultures observed, which may reflect a preference in this cell strain for cell-cell over cell-matrix contacts. The chronologically aged cells observed did not demonstrate this feature, aligning efficiently at all seeding densities examined. The role of microfilaments in force perception and transmission was investigated through the addition of cytochalasin D in graded doses. Both intercellular interactions and cytoskeletal integrity mediate the morphological response to mechanical strain.

NASA Discipline Cell Biology↗

Oxygen Evolution on Mechanically Strained TiO2/NiTi: Implications of Compositional Heterogeneity at (Photo)Electrocatalytic Interfaces

The adsorption and activation energetics underpinning small molecule conversion on heterogeneous (photo)electrocatalysts are intrinsically tied to catalyst surface properties. Absent compositional characterization techniques with sufficient interface sensitivity, however, (photo)electrochemical performance can be misinterpreted in the context of bulk or near-surface material properties. Here we provide a fundamental investigation of the convoluting role of near-surface compositional heterogeneity in the interpretation of (photo)electrochemical alkaline oxygen evolution reaction (OER) activity, highlighting challenges in correlating composition measured by surface- and near-surface-sensitive probes. TiO2 thin films grown by air-annealing the superelastic alloy Nitinol (TiO2/NiTi) crack under tensile mechanical strain, increasing the number of electrochemically active Ni sites (Ni site density) that are probed via voltammetric features corresponding to Ni3+/Ni2+ redox events. (Photo)electrochemical OER kinetics trend with Ni site density, with overpotentials and Tafel slopes decreasing for Ni site densities < 1013 Ni/cm2geo and asymptotically approaching the performance of the base NiTi substrate for Ni site densities > 1013 Ni/cm2geo. Photoelectrochemical fill factors follow similar Ni site density dependent trends. When probing unstrained TiO2/NiTi, Ni site densities are two orders of magnitude higher when comparing near-surface-sensitive techniques (e.g., X-ray photoelectron spectroscopy (XPS), time of flight secondary ion mass spectrometry (TOF-SIMS), and scanning transmission electron microscopy-energy dispersive X-ray spectroscopy (STEM-EDS)) to surface-sensitive electrochemical measurements. This result highlights the challenge of correlating kinetic performance with intrinsic surface properties of electrochemical interfaces in the presence of near-surface compositional heterogeneity. Further, it reinforces the importance of fundamental investigations of surfaces with well-controlled composition and structure and the need for physically grounded and self-consistent interpretation of multiple near-surface characterization techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

High temperature, low cycle fatigue of copper-base alloys in argon. Part 3: Zirconium-copper; thermal-mechanical strain cycling, hold-time and notch fatigue results

The low-cycle fatigue characteristics of smooth bar and notched bar specimens (hourglass shape) of zirconium-copper, 1/2 Hard, material (R-2 Series) were evaluated at room temperature in axial strain control. Over the fatigue life range from about 300 to 3000 cycles the ratio of fatigue life for smooth bar to fatigue life for notched bar remained constant at a value of about 6.0. Some additional hold-time data for the R-2 alloy tested in argon at 538 C are reported. An analysis of the relaxation data obtained in these hold-time tests is also reported and it is shown that these data yield a fairly consistent correlation in terms of instantaneous stress rate divided by instantaneous stress. Two thermal-mechanical strain cycling tests were also performed using a cyclic frequency of 4.5 cycles per hour and a temperature cycling interval from 260 to 538 C. The fatigue life values in these tests were noticeably lower than that observed in isothermal tests at 538 C.

Conway, J. B.↗

Thermal-Fatigue Crack-Growth Characteristics and Mechanical Strain Cycling Behavior of A-286 Discaloy, and 16-25-6 Austenitic Steels

Thermal-fatigue crack-growth characteristics of notched- and unnotched-disk specimens of A-286, Discaloy, hot-cold worked 16-25-6, and overaged 16-25-6 were experimentally studied. Separately controlled variables were total strain range (0.0043 to 0.0079 in./in.), maximum cycle temperature (1300 and 1100 F), and hold time at maximum temperature (O and 5 min). A limited number of mechanical, push-pull, constant-strain cycle tests at room temperature were made using notched and un-notched bars of the same materials. In these tests the number of cycles to failure as well as the variation of load change with accumulated cycles was measured, and the effects of mean stress were observed. Constant-strain-range mechanical-fatigue tests at room temperature revealed notched-bar fatigue life to be strongly influenced by mean stress. For a specific strain range, the longest fatigue life was always found to be associated with the least-tensile (or most compressive) mean stress. By defining thermal-fatigue life as the number of cycles required to produce a crack area of 6000 square mils, the relative thermal-fatigue resistances of the test materials were established. Notched-disk specimens of A-286 and Discaloy steels exhibited longer fatigue lives than either hot-cold worked or overaged 16-25-6. On the other hand, unnotched-disk specimens of Discaloy and hot-cold worked 16-25-6 had longer lives than A-286 and overaged 16-25-6. Separation of the crack-growth data into microstage and macrostage periods revealed that the macrostage period accounted for the greatest part of the difference among materials when tested in the notched configuration, while the microstage was largely responsible for the differences encountered in unnotched disks.

Smith, Robert W.↗

Mechanotransduction and the functional response of bone to mechanical strain

Mechanotransduction plays a crucial role in the physiology of many tissues including bone. Mechanical loading can inhibit bone resorption and increase bone formation in vivo. In bone, the process of mechanotransduction can be divided into four distinct steps: (1) mechanocoupling, (2) biochemical coupling, (3) transmission of signal, and (4) effector cell response. In mechanocoupling, mechanical loads in vivo cause deformations in bone that stretch bone cells within and lining the bone matrix and create fluid movement within the canaliculae of bone. Dynamic loading, which is associated with extracellular fluid flow and the creation of streaming potentials within bone, is most effective for stimulating new bone formation in vivo. Bone cells in vitro are stimulated to produce second messengers when exposed to fluid flow or mechanical stretch. In biochemical coupling, the possible mechanisms for the coupling of cell-level mechanical signals into intracellular biochemical signals include force transduction through the integrin-cytoskeleton-nuclear matrix structure, stretch-activated cation channels within the cell membrane, G protein-dependent pathways, and linkage between the cytoskeleton and the phospholipase C or phospholipase A pathways. The tight interaction of each of these pathways would suggest that the entire cell is a mechanosensor and there are many different pathways available for the transduction of a mechanical signal. In the transmission of signal, osteoblasts, osteocytes, and bone lining cells may act as sensors of mechanical signals and may communicate the signal through cell processes connected by gap junctions. These cells also produce paracrine factors that may signal osteoprogenitors to differentiate into osteoblasts and attach to the bone surface. Insulin-like growth factors and prostaglandins are possible candidates for intermediaries in signal transduction. In the effector cell response, the effects of mechanical loading are dependent upon the magnitude, duration, and rate of the applied load. Longer duration, lower amplitude loading has the same effect on bone formation as loads with short duration and high amplitude. Loading must be cyclic to stimulate new bone formation. Aging greatly reduces the osteogenic effects of mechanical loading in vivo. Also, some hormones may interact with local mechanical signals to change the sensitivity of the sensor or effector cells to mechanical load.

Non-NASA Center↗

Phase transition in two-dimensional tellurene under mechanical strain modulation

Here, we carry out computational simulations based on density functional theory (DFT) to investigate different phases of two-dimensional (2-D) tellurene. These phases are classified by their characteristic space groups and symmetry elements. Correlations of these phases to the bulk crystalline tellurium structure are also illustrated. Our specific interests include mechanical property calculations for different phases and the possible phase transitions between them. Simulation results show that these 2-D Te phases have very different elastic moduli due to their different atomic bonding and relaxed structures. Moreover, compression along the in-plane directions facilitates the α → β phase transition, while in-plane tensile strains always make the α-phase more stable than the β-phase. However, the energy difference between the two phases is comparable to or even much smaller than the thermal energy kT, depending on the in-plane strain direction. We find that further increase of the tensile strain along the chain direction beyond a critical value, ca. 12%, may lead to a possible α → γ phase transition. As the tensile strain is above 15%, the γ-phase will be more stable than the α-phase, accompanied by a further reduced transition energy barrier.

2-D materials↗

In situ electric field X-ray total scattering reveals composition-dependent electromechanical strain mechanisms in (1 − x )BiFe 2/8 Ti 3/8 Mg 3/8 O 3 – x PbTiO 3 ceramics

Ferroelectric materials find many applications in energy and aerospace industries. A major challenge for ferroelectric materials is maintaining their properties at elevated temperatures. The (1 − x )BiFe 2/8 Ti 3/8 Mg 3/8 O 3 – x PbTiO 3 (BFTM–xPT) ferroelectric solid solution is a promising candidate for high-temperature applications as it has a high piezoelectric response while also maintaining its ferroelectric phase until a high Curie temperature (T C ) of 650 °C. In this work, we investigate the piezoelectric mechanism in BFTM–xPT, a novel high-T C ferroelectric ceramic. To elucidate the origin of its enhanced piezoelectric performance, relative to other piezoceramics of similar T C , in situ electric field X-ray total scattering experiments were performed. Total scattering combines Bragg scattering (diffraction) and diffuse scattering (pair distribution function), providing insight on various length scales. With information spanning different length scales, extrinsic contributions (i.e., domain wall motion and interphase boundary motion) can be separated from intrinsic contributions (i.e., piezoelectric lattice strain). We show that, for compositions within the morphotropic phase boundary (MPB, x = 0.325), the piezoelectric response is dominated by intrinsic piezoelectric lattice strain, whereas outside the MPB (x = 0.375) the major component of the piezoelectric response is from extrinsic mechanisms including an electric-field-induced phase transition and tetragonal domain wall motion. This article reveals that the origin of piezoelectric response in BFTM–xPT is composition-dependent and shows that high-performance materials may also be located outside the MPB. These findings can help guide material design to optimize properties for specific applications.

Richtik, Brooke N. [University of Calgary, AB (Can↗

Analysis of Deformation Mechanisms, Strain Localization, and Fracture in Highly Irradiated Austenitic Steels – Light-Water Reactor Core Materials – via Advanced inSEM Techniques

The present report describes the establishing of an advanced experimental approach – high-resolution digital image correlation or µDIC – for testing miniature irradiated specimens in the ORNL’s Low Activation Materials Development and Analysis (LAMDA) facility. As expected, the µDIC approach will allow for studying strain localization inside grains, for instance, during dislocation channel-grain boundary interaction processes. This information is of high importance for understanding degradation processes in irradiated austenitic steels – in-core materials of Light Water Reactors. The Level 4 report provides a brief introduction, lists materials designated for µDIC testing and delivered in LAMDA this FY, discusses methodical concerns and preliminary observations.

22 GENERAL STUDIES OF NUCLEAR REACTORS↗