Search NASA⌕ Search

SEARCH · Search NASA

Results for “mechanical vapor compression”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Component innovations for lower cost mechanical vapor compression

Despite significant capital and operating costs, mechanical vapor compression (MVC) remains the preferred technology for challenging brine concentration applications. Here, this work seeks to assess the dependence of MVC costs on feedwater salinity and desired water recovery and to quantify the value of improved component performance or reduced component costs for reducing the levelized cost of water (LCOW) of MVC. We built a cost optimization model coupling thermophysical, heat and mass transfer, and technoeconomic models to optimize and identify low cost MVC system designs as a function of feedwater salinity and water recovery. The LCOW ranges over 3.6 to 6.1 $\$$/m 3 for seawater feed salinities of 25–150 g/kg and water recoveries of 40–80 %. We then perform sensitivity analysis on parameter inputs to isolate irreducible costs and determine high value component innovation targets. The LCOW was most sensitive to evaporator material costs and performance, including the overall heat transfer coefficient in the evaporator. Process and material innovations such as polymer-composite evaporator tubes that reduce evaporator costs by 25 % without reducing heat transfer performance by more than 10 % would result in MVC cost reductions of 8 %.

42 ENGINEERING↗

Incorporating corrosion design constraints in desalination process optimization: A case study in mechanical vapor compression

Corrosion is an expensive and complex challenge for desalination, yet current design approaches do not explicitly account for corrosion mechanisms in process modeling and technoeconomic analysis. Here, to address this gap, we present a workflow for incorporating corrosion design constraints directly into desalination process optimization models. We develop surrogate models for general and localized corrosion metrics as functions of temperature, pH, salinity, dissolved oxygen, and material using data from OLI Systems’ Corrosion Analyzer. We then integrate these surrogates as corrosion design constraints in a cost-optimization MVC model that minimizes the levelized cost of water (LCOW). For a case study of mechanical vapor compression (MVC) treating seawater across a range of recoveries, we find dissolved oxygen (DO) is the dominant driver of localized corrosion, and thus of cost-optimal material choice and operating conditions. Reducing the DO from 8 mg/L to 0.5 mg/L reduces the LCOW by 15-35%, informing the breakeven costs for implementing DO removal or selecting highly corrosion-resistant alloys. This framework is broadly applicable across corrosion types, materials, and components and enables desalination process design that minimizes capital costs.

36 MATERIALS SCIENCE↗

Energy and exergy analysis of multi-stage vacuum membrane distillation integrated with mechanical vapor compression

Membrane distillation (MD) is a promising candidate for desalinating hypersaline brine, but its poor energy efficiency has remained a major barrier for widespread application. One possible solution to this issue is to recover the latent heat in the process. In this work, a multi-stage vacuum MD (MSVMD) was integrated with a mechanical vapor compressor (MVC) to enhance the latent heat recovery, and the energetic and exergetic performance of this integrated process was examined. A comprehensive energy and exergy analysis is provided to compare MSVMD and MSVMD-MVC processes for desalination of hypersaline brine. This analysis was conducted by examining the effect of the compression ratio on the energetic and exergetic performance, and the findings are reported in terms of specific thermal energy consumption (STEC), specific electricity consumption (SEC), and exergetic efficiency. The energy analysis shows that thermal energy consumption can be reduced as the compression ratio increases, due to the enhancement of latent heat recovery. The MSVMD-MVC process can be operated in a steady-state condition, without the need for thermal heat input; with STEC and SEC of 0 and 49 kWh/m 3 at the feed temperature of 50 °C and MVC compression ratio of 2.14. Moreover, exergy analysis demonstrates the efficacy of the eNRTL model in exergy calculation. Exergy destruction can be greatly reduced by increasing the compression ratio to an optimal value. For high salinity brine (124 g/L), MSVMD-MVC achieved a higher exergetic efficiency of 6.85%, compared to 2.42% in MSVMD. Furthermore, the result suggests that the application of MVC can intensify the energy efficiency and exergetic efficiency of the MSVMD system, although this process cannot outperform the current desalination technologies from the standard primary energy point of view.

42 ENGINEERING↗

Assessing the Accuracy of Property Model Predictions for Cost Optimization of Desalination Technologies

Accurate modeling of seawater thermophysical and thermodynamic properties is critical for optimizing desalination processes. This study compares three seawater property models, a Reaktoro multicomponent model, the thermophysical seawater properties library from the Massachusetts Institute of Technology, and a simplified sodium chloride model, in the context of levelized cost of water (LCOW) minimization for reverse osmosis (RO) and mechanical vapor compression systems. Process simulations and cost optimizations reveal that although all three models yield comparable LCOW and specific energy consumption (SEC) estimates under baseline conditions, deviations among their predictions increase with salinity. Relative differences in LCOW and SEC reach up to 6% and 8%, respectively. RO results show greater variability due to differences in osmotic pressure predictions, which affect pressure constraints at high recoveries. Computational performance varies substantially; specifically, Reaktoro simulations are up to 28 times slower than empirical models due to their detailed equilibrium calculations. These results suggest that empirical models offer acceptable accuracy for routine desalination process design, while Reaktoro provides advantages in scenarios requiring detailed speciation, such as scaling or pH adjustment studies. These findings underscore the importance of selecting appropriate property models based on the modeling objective of desalination applications and motivate future work integrating thermodynamic rigor with empirical efficiency.

Physical and chemical properties↗

Technology Feasibility of High-Temperature Heat Pumps for Industrial Drying Process in the US

High-temperature heat pumps are a prospective technology for electrifying and decarbonizing industrial drying processes. This study investigates the technological potential of HTHPs in replacing fossil-fuel burners or steam boilers in industrial spray dryers. The performance of HTHPs with three configurations was investigated, including high high-temperature heat pump boosted with an electric air heater, a steam-generating high-temperature heat pump with multi-stage mechanical vapor compressions, and transcritical high-temperature heat pumps. R1336mzz(Z) is used as the refrigerant in both subcritical and transcritical high-temperature heat pumps, and R717 is used as the working fluid in the mechanical vapor recompression and the heat transfer fluids. Thermodynamic models are built to evaluate the energy efficiency of HTHPs. A case study was carried out on an industrial spray dryer integrated with a waste heat recuperator, where the HTHPs are used to recover precooled air with a dew point of 40℃ and supply heat for drying air at 200℃. For a high-temperature heat pump boosted with an electric air heater, a higher system-level COP is achieved with a high supply temperature from high-temperature heat pump. For a high-temperature heat pump with mechanical vapor recompressions, larger temperature drops in the flashing tank provide higher heat capacities but almost constant values of the coefficient of performance. For a transcritical high-temperature heat pump, an optimum discharge pressure exists for the temperature profiles within the gas cooler and the coefficient of performance. The transcritical high-temperature heat pump provides the best energy efficiency among the three configurations. The theoretical results prove the technical feasibility of high-temperature heat pumps in industrial air-drying applications. .

Wang, Pengtao↗

Prediction of the Inter-Tube Flow Mode Transitions in the Evaporators of Multi-Effect Thermal Desalination Plants

Water is one of the most stressed resources on the planet. The limited availability of fresh water and the high cost of transportation have led to an increased interest in water desalination technologies. The two main categories of desalination techniques are membrane desalination and thermal desalination. Membrane technologies include pressure driven and electrical driven membranes. On the other hand, thermal desalination includes: multi-effect desalination (MED), multi-stage flash (MSF) desalination, and mechanical vapor compression desalination. Multi-effect desalination plants are usually made of a series of evaporators (also known as effects). In each effect, hot steam flows inside the tubes and evaporates the seawater that falls on the outside of the tubes. The vapor formed at each effect flows to the next effect and acts as the heating medium for the falling seawater. The prevailing flow mode of the falling seawater (i.e. droplet, jet, or sheet) influences heat and mass transfer as well as dry out in the evaporators of Multi-Effect Desalination (MED) plants. The objective of this paper is to predict and discuss the prevailing falling film flow modes in the evaporators of MED plants, under different operating conditions. The paper demonstrates the transitional Reynolds numbers between the main falling film modes for seawater. This closes a gap in the literature where there is a dearth of mode transition data for seawater. The effect of fluid properties and tube geometry on the transitions is discussed in details. As a result, the accuracy of the predicted transitional Reynolds numbers is evaluated via uncertainty quantification techniques.

availability↗

Evaluating Property Model Accuracy for Cost Optimization of Desalination Technologies

Conference presentation conveying work conducted on property modeling and implications on cost optimization of seawater desalination technology. The authors assess the accuracy of four different property modeling approaches to represent thermodynamic properties of seawater. These properties are used with process flowsheets that include either reverse osmosis or mechanical vapor compression. The accuracy of property estimation is related to deviations in process design and levelized cost.

Sakhai, Savannah↗

Low-Carbon District Heating: Performance Modeling of Hybrid Solar, Heat Pump, and Thermal Storage Systems for District Thermal Energy in the United States

District heating requires thermal energy in the temperature range of 40 degrees C - 120 degrees C. Typically, the thermal energy input for these systems has largely been met through fossil energy. However, the temperature range is low enough that it presents an opportunity for low-carbon technologies such as solar thermal and electrified thermal generators like heat pumps to decarbonize the heat generation. In this paper, a heat pump model was applied to estimate the performance and economics of a real-world low-carbon district heating substation. This system is comprised of a flat plate solar collector field paired with a mechanical vapor compression heat pump and hot water thermal storage, augmented by gas-fired boilers. Plant data was used to tune the model and estimate the system's benefits in terms of both standard financial metrics (IRR and payback), and environmental metrics, including avoided CO2 emissions. The model is subsequently employed to estimate the technical and economic potential of solar + heat pump + ther-mal storage hybrid systems as retrofits for district heating systems in eight US Markets.

district heating↗

Evaluation of Mechanical and Thermomechanical Water Vapor Compression Techniques for Enabling High Temperature Lift Hydration-Based Chemical Heat Pumps

Achieving high temperature lifts (>200 K) via a chemical heat pump based on salt hydration/dehydration reactions requires the transport of water vapor from low to high pressure. Alternative compression approaches require condensing of low-pressure water vapor, pumping of liquid water, and subsequent evaporation when the low-side pressure corresponds to sub-ambient water saturation temperatures. Thus, this study compares four steam compression methods for use within a chemical heat pump system based on a reversible calcium oxide hydration/dehydration reaction with a temperature lift from 350 °C heat to >600 °C. Purely mechanical and thermochemical/mechanical compression technologies are considered. A parametric study of maximum allowable temperature, the isentropic efficiency of mechanical compressors, the effectiveness of heat exchangers, and the assumed allowable heat exchanger pressure drop is conducted to determine the mechanical and thermal energy consumed per kilogram of compressed steam. The system complexity in terms of the number of main system components, maximum pressure ratio, and maximum allowable temperature is estimated. Model results show an absorption-based steam compressor has the highest exergetic efficiency for the required chemical heat pump required conditions. As a result, this system configuration was then experimentally demonstrated to illustrate the impact of system performance on component effectiveness.

Advanced reactors↗

Durable Suit Bladder with Improved Water Permeability for Pressure and Environment Suits

Water vapor permeability is shown to be useful in rejecting heat and managing moisture accumulation in launch-and-entry pressure suits. Currently this is accomplished through a porous Gortex layer in the Advanced Crew and Escape Suit (ACES) and in the baseline design of the Constellation Suit System Element (CSSE) Suit 1. Non-porous dense monolithic membranes (DMM) that are available offer potential improvements for water vapor permeability with reduced gas leak. Accordingly, three different pressure bladder materials were investigated for water vapor permeability and oxygen leak: ElasthaneTM 80A (thermoplastic polyether urethane) provided from stock polymer material and two custom thermoplastic polyether urethanes. Water vapor, carbon dioxide and oxygen permeability of the DMM's was measured in a 0.13 mm thick stand-alone layer, a 0.08 mm and 0.05 mm thick layer each bonded to two different nylon and polyester woven reinforcing materials. Additional water vapor permeability and mechanical compression measurements were made with the reinforced 0.05 mm thick layers, further bonded with a polyester wicking and overlaid with moistened polyester fleece thermal underwear .This simulated the pressure from a supine crew person. The 0.05 mm thick nylon reinforced sample with polyester wicking layer was further mechanically tested for wear and abrasion. Concepts for incorporating these materials in launch/entry and Extravehicular Activity pressure suits are presented.

Bue, Grant C.↗

Experimental Investigation of the Effect of Atomizing Electrospray Nozzles on the Cooling and Reduced Humidification of Air

Separating sensible and latent cooling have shown the potential to reduce energy consumption in A/C systems for building HVAC applications. Several technologies exist based on vapor-compression refrigeration, enthalpy wheels, chemical adsorption and absorption materials, and mechanical cooling. However, their thermodynamics limits and high energy consumption hinder their deployment in hot and humid climatic regions. This paper focuses on separating sensible and latent cooling by using a new thermodynamics process and in-kind (i.e., non-vapor compression-based) technology. Highly electrically charged water droplets were sprayed in the airflow. These droplets attracted water vapor molecules to their surfaces and promoted condensation. The phenomenon was the result of simultaneous dielectrophoresis and electro-diffusion interactions. Studies in the literature have shown that using multiple capillary electrodes reduced air moisture by up to 5% when using nanometer-size droplets in the spray. Unfortunately, these studies were limited to low airflow rates, and the objective of this paper was to investigate how to scale up this in-kind approach to airflows typical of buildings. In the present paper, droplets of micrometer size were utilized to control the humidity for a 5-cfm flow rate. While this airflow was still low for building applications, it was 100 times fold the airflows in the literature studies. The air was tested at 20°C and at 50 and 80% relative humidity. A two-fluid atomizing nozzle produced the droplets in the spray, and high DC electric potential, up to 25 kV, was used to charge the fine droplets electrically. The air atomizing nozzle with high voltage potential resembled an evaporative cooler process. However, a measurable reduction of the absolute humidity of up to 2% was observed compared to the case of the nozzle with no high voltage potential. The entire device had one small nozzle selected from off-the-shelf components and had less than a 9 cm2 footprint area.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Hgi2 Sub 2 Crystal Growth for Nuclear Detectors

The objectives of this program are to obtain a benchmark quality sample grown at low-g conditions and to study vapor growth phenomena under space conditions. Ground-based crystals show a defect structure which impairs their performance as nuclear radiation detectors. These defects may be caused by the gravitational force acting on the crystal in its weakended state at the elevated growth temperature and by irregular convection patterns in the vapor during growth. Mechanical strength measurements have been performed (uniaxial compression tests) which show that the crystals exhibit slip parallel to the c-planes at stresses as low as 1/2 psi. Preliminary calculations using a simple linearized model indicate the oscillating instabilities in the convection part of the vapor transport system are unlikely, even at 1-g, provided that the utmost care is taken in the preparation of the crystal growth source material.

Schnepple, W. F.↗

Hydrogen-Steam Separation Using Mechanical Vapor Recompression Cycle

Solar thermochemical hydrogen and fuel production is a promising pathways for producing sustainable fuels and chemicals. One of the main challenges in the development of these systems is their low steam conversion extent, dictated by its restrictive thermodynamics requiring extremely high temperatures and low oxygen partial pressure to obtain conversions over 10 \%. While condensing the unreacted steam is technically simple, the latent heat is thus lost, which can be larger than the producd hydrogen higher heating value. We propose to use a modified mechanical vapor recompression cycle, allowing to recover the latent heat by compressing the steam-hydrogen mixture prior to the condensation process, thus creating a temperature different between the hot exhaust and cold inlet streams. We show that this method can recover over 90 % of the latent heat, thus increasing the viability of solar thermochemical hydrogen production cycles even under limited conversion conditions.

hydrogen technology↗

Sealing Europa’s Vents By Vapor Deposition: An Order-of-Magnitude Study

Fractures and vents in the ice crust of Europa, exposing the sub-surface ocean or liquid-water inclusions to the vacuum, might be responsible for the generation of planetary-scale water-vapor plumes. During its passage through the ice, the plume vapor is expected to partially condense on the cold ice walls. Together with other effects (water spillage, compression forces, etc.) this mechanism likely contributes to sealing the vent. In this work, we develop a lumped-parameter model to analyze the sealing timescales associated to water-vapor deposition alone. Neglecting all other possible mechanisms, we find shutting-off times roughly compatible with the 7-hour plume observed in 2012 by the Hubble Space Telescope, suggesting that vapor deposition might have played a major role in sealing the vent. A map of sealing times vs. plume density, mass flow rate and aperture areas is given. Plume quantities from the literature are analyzed and compared to our results. For a given plume density/mass flow rate, small apertures would be sealed quickly by vapor deposition and are thus incompatible with observations.

Europa↗

Providing Oxygen for the Crew of a Lunar Outpost

Oxygen (O2) is obviously essential for human space missions, but it is important to examine all the different ways it will be used and the potential sources that it may come from. This effort will lead to storage and delivery requirements and help to determine the optimum architecture from an overall systems engineering point of view. Accounting for all the oxygen in a Lunar Outpost mission includes meeting the metabolic needs of the crew while in the surface Habitat, leakage through the Habitat or Pressurized Rover walls, recharge of the space suit backpack and emergency situations. Current plans indicate that both primary and secondary O2 bottles for the space suit will be filled to a pressure of 20.7 MPa (3000 psia). Other uses of O2 require much lower pressure. Sources of O2 at a Lunar Outpost include compressed or liquefied O2 brought along specifically for life support, scavenged O2 from the Lander propulsion system, recovered O2 from waste water or exhaled carbon dioxide and O2 mined from the moon itself. Previously, eight technology options were investigated to provide the high pressure space suit O2. High pressure O2 storage was treated as the baseline technology and compared to the other seven. The other seven were cryogenic storage followed by high pressure vaporization, scavenging liquid oxygen (LOX) from Lander followed by vaporization, LOX delivery followed by sorption compression, low pressure water electrolysis followed by mechanical compression, high pressure water electrolysis, sharing a high pressure electrolyzer with a regenerative fuel cell power system, and making use of In- Situ Resource Utilization (ISRU). This system-level analysis was conducted by comparing equivalent system mass of the eight technologies in open and closed loop life support architectures. The most promising high pressure O2 generation technologies were recommended for development. Updates and an expansion of the earlier study have been made and the results are reported in this paper. Examples of recent analyses include feasibility of recovering space suit purge O2 in a Pressurized Rover and using sub-critical LOX for primary supply while using high-pressure gaseous O2 as the secondary supply for the space-suit. Preliminary analysis on scavenging LOX from the Lander and delivering it to the Habitat has also been incorporated into this integrated lunar fluids analysis

Ewert, Michael K.↗

A critical review of electrochemical heat pump technologies: Status, challenges, and perspectives

The development of advanced heat pump technologies is critical for reducing global energy consumption in the building sector, where space heating and cooling account for nearly 50% of energy use. Electrochemical heat pumps (EHPs) offer a promising alternative to vapor compression systems by enabling direct electrochemical-to-thermal energy conversion, often with environmentally benign working fluids that exhibit low or zero global warming potential (GWP). Prior literature has predominantly focused on chemically reactive heat pumps, while comprehensive assessments of electrochemical mechanisms remain limited. Here, this review addresses this gap by systematically evaluating the underlying principles, architectures, and performance metrics of EHP systems. Compared to conventional vapor compression systems, EHPs can achieve 10%-30% higher energy efficiency, with reported cooling coefficients of performance (COP c ) ranging from 3.5 to 14.3 under standard operating conditions. Despite these advantages, widespread adoption is hindered by challenges including membrane degradation, electrode fouling, sluggish redox kinetics, and elevated system-level capital costs. To address these limitations, the review outlines three research priorities: (i) the development of advanced membranes, catalysts, and electrode materials with enhanced chemical and mechanical stability; (ii) the application of molecular-level simulations for the rational design of high-performance redox-active working fluids; and (iii) the integration of advanced diagnostic techniques for real-time monitoring and sustained operation of EHPs. By consolidating recent advances and explicitly identifying technological and scientific gaps, this work uniquely contributes a comprehensive framework for guiding future electrochemical heat pump research and facilitating the transition to sustainable thermal management technologies.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗