Search NASA⌕ Search

SEARCH · Search NASA

Results for “mechanical ventilation”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Pulmonary blood flow distribution in sheep: effects of anesthesia, mechanical ventilation, and change in posture

BACKGROUND: Recent studies providing high-resolution images of pulmonary perfusion have questioned the classical zone model of pulmonary perfusion. Hence the present work was undertaken to provide detailed maps of regional pulmonary perfusion to examine the influence of anesthesia, mechanical ventilation, and posture. METHODS: Pulmonary perfusion was analyzed with intravenous fluorescent microspheres (15 microm) in six sheep studied in four conditions: prone and awake, prone with pentobarbital-anesthesia and breathing spontaneously, prone with anesthesia and mechanical ventilation, and supine with anesthesia and mechanical ventilation. Lungs were air dried at total lung capacity and sectioned into approximately 1,100 pieces (about 2 cm3) per animal. The pieces were weighed and assigned spatial coordinates. Fluorescence was read on a spectrophotometer, and signals were corrected for piece weight and normalized to mean flow. Pulmonary blood flow heterogeneity was assessed using the coefficient of variation of flow data. RESULTS: Pentobarbital anesthesia and mechanical ventilation did not influence perfusion heterogeneity, but heterogeneity increased when the animals were in the supine posture (P < 0.01). Gravitational flow gradients were absent in the prone position but present in the supine (P < 0.001 compared with zero). Pulmonary perfusion was distributed with a hilar-to-peripheral gradient in animals breathing spontaneously (P < 0.05). CONCLUSIONS: The influence of pentobarbital anesthesia and mechanical ventilation on pulmonary perfusion heterogeneity is small compared with the effect of changes in posture. Analysis of flow gradients indicate that gravity plays a small role in determining pulmonary blood flow distribution.

NASA Discipline Cardiopulmonary↗

Regional ventilation-perfusion distribution is more uniform in the prone position

The arterial blood PO(2) is increased in the prone position in animals and humans because of an improvement in ventilation (VA) and perfusion (Q) matching. However, the mechanism of improved VA/Q is unknown. This experiment measured regional VA/Q heterogeneity and the correlation between VA and Q in supine and prone positions in pigs. Eight ketamine-diazepam-anesthetized, mechanically ventilated pigs were studied in supine and prone positions in random order. Regional VA and Q were measured using fluorescent-labeled aerosols and radioactive-labeled microspheres, respectively. The lungs were dried at total lung capacity and cubed into 603-967 small ( approximately 1.7-cm(3)) pieces. In the prone position the homogeneity of the ventilation distribution increased (P = 0.030) and the correlation between VA and Q increased (correlation coefficient = 0.72 +/- 0.08 and 0.82 +/- 0.06 in supine and prone positions, respectively, P = 0.03). The homogeneity of the VA/Q distribution increased in the prone position (P = 0.028). We conclude that the improvement in VA/Q matching in the prone position is secondary to increased homogeneity of the VA distribution and increased correlation of regional VA and Q.

NASA Program Biomedical Research and Countermeasur↗

Dynamics of airborne fungal populations in a large office building

The increasing concern with bioaerosols in large office buildings prompted this prospective study of airborne fungal concentrations in a newly constructed building on the Gulf coast. We collected volumetric culture plate air samples on 14 occasions over the 18-month period immediately following building occupancy. On each sampling occasion, we collected duplicate samples from three sites on three floors of this six-story building, and an outdoor sample. Fungal concentrations indoors were consistently below those outdoors, and no sample clearly indicated fungal contamination in the building, although visible growth appeared in the ventilation system during the course of the study. We conclude that modern mechanically ventilated buildings prevent the intrusion of most of the outdoor fungal aerosol, and that even relatively extensive air sampling protocols may not sufficiently document the microbial status of buildings.

NASA Program Biomedical Research and Countermeasur↗

Body position does not affect the hemodynamic response to venous air embolism in dogs

Current therapy for massive venous air embolism (VAE) includes the use of the left lateral recumbent (LLR) position. This recommendation is based on animal studies, conducted 50 yr ago, which looked primarily at survival. Little is known, however, about the concomitant hemodynamic response after VAE in various body positions. The purpose of this study was to investigate the hemodynamic and cardiovascular changes in various body positions after VAE. Twenty-two mechanically ventilated supine mongrel dogs received a venous air infusion of 2.5 mL/kg at a rate of 5 mL/s. One minute after the infusion, 100% oxygen ventilation was commenced and the body position of the dogs was changed to either the LLR (n = 6), the LLR with the head 10 degrees down (LLR-10 degrees; n = 6) or the right lateral recumbent (RLR; n = 5) position. Five dogs were maintained in the supine position (SUP; n = 5). One dog died in every group except in the SUP group, where all the dogs recovered. There were no significant differences among the various body positions in terms of heart rate, mean arterial pressure, pulmonary artery pressure, central venous pressure, left ventricular end-diastolic pressure, or cardiac output. The acute hemodynamic changes occurring during the first 5-15 min after VAE recovered to 80% of control within 60 min. Our data suggest that body repositioning does not influence the cardiovascular response to VAE. Specifically, our data do not support the recommendation of repositioning into the LLR position for the treatment of VAE.

Non-NASA Center↗

Cardiopulmonary responses to acute hypoxia, head-down tilt and fluid loading in anesthetized dogs

Cardiopulmonary responses to acute hypoxia (HY), fluid loading by saline infusion (FL), and head-down tilt (HD) of mechanically ventilated anesthetized dogs were investigated by measuring thermodynamics and pulmonary gas exchange. It was found that HD decreased the total respiratory compliance both during HY and normoxia (NO) and that the reduction in compliance by FL was twice as large as by HD. Superimposing HD on HY doubled the increase in vascular resistance due to HY alone. In the systemic circulation, HD lowered the resistance to below NO levels. There was a significant positive correlation between the changes in blood volume and in pulmonary artery pressure for experimental transitions, suggesting that a shift in blood volume from systemic to pulmonary circulations and changes in the total blood volume may contribute substantially to these apparent changes in resistance.

Loeppky, J. A.↗

Body position does not affect the hemodynamic response to venous air embolism in dogs

Current therapy for massive venous air embolism (VAE) includes the use of the left lateral recumbent (LLR) position. This recommendation is based on animal studies, conducted 50 years ago, which looked primarily at survival. Little is known, however, about the concomitant hemodynamic response after VAE in various body positions. The purpose of this study was to investigate the hemodynamic and cardiovascular changes in various body positions after VAE. Twenty-two mechanically ventilated supine mongrel dogs received a venous air infusion of 2.5 mL/kg at a rate of 5 mL/s. One minute after the infusion, 100% oxygen ventilation was commenced and the body position of the dogs was changed to either the LLR (n = 6), the LLR with the head 10 deg down (LLR-10 deg; n = 6) or the right lateral recumbent (RLR; n = 5) position. Five dogs were maintained in the supine position (SUP; n = 5). One dog died in every group except in the SUP group, where all the dogs recovered. There were no significant differences among the various body positions in terms of heart rate, mean arterial pressure, pulmonary artery pressure, central venous pressure, left ventricular end-diastolic pressure, or cardiac output. The acute hemodynamic changes occurring during the first 5-15 min after VAE recovered to 80% of control within 60 min. Our data suggest that body repositioning does not influence the cardiovascular response to VAE. Specifically, our data do not support the recommendation of repositioning into the LLR position for the treatment of VAE.

Mehlhorn, Uwe↗

Stimulated single fiber electromyography in the mouse: techniques and normative data

As the number of new transgenic mouse models of human neuromuscular disease continues to increase, the development of sophisticated electrophysiologic techniques for assessing the peripheral nervous system in these models has become important. Neuromuscular junction (NMJ) dysfunction, in particular, is often not detectable by morphologic or other techniques. To enable sensitive testing of murine NMJ function, we developed and tested a method for stimulated single fiber electromyography (S-SFEMG) in the gastrocnemius muscles of anesthetized mice. Jitter was assessed by measuring the mean consecutive latency difference (MCD) of single fiber responses to sciatic nerve stimulation at 2 HZ. Mean MCD values in normothermic mice were in the range of 6-8 micros for different strains, with no MCD values exceeding 25 micros. Reduced core temperature (to 29 degrees--30 degrees C) resulted in increased jitter, whereas intubation and mechanical ventilation of mice did not alter these values. Intraperitoneal and intravenous injection of vecuronium, however, resulted in progressively increased jitter followed by blocking in continuously monitored fibers. These observations validate the utility of S-SFEMG in mice as an index of NMJ function under a variety of physiologic conditions, and suggest that a high safety factor for neuromuscular transmission exists at mouse NMJs. Copyright 2001 John Wiley & Sons, Inc.

Non-NASA Center↗

Vasomotor tone does not affect perfusion heterogeneity and gas exchange in normal primate lungs during normoxia

To determine whether vasoregulation is an important cause of pulmonary perfusion heterogeneity, we measured regional blood flow and gas exchange before and after giving prostacyclin (PGI(2)) to baboons. Four animals were anesthetized with ketamine and mechanically ventilated. Fluorescent microspheres were used to mark regional perfusion before and after PGI(2) infusion. The lungs were subsequently excised, dried inflated, and diced into approximately 2-cm(3) pieces (n = 1,208-1,629 per animal) with the spatial coordinates recorded for each piece. Blood flow to each piece was determined for each condition from the fluorescent signals. Blood flow heterogeneity did not change with PGI(2) infusion. Two other measures of spatial blood flow distribution, the fractal dimension and the spatial correlation, did not change with PGI(2) infusion. Alveolar-arterial O(2) differences did not change with PGI(2) infusion. We conclude that, in normal primate lungs during normoxia, vasomotor tone is not a significant cause of perfusion heterogeneity. Despite the heterogeneous distribution of blood flow, active regulation of regional perfusion is not required for efficient gas exchange.

Non-NASA Center↗

Ventilation distribution and chest wall mechanics in microgravity

The effect of gravity on lung ventilation distribution and the mechanisms of the chest wall were investigated. The following tests were performed with the respiratory monitoring system of the Anthorack, flown onboard Spacelab D2 mission: single breath washout (SBW), multiple breath washout (MBW) and argon rebreathing (ARB). In order to study chest wall mechanisms in microgravity, a respiratory inductive plethysmograph was used. The SBW tests did not reach statistical significance, while the ARB tests showed that gravity independent inhomogeneity of specific ventilation is larger than gravity dependent inhomogeneity. In which concerns the chest wall mechanisms, the analysis on the four astronauts during the normal respirations of the relaxation maneuver showed a 40 percent increase on the abdominal contribution to respiration.

Paiva, M.↗

Effects of inspired CO2, hyperventilation, and time on VA/Q inequality in the dog

In a recent study by Tsukimoto et al. (J. Appl. Physiol. 68: 2488-2493, 1990), CO2 inhalation appeared to reduce the size of the high ventilation-perfusion ratio (VA/Q) mode commonly observed in anesthetized mechanically air-ventilated dogs. In that study, large tidal volumes (VT) were used during CO2 inhalation to preserve normocapnia. To separate the influences of CO2 and high VT on the VA/Q distribution in the present study, we examined the effect of inspired CO2 on the high VA/Q mode using eight mechanically ventilated dogs (4 given CO2, 4 controls). The VA/Q distribution was measured first with normal VT and then with increased VT. In the CO2 group at high VT, data were collected before, during, and after CO2 inhalation. With normal VT, there was no difference in the size of the high VA/Q mode between groups [10.5 +/- 3.5% (SE) of ventilation in the CO2 group, 11.8 +/- 5.2% in the control group]. Unexpectedly, the size of the high VA/Q mode decreased similarly in both groups over time, independently of the inspired PCO2, at a rate similar to the fall in cardiac output over time. The reduction in the high VA/Q mode together with a simultaneous increase in alveolar dead space (estimated by the difference between inert gas dead space and Fowler dead space) suggests that poorly perfused high VA/Q areas became unperfused over time. A possible mechanism is that elevated alveolar pressure and decreased cardiac output eliminate blood flow from corner vessels in nondependent high VA/Q regions.

NASA Discipline Cardiopulmonary↗

Power turbine ventilation system

Air control mechanism within a power turbine section of a gas turbine engine. The power turbine section includes a rotor and at least one variable pitch propulsor blade. The propulsor blade is coupled to and extends radially outwardly of the rotor. A first annular fairing is rotatable with the propulsor blade and interposed between the propulsor blade and the rotor. A second fairing is located longitudinally adjacent to the first fairing. The first fairing and the second fairing are differentially rotatable. The air control mechanism includes a platform fixedly coupled to a radially inner end of the propulsor blade. The platform is generally positioned in a first opening and a first fairing. The platform and the first fairing define an outer space. In a first position corresponding with a first propulsor blade pitch, the platform is substantially conformal with the first fairing. In a second position corresponding with the second propulsor blade pitch, an edge portion of the platform is displaced radially outwardly from the first fairing. When the blades are in the second position and rotating about the engine axis, the displacement of the edge portion with respect to the first fairing allows air to flow from the outer space to the annular cavity.

Wakeman, Thomas G.↗

Investigations of Pulmonary Epithelial Cell Damage due to Air-Liquid Interfacial Stresses in a Microgravity Environment

Pulmonary airway closure is a potentially dangerous event that can occur in microgravity environments and may result in limited gas exchange for flight crew during long-term space flight. Repetitive airway collapse and reopening subjects the pulmonary epithelium to large, dynamic, and potentially injurious mechanical stresses. During ventilation at low lung volumes and pressures, airway instability leads to repetitive collapse and reopening. During reopening, air must progress through a collapsed airway, generating stresses on the airway walls, potentially damaging airway tissues. The normal lung can tolerate repetitive collapse and reopening. However, combined with insufficient or dysfunctional pulmonary surfactant, repetitive airway collapse and reopening produces severe lung injury. Particularly at risk is the pulmonary epithelium. As an important regulator of lung function and physiology, the degree of pulmonary epithelial damage influences the course and outcome of lung injury. In this paper we present experimental and computational studies to explore the hypothesis that the mechanical stresses associated with airway reopening inflict injury to the pulmonary epithelium.

Gaver, Donald P., III↗

Effect of gravitational sedimentation on simulated aerosol dispersion in the human acinus

We studied the effect of gravitational sedimentation on the dispersion of 0.5 and 1 micrometer-diameter particle boluses within a two-dimensional symmetric six-generation model of the human acinus. Boluses were introduced at the beginning of a 2-s inspiration immediately followed by a 4-s expiration, in normal gravity (1 G) and in the absence of gravity (0 G). The flow corresponded to a flow rate at the mouth of 500 ml/s. In 0 G, simulated dispersion (Hsim) was 16 ml for both particle sizes. In 1 G, Hsim was 71 and 242 ml for 0.5 and 1 micrometer-diameter particles, respectively, showing the effect of gravitational sedimentation. The difference between experimental data (J. Appl. Physiol. 86 (1999) 1402) and simulations was independent of particle size. This suggests that the residual dispersion was independent of the intrinsic properties of the particles and was more likely due to other mechanisms such as ventilation inhomogeneities, cardiogenic oscillations and alveolar wall motion. c2003 Elsevier Science Ltd. All rights reserved.

short duration↗

Tone Noise Predictions for a Spacecraft Cabin Ventilation Fan Ingesting Distorted Inflow and the Challenges of Validation

A fan tone noise prediction code has been developed at NASA Glenn Research Center that is capable of estimating duct mode sound power levels for a fan ingesting distorted inflow. This code was used to predict the circumferential and radial mode sound power levels in the inlet and exhaust duct of an axial spacecraft cabin ventilation fan. Noise predictions at fan design rotational speed were generated. Three fan inflow conditions were studied: an undistorted inflow, a circumferentially symmetric inflow distortion pattern (cylindrical rods inserted radially into the flowpath at 15deg, 135deg, and 255deg), and a circumferentially asymmetric inflow distortion pattern (rods located at 15deg, 52deg and 173deg). Noise predictions indicate that tones are produced for the distorted inflow cases that are not present when the fan operates with an undistorted inflow. Experimental data are needed to validate these acoustic predictions, as well as the aerodynamic performance predictions. Given the aerodynamic design of the spacecraft cabin ventilation fan, a mechanical and electrical conceptual design study was conducted. Design features of a fan suitable for obtaining detailed acoustic and aerodynamic measurements needed to validate predictions are discussed.

Koch, L. Danielle↗

Tone Noise Predictions for a Spacecraft Cabin Ventilation Fan Ingesting Distorted Inflow and the Challenges of Validation

A fan tone noise prediction code has been developed at NASA Glenn Research Center that is capable of estimating duct mode sound power levels for a fan ingesting distorted inflow. This code was used to predict the circumferential and radial mode sound power levels in the inlet and exhaust duct of an axial spacecraft cabin ventilation fan. Noise predictions at fan design rotational speed were generated. Three fan inflow conditions were studied: an undistorted inflow, a circumferentially symmetric inflow distortion pattern (cylindrical rods inserted radially into the flowpath at 15deg, 135deg, and 255deg), and a circumferentially asymmetric inflow distortion pattern (rods located at 15deg, 52deg and 173deg). Noise predictions indicate that tones are produced for the distorted inflow cases that are not present when the fan operates with an undistorted inflow. Experimental data are needed to validate these acoustic predictions, as well as the aerodynamic performance predictions. Given the aerodynamic design of the spacecraft cabin ventilation fan, a mechanical and electrical conceptual design study was conducted. Design features of a fan suitable for obtaining detailed acoustic and aerodynamic measurements needed to validate predictions are discussed.

Koch, L. Danielle↗

Contributions of tidal lung inflation to human R-R interval and arterial pressure fluctuations

We studied the effects of mechanical lung inflation on respiratory frequency R-R interval and arterial pressure fluctuations in nine healthy young adults undergoing elective orthopedic surgery. We conducted this research to define the contribution of pulmonary and thoracic stretch receptor input to respiratory sinus arrhythmia. We compared fast Fourier transform spectral power during three modes of ventilation: (1) spontaneous, frequency-controlled (0.25 Hz) breathing, (2) intermittent positive pressure ventilation (0.25 Hz, with a tidal volume of 8 ml/kg) and (3) high frequency jet ventilation (5.0 Hz, 2.5 kg/cm2), after sedation and vecuronium paralysis. Mean R-R intervals, arterial pressures and arterial blood gas levels were comparable during all three breathing conditions. Respiratory frequency systolic pressure spectral power was comparable during spontaneous breathing and conventional mechanical ventilation, but was significantly reduced during high frequency jet ventilation (P < 0.05). Respiratory frequency R-R interval spectral power (used as an index of respiratory sinus arrhythmia) declined dramatically with sedation and muscle paralysis (P < 0.05), but was greater during conventional mechanical, than high frequency jet ventilation (P < 0.05). These results suggest that although phasic inputs from pulmonary and thoracic stretch receptors make a statistically significant contribution to respiratory sinus arrhythmia, that contribution is small.

Clinical Trial↗

Remote manual operator for space station intermodule ventilation valve

The Remote Manual Operator (RMO) is a mechanism used for manual operation of the Space Station Intermodule Ventilation (IMV) valve and for visual indication of valve position. The IMV is a butterfly-type valve, located in the ventilation or air circulation ducts of the Space Station, and is used to interconnect or isolate the various compartments. The IMV valve is normally operated by an electric motor-driven actuator under computer or astronaut control, but it can also be operated manually with the RMO. The IMV valve RMO consists of a handle with a deployment linkage, a gear-driven flexible shaft, and a linkage to disengage the electric motor actuator during manual operation. It also provides visual indication of valve position. The IMV valve RMO is currently being prepared for qualification testing.

Guyaux, James R.↗

Rapid Cycle Amine 4.0 System Development

Carbon dioxide (CO2) and humidity control is a key function of the spacesuit Portable Life Support Subsystem (PLSS). The latest spacesuit design utilizes a pressure swing bed containing a solid amine sorbent to scrub CO2 and humidity produced by the crewmember from the ventilation loop. The solid amine sorbent removes CO2 and humidity from the ventilation loop through a chemisorption mechanism. Simultaneously, CO2 and humidity are desorbed to vacuum via the two-bed pressure swing system during operation. This continuous regeneration allows for longer Extravehicular Activity (EVA) times while minimizing maintenance, consumables, and power usage. This concept has been in development for over 20 years, during which many prototypes and design iterations have been fabricated and evaluated. This paper discusses the recent Rapid Cycle Amine (RCA) design, development, and testing that has been done to advance the technology. The most recent fabrication is the RCA 3.0. It was delivered to NASA Johnson Space Center in 2015 and has since been tested at the component level and at the integrated PLSS level. The purpose of the component level testing was to understand CO2 removal capacity, end-of-life performance, and establish a baseline performance prior to integrated testing. The RCA 3.0 was integrated into the Exploration Extravehicular Mobility Unit (xEMU) PLSS for a comprehensive Design Verification Test (DVT) series. The integrated testing provided the benefit of characterizing the impact performance degradation has on the system. Many of the RCA requirements were developed through analysis, based on the limitations of the PLSS and, in some cases, assumptions about the system and flow behavior. Integrated testing was an opportunity to validate those requirements and assumptions. While the RCA 3.0 was being tested, the next design iteration, RCA 4.0, was under development. The RCA 4.0 preliminary design phase began in late-2019 and shortly after the Preliminary Design Review, the critical design phase began in 2021. The design work has concluded with the completion of a Pre-Manufacturing Review in 2022. This paper provides an overview of the RCA 4.0 system design, summarizes the results of integrated RCA 3.0 testing, and discusses the pertinence of driving requirements such as mass, volume, and power consumption.

Kelsey Bloom↗