Search NASA⌕ Search

SEARCH · Search NASA

Results for “medical diagnostics”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of polymer 'chips' used in medical diagnostics

In recent years, there has been growing interest in creating bio-inspired devices that feature artificial bilayer lipid membranes (BLM), or lipid bilayers. These membranes can be tailored to mimic the structure and transport properties of cellular walls and can be used to selectively transport ions and other species between aqueous volumes. One application of this research is the formation of a standardized BLM contained within a portable and disposable housing for use in medical diagnostics. This concept utilizes a flexible polymer 'chip' that has internal compartments for housing both an organic solvent and an aqueous solution, which contains phospholipid molecules, proteins, and specific analyte molecules. The formation of a BLM within the chip enables integration of the chip into an electronic reader to perform diagnostic measurements of the sample. A key element of the bilayer formation process requires a single aqueous volume to first be separated into multiple volumes such that it can then be reattached to form a bilayer at the interface. This process, called the regulated attachment method, relies on the geometry of the deformable 'chip' to separate and reattach the aqueous contents held inside by opening and closing an aperture that divides adjacent compartments through the application of mechanical force. The purpose of this research is to develop an optimized chip that provides a controllable method for initially separating the aqueous phase via dynamic excitation. This study focuses on two specific aspects: designing an efficient excitation method for separating the aqueous volume, and optimizing the geometry of the chip to decrease the required input energy and better target the location and duration of the separation. Finite Element (FE) models are used to optimize the chip geometry and to identify suitable excitation signals. A series of experimental studies are also presented to validate the FE models.

42 ENGINEERING↗

Quantum dots in proteomic studies and medical diagnostics

Modern medical diagnostics requires the detection of minor amounts of target proteins at the background of numerous different biological components. With rare exception, these problems cannot be solved by purely physical research methods. In this case, the simplest and efficient approach is concerned with the principles of complementary affine interactions of biopolymers. In this case, high sensitivity of the analysis is achieved by the introduction of labels with certain physical properties in affinity bioreagents. This review is focused on the development of proteomic studies and medical diagnostics with the use of colloidal quantum dots (QDs) as labels in affinity bioreagents. This review is devoted to the description of in vitro proteomic approaches used in the studies and diagnostics, where the problem related to toxicity is not as crucial as in therapy and no restrictions on the types and composition of QDs are imposed. In this case, QDs are considered to be one of the key components of a bioanalytical system. The problems of proteomic medical diagnostics are discussed from the viewpoint of analytical chemistry with the account for the structure and properties of macromolecular analytes and appropriate bioreagents.

60 APPLIED LIFE SCIENCES↗

A Handheld Medical Diagnostic Device for Harsh Environments

Medical diagnostic capabilities for extreme environments, are currently limited in nature to single marker type assays. We propose to develop a handheld device for medical diagnostics in extreme environments that provide sensitive and specific detection of biomarkers with an emphasis initially on radiation exposure. Such a device will have multiple uses, and will be easily adaptable to many applications. For example, first responders, the battlefield, in low resource settings in developing countries facing emerging disease outbreaks, and during long-duration space flights. To this end, we will develop highly adaptable microfluidic devices (cards) for profiling different biomarkers with an emphasis on those related to radiation exposure. We will leverage the previous centrifugal separator work from LLNL and Sandia National Laboratory. The radiation exposure biomarker work at LLNL will provide a biological platform for demonstrating the utility of the device. We will develop a fluidic system using a pump-less mechanical method (centrifugal) to move, control, order and layer fluids in the platform. This decreases complexity, while enabling simultaneous cell separation and plasma generation for two uses: the first is differential blood cell counts and the second is biomarker assay panels. This work will be accomplished in three Aims: Aim 1) Test multiplex microfluidic cards and integrated reader. Aim 2) Demonstrate system capabilities to take and process blood samples for multi-endpoint analysis. Aim 3) Test multiplex detection based on measuring differential blood cell counts, while measuring plasma protein biomarkers. The proposed work addresses the mission research challenge of chemical and biological countermeasure in that our work aims to provide new research capabilities to respond to man-made or natural outbreaks of pandemic diseases in particular in low resource and triage environments.

60 APPLIED LIFE SCIENCES↗

SU-E-P-01: An Informative Review On the Role of Diagnostic Medical Physicist in the Academic and Private Medical Centers

Purpose: The role of physicist in the academic and private hospital environment continues to evolve and expand. This becomes more obvious with the newly revised requirements of the Joint Commission (JC) on imaging modalities and the continued updated requirements of ACR accreditation for medical physics (i.e., starting in June 2014, a physicists test will be needed before US accreditation). We provide an informative review on the role of diagnostic medical physicist and hope that our experience will expedite junior physicists in understanding their role in medical centers, and be ready to more opportunities. Methods: Based on our experience, diagnostic medical physicists in both academic and private medical centers perform several clinical functions. These include providing clinical service and physics support, ensuring that all ionizing radiation devices are tested and operated in compliance with the State and Federal laws, regulations and guidelines. We also discuss the training and education required to ensure that the radiation exposure to patients and staff is as low as reasonably achievable. We review the overlapping roles of medical and health physicist in some institutions. Results: A detailed scheme on the new requirements (effective 7/1/2014) of the JC is provided. In 2015, new standards for fluoroscopy, cone beam CT and the qualifications of staff will be phased in. A summary of new ACR requirements for different modalities is presented. Medical physicist have other duties such as sitting on CT and fluoroscopy committees for protocols design, training of non-radiologists to meet the new fluoroscopy rules, as well as helping with special therapies such as Yittrium 90 cases. Conclusion: Medical physicists in both academic and private hospitals are positioned to be more involved and prominent. Diagnostic physicists need to be more proactive to involve themselves in the day to day activities of the radiology department.

60 APPLIED LIFE SCIENCES↗

Entropy removal of medical diagnostics

Shannon entropy is a core concept in machine learning and information theory, particularly in decision tree modeling. To date, no studies have extensively and quantitatively applied Shannon entropy in a systematic way to quantify the entropy of clinical situations using diagnostic variables (true and false positives and negatives, respectively). Decision tree representations of medical decision-making tools can be generated using diagnostic variables found in literature and entropy removal can be calculated for these tools. This concept of clinical entropy removal has significant potential for further use to bring forth healthcare innovation, such as quantifying the impact of clinical guidelines and value of care and applications to Emergency Medicine scenarios where diagnostic accuracy in a limited time window is paramount. This analysis was done for 623 diagnostic tools and provided unique insights into their utility. For studies that provided detailed data on medical decision-making algorithms, bootstrapped datasets were generated from source data to perform comprehensive machine learning analysis on these algorithms and their constituent steps, which revealed a novel and thorough evaluation of medical diagnostic algorithms.

97 MATHEMATICS AND COMPUTING↗

Noninvasive Medical Diagnostics & Treatment Using Ultrasonics

In parallel to the industrial application of NDE to flaw detection and material property determination, the medical community has succesfully adapted such methods to the noninvasaive diagnostics and treatment of many conditions and disorders of the human body.

NDE noninvasive diagnostics destruction of blood c↗

Refraction Introscopy Imaging at Synchrotron Radiation for Medical Diagnostics

The technique of X-ray refraction introscopy imaging is reviewed. Experiments on the refraction imaging carried out at the Kurchatov Synchrotron Radiation Source with mammographic phantom, small laboratory animals, and model objects are described. Contrast enhancement compared to conventional imaging is demonstrated.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Coupling apparatus for ultrasonic medical diagnostic system

An apparatus for the ultrasonic scanning of a breast or other tissue is reported that contains a cavity for receiving the breast, a vacuum for drawing the breast into intimate contact with the walls of the cavity, and transducers coupled through a fluid to the cavity to transmit sound waves through the breast. Each transducer lies at the end of a tapered chamber which has flexible walls and which is filled with fluid, so that the transducer can be moved in a raster pattern while the chamber walls flex accordingly, with sound transmission always occurring through the fluid.

Frazer, R. E.↗

Use of lipid particles in medical diagnostics

Disclosed herein are methods for identifying one or more diseased cells in a subject. Some embodiments include providing a biological sample derived from a subject, analyzing the biological sample by mass spectrometry, and determining the abundance of one or more lipids in the biological sample, wherein an altered abundance of the one or more lipids in the biological sample, as compared to a reference level, indicates a presence of one or more diseased cells in the subject from which the biological sample is derived.

Louie, Katherine B.↗

Towards intelligent diagnostic system employing integration of mathematical and engineering model

The development of medical diagnostic system has been one of the main research fields during years. The goal of the medical diagnostic system is to place a nosological system that could ease the diagnostic evaluation normally performed by scientists and doctors. Efficient diagnostic evaluation is essentials and requires broad knowledge in order to improve conventional diagnostic system. Several approaches on developing the medical diagnostic system have been designed and tested since the earliest 60s. Attempts on improving their performance have been made which utilizes the fields of artificial intelligence, statistical analyses, mathematical model and engineering theories. With the availability of the microcomputer and software development as well as the promising aforementioned fields, medical diagnostic prototypes could be developed. In general, the medical diagnostic system consists of several stages, namely the 1) data acquisition, 2) feature extraction, 3) feature selection, and 4) classifications stages. Data acquisition stage plays an important role in converting the inputs measured from the real world physical conditions to the digital numeric values that can be manipulated by the computer system. One of the common medical inputs could be medical microscopic images, radiographic images, magnetic resonance image (MRI) as well as medical signals such as electrocardiogram (ECG) and electroencephalogram (EEG). Normally, the scientist or doctors have to deal with myriad of data and redundant to be processed. In order to reduce the complexity of the diagnosis process, only the significant features of the raw data such as peak value of the ECG signal or size of lesion in the mammogram images will be extracted and considered in the subsequent stages. Mathematical models and statistical analyses will be performed to select the most significant features to be classified. The statistical analyses such as principal component analysis and discriminant analysis as well as mathematical model of clustering technique have been widely used in developing the medical diagnostic systems. The selected features will be classified using mathematical models that embedded engineering theory such as artificial intelligence, support vector machine, neural network and fuzzy-neuro system. These classifiers will provide the diagnostic results without human intervention. Among many publishable researches, several prototypes have been developed namely NeuralPap, Neural Mammo, and Cervix Kit. The former system (NeuralPap) is an automatic intelligent diagnostic system for classifying and distinguishing between the normal and cervical cancerous cells. Meanwhile, the Cervix Kit is a portable Field-programmable gate array (FPGA)-based cervical diagnostic kit that could automatically diagnose the cancerous cell based on the images obtained during sampling test. Besides the cervical diagnostic system, the Neural Mammo system is developed to specifically aid the diagnosis of breast cancer using a fine needle aspiration image.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Science and Technology Review July/August 2009

This month's issue has the following articles: (1) Game-Changing Science in the National Interest - Commentary by Tomas Diaz de la Rubia; (2) Preventing Close Encounters of the Orbiting Kind - The Testbed Environment for Space Situational Awareness is improving capabilities for monitoring and detecting threats to space operations; (3) A CAT Scanner for Nuclear Weapon Components - A new x-ray system images nuclear weapon components in three dimensions, promising unprecedented resolution and clarity; (4) Mass-Producing Positrons - Scientists reveal a new method for yielding a greater density of positrons at a much faster rate inside a laboratory setting; and (5) The Next Generation of Medical Diagnostic Devices - Portable medical diagnostic devices using ultrawideband technology help first responders evaluate injuries in emergency situations and could improve overall health care.

99 GENERAL AND MISCELLANEOUS↗

WE-AB-BRB-03: Investigation of a Small Photomultiplier-Based Probe for Use in Beam Diagnostics and Medical Dosimetry

Purpose: Investigate the use of a small photomultiplier-based probe as a possible beam diagnostic and medical dosimetry tool. Methods: Cerenkov emission produced by clinical accelerator beams was detected by a small photomultiplier tube (PMT). Measurements of Clinac beams were made both in air and by inserting the PMT directly into a water phantom. A conical collimator placed in front of the PMT reduced the angular acceptance and the detection of scattered light. With this arrangement, we obtained response curves as a function of depth along the central axis similar in shape and magnitude to those obtained with ionization chambers. Subsequent measurements were made with the PMT covered in aluminum foil, obtaining a signal arising primarily from direct Cerenkov light produced in the glass entrance window. With an oscilloscope and amplifier/MCA system, we were able to monitor the response to individual beam pulses and observe variations in the beam pulse shape and magnitude as a function of dose rate. Results: Using Cerenkov signals detected by a PMT, we were able to obtain reasonable beam quality metrics, and the response was found to be linear over a range of dose rates. The fast response of the PMT allowed for the observation of small changes in the shape and magnitude of the beam pulse. With this system we were able to detect small changes in the dose per pulse delivered by the accelerator. Conclusion: A small PMT probe has shown promise as a beam diagnostic and medical dosimetry tool. Its fast response allows for real time beam pulse monitoring, and the integrated response can yield relative and perhaps even absolute dose information with a properly calibrated system. For accelerator diagnostics, monitoring of the beam pulse shape can aid in beam tuning, particularly in electron mode, where no target current pulse is available.

60 APPLIED LIFE SCIENCES↗