Search NASA⌕ Search

SEARCH · Search NASA

Results for “medical equipment”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Development of Skylab medical equipment and flight preparations

The major medical systems in the Skylab orbital workshop are described. They comprise the food system, the waste management system, operational bioinstrumentation, personal hygiene, gas sampling, an inflight medical support system, and a cardiovascular counterpressure garment. Life sciences experiments carried out aboard Skylab are also reviewed; these include an ergometer and metabolic analyzer, a lower-body negative pressure device, an electrode harness and body temperature probe, a blood pressure cuff, a leg volume measuring band, sleep studies, a body-mass measuring device, a rotating litter chair, a blood sample processor, and small-mass measuring apparatus. All performance requirements were met with the equipment, and no failures were encountered.

Johnston, R. S.↗

Methods and devices for sterilizing medical equipment

A hydrogen peroxide sterilization device for sterilizing a medical device, the hydrogen peroxide sterilization device including a hermetic outer container, a hydrogen peroxide pouch, and a hydrogen peroxide solution in the solution chamber. The hermetic outer container includes a sterilization enclosure configured to receive the medical device. The hydrogen peroxide pouch includes a permeable membrane enclosing a solution chamber and is configured to be positioned in the sterilization enclosure of the outer container. The permeable membrane is configured to allow hydrogen peroxide vapor to diffuse from the solution chamber through the permeable membrane into the sterilization enclosure.

Bohnert, George William↗

Miniature diaphragm valve for medical equipment

Valve assembly keeps nutrient out of moving parts of valve by physically isolating plunger from fluid. Poppet and diaphragm are molded together, and latter is shaped to act as static seal, which remains seated during the operation. As plunger moves, diaphragm also moves to form separate cavity for nutrient and thus isolates it from plunger cavity and latching mechanism.

Stadler, T. J.↗

Medical Optimization Network for Space Telemedicine Resources

INTRODUCTION: Long-duration missions beyond low Earth orbit introduce new constraints to the space medical system. Beyond the traditional limitations in mass, power, and volume, consideration must be given to other factors such as the inability to evacuate to Earth, communication delays, and limitations in clinical skillsets. As NASA develops the medical system for an exploration mission, it must have an ability to evaluate the trade space of what resources will be most important. The Medical Optimization Network for Space Telemedicine Resources (MONSTR) was developed over the past year for this reason, and is now a system for managing data pertaining to medical resources and their relative importance when addressing medical conditions. METHODS: The MONSTR web application with a Microsoft SQL database backend was developed and made accessible to Tableau v9.3 for analysis and visualization. The database was initially populated with a list of medical conditions of concern for an exploration mission taken from the Integrated Medical Model (IMM), a probabilistic model designed to quantify in-flight medical risk. A team of physicians working within the Exploration Medical Capability Element of NASA's Human Research Program compiled a list diagnostic and treatment medical resources required to address best- and worst-case scenarios of each medical condition using a terrestrial standard of care and entered this data into the system. This list included both tangible resources (e.g. medical equipment, medications) and intangible resources (e.g. clinical skills required to perform a procedure). The physician team then assigned criticality values to each instance of a resource, representing the importance of that resource to diagnosing or treating its associated condition(s). Medical condition probabilities of occurrence during a Mars mission were pulled from the IMM and imported into the MONSTR database for use within a resource criticality-weighting algorithm. DISCUSSION: The MONSTR tool is a novel approach to assess the relative value of individual resources needed for the diagnosis and treatment of medical conditions. Future work will add resources for prevention and long term care of these conditions. Once data collection is complete, MONSTR will provide the operational and research communities at NASA with information to support informed decisions regarding areas of research investment, future crew training, and medical supplies manifested as part of any exploration medical system.

Rubin, D.↗

Medical Imaging Equipment Energy Efficiency

The energy use of medical imaging equipment (MIE) in healthcare facilities is estimated to be about 5% of total site energy use. MIE energy use is only expected to increase as technology advances and more patients seek services from MIE, enabling more facilities to install additional MIE. Healthcare organizations need reliable information regarding comprehensive energy use or lifetime energy costs with which to make energy-efficient MIE procurement decisions, and there are currently no MIE energy or efficiency standards in the United States (U.S.). This fact sheet provides background on MIE energy consumption, key terms, and guidance on why and how to meter MIE, helping stakeholders make informed decisions to enhance their facility's performance.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

ATLS: Catheter and tube placement

The specific objectives of this experiment are: to evaluate the rack mounted equipment and medical supplies necessary for medical procedures; to evaluate the attachments, mounting points, and inner drawer assemblies for the medical supplies; and to evaluate the procedures for performing medical scenarios. The resources available in the HMF miniracks to accomplish medical scenarios and/or procedures include: medical equipment mounted in the racks; a patch panel with places to attach tubing and catheters; self contained drawers full of critical care medical supplies; and an ALS 'backpack' for deploying supplies. The attachment lines, tubing and associated medical supplies will be deployed and used with the equipment and a patient mannequin. Data collection is provided by direct observations by the inflight experimenters, and analysis of still and video photography.

Gosbee, John↗

Medical Imaging Equipment Energy Efficiency [Slides]

The slide deck is being prepared for healthcare sector stakeholders as a resource on the energy use of Medical Imaging Equipment (MIE) which will provide an overview of existing work, review existing literature on MIE energy use and identify energy efficiency opportunities.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Medical Imaging Equipment Energy Efficiency

The fact sheet is being prepared for stakeholders of Better Building Alliance's (BBA) Healthcare sector as a resource on the energy use of medical imaging equipment. This is a concise version of earlier published slide deck - NREL/PR-5500-83743.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

Haughton-Mars Project/NASA 2006 Lunar Medical Contingency Simulation: Equipment and Methods for Medical Evacuation of an Injured Crewmember

Introduction: Achieving NASA's Space Exploration Vision scientific objectives will require human access into cratered and uneven terrain for the purpose of sample acquisition to assess geological, and perhaps even biological features and experiments. Operational risk management is critical to safely conduct the anticipated tasks. This strategy, along with associated contingency plans, will be a driver of EVA system requirements. Therefore, a medical contingency EVA scenario was performed with the Haughton-Mars Project/NASA to develop belay and medical evacuation techniques for exploration and rescue respectively. Methods: A rescue system to allow two rescuer astronauts to evacuate one in incapacitated astronaut was evaluated. The systems main components were a hard-bottomed rescue litter, hand-operated winch, rope, ground picket anchors, and a rover-winch attachment adapter. Evaluation was performed on 15-25deg slopes of dirt with embedded rock. The winch was anchored either by adapter to the rover or by pickets hammered into the ground. The litter was pulled over the surface by rope attached to the winch. Results: The rescue system was utilized effectively to extract the injured astronaut up a slope and to a waiting rover for transport to a simulated habitat for advanced medical care, although several challenges to implementation were identified and overcome. Rotational stabilization of the winch was found to be important to get maximize mechanical advantage from the extraction system. Discussion: Further research and testing needs to be performed to be able to fully consider synergies with the other Exploration surface systems, in conducting contingency operations. Structural attachment points on the surface EVA suits may be critical to assist in incapacitated evacuation. Such attach points could be helpful in microgravity incapacitated crewmember transport as well. Wheeled utility carts or wheels that may be attachable to a litter may also aid in extraction and transport. Utilizing parts of the rover (e.g. seats) to deploy as a litter may be considered. Testing in simulated 1/6-g to determine feasibility of winch operation and anchor establishment will further reduce implementation uncertainties.

Chappell, S. P.↗

International Space Station (ISS) Gas Logistics Planning in the Post Shuttle Era

Over its life the International Space Station (ISS) has received gas (nitrogen, oxygen, and air) from various sources. Nitrogen and oxygen are used in the cabin to maintain total pressure and oxygen partial pressures within the cabin. Plumbed nitrogen is also required to support on-board experiments and medical equipment. Additionally, plumbed oxygen is required to support medical equipment as well as emergency masks and most importantly EVA support. Gas are supplied to ISS with various methods and vehicles. Vehicles like the Progress and ATV deliver nitrogen (both as a pure gas and as air) and oxygen via direct releases into the cabin. An additional source of nitrogen and oxygen is via tanks on the ISS Airlock. The Airlock nitrogen and oxygen tanks can deliver to various users via pressurized systems that run throughout the ISS except for the Russian segment. Metabolic oxygen is mainly supplied via cabin release from the Elektron and Oxygen Generator Assembly (OGA), which are water electrolyzers. As a backup system, oxygen candles (Solid Fuel Oxygen Generators-SFOGs) supply oxygen to the cabin as well. In the past, a major source of nitrogen and oxygen has come from the Shuttle via both direct delivery to the cabin as well as to recharge the ISS Airlock tanks. To replace the Shuttle capability to recharge the ISS Airlock tanks, a new system was developed called Nitrogen/Oxygen Recharge System (NORS). NIORS consists of high pressure (7000 psi) tanks which recharge the ISS Airlock tanks via a blowdown fill for both nitrogen and oxygen. NORS tanks can be brought up on most logistics vehicles such as the HTV, COTS, and ATV. A proper balance must be maintained to insure sufficient gas resources are available on-orbit so that all users have the required gases via the proper delivery method (cabin and/or plumbed).

Leonard, Daniel J.↗

Ampere-Hour Meter For Rechargeable Battery

Low-power analog/digital electronic circuit meters discharge of storage battery in ampere-hours. By metering discharge, one obtains indication of state of charge of battery and avoids unnecessary recharging, maintaining capacity of battery and prolonging life. Because of its small size and low power consumption, useful in such applications as portable video cameras, communication equipment on boats, portable audio equipment, and portable medical equipment.

Tripp, John S.↗

Medical care of spacecrews, (Medical care, equipment, and prophylaxis)

Treatment and prevention of the physiologic problems of spacecrews are discussed. Preflight procedures, inflight monitoring and medication, and postflight examination are described. Specific factors covered include: medical screening and astronaut selection; health stabilization and exposure prevention; preflight medical examinations and training; biomedical data; medical kits; diagnosis and treatment; and implications of postflight findings.

Berry, C. A.↗

FY 2017 Center Innovation Fund Annual Report - Highlights/Abstract section

This project evaluated the feasibility of low pressure cold plasma (CP) for two applications: disinfection of produce grown in space and sterilization of medical equipment in space. Currently there is no ISS capability for disinfecting pick and eat crops, food utensils, food production areas, or medical devices. This deficit is extended to projected long duration missions. Small, portable, cold plasma devices would provide an enhanced benefit to crew health and address issues concerning microbial cross contamination. The technology would contribute to the reduction of solid waste since currently crews utilize benzalkonium chloride wet wipes for cleaning surfaces and might use PRO-SAN wipes for cleaning vegetables. CP cleaning/disinfection/sterilization can work on many surfaces, including all metals, most polymers, and this project evaluated produce. Therefore CP provides a simple system that has many different cleaning application in space: produce, medical equipment, cutlery, miscellaneous tools.

plant growt↗

Performance Support Tools for Space Medical Operations

The early Constellation space missions are expected to have medical capabilities very similar to those currently on the Space Shuttle and International Space Station (ISS). For Crew Exploration Vehicle (CEV) missions to ISS, medical equipment will be located on ISS, and carried into CEV in the event of an emergency. Flight Surgeons (FS) on the ground in Mission Control will be expected to direct the Crew Medical Officer (CMO) during medical situations. If there is a loss of signal and the crew is unable to communicate with the ground, a CMO would be expected to carry out medical procedures without the aid of a FS. In these situations, performance support tools can be used to reduce errors and time to perform emergency medical tasks. Human factors personnel at Johnson Space Center have recently investigated medical performance support tools for CMOs on-orbit, and FSs on the ground. This area of research involved the feasibility of Just-in-time (JIT) training techniques and concepts for real-time medical procedures. In Phase 1, preliminary feasibility data was gathered for two types of prototype display technologies: a hand-held PDA, and a Head Mounted Display (HMD). The PDA and HMD were compared while performing a simulated medical procedure using ISS flight-like medical equipment. Based on the outcome of Phase 1, including data on user preferences, further testing was completed using the PDA only. Phase 2 explored a wrist-mounted PDA, and compared it to a paper cue card. For each phase, time to complete procedures, errors, and user satisfaction were captured. Information needed by the FS during ISS mission support, especially for an emergency situation (e.g. fire onboard ISS), may be located in many different places around the FS s console. A performance support tool prototype is being developed to address this issue by bringing all of the relevant information together in one place. The tool is designed to include procedures and other information needed by a FS during an emergency, as well as procedures and information to be used after the emergency is resolved. Several walkthroughs of the prototype with FSs have been completed within a mockup of an ISS FS console. Feedback on the current tool design as well as recommendations for existing ISS FS displays were captured.

Byrne, Vicky E.↗

Human Factors in Training - Space Medicine Proficiency Training

The early Constellation space missions are expected to have medical capabilities very similar to those currently on the Space Shuttle and International Space Station (ISS). For Crew Exploration Vehicle (CEV) missions to ISS, medical equipment will be located on ISS, and carried into CEV in the event of an emergency. Flight Surgeons (FS) on the ground in Mission Control will be expected to direct the Crew Medical Officer (CMO) during medical situations. If there is a loss of signal and the crew is unable to communicate with the ground, a CMO would be expected to carry out medical procedures without the aid of a FS. In these situations, performance support tools can be used to reduce errors and time to perform emergency medical tasks. Work on medical training has been conducted in collaboration with the Medical Training Group at the Space Life Sciences Directorate and with Wyle Lab which provides medical training to crew members, Biomedical Engineers (BMEs), and to flight surgeons under the JSC Space Life Sciences Directorate s Bioastronautics contract. The space medical training work is part of the Human Factors in Training Directed Research Project (DRP) of the Space Human Factors Engineering (SHFE) Project under the Space Human Factors and Habitability (SHFH) Element of the Human Research Program (HRP). Human factors researchers at Johnson Space Center have recently investigated medical performance support tools for CMOs on-orbit, and FSs on the ground, and researchers at the Ames Research Center performed a literature review on medical errors. The work proposed for FY10 continues to build on this strong collaboration with the Space Medical Training Group and previous research. This abstract focuses on two areas of work involving Performance Support Tools for Space Medical Operations. One area of research building on activities from FY08, involved the feasibility of just-in-time (JIT) training techniques and concepts for real-time medical procedures. In Phase 1, preliminary feasibility data was gathered for two types of prototype display technologies: a hand-held PDA, and a Head Mounted Display (HMD). The PDA and HMD were compared while performing a simulated medical procedure using ISS flight-like medical equipment. Based on the outcome of Phase 1, including data on user preferences, further testing was completed using the PDA only. Phase 2 explored a wrist-mounted PDA, and compared it to a paper cue card. For each phase, time to complete procedures, errors, and user satisfaction ratings were captured.

Connell, Erin↗

Evaluation of Low-Pressure Cold Plasma for Disinfection for ISS Grown Produce and Metallic Instrumentation

Cold plasma (CP) cleaning is a dry, non-thermal process, which can provide broad-spectrum antimicrobial activity yet reportedly causes little to no damage to the object being sanitized. Since cold plasma uses no liquids, it has the distinct advantage when used in microgravity of not having to separate liquids from the item being cleaned. This paper will present results on an effort to use low pressure CP to disinfect or sterilize materials for in space applications. Exposure times from 0 to 60 minutes and pressures ranging from 10 to 100 Pa were used to optimize plasma parameters to achieve acceptable kill rates for 3 bacteria, Bacillus cereus, E. coli and Bacillus pumulis SAFR-32 and one fungi, Aspergillus niger. These tests were done on produce and metal coupons to simulate medical equipment. Produce testing was not successful, with unacceptable kill rates and the produce being negatively impacted by exposure to the plasma. The plasma caused a 5 log reduction in the number of viable bacteria on metal coupon tests, which placed the number of viable bacteria below the detection limit. This is a very promising result showing that sterilization of medical equipment with cold plasma is feasible. Scanning Electron Microscope images were taken before and after exposure. The images after plasma exposure shows that the bacteria spores have been physically affected, as their size has gotten smaller and the appearance has changed.

Hintze, Paul E.↗

Evaluation of Low-Pressure Cold Plasma for Disinfection of ISS Grown Produce and Metallic Instrumentation

Cold plasma (CP) cleaning is a dry, non-thermal process, which can provide broad-spectrum antimicrobial activity yet reportedly causes little to no damage to the object being sanitized. Since cold plasma uses no liquids, it has the distinct advantage when used in microgravity of not having to separate liquids from the item being cleaned. This paper will present results on an effort to use low pressure CP to disinfect or sterilize materials for in space applications. Exposure times from 0 to 60 minutes and pressures ranging from 0.10 to 1.0 mbar were used to optimize plasma parameters. Tests were done on produce and metal coupons to simulate medical equipment. Escherichia coli was used as the challenge organism on produce and Bacillus pumilus SAFR-32 was used on metal surfaces. Produce testing was not successful, with unacceptable kill rates and the produce being negatively impacted by exposure to the plasma. The plasma caused a 5 log reduction in the number of viable bacteria on metal coupon tests, which placed the number of viable bacteria below the detection limit. This is a very promising result showing that sterilization of medical equipment with cold plasma is feasible. Scanning Electron Microscope images were taken before and after exposure. The images after plasma exposure show that the bacteria spores have been physically affected, as their size has gotten smaller and their appearance has changed.

Hintze, Paul E.↗