Search NASA⌕ Search

SEARCH · Search NASA

Results for “medical oxygen”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Portable Cathode-Air Vapor-Feed Electrochemical Medical Oxygen Concentrator (OC)

Missions on the International Space Station and future space exploration will present significant challenges to crew health care capabilities, particularly in the efficient utilization of onboard oxygen resources. Exploration vehicles will require lightweight, compact, and portable oxygen concentrators that can provide medical-grade oxygen from the ambient cabin air. Current pressure-swing adsorption OCs are heavy and bulky, require significant start-up periods, operate in narrow temperature ranges, and require a liquid water feed. Lynntech, Inc., has developed an electrochemical OC that operates with a cathode-air vapor feed, eliminating the need for a bulky onboard water supply. Lynntech's OC is smaller and lighter than conventional pressure-swing OCs, is capable of instant start-up, and operates over a temperature range of 5-80 C. Accomplished through a unique nanocomposite proton exchange membrane and catalyst technology, the unit delivers 4 standard liters per minute of humidified oxygen at 60 percent concentration. The technology enables both ambient-pressure operating devices for portable applications and pressurized (up to 3,600 psi) OC devices for stationary applications.

Balasubramanian, Ashwin↗

Medical Ceramic Oxygen Generator (M-COG) Technology Description

Medical Ceramic Oxygen Generator Technology Description is presented to ISO technical committee 121, subcommittee SC6. Operating principles of ceramic oxygen generation are described, M-COG prototype system designs are described, testing and test results are summarized, and M-COG technology applications for medical oxygen are reviewed and evaluated.

oxygen↗

Medical Ceramic Oxygen Generator: An Emerging Method For Generating Oxygen In-Situ

The NASA Engineering Safety Center is sponsoring a project called Medical Ceramic Oxygen Generator. Technology developed for spacesuit oxygen tank recharge has been directed towards developing a prototype oxygen generator with characteristics favorable for providing hospitals with medical oxygen. This presentation describes the M-COG project.

oxygen↗

Ground Testing of an Oxygen Concentrator in a Simulated International Space Station (ISS) Cabin Environment

The method for supplying medical oxygen to respiratorily-compromised astronauts on the International Space Station (ISS) and in future Orion missions consists of drawing oxygen from high pressure oxygen tanks. An Oxygen Concentrator Module (OCM) is a device that pulls in ambient air and separates out the nitrogen, resulting in a high concentration oxygen source. This technology has the potential to eliminate resupply and oxygen-enrichment issues associated with using high pressure oxygen tanks and become an alternative technology to support medical oxygen operations for future exploration missions. In this study, we test the long-term performance of a Commercial Off-the-Shelf (COTS) OCM in a simulated ISS cabin environment. Humidified air, carbon dioxide, and fifteen representative trace contaminants are continuously injected through an enclosed test chamber where the OCM is challenged. This study included the first successful demonstration of the Trace Gas Injection System (TGIS), which reliably and continuously produced ISS levels of trace contaminants, carbon dioxide, and humidity in an enclosed environment. The TGIS is a new and unique ground capability with significant implications for Test Readiness Level (TRL) advancement of COTS items and Government Furnished Equipment (GFE). This study demonstrated that the tested OCM reliably delivers enriched oxygen mostly at desired performance specifications. This study also demonstrated that the OCM does not inadvertently concentrate trace gases in its oxygen product stream, as detectable concentrations of trace contaminants in the oxygen product stream were at all times below the simulated ISS levels.

medical oxygen↗

Ground Testing of an Oxygen Concentrator in a Simulated International Space Station (ISS) Cabin Environment

The method for supplying medical oxygen to respiratorily-compromised astronauts on the International Space Station (ISS) and in future Orion missions consists of drawing oxygen from high pressure oxygen tanks. An Oxygen Concentrator Module (OCM) is a device that pulls in ambient air and separates out the nitrogen, resulting in a high concentration oxygen source. This technology has the potential to eliminate resupply and oxygen-enrichment issues associated with using high pressure oxygen tanks and become an alternative technology to support medical oxygen operations for future exploration missions. In this study, we test the long-term performance of a Commercial Off-the-Shelf (COTS) OCM in a simulated ISS cabin environment. Humidified air, carbon dioxide, and fifteen representative trace contaminants are continuously injected through a enclosed test chamber where the OCM is challenged. This study included the first successful demonstration of the Trace Gas Injection System (TGIS), which reliably and continuously produced ISS levels of trace contaminants, carbon dioxide, and humidity in an enclosed environment. The TGIS is a new and unique ground capability with significant implications for Test Readiness Level (TRL) advancement of COTS items and Government Furnished Equipment (GFE). This study demonstrated that the tested OCM reliably delivers enriched oxygen mostly at desired performance specifications. This study also demonstrated that the OCM does not inadvertently concentrate trace gases in its oxygen product stream, as detectable concentrations of trace contaminants in the oxygen product stream were at all times below the simulated ISS levels.

medical oxygen↗

Regulating Oxygen Pressure Safely

Pressure regulator for oxygen allows gas flow shut off on low-pressure (outlet) side rather than high-pressure (inlet) side. In modified pressure regulator initial rush of oxygen occurs in second stage rather than first stage of pressure reduction. Large volume of second stage prevents excessive heating of gas. High-pressure source remains on, and first stage reamins pressurized at all times. New regulator reduces danger of fire in aircraft and in medical oxygen supplies.

Simons, C.↗

Oxygen Assessments Ensure Safer Medical Devices

A team at White Sands Test Facility developed a test method to evaluate fire hazards in oxygen-enriched environments. Wendell Hull and Associates, located in Las Cruces, New Mexico, entered a Space Act Agreement with NASA and now provides services including fire and explosion investigations, oxygen testing and training, and accident reconstruction and forensic engineering.

Source record↗

An Overview of Fires in Oxygen Systems

The presentation includes information about testing, space, aircraft, medical issues, oxygen production and distribution, cutting and welding, diving and deep sea, and hyperbaric chambers. Additional files include an NFPA Appendix, wrapup, supporting files from White Sands Testing Facility.

Stoltzfus, Joel M.↗

Medical science in Siberia: Oxygen exchange in the Far North

Differences in oxygen conditions between the native and migrant Siberian population were studied in relation to respiratory function, arterial and venous blood indicators and acid-base indicators. Significant adaptation differences were ascertained between the two populations.

Kulikov, V.↗

NESC Ceramic Oxygen Generator (COG) Technology Development

The NASA Engineering and Safety Center (NESC) sponsored a project to accelerate the pace of technology development of a ceramic oxygen generator (COG), for NASA and COVID related medical use. NASA applications for this technology include spacesuit oxygen tank recharge, medical applications include providing medical oxygen in remote and low resource settings. During this project, five full-scale (i.e., 30 wafer) cell stacks were built and tested in prototype systems capable of producing pressurized oxygen. System testing measured oxygen product purity, delivery pressure, production rate, and energy use. This report describes ion transport membrane mechanisms, cell stack configuration, and test results.

Oxygen↗

CPAP Ventilators Needed for Rapid Response to COVID-19 by Modification of CPAP Equipment

Early on in the COVID-19 pandemic, potential ventilator shortages were a critical issue identified by national health care providers. Capacity modeling at the time suggested patient demand may exceed ventilator supply. Thus, the challenge became finding an urgent interim solution to meet health care needs. Our initial hypothesis was that CPAP technology could be modified to provide similar functionality to a ventilator, relieving demand and allowing physicians to decide which patients need high end machines, ultimately saving lives. In conjunction with medical experts and pulmonologists, we were able to identify three key thrusts associated with this research problem: (1) modification of CPAP technology to allow for 02 input that would be capable of providing ventilation; (2) development of an alarming function that would provide real-time audible alarms to alert medical personnel to critical conditions, which would be used inline with CPAP technology; and (3) a method of sterilizing expiratory air from such a system in order to protect medical personnel from biohazard, since CPAPs vent to the atmosphere. We were unable to realize results for thrust 1 (CPAP modification for 02); we identified potential safety issues associated with utilizing medical grade oxygen with a common CPAP device. In order to characterize and mitigate these issues, we would need to partner closely with a device manufacturer; such a partnership could not be achieved in the timeframe needed for this rapid response work. However, we determined that some medical grade BiPAP devices do not need this modification and that the significant progress on thrusts 2 and 3 would be sufficient to buy down risk of a massive ventilator shortage. Our team built a prototype alarm system that can be utilized with any assistive respiratory device to alert on all key conditions identified by medical personnel (high pressure, low pressure, apnea, loss of power, low battery). Finally, our team made significant progress in the rapid prototyping and demonstration of an inline UV air purifier device. The device is cost efficient and can be manufactured at scale with both commercially available and additively manufactured parts. Initial tests with SARS-CoV-2 analog bacteriophage MS2 show 99% efficacy at reducing bioburden. Following a successful demonstration of the prototype device with medical personnel, we were able to obtain follow-on (non-LDRD) funding to provide additional device characterization, validation, and production in order to respond to an immediate regional need.

42 ENGINEERING↗

The novel Mechanical Ventilator Milano for the COVID-19 pandemic

This paper presents the Mechanical Ventilator Milano (MVM), a novel intensive therapy mechanical ventilator designed for rapid, large-scale, low-cost production for the COVID-19 pandemic. Free of moving mechanical parts and requiring only a source of compressed oxygen and medical air to operate, the MVM is designed to support the long-term invasive ventilation often required for COVID-19 patients and operates in pressure-regulated ventilation modes, which minimize the risk of furthering lung trauma. The MVM was extensively tested against ISO standards in the laboratory using a breathing simulator, with good agreement between input and measured breathing parameters and performing correctly in response to fault conditions and stability tests. The MVM has obtained Emergency Use Authorization by U.S. Food and Drug Administration (FDA) for use in healthcare settings during the COVID-19 pandemic and Health Canada Medical Device Authorization for Importation or Sale, under Interim Order for Use in Relation to COVID-19. Furthermore, following these certifications, mass production is ongoing and distribution is under way in several countries. The MVM was designed, tested, prepared for certification, and mass produced in the space of a few months by a unique collaboration of respiratory healthcare professionals and experimental physicists, working with industrial partners, and is an excellent ventilator candidate for this pandemic anywhere in the world

60 APPLIED LIFE SCIENCES↗

Effect of Molding and Machining on Neoflon CTFE M400H Polychlorotrifluoroethylene Rod Stock and Valve Seat Properties

Since 1997 numerous fires have been reported to the Food and Drug Administration involving cylinder valves installed on medical use oxygen cylinders sold and operated within the United States. All of the cylinder valves in question had polychlorotrifluoroethylene (PCTFE) valve seats. Subsequent failure analysis showed that the main seat was the primary source of ignition. A review of the incidents involving cylinder valve fires indicated three possible ignition mechanisms: contaminant promotion, flow friction, and resonance. However, gas purity analysis showed that uncombusted, residual oxygen was within specification. Infrared and energy dispersive spectroscopy further showed that no contaminants or organic compounds were present in the remaining, uncombusted valve seat material or on seat plug surfaces. Therefore, contaminant-promoted ignition did not appear to be responsible for the failures. Observations of extruded material along the outer edge of the coined or loaded seat area produced by cylinder overuse or poppet overload led to concerns that accelerated gas flow across a deformed seat surface could generate enough localized heating to ignite the polymeric seat. Low molecular weight or highly amorphous quick-quenched PCTFE grades might be expected to be especially prone to this type of deformation. Such a failure mechanism has been described as flow friction; however, the corresponding mechanistic parameters are poorly understood. Subsequent revelation of low-temperature dimensional instability by thermomechanical analysis (TMA) in a variety of PCTFE sheet and rod stock samples led to new concerns that PCTFE valve seats could undergo excessive expansion or contraction during service. During expansion, additional extrusion and accompanying flow friction could occur. During contraction, a gap between the seal and adjacent metal surfaces could form. Gas flowing past the gap could, in turn, lead to resonance heating and subsequent ignition as described in ASTM Guide for Evaluation Nonmetallic Materials for Oxygen Service (G 63). Attempts to uncover the origins of the observed dimensional instability were hindered by uncertainties about resin grade, process history, and post-process heat history introduced by machining, annealing, and sample preparation. An approach was therefore taken to monitor property changes before and after processing and machining using a single, well-characterized lot of Neoflon CTFE.1 M400H resin. A task group consisting of the current PCTFE resin supplier, two molders, and four valve seat manufacturers was formed, and phased testing on raw resin, intermediate rod stock, and finished valve seats initiated. The effect of processing and machining on the properties of PCTFE rod stock and oxygen gas cylinder valve seats was then determined. Testing focused on two types of extruded rod stock and one type of compression-molded rod stock. To accommodate valve seat manufacturer preferences for certain rod stock diameters, two representative diameters were used (4.8 mm (0.1875 in.) and 19.1 mm (0.75 in.)). To encompass a variety of possible sealing configurations, seven different valve seat types with unique geometries or machining histories were tested. The properties investigated were dimensional stability as determined by TMA, specific gravity, differential scanning calorimetry (DSC), compressive strength, zero strength time, and intrinsic viscosity. Findings are discussed in the context of polymer structure-process-property relationships whenever possible.

Waller, Jess M.↗

Evaluation of the Oxygen Concentrator Prototypes: Pressure Swing Adsorption Prototype and Electrochemical Prototype

An oxygen concentrator is needed to provide enriched oxygen in support of medical contingency operations for future exploration human spaceflight programs. It would provide continuous oxygen to an ill or injured crew member in a closed cabin environment. Oxygen concentration technology is being pursued to concentrate oxygen from the ambient environment so oxygen as a consumable resource can be reduced. Because oxygen is a critical resource in manned spaceflight, using an oxygen concentrator to pull oxygen out of the ambient environment instead of using compressed oxygen can provide better optimization of resources. The overall goal of this project is to develop an oxygen concentrator module that minimizes the hardware mass, volume, and power footprint while still performing at the required clinical capabilities. Should a medical event occur that requires patient oxygenation, the release of 100 percent oxygen into a small closed cabin environment can rapidly raise oxygen levels to the vehicles fire limit. The use of an oxygen concentrator to enrich oxygen from the ambient air and concentrate it to the point where it can be used for medical purposes means no oxygen is needed from the ultra-high purity (99.5+% O2) oxygen reserve tanks. By not adding oxygen from compressed tanks to the cabin environment, oxygen levels can be kept below the vehicle fire limit thereby extending the duration of care provided to an oxygenated patient without environmental control system intervention to keep the cabin oxygen levels below the fire limits. The oxygen concentrator will be a Food and Drug Administration (FDA) clearable device. A demonstration unit for the International Space Station (ISS) is planned to verify the technology and provide oxygen capability. For the ISS, the demonstration unit should not exceed 10 kg (approximately 22 lb), which is the soft stowage mass limit for launch on resupply vehicles for the ISS. The unit's size should allow for transport within the spacecraft to an ill crewmember. The user interface needs to be designed for ease of use by the local care provider and with consideration to the limited amount of training available to the astronaut corps for medical equipment and procedures.

Gilkey, Kelly M.↗

International Space Station (ISS) Gas Logistics Planning in the Post Shuttle Era

Over its life the International Space Station (ISS) has received gas (nitrogen, oxygen, and air) from various sources. Nitrogen and oxygen are used in the cabin to maintain total pressure and oxygen partial pressures within the cabin. Plumbed nitrogen is also required to support on-board experiments and medical equipment. Additionally, plumbed oxygen is required to support medical equipment as well as emergency masks and most importantly EVA support. Gas are supplied to ISS with various methods and vehicles. Vehicles like the Progress and ATV deliver nitrogen (both as a pure gas and as air) and oxygen via direct releases into the cabin. An additional source of nitrogen and oxygen is via tanks on the ISS Airlock. The Airlock nitrogen and oxygen tanks can deliver to various users via pressurized systems that run throughout the ISS except for the Russian segment. Metabolic oxygen is mainly supplied via cabin release from the Elektron and Oxygen Generator Assembly (OGA), which are water electrolyzers. As a backup system, oxygen candles (Solid Fuel Oxygen Generators-SFOGs) supply oxygen to the cabin as well. In the past, a major source of nitrogen and oxygen has come from the Shuttle via both direct delivery to the cabin as well as to recharge the ISS Airlock tanks. To replace the Shuttle capability to recharge the ISS Airlock tanks, a new system was developed called Nitrogen/Oxygen Recharge System (NORS). NIORS consists of high pressure (7000 psi) tanks which recharge the ISS Airlock tanks via a blowdown fill for both nitrogen and oxygen. NORS tanks can be brought up on most logistics vehicles such as the HTV, COTS, and ATV. A proper balance must be maintained to insure sufficient gas resources are available on-orbit so that all users have the required gases via the proper delivery method (cabin and/or plumbed).

Leonard, Daniel J.↗

Two Heat-Transfer Improvements for Gas Liquefiers

Two improvements in heat-transfer design have been investigated with a view toward increasing the efficiency of refrigerators used to liquefy gases. The improvements could contribute to the development of relatively inexpensive, portable oxygen liquefiers for medical use. A description of the heat-transfer problem in a pulse-tube refrigerator is prerequisite to a meaningful description of the first improvement. In a pulse-tube refrigerator in particular, one of in-line configuration heat must be rejected from two locations: an aftercooler (where most of the heat is rejected) and a warm heat exchanger (where a small fraction of the total input power must be rejected as heat). Rejection of heat from the warm heat exchanger can be problematic because this heat exchanger is usually inside a vacuum vessel. When an acoustic-inertance tube is used to provide a phase shift needed in the pulse-tube cooling cycle, another problem arises: Inasmuch as the acoustic power in the acoustic-inertance tube is dissipated over the entire length of the tube, the gas in the tube must be warmer than the warm heat exchanger in order to reject heat at the warm heat exchanger. This is disadvantageous because the increase in viscosity with temperature causes an undesired increase in dissipation of acoustic energy and an undesired decrease in the achievable phase shift. Consequently, the overall performance of the pulse-tube refrigerator decreases with increasing temperature in the acoustic-inertance tube. In the first improvement, the acoustic-inertance tube is made to serve as the warm heat exchanger and to operate in an approximately isothermal condition at a lower temperature, thereby increasing the achievable phase shift and the overall performance of the refrigerator. This is accomplished by placing the acoustic-inertance tube inside another tube and pumping a cooling fluid (e.g., water) in the annular space between the tubes. Another benefit of this improvement is added flexibility of design to locate the warm heat-rejection components outside the vacuum vessel. The second improvement is the development of a compact radial-flow condenser characterized by a very high heat transfer coefficient and a small pressure drop.

Martin, Jerry L.↗