At least 19 records

Long Term Per-Component Power and Thermal Measurements of the OLCF Summit System

As we move into the exascale era, the power and energy footprints of high-performance computing (HPC) systems have grown significantly larger. Due to the harsh power and thermal conditions the system, components are exposed to extreme operating conditions. Operation of such modern HPC systems requires deep insights into long term system behavior to maintain its efficiency as well as its longevity. To help the HPC community to gain such insights, we provide a dataset that records the long-term power and thermal behavior of the 200PF pre-exascale supercomputer at the Oak Ridge Leadership Computing Facility (OLCF), Summit. This system is an IBM AC922 based system that has 9,252 IBM Power9 CPUs and 27,756 Nvidia V100 GPUs and can consume up to 13MW power at peak. Heat removal is performed using medium temperature direct liquid cooling and rear-door heat exchanger based secondary cooling loop. Originally extracted from a high-resolution (1Hz) per-component (GPUs, CPUs) measurements from the system, we primarily provide a dataset that has 10-second and 1-minute mean power and thermal measurements selected from five month-long segments over the course of 2020 (January and August), 2021 (February and August), and 2022 (January). For convenience, we also provide various sub datasets randomly sampled from the time and space (hosts) of the cluster. Further details and example code for analysis can be found in the following GitHub repository: https://github.com/at-aaims/summit_power_and_thermal_data

97 MATHEMATICS AND COMPUTING↗

OLCF Summit Supercomputer GPU Snapshots During Double-Bit Errors and Normal Operations

As we move into the exascale era, the power and energy footprints of high-performance computing (HPC) systems have grown significantly larger. Due to the harsh power and thermal conditions the system, components are exposed to extreme operating conditions. Operation of such modern HPC systems requires deep insights into long term system behavior to maintain its efficiency as well as its longevity. To help the HPC community to gain such insights, we provide double-bit errors using system telemetry data and logs collected from the Summit supercomputer, equipped with 27,648 Tesla V100 GPUs with 2nd-generation high-bandwidth memory (HBM2). The dataset relies on Nvidia XID records internally collected by GPU firmware at the time of failure occurrence, on the reboot-time logs of each Summit node, on node-level job scheduler records collected after each job termination, and on a 1Hz data rate from the baseboard management controllers (BMCs) of each Summit compute node using the OpenBMC event subscription protocol. Technical details can be found in the paper Oles et. al “Understanding GPU Memory Corruption at Extreme Scale: The Summit Case Study” ICS’24 (https://doi.org/10.1145/3650200.3656615).

97 MATHEMATICS AND COMPUTING↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

From Chills to Thrills: Revolutionizing Energy Efficiency and Load Flexibility in Supermarket Refrigeration: Preprint

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Grid Interactive Micro-Distributed Refrigerated Display Case

Open-vertical medium-temperature refrigerated display cases comprise nearly 50% of total case lineups in a typical supermarket, with more than 80% of their cooling load attributed to infiltration of warm and moist air from the surrounding space. The infiltration takes place across the air curtain system of the display case. While the air curtain acts as a thermal shield and as a cooling mechanism to maintain product temperature, it also entrains large amounts of heat and moisture from the adjacent space. Additionally, from food safety and quality standpoints, these fixtures are vulnerable to electric outages and traditionally cannot participate in load flexibility events. This paper describes key features of an innovative design of a self-contained, water-cooled, medium-temperature, open-vertical display case. The novel concept will eliminate the inefficient air curtain system and incorporate a hybrid radiant and low-airflow convective cooling design with a thermal-energy-storage-coupled heat exchanger integrated into the refrigeration circuit. The focus of this paper is on evaluating the thermal performance of the novel hybrid design in maintaining target product temperature. It presents thermal performance findings from thermo-fluid system modeling and robust state-of-the-art laboratory experiments used to validate those models. Load flexibility attributes from thermal energy storage are not discussed. A controlled-environment chamber at the National Renewable Energy Laboratory was leveraged to validate the thermal performance of the novel technology. Final results from bench-scale experiments indicate the proposed design maintained mean product temperatures within food safety guidelines.

commercial refrigeration↗

Performance Evaluation of Liquid-Cooled Open Stand-Alone Refrigerated Cases

This project is part of a joint effort between Commonwealth Edison Company (ComEd) and the National Renewable Energy Laboratory (NREL) to evaluate the energy and demand savings potential of emerging efficient buildings technologies. This project quantifies the energy efficiency benefits from retrofitting an air-cooled, constant-speed compression, self-contained medium-temperature open-vertical display case with a high efficiency water-cooled condensing unit. In addition to a water-cooled heat rejection mechanism, the high-efficiency condensing unit utilizes a variable-speed compressor, electronic expansion valve and advanced controls system. The focus of this project, however, was mainly on capturing the energy savings potentials of the water-cooled condenser, variable-speed compression and electronic expansion valve, and not on the advanced controls. The results of this evaluation will be considered by ComEd and CLEAResult for future energy efficiency rebate offerings.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Novel PCM-based fin and tube heat exchanger system for building heating and cooling applications

In the United States, the building sector accounts for 40% of all energy use, and buildings are responsible for more than two-thirds of electricity consumption. Buildings remain the major driver of energy-related carbon emissions, and such emissions are projected to increase in the years ahead because of urbanization and population growth. To accomplish the low carbon energy goal in the building sector, phase change material (PCM)–based thermal energy storage (TES) is increasingly being adopted because it offers several advantages, such as reducing building peak load and energy consumption, enabling large scale deployment of renewables, and improving grid stability. The integration of TES with thermally anisotropic building envelopes (TABEs) is a promising solution because, TABE can redirect natural thermal energy from a building using hydronic loops to TES, and the stored energy can be used later for heating and cooling applications. In this study, we experimentally investigate the thermal performance of a novel fin-tube heat exchanger TES system designed for potential integration with a TABE. An experimental rig for a 5-gal PCM fin-tube heat exchanger system with water as the heat transfer medium is described which records temperatures at the heated and cooled boundaries of the system. Experimental observations provide insight into the role a TES system can play in offsetting a building’s heating and cooling demand and also offer a means to characterize the performance of PCMs for building applications. The scale and study presented in this work will help in the design of future thermal storage systems optimized for storage capacity while also accounting for overall system costs for building applications.

Tamraparni, Achutha↗

A comparative assessment of the economic viability of nuclear-integrated direct air capture systems

Direct air capture (DAC) systems require heat and electricity to operate, which can be supplied by nuclear power plants (NPPs). In this study, the performance and cost of various conceptual nuclear-DAC systems are assessed, and their performance is compared with several non-nuclear options. Three nuclear-DAC systems are considered: (1) a liquid solvent direct air capture (L-DAC) system with heat supplied from natural gas (NG) and electricity supplied by an NPP, (2) an electrified L-DAC system, fully powered by electricity from an NPP, and (3) a solid sorbent direct air capture (S-DAC) system utilizing both heat and electricity generated by an NPP. Two nuclear technologies are considered: a pressurized water reactor and a high-temperature gas-cooled reactor. Under the medium conservatism scenario, the levelized cost of direct air capture (LCOD) for these systems range from $\$$310/tCO 2 to $\$$525/tCO 2 with the L-DAC system having an NG heat supply at the lower end of the range, and the electrified L-DAC system and the S-DAC system at the higher end of the range. Coupling with nuclear energy led to a 21 % reduction in LCOD for the L-DAC system with NG heat supply and a 29 % reduction for the S-DAC system when compared to fully NG-powered options. When powering the DAC system with grid electricity, the LCOD is highly dependent on the assumed electricity price and carbon intensity. The nuclear option is the cheaper choice when the price of low-carbon grid electricity exceeds $\$$95/MWh and $\$$45/MWh for the L-DAC and S-DAC systems, respectively.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

Efficient Refrigerated Display Cases - Can They Flex Their Power? Preprint

Refrigerated display cases are widely-used, critical equipment in supermarkets for maintaining product safety and quality. Energy-efficient medium temperature liquid-cooled refrigerated display cases can save 25-70% of the total supermarket energy, according to manufacturers. Traditionally, cases operate by maintaining a temperature around a user-input setpoint that is dependent on the product in the case. Although cases are major electrical energy consumers, they are hardly ever considered for implementing load-flexibility strategies. With added load-flexibility capabilities, refrigerated display cases can shed (reduce), or shift (by adding and subsequently shedding) load. Supermarkets can reduce their energy costs and enhance electric grid integrity by implementing these smart load-flexibility control strategies. Advanced controls can also enable load-shifting to coincide with optimum periods of renewable energy generation. This will further improve operational costs and reduce greenhouse gas emissions without compromising food safety and quality. In this research, we have evaluated the energy savings of liquid-cooled medium temperature display cases and developed load flexibility strategies leveraging an advanced controls system, a variable speed compressor, and heat rejection via a water-cooled condenser. This study further assessed the impact of load flexibility strategies in a controlled environment chamber for a single refrigerated display case.

ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATION↗

An Innovative Zero-Liquid Discharge Intermediate-Cold-Liquid Eutectic-Freeze Desalination System

A novel freeze desalination technology is presented for purification of water produced from various industrial processes, including oil and gas extraction. The main innovative idea is introducing a water-immiscible intermediate-cold-liquid (ICL) medium which absorbs the cold from a refrigeration cycle and transfers it to a freezing chamber where it is mixed with brine. The cold ICL enters the freezing chamber at temperatures between -10°C to -30°C. Precooled brine in injected into the freezing chamber and pure water freezes out of the brine upon mixing with the ICL. The rate of freezing inside the chamber is controlled by adjusting the flow rate of the cold ICL relative to the inlet brine. Both eutectic freeze and non-eutectic freezing are possible by controlling the temperature of the freezing chamber. The solid-liquid slurry created in the freezing chamber flows to a filter separation unit after passing through a separation column. The ice crystals are separated from the liquid by a rotary filter device. The collected ice is rinsed by a centrifugal unit. The rinsed ice is melted to produce fresh water. The developed technology resolves the issues common to current freeze-desalination systems while offering superior heat transfer performance ascribed to direct-contact between the cooling medium and the brine in addition to producing solid salt and pure water. The system operates under atmospheric pressure. The low operation temperature minimizes the corrosion issues common in systems exposed to brine. Also, due to the low operating temperature, there are no concerns about evaporation of volatile organics from the produced water during the treatment. The developed technology effectively eliminates the use of chemicals for pretreatment of brine. The system can be constructed from commercially available components. Extensive testing using a lab-scale prototype by using synthetic brine and actual produced water with TDS values from 50,000 ppm to 300,000 ppm showed that freshwater could be achieved with relatively small dependency on the quality of the input brine. The quality of the treated water was found to be mainly a function of the duration of the centrifugal process. Treated water with TDS as low as 200 ppm could be achieved in the tests. Thermo-economic modeling coupled with system level thermochemical process model were developed for prediction of the LCOW. The LCOW was predicted to be $\$$0.50 to $\$$0.90 per barrel of produced water. The potential markets for deployment of the technology are the oil and gas, in-land thermoelectric powerplants, RO desalination plants, and mining industry.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Technoeconomic assessment of distillation heat transfer intensification using aeroelastically fluttering reeds

Dry cooling, where forced air is the heat transfer medium, is a preferable cooling method in arid locations lacking readily available process water. However, such locations often experience high ambient temperatures that limit the effectiveness of air cooling. The objective of this study is to quantify the economic and energetic benefits of heat transfer intensification via the implementation of aeroelastically fluttering reeds to the air-cooled condenser of a methanol distillation column. Condenser size and performance, regarding recovered methanol and required fan power, is evaluated across condenser operating temperatures (T cond ) from 60 to 62°C and heat transfer coefficients (U) U base –2U base for a range of inlet air temperatures based on ambient temperature data from Yuma, Arizona. Under typical design sizing, condenser capital cost was reduced by 6%–35% (1.3U base –2U base ) and nominal methanol recovery was increased from 0.26% to 0.38% (T cond = 62–60°C). At optimized condenser size, all enhanced U and T cond pairs increase methanol recovery and reduce fan power costs compared to the optimal Ubase reference. Overall, using enhanced heat transfer to maintain condenser temperature under a wider range of inlet conditions, rather than to reduce operation temperature, produces more favorable performance. Methanol price is not a determining factor in which pairs are profitable. Analysis was repeated for a global warming scenario, revealing more valuable improvements under elevated temperatures. Energy savings from condenser improvement to a methanol production system are not significant with respect to an optimized conventional system. Furthermore, unit economic and energetic incentives suggest implementation of fluttering reeds may be justified in other applications.

42 ENGINEERING↗

3D probabilistic fracture mechanics / computational fluid dynamics simulation of a reactor pressure vessel under transient conditions

Reactor pressure vessels (RPVs) are safety-critical light-water-reactor components that, under irradiation, experience long-term material degradation in the form of embrittlement. This can increase their susceptibility to fracture under thermal-shock conditions, which could occur during off-normal transients such as loss-of-coolant accidents (LOCAs). During a LOCA, the most severe conditions for the RPV occur when emergency core cooling water is injected through the cold legs into the water-and-steam-filled RPV. The rapid cooling of the downcomer and internal RPV surface causes decreased temperature and elevated thermally driven tensile stresses in the RPV wall. This, combined with long-term material embrittlement, may cause fracture initiation at pre-existing flaws, challenging the integrity of the RPV. Assessing RPV integrity during transients with a large spatial variation in the coolant temperature requires a modeling approach that considers the effects of spatially varying coolant temperature on the fracture probability of a population of flaws distributed throughout the RPV, accounting for spatially varying embrittlement. Here, the present study addresses this need by demonstrating first-of-its-kind coupling of a high-fidelity 3D computational fluid dynamics code with 3D probabilistic fracture mechanics This was accomplished using representative models of a pressurized-water reactor subjected to small- and medium-break LOCA conditions, both of which can result in large spatial temperature variations. While the observed impact of accounting for 3D effects was minimal under the small-break LOCA this study indicates a significant increase in the probability of fracture initiation under the medium-break LOCA when 3D effects are considered, relative to a spatially uniform cooling scenario.

22 - GENERAL STUDIES OF NUCLEAR REACTORS↗

A first and second law analysis of a thermoresponsive polymer desiccant dehumidification and cooling cycle

Herein, we present a theoretical description for a new desiccant air conditioning cycle that uses thermoresponsive polymers instead of traditional desiccants. We use a combined first and second law analysis to demonstrate that this new cycle has three major advantages relative to the traditional case: (i) it can regenerate at lower temperatures, (ii) it can harvest liquid water and (iii) it has significantly higher coefficients of performance (COPs). For example, this new cycle can achieve a COP of 5.1 when regenerated at 95 degrees C, whereas the traditional desiccant cycle is limited to a COP of ~ 1. The fundamental origins of these advantages can be traced to the method of regeneration. The traditional desiccant cycle regenerates by flowing hot air over the desiccant, which provides a medium for gaseous water desorption. However, this also generates entropy and places a minimum temperature constraint on the hot air. In contrast, the thermoresponsive polymer cycle regenerates through a polymer phase transition. The polymer absorbs water vapor in humid air, and then it expels liquid water when raised above its transition temperature. This regeneration method generates liquid water that can be harvested and relaxes constraints on entropy generation and minimum temperature. The minimum regeneration temperature of the thermoresponsive cycle is only limited by the transition temperature of the polymer, which can be tuned through materials science. Due to its liquid water harvesting capability, the new cycle potentially eliminates water consumption when used with evaporative cooling, or it can be directly used for atmospheric water harvesting.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Characterization of Alloy 709 Commercial Heats

The creep-resistant austenitic stainless steel Alloy 709 (Fe-20Cr-25Ni (wt%) based steel) is being investigated as a candidate structural material for the next generation of advanced reactors. Unlike conventional solid solution strengthened austenitic stainless steels, Alloy 709 develops a variety of precipitates during aging at different temperatures and times. In this study, precipitate evolution during short-term aging at 775°C was characterized. The effect of aging time (e.g., 10 vs. 100 hours) and cooling after aging (e.g., water quench vs. air cool) on grain size and precipitates have been investigated using light optical microscopy (OM), electron backscatter diffraction (EBSD), transmission electron microscopy (TEM), and energy-dispersive X-ray spectroscopy (EDS). MX (Ni,Tb)(C,N) and M23C6 (Cr,Mo)C precipitates were observed in all the statically-aged samples. The grain size distribution in the sample aged for 10 hours and water quenched (10Q) versus the one aged for 100 hours and air cooled (100A) were comparable. This indicates that grain structure was fairly stable when aging at 775°C for up to 100 hours. In contrast, the sample aged for 10 hours and air cooled (10A) showed the smallest and the most uniform grain size distribution. This phenomenon was observed in only one sample. More studies on duplicate samples are needed to confirm the results obtained. The cooling medium (e.g., water quench vs. air cool) was not observed to impact the size nor the distribution of the MX and M23C6 precipitates. Increasing the aging time resulted in the following: (1) a decrease in dislocations as well as the number density of small precipitates; (2) an increase in the ratio of free precipitates that were not pinning dislocations; (3) relatively higher N, Nb, and Ti concentration in MX precipitate; (4) some increase in length of M23C6 carbides which were located on the coherent boundaries; and (5) the introduction of Sienriched M6X precipitates. The tensile tests at room temperature showed similar properties for each of the static aging treatments, indicating that the differences observed in the microstructural analysis did not have a significant impact on the tensile properties.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Data for Metabolic Engineering of β-Oxidation to Leverage Thioesterases for Production of 2-Heptanone, 2-Nonanone, and 2-Undecanone

Medium-chain length methyl ketones are potential blending fuels due to their cetane numbers and low melting temperatures. Biomanufacturing offers the potential to produce these molecules from renewable resources such as lignocellulosic biomass. In this work, we designed and tested metabolic pathways in Escherichia coli to specifically produce 2-heptanone, 2-nonanone and 2-undecanone. We achieved substantial production of each ketone by introducing chain-length specific acyl-ACP thioesterases, blocking the β-oxidation cycle at an advantageous reaction, and introducing active β-ketoacyl-CoA thioesterases. Using a bioprospecting approach, we identified 15 homologs of E. coli β-ketoacyl-CoA thioesterase (FadM) and evaluated the in vivo activity of each against various chain length substrates. The FadM variant from Providencia sneebia produced the most 2-heptanone, 2-nonanone, and 2-undecanone, suggesting it has the highest activity on the corresponding β-ketoacyl-CoA substrates. We tested enzyme variants, including acyl-CoA oxidases, thiolases, and bi-functional 3-hydroxyacyl-CoA dehydratases to maximize conversion of fatty acids to β-keto acyl-CoAs for 2-heptanone, 2-nonanone, and 2-undecanone production. In order to address the issue of product loss during fermentation, we applied a 20% (v/v) dodecane layer in the bioreactor and built an external water cooling condenser connecting to the bioreactor heat-transferring condenser coupling to the condenser. Using these modifications, we were able to generate up to 4.4 g/L total medium-chain length methyl ketones.

Metabolic Engineering↗

Elucidating molecular scale interactions underlying the freezing behavior of salt solutions in silica nanopores

Elucidating the influence of nanoscale confinement on the freezing behavior of salt solutions is of fundamental interest to environmental security and materials science and engineering. Specific structural information such as the coordination environment of ions in confined aqueous medium, effects on the extended hexagonal network of water molecules and their mutual non-bonding interactions in confinement are sparse in the literature along with the change in the dynamical characteristics of water in the presence of ions. To address these knowledge gaps, the current study is focused on investigating the influence of reduced dimensionality arising from nanoscale confinement on the structural evolution of salt solutions on freezing and the associated fluid–surface interactions. In this regard, operando wide-angle X-ray scattering (WAXS) measurements and classical molecular dynamics (MD) simulations are conducted with water and 0.5 M CaCl 2 , MgCl 2 and KCl solutions confined in 4 nm sized SBA-15 silica pores upon cooling from 300 K to 200 K. The freezing point of the salt solutions is depressed to 235 K which is about 10 K lower than that of confined water. The translational dynamics of confined salt solutions indicates shifts in the fragile-to-strong dynamical crossover to a lower temperature compared to pure water. The strong electrostatic attraction between the cations and the surrounding water molecules contributes to the freezing point depression in confined salt solutions. These insights unlock the molecular-scale basis and mechanisms underlying the freezing behavior of confined salt solutions.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Energy Saving Estimation of ASHRAE Guideline 36 Supervisory Setpoint Reset Controls in a Commercial Large Office Building

Designing, commissioning, and retrofitting HVAC control systems for energy efficiency is crucial, but the use of ad-hoc control sequences by designers and contractors, based on scattered information, results in diverse and sub-optimal sequences. ASHRAE Guideline 36 (G36) addresses the challenge by providing standardized, rule-based HVAC control sequences that prioritize energy efficiency. However, there is limited evaluation of their energy performance at the building level, with only a few studies primarily focused on HVAC airside systems in small-to-medium-sized commercial buildings. In this study, the energy performance of ASHRAE Guideline 36 control sequences was assessed using a large office building emulator in Chicago. The emulator features a central plant system with multiple chillers and boilers as well as multiple variable air volume (VAV) systems with terminal reheat. To achieve a high-fidelity representation, we developed a Spawn-of-EnergyPlus-based model for the large office building, maintaining the DOE prototype large office building setup but substituting the HVAC system with its Modelica counterpart. This substitution ensures that the building thermal load, HVAC system's dynamics, and detailed control sequences are all accurately represented. The study involved evaluating and implementing control strategies outlined in ASHRAE Guideline 36-2021 to replace conventional controls. These strategies include the demand-based supply air temperature and duct static pressure setpoint reset and the request logic for demand-based reset of chilled/hot water supply temperature setpoints and pipe static pressure setpoints. Energy performance was evaluated under various load conditions, including cooling, heating, and transitional seasons, both for individual control strategies and in combination. The results indicate that the collective control strategies retrofit yield greater energy savings than the sum of individual strategies, highlighting the synergistic benefits of incorporating both airside and plant-side control retrofits. Additionally, energy savings of up to 41% in the heating season, 18% in the shoulder season, and 20 % in the cooling season were observed compared to baseline control while maintaining the thermal comfort level.

ASHRAE Guideline 36, Commercial buildings, Control↗

Adiabatic and radiative cooling are both important causes of aerosol activation in simulated fog events in Europe

Aerosol–fog interactions affect the visibility in, and life cycle of, fog and are difficult to represent in weather and climate models. Here we explore processes that impact the simulation of fog droplet number concentrations (N d ) at sub-kilometer scale horizontal grid resolutions in the UK Met Office Unified Model. We modify the parameterization of aerosol activation to include droplet activation by radiative cooling in addition to adiabatic cooling and determine the relative importance of the two cooling mechanisms. We further test the sensitivity of simulated N d to: (a) interception of droplets by trees and buildings, (b) overestimation of updrafts in temperature inversions (which leads to artificially high N d values), and (c) potential mechanisms for droplet deactivation due to downward fluctuations in supersaturation. We evaluate our model against observations from the ParisFog and LANFEX field campaigns, building on evaluation described in the companion paper. Including radiative cooling in the activation mechanism improves how accurately we represent the liquid water path and the vertical structure of the fog in our LANFEX case study. However, with radiative cooling, the N d are overestimated for most of the ParisFog cases and for the LANFEX case. The time-averaged overestimate exceeds a factor of three (the normalized mean bias factor exceeds 2.0) in 4 out of 11 ParisFog cases. Our sensitivity studies demonstrate how these overestimates can be mitigated. Assuming the overestimate affects both radiative and adiabatic cooling, we find that although radiative cooling is more often the dominant source, both cooling sources can sometimes dominate activation.