Search NASA⌕ Search

SEARCH · Search NASA

Results for “metal detection”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Systems and methods for detecting metal ion concentrations in subjects

A method of selective detection of a concentration of a metal ion species in a subject is provided in which a biofluid sample is obtained from the subject. The biofluid sample is exposed to a functionalized porous aromatic polymer. The polymer selectively captures and concentrates the metal ion species from the biofluid. Subsequently, the biofluid is washed from the polymer. The polymer is then exposed to a solution comprising a colorimetric indicator that extracts the metal ion species from the washed polymer thereby changing a color of the solution as a function of an amount of the metal ion species in the polymer. The concentration of the metal ion species in the subject is then spectroscopically determined from the color of the solution.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Applying Anodic Stripping Voltammetry to Complex Wastewater Streams for Rapid Metal Detection (Final Report)

The overall objective of this project is the development of a lab-on-a-chip (LOC) electrochemical sensor capable of accurately measuring heavy metal (lead (Pb), cadmium (Cd), and arsenic (As)) concentrations in complex aqueous streams such as wastewater. The specific goals include: i) identify how heavy metal speciate and transform during the different stages of the wastewater treatment train, and explore pre-treatment methods that will de-complex heavy metals, making them available to ASV, ii) develop appropriate electrodes for ASV using organic/inorganic nanomaterials, and iii) integrate pre-treatment steps and specialized electrodes into an LOC sensor device capable of autonomously determining heavy metal concentrations in complex wastewater streams.

99 GENERAL AND MISCELLANEOUS↗

Unimodal Imaging of Monovalent Metal-Chelator Complexes and Lipids by MALDI Imaging Mass Spectrometry

Careful regulation of monovalent metal ions (M + ) is necessary to maintain a functional cellular system. Of these ions, appropriate sodium (Na + ) and potassium (K + ) concentrations are particularly integral for electrochemical signaling, as well as the secondary transport of nutrients and waste. Dysregulation of M + homeostasis can disrupt these mechanisms, potentially influencing the metabolism of downstream biomolecules such as lipids. Thus, the relationship between M + abundances and related biomolecular distributions must be elucidated to better understand the physiology of healthy and disordered tissues. Traditional techniques for imaging biological metal distributions include SIMS, LA-ICP-MS, and XRF; however, these capabilities are limited to elemental analysis or the analysis of molecular fragments and must be paired with other modalities to visualize distributions of more complex biomolecules within the same or similar samples. Conversely, matrix-assisted laser desorption/ionization imaging mass spectrometry (MALDI IMS) is a powerful tool often used for mapping such biomolecular distributions, but current methods are unable to detect metals within tissue. This study illustrates a novel methodology that adds metal detection to the MALDI IMS repertoire through which the simultaneous detection of M + metals and lipids is achievable. Using a robotic sprayer for homogeneous application, on-tissue deposition of the chelator deferiprone (DEF) enables subsequent detection of the ionizable metal-chelator complex by MALDI without hindering lipid detection. Our work provides proof-of-concept data for the simultaneous detection of K + , Na + , and intact lipids using MALDI IMS.

59 BASIC BIOLOGICAL SCIENCES↗

You Only Look Once v5 and Multi-Template Matching for Small-Crack Defect Detection on Metal Surfaces

This paper compares the performance of Deep Learning (DL) and multi-template matching (MTM) models for detecting small defects. DL models extract distinguishing features of objects but require a large dataset of images. In contrast, alternative computer vision techniques like MTM need a relatively small dataset. The lack of large datasets for small metal-surface defects has inhibited the adoption of automation in small-defect detection in remanufacturing settings. This motivated this preliminary study to compare template-based approaches, like MTM, with feature-based approaches, such as DL models, for small-defect detection on an initial laboratory and remanufacturing industry dataset. This study used You Only Look Once v5 (YOLOv5) as the DL model and compared its performance against the MTM model for small-crack detection. The findings of our preliminary investigation are as follows: (i) YOLOv5 demonstrated higher performance than MTM in detecting small cracks; (ii) an extra-large variant of YOLOv5 outperformed a small-size variant; (iii) the size and object variety of the data are crucial in achieving robust pre-trained weights for use in transfer learning; and (iv) enhanced image resolution contributes to precise object detection.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

From Quantum to Classical: Sensing Materials, Methods, and Platforms for Energy

This presentation covers several ongoing sensors projects at NETL, including the use of quantum sensors for energy sector applications (e.g. infrastructure monitoring, critical metal detection, grid modernization) as well as NETL-developed materials and platforms for detecting economically critical metals including rare earth elements, cobalt, and aluminum. Taken together, these projects demonstrate NETL's leadership in unleashing American energy through the development of high performance sensors for reliable energy production and consumption.

critical minerals↗

Utilization of Data Augmentation Techniques in Automated Inspection Systems for Defect Detection in Metals With Limited Data

Accurate identification of defects on metal surfaces is of great interest to many industry sectors, such as the automotive and aerospace industries. In contrast to conventional manual inspection techniques, recent automated inspection systems employ deep learning models trained to detect defects rapidly and precisely. The development of these models often requires a substantial image dataset to acquire adequate knowledge of defect features and enhance their predictive accuracy. When data is limited, augmentation techniques are often used to improve the precision and accuracy of defect detection systems. This study examined the prediction performance of two object detection models, namely Faster Region‐based Convolutional Neural Network (Faster R‐CNN) and You Only Look Once version 8 (YOLOv8), to identify dent defects in limited images of cast iron cylinder head surfaces. The original image set contains 46 images with 563 dents. To overcome limited data availability, common image augmentation techniques along with a copy‐paste method were applied. Results show that standard augmentation improved YOLOv8 accuracy by 8.00% and average precision (AP) by 3.00%. On the other hand, the copy‐paste technique achieved a 20.00% increase in accuracy and a 1% increase in AP with just 200 synthetic dents. Furthermore, these results provide support for using the copy‐paste augmentation strategy to enhance defect detection performance, with a limited dataset, contributing to more accurate defect identification in remanufacturing processes.

36 MATERIALS SCIENCE↗

Using 2.5D super-resolution to improve flaw detection in metal additive manufacturing parts

Industrial X-ray computed tomography (XCT) enables non-destructive inspection of additively manufactured (AM) parts, but high-resolution scanning requires long acquisition times and significant computational resources, limiting throughput in production environments. Super-resolution techniques can recover high-resolution information from low-resolution scans, but existing methods face a trade-off between 2D approaches that ignore inter-slice information and 3D methods that are computationally prohibitive for practical deployment. To address this trade-off, we propose a 2.5D deep learning-based super-resolution approach that uses seven neighbouring low-resolution slices to super-resolve the centre slice. This work evaluates the method on real XCT scans of steel AM parts, comparing reconstruction quality and flaw detection performance of 2D, 2.5D, and 3D ESRGAN-based super-resolution methods. Results demonstrate that 2.5D super-resolution significantly improves detection of small, process-induced flaws (e.g. porosity) compared to 2D methods, while avoiding the prohibitive computational burden of full 3D approaches. These findings provide initial evidence of 2.5D super-resolution as a practical, deployable solution for improving flaw detection in high-throughput industrial XCT inspection.

X-ray CT↗

Identification of Metal Stresses in Arabidopsis thaliana Using Hyperspectral Reflectance Imaging

Industrial accidents, such as the Fukushima and Chernobyl disasters, release harmful chemicals into the environment, covering large geographical areas. Natural flora may serve as biological sensors for detecting metal contamination, such as cesium. Spectral detection of plant stresses typically employs a few select wavelengths and often cannot distinguish between different stress phenotypes. In this study, we apply hyperspectral reflectance imaging in the visible and near-infrared along with multivariate curve resolution (MCR) analysis to identify unique spectral signatures of three stresses in Arabidopsis thaliana : salt, copper, and cesium. While all stress conditions result in common stress physiology, hyperspectral reflectance imaging and MCR analysis produced unique spectral signatures that enabled classification of each stress. As the level of potassium was previously shown to affect cesium stress in plants, the response of A. thaliana to cesium stress under variable levels of potassium was also investigated. Increased levels of potassium reduced the spectral response of A. thaliana to cesium and prevented changes to chloroplast cellular organization. While metal stress mechanisms may vary under different environmental conditions, this study demonstrates that hyperspectral reflectance imaging with MCR analysis can distinguish metal stress phenotypes, providing the potential to detect metal contamination across large geographical areas.

multivariate curve resolution↗

Soil Sample Plan in Support of the Site 300 Explosives Waste Treatment Facility Ecological Risk Assessment Pursuant to the Hazardous Waste Facility Permit, Part V, Special Condition #14 a-f. August 2020

The Department of Toxic Substances Control issued the Final Hazardous Waste Facility Permit to Lawrence Livermore National Laboratory, Site 300 in 2017. As part of the continual process to ensure waste treatment emissions are not impacting ecological receptors, LLNL analyzed soil samples in the vicinity of the Explosive Waste Treatment Facility (EWTF) Burn Units (i.e., Burn Cage and Burn Pan) and the Detonation Pad. Soil samples were analyzed by EPA Solid Waste 846 Methods for furans, explosives, metals, and semivolatile compounds. In all samples, furans, explosives, and semi-volatile organic compounds were not detected. Metals were detected at concentrations below background levels. This soil sample plan will sample the same four downwind areas of the Burn Units and the same downwind areas of the Detonation, as well as including four new sample locations. The four new locations will be located to the northeast and southwest of the Burn Units and Detonation (as shown in Figure 3). The constituents to be analyzed are in Tables 2 and 3. Perchlorate was not identified as a constituent of concern in the 2007 Soil Sampling Plan. However, for this plan, all soil samples will be analyzed for perchlorate. After completion of the sampling event, a soil sample report will be submitted to DTSC in accordance with requirements specified in the Hazardous Waste Facility Permit, Part V, Special Conditions 16 a-f. This proposed soil sampling plan will be fully implemented no later than one year after receiving DTSC approval, in accordance with the Hazardous Waste Facility Permit, Part V, Special Condition 15.

54 ENVIRONMENTAL SCIENCES↗

Soil Sample Workplan in Support of the Site 300 Explosives Waste Treatment Facility Ecological Risk Assessment Pursuant to the Hazardous Waste Facility Permit (Part V, Special Condition #14 a-f)

The Department of Toxic Substances Control issued the Final Hazardous Waste Facility Permit to Lawrence Livermore National Laboratory, Site 300 in 2017. As part of the continual process to ensure waste treatment emissions are not impacting ecological receptors, LLNL analyzed soil samples in the vicinity of the Explosive Waste Treatment Facility (EWTF) Burn Units (i.e., Burn Cage and Burn Pan) and the Detonation Pad. Soil samples were analyzed by EPA Solid Waste 846 Methods for furans, explosives, metals, and semi-volatile compounds. In all samples, furans, explosives, and semi-volatile organic compounds were not detected. Metals were detected at concentrations below background levels. This soil sample plan will sample the same four downwind areas of the Burn Units and the same downwind areas of the Detonation, as well as including four new sample locations. The four new locations will be located to the northeast and southwest of the Burn Units and Detonation (as shown in Figure 3). The constituents to be analyzed are in Tables 7 and 8. Perchlorate was not identified as a constituent of concern in the 2007 Soil Sampling Plan. However, for this plan, all soil samples will be analyzed for perchlorate. Nitrate and all CAM17 metals have been added to the sampling plan to comply with DTSC comments received in correspondence dated June 4, 2021. After completion of the sampling event, a soil sample report will be submitted to DTSC in accordance with requirements specified in the Hazardous Waste Facility Permit, Part V, Special Conditions 16 a-f. This proposed soil sampling plan will be fully implemented no later than one year after receiving DTSC approval, in accordance with the Hazardous Waste Facility Permit, Part V, Special Condition 15.

45 MILITARY TECHNOLOGY, WEAPONRY, AND NATIONAL DEF↗

Electrical sensing, tracking, and actuation of droplets

Devices, techniques, and processes are disclosed that use electrical impedance to detect of the presence and contents of droplets including cells, nucleic acids, proteins, or solute concentrations in an array of retrievable, trackable, trapped droplets in a fluidic system. Electrodes may be positioned underneath individual droplet traps in a microchannel to assay droplet contents and/or actuating droplets for the release of the droplets from corresponding traps. The disclosed technology may be used for detection of the results of solvent extraction processes including time-dependent quantification of metal ion concentration in the aqueous and organic phases, for wastewater treatment, heavy metal detection, pharmaceutical industry, and/or biotechnology, or for environmental monitoring of wastewater for toxic metal, monitoring of biological cell viability and proliferation, monitoring of extraction processes used in heavy metal mining, monitoring of extraction processes used in nuclear fuel processing, monitoring kinetics of enzyme processes, and/or assessing pharmacodynamics and drug efficacy.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Trace metal transfer to passerines inhabiting wastewater treatment wetlands

Wastewater treatment wetlands are cost-effective strategies for remediating trace metals in industrial effluent. However, biogeochemical exchange between wastewater treatment wetlands and adjacent environments provides opportunities for trace metals to cycle in surrounding ecosystems. The transfer of trace metals to wildlife inhabiting treatment wetlands must be considered when evaluating wetland success. Using passerine birds as bioindicators, we conducted a multi-tissue analysis to investigate the mobilization of zinc, copper, and lead derived from wastewater to terrestrial wildlife in treatment wetlands and surrounding habitat. In addition, we evaluate the strength of relationships between metal concentrations in non-lethal (blood and feathers) and lethal (muscle and liver) sample types for estimation of toxicity risk. From July 2020 to August 2021, 177 passerines of seven species were captured at two wetlands constructed to treat industrial wastewater and two reference wetlands in the coastal plain of South Carolina. Feather, blood, liver, and muscle samples from each bird were analyzed for fourteen metals using inductively coupled plasma mass spectrometry and direct mercury analysis. Passerines inhabiting wastewater treatment wetlands accumulated higher concentrations of zinc in liver, copper in blood, and lead in feathers than passerines in reference wetlands, but neither blood nor feather concentrations were correlated with internal tissue concentrations. Of all the detected metals, only mercury in the blood showed a strong predictive relationship with mercury in internal tissues. This study indicates that trace metals derived from wastewater are bioavailable and exported to terrestrial wildlife and that passerine biomonitoring is a valuable tool for assessing metal transfer from treatment wetlands. Furthermore, regular blood sampling can reveal proximate trace metal exposure but cannot predict internal body burdens for most metals.

63 RADIATION, THERMAL, AND OTHER ENVIRON. POLLUTAN↗

Multiplexed Anodic Stripping Voltammetry Detection of Heavy Metals in Water Using Nanocomposites Modified Screen-Printed Electrodes Integrated With a 3D-Printed Flow Cell

In this study, we present multiplexed anodic stripping voltammetry (ASV) detection of heavy metal ions (HMIs)—As(III), Cd(II), and Pb(II)—using a homemade electrochemical cell consisting of dual working, reference and counter screen-printed electrodes (SPE) on polyimide substrate integrated with a 3D-printed flow cell. Working and counter electrodes were fabricated by the screen-printing of graphite paste while the Ag/AgCl paste was screen-printed as a reference electrode (Ag/AgCl quasi-reference electrode). The working electrodes were modified with (BiO) 2 CO 3 -reduced graphene oxide (rGO)-Nafion [(BiO) 2 CO 3 -rGO-Nafion] and Fe 3 O 4 magnetic nanoparticles (Fe 3 O 4 MNPs) decorated Au nanoparticles (AuNPs)-ionic liquid (IL) (Fe 3 O 4 -Au-IL) nanocomposites separately to enhance HMIs sensing. Electrochemical detection was achieved using square wave ASV technique. The desired structure of the flow electrochemical cell was optimized by the computational fluid dynamic (CFD). Different experimental parameters for stripping analysis of HMIs were optimized including deposition time, deposition potential and flow rate. The linear range of calibration curves with the sensing nanocomposites modified SPE for the three metal ions was from 0–50 μg/L. The limits of detection (S/N = 3) were estimated to be 2.4 μg/L for As(III), 1.2 μg/L for Pb(II) and 0.8 μg/L for Cd(II). Furthermore, the homemade flow anodic stripping sensor platform was used to detect HMIs in simulated river water with a 95–101% recovery, indicating high selectivity and accuracy and great potential for applicability even in complex matrices.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

RESULTS OF A VIRTUAL ROUND ROBIN STUDY TO ESTIMATE PROBABILITY OF DETECTION FOR DISSIMILAR METAL WELDS

This paper presents efforts to overcome challenges with empirical probability of detection (POD) estimations in the nuclear power industry through the utilization of a novel virtual flaw method. A virtual round robin (VRR) study was conducted under the Program for Investigation Of NDE by International Collaboration (PIONIC), organized by the United States Nuclear Regulatory Commission (NRC) utilizing data generated by the virtual flaw method. Analysis of results from the VRR was performed by teams from Pacific Northwest National Laboratory (PNNL), Electric Power Research Institute (EPRI), and Aalto University. Empirically derived POD estimations are presented, and challenges associated with obtaining these estimations are discussed. The virtual flaw method is introduced and some details of its implementation for the VRR activity are described. Results from POD analysis of the VRR data by PNNL, EPRI, and Aalto University are presented and a discussion regarding differences in analysis results is provided. Finally, potential future efforts to improve the application of the virtual flaw method and its estimation of POD are discussed.

Probability of detection, Dissimilar Metal Weld, P↗

The R -process Alliance: A Nearly Complete R -process Abundance Template Derived from Ultraviolet Spectroscopy of the R -process-enhanced Metal-poor Star HD 222925 *

We present a nearly complete rapid neutron-capture process (r-process) chemical inventory of the metal-poor ([Fe/H] = -1.46 ± 0.10) r-process-enhanced ([Eu/Fe] = +1.32 ± 0.08) halo star HD 222925. This abundance set is the most complete for any object beyond the solar system, with a total of 63 metals detected and seven with upper limits. It comprises 42 elements from 31 ≤ Z ≤ 90, including elements rarely detected in r-process-enhanced stars, such as Ga, Ge, As, Se, Cd, In, Sn, Sb, Te, W, Re, Os, Ir, Pt, and Au. We derive these abundances from an analysis of 404 absorption lines in ultraviolet spectra collected using the Space Telescope Imaging Spectrograph on the Hubble Space Telescope and previously analyzed optical spectra. A series of appendices discusses the atomic data and quality of fits for these lines. The r-process elements from Ba to Pb, including all elements at the third r-process peak, exhibit remarkable agreement with the solar r-process residuals, with a standard deviation of the differences of only 0.08 dex (17%). In contrast, deviations among the lighter elements from Ga to Te span nearly 1.4 dex, and they show distinct trends from Ga to Se, Nb through Cd, and In through Te. The r-process contribution to Ga, Ge, and As is small, and Se is the lightest element whose production is dominated by the r-process. The lanthanide fraction, log X La = -1.39 ± 0.09, is typical for r-process-enhanced stars and higher than that of the kilonova from the GW170817 neutron-star merger event. We advocate adopting this pattern as an alternative to the solar r-process-element residuals when confronting future theoretical models of heavy-element nucleosynthesis with observations.

79 ASTRONOMY AND ASTROPHYSICS↗

Critical Review of LPBF Metal Print Defects Detection: Roles of Selective Sensing Technology

The integrative potential of LPBF-printed parts for various innovative applications depends upon the robustness and infallibility of the part quality. Eliminating or sufficiently reducing factors contributing to the formation of defects is an integral step to achieving satisfiable part quality. Significant research efforts have been conducted to understand and quantify the triggers and origins of LPBF defects by investigating the material properties and process parameters for LPBF-printed geometries using various sensing technologies and techniques. Frequently, combinations of sensing techniques are applied to deepen the understanding of the investigated phenomena. The main objectives of this review are to cover the roles of selective sensing technologies by (1) providing a summary of LPBF metal print defects and their corresponding causes, (2) informing readers of the vast number and types of technologies and methodologies available to detect defects in LPBF-printed parts, and (3) equipping readers with publications geared towards defect detection using combinations of sensing technologies. Due to the large pool of developed sensing technology in the last few years for LPBF-printed parts that may be designed for targeting a specific defect in metal alloys, the article herein focuses on sensing technology that is common and applicable to most common defects and has been utilized in characterization for an extended period with proven efficiency and applicability to LPBF metal parts defect detection.

36 MATERIALS SCIENCE↗

Surface-Enhanced Raman Scattering Optophysiology Nanofibers for the Detection of Heavy Metals in Single Breast Cancer Cells

Mercury(II) ions (Hg2+) and silver ions (Ag+) are two of the most hazardous pollutants causing serious damage to human health. Here, we constructed surface enhanced Raman scattering (SERS)-active nanofibers covered with 4-mercaptopyridine (4-Mpy)-modified gold nanoparticles (AuNPs) to detect Hg2+ and Ag+. Experimental evidence suggests that the observed spectral changes originate from the combined effect of (i) the coordination between the nitrogen on 4-Mpy and the metal ions and (ii) the 4-Mpy molecular orientation (from flatter to more perpendicular with respect to the metal surface). The relative intensity of a pair of characteristic Raman peaks (at ~428 and ~708 cm-1) was used to quantify the metal ion concentration, greatly increasing the reproducibility of the measurement compared to signal-on or signal-off detection based on a single SERS peak. The detection limit of this method for Hg2+ is lower than that for the Ag+ (5 nM vs 100 nM), which can be explained by the stronger interaction energy between Hg2+ and N compared to Ag+ and N, as demonstrated by density functional theory (DFT) calculations. The Hg2+ and Ag+ ions can be masked by adding ethylenediaminetetraacetate (EDTA) and Cl-, respectively, to the Hg2+ and Ag+ samples. The good sensitivity, high reproducibility and excellent selectivity of these nanosensors were also demonstrated. Furthermore, detection of Hg2+ in living breast cancer cells at the subcellular level is possible thanks to the nanometric size of the herein described SERS nanosensors, allowing high spatial resolution and minimal cell damage.

Zhao, Xingjuan↗