Search NASA⌕ Search

SEARCH · Search NASA

Results for “metal impurities”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Electronic and optical properties of transition metal impurities in GaN and AlN

The optical properties of Cr(III) impurities are well studied and exploited in 𝛼−Al 2 ⁢O 3 , which enables ruby lasers. Photoluminescence spectra resembling the famous 1.78 eV emission of Cr in 𝛼−Al 2 ⁢O 3 have been observed in other wide-band-gap host materials, in particular AlN. However, it is unclear whether Cr would produce the same emission in the nitrides as in 𝛼−Al 2 ⁢O 3 , especially given the different local environment (tetrahedral vs octahedral coordination). We investigate the electronic and optical properties of transition metal substitutional impurities (Cr, Co, Ni, and Cu) in wurtzite GaN and AlN from first principles, utilizing hybrid density functional theory. We calculate the optical transition energies using a constrained occupation approach that accounts for the multideterminant nature of the excited states. Our results indicate that substitutional Cr(III) is not responsible for the emission near 1.78 eV observed in the nitrides. Among the examined impurities, only substitutional Co(II) produces emission near 1.78 eV. Based on the favorable properties of Co(II) (low formation energy, small Huang-Rhys factor, and an 𝑆 = 3/2 ground state) we propose it as a promising single-photon emitter or spin qubit. We additionally assign the PL peak observed near 1.05 eV in GaN and AlN to the 2 𝐸→ 4 𝐴 2 transition of the Ni(III) substitution.

36 MATERIALS SCIENCE↗

Diagnostics: Chapter 8 of the special issue: on the path to tokamak burning plasma operation

This chapter presents the activity conducted by the ITPA topical group (TG) on Diagnostics over about the last 15 years. Following a general introduction of the ITER Diagnostics led by their measurement roles, the document is organized in several subchapters detailing the design support, research and development activity conducted by each of the specialist working groups (WGs) of the TG. Please note that the magnetic diagnostics were supported at the TG without a specific WG. Their status is included in the general introduction. In the following some highlights of the subchapter’s contents are provided. Recent advances in ITER first wall (FW) diagnostics for the measurements of plasma-metallic wall interaction in support of the ITER research plan are reported. An InfraRed imaging Video Bolometer for ITER has been developed and tested on several tokamaks to measure the radiated power loss. A laser-induced breakdown spectroscopy (LIBS) technique which utilizes a pulsed laser beam to ablate locally by forming a crater, will measure local tritium inventory in the FW material. Real-time Residual Gas Analyzers will measure the neutral gas composition in a divertor port and an equatorial port during plasma operation. Due to the full metallic FW environment, the plasma-wall interaction in ITER will face several challenges such as the compromised radiated power and divertor heat flux measurements by reflection. Ray tracing and analysis codes have been developed to eliminate and correct the effects of reflection in the measurements. The characteristics of the reflecting surfaces depending on the roughness and angle of the incidence have been measured by dedicated experiments, and the results were applied to the reflection elimination. For the measurement of the metallic impurity radiation induced by eroded metallic atoms, a vacuum ultraviolet spectrometer has been developed and tested. An extensive thermonuclear diagnostic suite will be required to support the operation of ITER and the planned experimental program for future burning plasma experiments. Due to the harsh environmental conditions, the implementation of diagnostic systems in ITER is a major challenge. These conditions include high levels of neutron and gamma fluxes, neutron heating, particle bombardment. Therefore, the selection and design of diagnostic systems must take into account a number of phenomena previously unseen in diagnostic design. For this reason, the measurement of neutrons and confined or lost fast ions, with particular emphasis on alpha particles, is critical to ITER. The diagnostics associated with these measurements will be important for future plasma-burning experiments at ITER. The high neutron emission and very large plasma size in ITER make neutron diagnostics the main diagnostic method used to measure plasma parameters such as fusion power, fusion power density, ion temperature, energy of fast ions and their spatial distributions in the plasma core. Active spectroscopy techniques are methods where a neutral particle beam is injected into the plasma and information on plasma parameters is extracted from the measurement of line emission resulting from the beam-plasma interaction, either by plasma ions or by beam atoms. Spatial localization is achieved by crossing the beamline and multiple observation lines. The ITER plasma will be a high temperature, moderately dense, fully ionized collisional plasma. The plasma facing surfaces are principally metallic being fashioned from beryllium or tungsten but many other elements, arising from either structural or from operational needs, may enter this plasma. The energy range of the emitted photons range from meV (infra-red) to multi keV (x-rays) and originate from all areas of the plasma volume. The primary role of passive emission diagnostics is to identify what is in the plasma from spectral signatures. Extracting quantitative information from these measurements such as impurity content, ion temperature, rotation, degree of detachment and radiated power depends on calibrated instruments, a physics model of the atomic and molecular processes and plasma transport and an analysis workflow that takes into account environmental effects such as reflections. The particular needs for ITER have prompted a multi-machine, many-year effort to address all these aspects and this chapter reviews the work on diagnostic design, experiments and new analysis techniques. An overview of the laser diagnostics to be implemented on ITER is also provided in this paper. This includes descriptions of the Thomson scattering in the core, edge and divertor regions, polarimetry and interferometry diagnostics used for measuring plasma density and also measurements of helium density in the divertor using Laser Induced Flourescence. Techniques which can allow improvements on current measurements are also addressed in particular expanding poloidal polarimetry measurements to measure field fluctuations and proposed use of dispersion interferometery which has a number of advantages over existing methods. This paper identifies particular areas where further research and testing on existing tokamaks is useful even at this advanced stage to inform the design of diagnostics for ITER. Outstanding areas of concern for the implementation of laser diagnostics, in particular with a view to reliable operation are identified. An overview of the latest developments of microwave diagnostic systems and techniques is given. The primary focus is the contributions for ITER—the next step burning plasma experiment—which is supplemented by describing recent progress of techniques applicable for fusion experiments beyond ITER. The contributions are intentionally kept concise, and are being supplemented by a rich list of references for further studies. Radiation induced effects are receiving continuous and well-deserved attention of the ITER diagnostic community and they are in many cases one of the primary design drivers of the ITER diagnostic systems. The paper summarizes recent progress in this area focusing primarily on the ITER diagnostics but in some cases provides also outlook for the possible solutions for even more demanding radiation environment of fusion reactors beyond ITER. Despite advancements in the area of modeling and simulation of various radiation induced effects, experimental testing in a nuclear environment as close as possible to the target one is still seen as unavoidable for proper qualification of particular diagnostic functional elements. Recent advancement within three diagnostic areas: optical diagnostics, magnetics and bolometers is covered. Encouraging results on qualification of silica glass vacuum window assemblies are presented. In the area of magnetic sensors, progress of irradiation tests performed on ITER in-vessel LTCC inductive sensors is presented with outlook for novel technological approaches to inductive sensors utilizing thick printing and photolithography technologies being highlighted. Summary of advancements in the area of steady state magnetic field sensors based on Hall effect is given. New results of neutron irradiation test of the ITER borosilicate glass inserts for vacuum electrical feedthroughs are summarized finding negligible swelling at target level of neutron fluence. Off-line irradiation tests of fiber optic current sensors for plasma current measurement demonstrated that both for gamma doses up to 5 MGy and a total neutron fluence up to 10 15 cm −2 , radiation induced changes are still compatible with required measurement accuracy on ITER. The ITER bolometers are given as an example how considering radiation effects may influence the diagnostic design. Finally, outlook for future main R&D directions is outlined. All optical and laser-based diagnostics in ITER will be using mirrors to guide plasma radiation toward detectors, cameras and sensors. In the hostile plasma, radiation and particle environment the optical characteristics of diagnostic mirrors will degrade directly affecting the entire performance of involved diagnostic systems. An assessment of factors affecting mirror performance is provided. Among the prime adverse factors are deposition of plasma impurities, sputtering of mirror surface and steam ingress in the vicinity of mirrors. Within the International Tokamak Physics Activity with active support by ITER central team and domestic agencies, the structured research and development (R&D) program on mitigation of risks for diagnostic mirrors is underway. Within this program the mirror material development, the passive mitigation of mirror degradation by using diagnostic ducts and shutters along with an active mirror recovery program comprising the in-situ mirror cleaning and calibration is underway. Recent developments in diagnostic mirror R&D are described in this Chapter along with an example of their implementation of R&D solutions in ITER Infrared Thermography diagnostic. An assessment of still open engineering and physics questions, considerations on mirror risks during an early phase of ITER operation are given along with an overview of diagnostic mirror evolution in the late ITER operation stage toward the demonstration fusion power plant. Several crucial areas of diagnostic R&D outlined in ITER Research Plan are addressed. The basic control groups in a fusion reactor can be broken-down in five categories: (1) plasma position, magnetic configuration, and plasma current control, (2) profile control and confinement optimization, (3) MHD control and suppression, (4) edge dissipation control, radiation and plasma exhaust control and (5) break-down optimization. These categories are coupled via the physics (a control action in one domain will affect the other domains) and via shared actuators (e.g. ECRH for impurity accumulation avoidance, current density distribution control and MHD suppression). Consequently, a supervisory control system should determine the priority of the various control tasks, their couplings, and the interfaces with the safety and interlock system. For the systematic development of the various controllers taking the complexity of the plasma and the control system into account, a model-based approach is required. A short historical overview is given of the developments in systems and control theory and control engineering with special emphasis on those developments that are most relevant for Nuclear Fusion research and operation. An overview is given of the state of the field of fusion plasma control for the control categories. It will be shown how synthetic diagnostics are being developed in ITER and how they are used in diagnostic design and design validation and how they can be in model-based controller synthesis using relatively simple models. In modern control methods, multiple diagnostics are used to constrain relatively simple models. The constrained models provide an estimate for the state. This opens the route to state controllers, such as model predictive control. A major challenge in nuclear fusion research is the coherent combination of data from heterogeneous diagnostics and modeling codes for machine control and safety as well as physics studies. Measured data from different diagnostics often provide information about the same subset of physical parameters. Additionally, information provided by some diagnostics might be needed for the analysis of other diagnostics. A joint analysis of complementary and redundant data allows, e.g. to improve the reliability of parameter estimation, to increase the spatial and temporal resolution of profiles, to obtain synergistic effects, to consider diagnostics interdependencies and to find and resolve data inconsistencies. Physics-based modeling and parameter relationships provide additional information improving the treatment of ill-posed inversion problems. A coherent combination of all kind of available information within a probabilistic framework allows for improved data analysis results. The concept of integrated data analysis (IDA) in the framework of Bayesian probability theory is outlined and contrasted with conventional data analysis. Components of the probabilistic approach are summarized and specific ingredients beneficial for data analysis at fusion devices are discussed.

ITER↗

Characterization of chromium impurities in β -Ga2O3

Chromium is a common transition-metal impurity that is easily incorporated during crystal growth. It is perhaps best known for giving rise to the 694.3 nm (1.786 eV) emission in Cr-doped Al2O3, exploited in ruby lasers. Chromium has also been found in monoclinic gallium oxide, a wide-bandgap semiconductor being pursued for power electronics. In this work, we thoroughly characterize the behavior of Cr in Ga2O3 through theoretical and experimental techniques. β-Ga2O3 samples are grown with the floating zone method and show evidence of a sharp photoluminescence signal, reminiscent of ruby. We calculate the energetics of formation of Cr from first principles, demonstrating that Cr preferentially incorporates as a neutral impurity on the octahedral site. Cr possesses a quartet ground-state spin and has an internal transition with a zero-phonon line near 1.8 eV. By comparing the calculated and experimentally measured luminescence lineshape function, we elucidate the role of coupling to phonons and uncover features beyond the Franck–Condon approximation. The combination of strong emission with a small Huang–Rhys factor of 0.05 and a technologically relevant host material renders Cr in Ga2O3 attractive as a quantum defect.

Turiansky, Mark E. (ORCID:0000000291543582)↗

The Effects of Iron and Manganese Doping on the Carbonation of Brucite [Mg(OH) 2 ]

Brucite [Mg(OH) 2 ] is a promising sorbent for carbon dioxide removal (CDR) due to its availability and low calcination temperatures. However, natural and synthetic brucites tend to contain metal impurities, such as iron or manganese, and how these impurities affect the interfacial chemical reactivity is uncertain. Here, in this study, the impact of low concentrations of iron and manganese impurities on the carbonation efficiency of Mg(OH) 2 was examined. Mg(OH) 2 with small amounts (1–5 mol %) of Fe and Mn was synthesized. The increasing substitution of Fe into Mg(OH) 2 was accompanied by the oxidation of Fe. The phase transformation sequence during the carbonation was found to be brucite [Mg(OH) 2 ] → amorphous magnesium carbonate (MgCO 3 ·nH 2 O) → nesquehonite (MgCO 3 ·3H 2 O), regardless of impurity concentration. Both the Fe- and Mn-doped Mg(OH) 2 samples were more reactive than endmember Mg(OH) 2 , possibly due to their higher surface areas and lower stabilities. During carbonation, 3 mol % Fe- and Mn-doped Mg(OH) 2 showed the highest reactivity. The variance in reactivity for Mn-doped Mg(OH) 2 was less than that of Fe-doped Mg(OH) 2 . These results suggest that natural or industrial waste Mg(OH) 2 with less than 5 mol % Fe and Mn impurities may be targeted as more effective CDR sorbents than endmember Mg(OH) 2 .

Carbon dioxide removal↗

Mg vacancy and impurity-limited MgO single crystal thermal conductivity

Magnesium oxide (MgO) exhibits one of the highest thermal conductivities among oxides and is widely used as a dielectric material and substrate in semiconductor devices, in refractory applications, and as a promising filler in thermal interface materials for electronics. Its high thermal conductivity may be sensitive to impurity and defects, yet this influence is still uncertain. Here, in this study, the impact of the common impurities, i.e., Al, Ca, Ti, V, Fe, Si, B, Nb, Zr, Na, and K, as well as Mg and O vacancies on phonon scattering and thermal conductivity of MgO is studied using a fully first-principles T-matrix framework. It is found that B, Nb, and Zr impurities, along with Mg vacancies, lead to exceptionally strong reductions in thermal conductivity. By contrast, O vacancies and other impurities have modest to minimal impacts. Leveraging the T-matrix results, we reassess the perturbative, mass-only formalism whose use is pervasive in the literature and show that neglecting bond disorder does not necessarily lead to underestimation: for all transition-metal impurities studied, bond perturbations partially cancel mass disorder, causing the traditional perturbative model to overestimate scattering. We propose a simple modified perturbative expression that incorporates both mass and bond disorder and closely reproduces the T-matrix trends. Our predicted low-temperature trends by including phonon-impurity and phonon-boundary scattering match reasonably well with experiments. This work provides an in-depth study of impurity- and vacancy-limited thermal conductivity of MgO and suggests that reported “high-purity” MgO values have likely not yet reached the intrinsic upper limit, which may be substantially higher.

36 - MATERIALS SCIENCE↗

Improved 140 Nd Production for the 140 Nd/ 140 Pr In Vivo Generator through Target Recycling and Radiochemical Optimization

Theranostic strategies that utilize f-block therapeutic radionuclides, including 161 Tb, 177 Lu, 225 Ac, and 227 Th, suffer from a shortage of positron emission tomography (PET) imaging counterparts in the same chemical space and often rely on 68 Ga as a surrogate. The 140 Nd/ 140 Pr in vivo PET generator, which belongs to the f-block, may address this issue and can be produced via the 141 Pr(p,2n) 140 Nd production route by using medium-energy cyclotrons. However, impurities in the target material, including stable Nd, and the inherent difficulty of adjacent lanthanide separations limit the achievable radionuclidic and chemical purity of 140 Nd. In this work, we address these challenges through the purification and recycling of praseodymium target material and optimization of Nd/Pr separation. The resulting purified 140Nd was evaluated using DOTA and Macropa chelators via radiolabeling and in vitro stability studies. A target material purification and recycling method was developed for the monoisotopic 141 Pr starting material to remove stable Nd impurities, yielding 90.3 ± 4.7% (n = 3) recovery. The purified 141 Pr was isolated as Pr 6 O 11 and irradiated with 24 MeV protons (20.07 MeV at the target surface) at 20 μA for 4 h, which produced 1417.0 ± 83.4 MBq (38.3 ± 2.2 mCi) of 140 Nd at the end of bombardment (EOB). The produced 140 Nd was purified through an optimized DGA normal method to recover 71.6 ± 6.3% pure 140 Nd. The amount of stable Nd reduced progressively in each target purification cycle from >340 ppm without purification to <250 ppb after three cycles, while other measured metallic impurities were below 30 ppb. This improvement in target purity was reflected in the direct increase of apparent molar activity (AMA), when purified 140 Nd was evaluated with DOTA and Macropa chelators. AMA of [ 140 Nd]Nd-DOTA and [ 140 Nd]Nd-Macropa increased from 70.3 MBq/μmol (1.9 mCi/μmol) and 74 MBq/μmol (2.0 mCi/μmol) to 8025.3 MBq/μmol (216.9 mCi/μmol) and 8473.0 MBq/μmol (229.0 mCi/μmol), respectively, after the third target purification cycle. Further evaluation of chelator-labeled 140 Nd showed that [ 140 Nd]Nd-DOTA was stable in phosphate-buffered saline (PBS), saline, human serum, and mouse serum, whereas [140Nd]Nd-Macropa was stable in all except human serum. This work established a practical methodological advance for the production of 140 Nd/ 140 Pr in vivo PET generators, combining optimized target recycling and radiochemical separation to enable scaled-up and high-molar activity 140 Nd suitable for preclinical imaging. These advances support broader development of 140 Nd/ 140 Pr as a robust PET analogue, especially for f-block therapeutics.

Irradiation↗

The Defects Genome of Janus Transition Metal Dichalcogenides

2D Janus Transition Metal Dichalcogenides (TMDs) have attracted much interest due to their exciting quantum properties arising from their unique two-faced structure, broken-mirror symmetry, and consequent colossal polarization field within the monolayer. While efforts are made to achieve high-quality Janus monolayers, the existing methods rely on highly energetic processes that introduce unwanted grain-boundary and point defects with still unexplored effects on the material's structural and excitonic properties Through high-resolution scanning transmission electron microscopy (HRSTEM), density functional theory (DFT), and optical spectroscopy measurements; this work introduces the most encountered and energetically stable point defects. It establishes their impact on the material's optical properties. HRSTEM studies show that the most energetically stable point defects are single (V S and V Se ) and double chalcogen vacancy (V S −V Se ), interstitial defects (Mi), and metal impurities (MW) and establish their structural characteristics. DFT further establishes their formation energies and related localized bands within the forbidden band. Cryogenic excitonic studies on h-BN-encapsulated Janus monolayers offer a clear correlation between these structural defects and observed emission features, which closely align with the results of the theory. Finally, the overall results introduce the defect genome of Janus TMDs as an essential guideline for assessing their structural quality and device properties.

2D materials↗

Effect of Iron Contamination and Polysilicon Gettering on the Performance of Polysilicon‐Based Passivating Contact Solar Cells

Over the past decade, silicon solar cells with carrier-selective passivating contacts based on polysilicon capping an ultra-thin silicon oxide (commonly known as TOPCon or POLO) have demonstrated promising efficiency potentials and are regarded as an evolutionary upgrade to the PERC (passivated emitter and rear contact) cells in manufacturing. The polysilicon-based passivating contacts also exhibit excellent gettering effects that relax the wafer and cleanroom requirements to some extent. Here, in this work, we experimentally explore the impact of bulk iron contamination and polysilicon gettering on the passivation quality of the polysilicon/oxide structure and the resulting solar cells performance. Results show that both n- and p-type polysilicon/oxide passivating contacts are not affected by iron gettering, demonstrating robust and stable passivation quality. However, for a very high bulk iron contamination (1 × 10 13 cm −3 ), the accumulated iron in the p-type lightly boron-doped emitter in crystalline silicon would degrade the emitter saturation current density. This can cause a reduction in both open-circuit voltage and short-circuit current. Meanwhile, this very high iron content (1 × 10 13 cm −3 ) can further degrade the fill factor and temperature coefficient of the cells. On the other hand, for an initial iron content of 2 × 10 12 cm −3 , which should be well above the iron level in the current industrial Czochralski silicon wafers, the resulting cells demonstrate similar performance as the control group with no intentional iron contamination. This work brings attention to both the benefits of polysilicon gettering effects as well as the potential degradation due to the accumulation of metal impurities in the p-type emitter region.

14 SOLAR ENERGY↗

Elucidating the Structural and Electronic Effects of Ni and Mn Cationic Incorporation on CoOOH for Efficient Benzyl Alcohol Electrooxidation

Transition-metal oxyhydroxides such as CoOOH are promising low-cost electrocatalysts for the selective electrooxidation of organic molecules, yet the influence of ubiquitous transition-metal impurities on their performance and durability remains poorly understood. Here, we experimentally probed the individual and synergistic electrochemical and structural effects of Ni and Mn incorporations into model CoOOH electrocatalysts toward an efficient benzyl alcohol oxidation reaction (BAOR). Comprehensive electrochemical, microscopic, and spectroscopic analyses reveal that Ni incorporation enhances charge-transfer kinetics and overall activity through the formation of catalytically active Ni 3+ sites, whereas Mn exhibited a more complex but interesting role. At the early stages of operation, Mn 4+ acts as a stabilizing surface layer that mitigates catalyst degradation but partially blocks Co sites before they undergo gradual leaching. The concurrent incorporation of both Ni and Mn yields a trimetallic 2NMC@NF electrocatalyst that integrates the activity benefits of Ni with the stability conferred by Mn, achieving 92.9% benzyl alcohol conversion and 91.4% Faradaic efficiency after 24 h at 1.5 V vs RHE. These findings elucidate how trace Ni and Mn impurities, often introduced from electrolytes or external sources, can modulate the lattice and electronic structure of CoOOH, offering a design strategy for enhancing both activity and long-term stability in electrocatalytic organic oxidation.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Electrochemical carbon deposition from CO 2 in molten carbonates: substrate-dependent growth

Electrochemical carbon deposition from molten carbonate salts using inert electrodes and no additional catalyst is systematically examined. At sufficiently cathodic potentials, carbon formation occurs within 30 min and transitions from substrate-dependent nucleation to carbon-on-carbon growth. Although deposits formed on either mild-steel or graphite cathodes exhibit comparable thicknesses and salt contents, their macrostructures differ, reflecting differences in early-stage growth rates and surface chemistry. Characterization by ICP-OES, Raman spectroscopy, SEM/EDS, synchrotron powder X-ray diffraction, and C K-edge X-ray absorption near edge structure reveals that the as-deposited carbon is predominantly disordered sp 2 -bonded material. However, post-treatment reveals latent turbostratic ordering in select samples, indicating that short-range order is established during deposition but is obscured by an entrained electrolyte and kinetically formed amorphous phases. No anode-derived contamination is detected, and carbon grown on graphite cathodes shows minimal metallic impurities. These results clarify the role of cathode surface chemistry and provide pathways for controlling electrode-derived impurity incorporation and carbon structure in catalyst-free molten carbonate systems.

36 MATERIALS SCIENCE↗

Investigation of magnetic and electrical transport properties of YMB 4 (M = Cr, Fe, and Co) compounds

We have studied the structural, magnetic, and electrical transport properties of the YMB 4 series of compounds (M= Cr, Fe, and Co). These materials exhibit high stability and possess notable refractory and thermoelectric properties. Furthermore, recent theoretical predictions suggest that some of these compounds may display quantum magnetism and dimer formation among the magnetic ions. We have synthesized almost single phase YMB 4 compounds in the orthorhombic crystal structure (space group Pbam) using arc-melting and annealing. The Rietveld analysis of the room-temperature X-ray diffraction patterns reveals a clear change in the lattice parameter c, which correlates with the atomic radii of Cr, Fe, and Co. The temperature variation of resistivity measured between 2 K and 300 K reveals a metallic electron transport in all three YMB 4 compounds. However, no abrupt change in resistivity due to structural or magnetic phase transitions is observed. Additionally, a weak positive magnetoresistance of 1%–2% has been measured at 2.5 K, the contribution from the metallic impurity cannot be ruled out. The carrier concentration, on the order of 10 21 cm −3 , has been determined using conventional Hall measurements. The thermomagnetic curves recorded between 2 K and 350 K reveal the non-magnetic behavior of all these compounds. However, a small magnetic moment from paramagnetic/ferromagnetic impurity phases is detected at low temperatures. Above room temperature, no magnetic transition associated with the breaking of a dimer is observed.

borides↗

Laser-spectroscopy testbed for impurity monitoring in liquid metal-cooled fast reactors

A significant challenge in sodium-cooled fast reactors is controlling impurities, in particular oxygen impurities, within the sodium coolant, as they can accelerate corrosion and indicate leaks. Optical methods offer the potential to rapidly detect small concentrations of both gaseous and metal impurities that accelerate corrosion, plug coolant channels, and lead to increased activation of isotopes in the coolant. We present the design and performance of an apparatus designed to enable the application of multiple optical analytical techniques, such as laser-induced breakdown spectroscopy, to detect elemental impurities in the sodium melt with high sensitivity. Here, we experimentally demonstrate the detection of characteristic sodium and oxygen spectral lines in liquid sodium, which sets the stage for the optimization of its analytical sensitivity. A robust sensor of this type integrated with the sodium cooling loop has the potential to significantly improve the safety and operational efficiency of generation IV nuclear reactors.

47 OTHER INSTRUMENTATION↗

Strongly Correlated States of Transition Metal Spin Defects: The Case of an Iron Impurity in Aluminum Nitride

We investigate the electronic properties of an exemplar transition metal impurity in an insulator, with the goal of accurately describing strongly correlated defect states. Here, we consider iron in aluminum nitride, a material of interest for hybrid quantum technologies, and we carry out calculations with quantum embedding methods, density matrix embedding theory (DMET) and quantum defect embedding theory (QDET), and with spin-flip time-dependent density functional theory (TDDFT). We show that both DMET and QDET accurately describe the ground state and low-lying excited states of the defect and that TDDFT yields photoluminescence spectra in agreement with experiments. In addition, we provide a detailed discussion of the convergence of our results as a function of the active space used in the embedding methods, thus defining a protocol to obtain converged data directly comparable with experiments.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Demonstration of Electroreduction Technology to Convert GNF Uranium Oxide Powder to Metal

Global Nuclear Fuel – Americas LLC (GNF) has partnered with Argonne National Laboratory to demonstrate electroreduction of uranium oxides produced by deconversion of UF 6 to uranium metal through the Gateway for Accelerated Innovation in Nuclear (GAIN) program under the U.S. Department of Energy to accelerate the domestic production of metallic advanced reactor fuels. Electroreduction of uranium oxide was first demonstrated and patented by Argonne in the early 2000s as a technology to convert used oxide nuclear fuel from light water reactors to metal for further fuel reprocessing. More recently, electroreduction has been proposed as a front-end technology for metallization of uranium oxides produced by deconversion of UF 6 and for scrap recovery of oxide materials. During the electroreduction process, UO 2 powder is contained in a stainless-steel mesh basket with a cathode lead located in the center of the UO 2 bed. The basket is immersed in lithium chloride molten salt electrolyte containing 1 wt% lithium oxide along with a platinum anode and a nickel/nickel oxide (Ni/NiO) reference electrode. Current is applied to the cell between the cathode and anode to reduce the UO 2 to metallic uranium via a solid-state reduction reaction. Oxide ions released from the UO 2 during reduction are transported through the salt to the anode where oxygen gas is evolved. Once reduction is complete, the basket containing the metallicized uranium is removed from the salt and can be processed to remove the salt and consolidate the uranium into an ingot for use in metallic fuel fabrication. This project was performed to provide evidence of the electroreduction technology readiness level for metallization of UO 2 powder, identify and retire technical risks for industrialization of electroreduction, and accelerate the path to commercialization for metallic fast reactor fuel production. To that end, five electroreduction tests were performed with UO 2 provided by GNF and the resulting product was analyzed for the extent of conversion to metal and for impurity contents of the metal product to verify that electroreduction does not introduce impurities that would prevent use of the product in metallic fuel fabrication.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Predicting Li-ion Battery Performance for Impurity-doped NMC Cathodes Using Deep Learning

With the electric vehicle (EV) market expansion and the energy sector's shift towards electrification, the demand for battery metals, including lithium (Li), cobalt (Co), and nickel (Ni), is set to surpass supply. A critical knowledge gap exists in the purity standards for battery precursors and the impact of impurities on battery performance. Addressing this, our study employs a Deep Machine Learning (DL) based multi-objective optimization approach to interpret the relationship between metal impurities in domestic battery resources and their effects on battery performance. We analyze experimental data from Li-ion batteries with NMC (Nickel-Manganese-Cobalt oxide) cathodes over 1000 cycles, representing approximately ~6-8 months of operation, to establish a baseline of performance without impurities. Leveraging this data, we develop a Physics-Informed Deep Learning (PIDL) framework to extend our findings to cases that include metal impurities (e.g., Fe, Cu, Al) ranging from (0.001 - 0.01) %, respectively. By incorporating physics-based features, our PIDL model can accurately estimate the performance of NMC cathodes doped with various metal impurities to provide rapid design decisions. This research paves the way for informed decisions in Li-ion battery material design and optimization, ensuring the sustainable growth of the EV market and the broader energy sector.

25 ENERGY STORAGE↗

Catalytic Ammonia Synthesis over Pure, Defective, and Metal-Doped Rutile TiO 2 : A Periodic DFT Study

In this work, we aim to describe the energetics associated with the formation of ammonia from N 2 interacting with doped hydroxylated rutile TiO 2 (110) surfaces with the vacant O 2c site, following the reaction N 2 + 3H 2 O → 2NH 3 + 3/2O 2 . The water molecules interact with the surface, creating exposed Ti−OH groups that can transfer hydrogen to the adsorbed N 2 molecule. Two metal dopants are evaluated: Mo and Ta. For both metals, calculations show a dramatic decrease in the energy of most intermediates during the entire mechanism, leading to more favorable reaction mechanisms. Nonetheless, it is worth noting that when the Ti 6c site of the vacant site is doped with either Mo or Ta, there is a stronger effect on the energetics than doping on the exposed Ti 5c sites. The effect of increasing the concentration of metal dopants on the vacant site was also investigated. In this case, calculations indicate that a higher percentage of the dopant on the surface results in a more substantial decrease in the energy of most intermediates, suggesting that increasing the dopant content could be beneficial for the catalytic process.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Iron Impurity Impairs the CO 2 Capture Performance of MgO: Insights from Microscopy and Machine Learning Molecular Dynamics

Magnesium oxide (MgO) is a promising sorbent for direct air capture (DAC) of carbon dioxide. Iron (Fe) is a common impurity in naturally occurring MgO and minerals used to produce MgO, yet a molecular-scale understanding of Fe-doping effects on carbonation is lacking. Here, in this study, we observed reduced carbonation performance in Fe-doped MgO experimentally. The energetics of adsorbing a (bi)carbonate ion on pristine and Fe-doped MgO(001) surfaces were further investigated using ab initio and machine learning potential molecular dynamics coupled with metadynamics simulations. Both pristine and Fe-doped surfaces exhibited a basic (OH – ) hydration layer, where the (bi)carbonate ion adsorption is thermodynamically favorable. However, the dissolution of surface Fe had smaller energy barriers and was more favorable than Mg. Leached Fe likely neutralized the near-surface basicity, yielding reduced reactivity on Fe-doped MgO. Our observations offer critical insights for material selection and emphasize the importance of evaluating the geologic origin of earth materials used for DAC.

36 MATERIALS SCIENCE↗