Search NASA⌕ Search

SEARCH · Search NASA

Results for “metallic conductivity”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Mechanical property determination of high conductivity metals and alloys

Pertinent mechanical properties of three high conductivity metals and alloys; namely, vacuum hot pressed grade S-200E beryllium, OFHC copper and beryllium-copper alloy no. 10 were determined. These materials were selected based on their possible use in rocket thrust chamber and nozzle hardware. They were procured in a form and condition similar to that which might be ordered for actual hardware fabrication. The mechanical properties measured include (1) tension and compression stress strain curves at constant strain rate (2) tensile and compressive creep, (3) tensile and compressive stress-relaxation behavior and (4) elastic properties. Tests were conducted over the temperature range of from 75 F to 1600 F. The resulting data is presented in both graphical and tabular form.

Harrod, D. L.↗

Method for attaching a fused-quartz mirror to a conductive metal substrate

A fused-quartz mirror is attached to a conductive metal substrate by the following steps: tinning one surface of a fused-quartz mirror with a solder of substantially pure indium; tinning a metallic substrate with an indium eutectic alloy consisting essentially of indium bismuth, lead and tin having a melting point substantially below that of indium; heating the eutectic alloy to a temperature substantially above its melting point, but below that of the solder; floating the mirror into place, and subsequently cooling the alloy to a temperature substantially below its melting point.

Sonnenschein, G.↗

Metallic conductivity and air stability in copper chloride intercalated carbon fibers

Carbon-copper chloride intercalation compounds have been obtained by using variously graphitized carbon fibers as host materials. The resultant conductors are air stable, thermally stable to 450 K, have electrical resistivities as low as 12.9 microohm cm at room temperature, and have metallic conductivity temperature dependencies. These intercalated fibers have tensile strengths of 160000 psi, and Young's moduli of 25 x 10 to the 6th psi. For aerospace use, 1/(resistivity x density) is a figure of merit. On this basis, a reduction in resistivity by a factor of two will make this conductor competitive with copper.

Oshima, H.↗

Thermally-Conductive Metallic Coatings and Applications for Heat Removal on In-Space Cryogenic Vehicles

For large in-space cryogenic upper stages, substantial axial heat removal from a forward skirt by vapor-based heat interception may not be achieved by simple attachment methods unless sufficient thermal conductance from the skirt to the cooling fluid can be achieved. Preferable methods would allow for the addition of the cooling system to existing structure with minimal impact on the structure. Otherwise, significant modification to the basic structural design andor novel and complex attachment mechanisms with high effective thermal conductance are likely to be required. The approach being pursued by evolvable Cryogenics (eCryo) is to increase the thermal performance of a relatively simple attachment system by applying metallic or other thermally conductive material coatings to the mating surface area of the fluid channel where it is attached the skirt wall. The expectation of candidate materials is that the dramatic increase in conductivity of pure metals at temperatures close to liquid hydrogen vapor temperature will compensate for the reduced actual contact area typical of mechanical joints. Basic contact conductance data at low temperatures for candidate interface materials is required to enable the test approach. A test rig was designed at NASA Glenn Research Center to provide thermal contact resistance testing between small sample coupons coated with conductive material via electron beam evaporation, a low-temperature option that will not affect physical properties of base materials. Average coating thicknesses were 10 k. The test fixture was designed to mount directly to a cryocooler cold head within a vacuum test chamber. The purpose of this test was to determine qualitative contact conductance between various test samples. Results from this effort will be implemented in a sub-scale vapor-based heat interception test, where the applicability for increased heat removal on large structural skirts will be considered.

small scale testing↗

Low conducting metal screen support flange

In a very high or very low temperature duct system in which duct insulation is terminated at selected locations so as to be not coextensive with the duct, an annular metal perforated or mesh screen support flange is used, as a low conductor of heat or cold, between the duct and an outer insulation cover to retain the end of the insulation and to support its usually very thin cover. The screen may be Z-shaped in cross section having a small diameter annular portion to surround and be secured to the duct adjacent the end of the insulation. A generally radially extending portion of the screen extends outwardly from the small diameter portion and adjacent the end of the insulation. The periphery of the radially extending portion is in alignment with the outer peripheral surface of the insulation and the outer peripheral surface of the insulation cover. A large diameter annular portion of the screen extends longitudinally from the periphery in the direction opposite the small diameter portion, and is adapted to surround the insulation and its cover and be secured thereto. The screen may also be U or channel-shaped with one longitudinally directed leg secured to the insulation cover and the other leg secured to the duct under the insulation.

Lestak, Robert G.↗

Improved heat shield/radiator

Thermally conductive metal shield is put in direct thermal contact with the mounting plate for the radiation detectors. External surfaces of the shield are insulated by an insulation blanket. The internal faces are covered with a thin layer of quartz with a metallic thermally conductive coating on the hidden faces.

Smith, J. W.↗

Thermal contact conductance between metals in a vacuum environment

Basic heat transfer data for structural materials used in the Saturn 1B/V 1U component case structural design were obtained. The main emphasis is on thermal contact conductance between dissimilar metallic surfaces, since thermal conductivity values within solids have been sufficiently established previously. The test program outline and test results are described. The following materials were tested: aluminum 6061-T6 (12 samples), aluminum 356 (as cast), almag 35 (as cast), magnesium AZ91C-T4 (4 samples), and mag lithium LA-141 (2 samples).

Source record↗

The structure and the magnetic field of Uranus

The two-layer model of Uranus is recalculated using a rotation period of 24 rather than 10.8 hours and also the melting temperatures of H2O and of the constituents of the core are evaluated. It appears that the core is solid and the H2O-containing mantle is liquid. The conductivities of H2O, 'metallic' H2 and metallic H are roughly in the ratio of 1:100:10000 so that the convective velocities required for the operation of a dynamo would have to be about 10, 0.1 and 0.001 cm/sec, respectively. The very low thermal flux from Uranus suggests that, unless a precessional dynamo is invoked, metallically conducting H2 or metallic hydrogen has to be present in the mantle.

Torbett, M.↗

ADR salt pill design and crystal growth process for hydrated magnetic salts

A process is provided for producing a salt pill for use in very low temperature adiabatic demagnetization refrigerators (ADRs). The method can include providing a thermal bus in a housing. The thermal bus can include an array of thermally conductive metal conductors. A hydrated salt can be grown on the array of thermally conductive metal conductors. Thermal conductance can be provided to the hydrated salt.

Shirron, Peter J.↗

Thermal Conductances Of Metal Contacts

Report presents results of measurements of thermal conductances of aluminum and stainless-steel contacts at temperatures from 1.6 to 6.0 K. Measurement apparatus includes gearmotor assembly connected to rocker arm by music wire to load sample pair with forces up to 670 N. Heater placed above upper sample. Germanium resistance thermometers in upper and lower samples measured temperature difference across interface over range of heater powers from 0.1 to 10.0 mW. The thermal conductance calculated from temperature difference. Measurements provide data for prediction of thermal conductances of bolted joints in cryogenic infrared instruments.

Salerno, L. J.↗

Temperature dependence of electrical conductivity and lunar temperatures

Metallic conduction mechanicsms are probably not important in lunar materials because of the small amounts of free metal and metallic oxides present. This is confirmed by the extremely low conductivities measured to date and the fact that the conductivity increases with temperature. The major conduction mechanicsm appears to be ionic. This conduction mechanism is very strongly controlled by temperature, by deviations from stoichiometry, by electric field strengths, and by oxygen fugacity.

Olhoeft, G. R.↗

Flexible thin metal film thermal sensing system

A flexible thin metal film thermal sensing system is provided. A self-metallized polymeric film has a polymeric film region and a metal surface disposed thereon. A layer of electrically-conductive metal is deposited directly onto the self-metallized polymeric film's metal surface. Coupled to at least one of the metal surface and the layer of electrically-conductive metal is a device/system for measuring an electrical characteristic associated therewith as an indication of temperature.

Thomsen, Donald L.↗

Thermally Conductive Metal-Tube/Carbon-Composite Joints

An improved method of fabricating joints between metal and carbon-fiber-based composite materials in lightweight radiators and heat sinks has been devised. Carbon-fiber-based composite materials have been used in such heat-transfer devices because they offer a combination of high thermal conductivity and low mass density. Metal tubes are typically used to carry heat-transfer fluids to and from such heat-transfer devices. The present fabrication method helps to ensure that the joints between the metal tubes and the composite-material parts in such heat-transfer devices have both (1) the relatively high thermal conductances needed for efficient transfer of heat and (2) the flexibility needed to accommodate differences among thermal expansions of dissimilar materials in operation over wide temperature ranges. Techniques used previously to join metal tubes with carbon-fiber-based composite parts have included press fitting and bonding with epoxy. Both of these prior techniques have been found to yield joints characterized by relatively high thermal resistances. The present method involves the use of a solder (63 percent Sn, 37 percent Pb) to form a highly thermally conductive joint between a metal tube and a carbon-fiber-based composite structure. Ordinarily, the large differences among the coefficients of thermal expansion of the metal tube, solder, and carbon-fiber-based composite would cause the solder to pull away from the composite upon post-fabrication cooldown from the molten state. In the present method, the structure of the solder is modified (see figure) to enable it to deform readily to accommodate the differential thermal expansion.

Copeland, Robert J.↗

Thermal conductivity of metals

The objective is to familiarize students with steady and unsteady heat transfer by conduction and with the effect of thermal conductivity upon temperature distribution through a homogeneous substance. The elementary heat conduction experiment presented is designed for associate degree technology students in a simple manner to enhance their intuition and to clarify many confusing concepts such as temperature, thermal energy, thermal conductivity, heat, transient and steady flows. The equipment set is safe, small, portable (10 kg) and relatively cheap (about $1200): the electric hot plate 2 kg (4.4 lb) for $175: the 24 channel selector and Thermocouple Digital Readout (Trendicator) 4.5 kg (10 lb) for about $1000; the three metal specimens (each of 2.5 cm diameter and 11 cm length), base plate and the bucket all about 3 kg (7 lb) for about $25. The experiment may take from 60 to 70 minutes. Although the hot plate surface temperature could be set from 90 to 370 C (maximum of 750 watts) it is a good practice to work with temperatures of 180 to 200 C (about 400 watts). They may experiment in squads of 2, 3 or even 4, or the instructor may demonstrate it for the whole class.

Kazem, Sayyed M.↗