Search NASA⌕ Search

SEARCH · Search NASA

Results for “methyl iodide adsorption”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Studies on the Mechanisms of Methyl Iodide Adsorption and Iodine Retention on Silver-Mordenite

Silver-containing mordenite (MOR) is a longstanding benchmark for radioiodine capture, reacting with molecular iodine (I 2 ) to form AgI. However the mechanisms for organoiodine capture are not well understood. Here we investigate the capture of methyl iodide from complex mixed gas streams by combining chemical analysis of the effluent gas stream with in depth characterization of the recovered sorbent.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Phase 2 Methyl Iodide Deep-Bed Adsorption Tests

Nuclear fission produces fission products (FPs) and activation products, including iodine-129, which could evolve into used fuel reprocessing facility off-gas systems, and could require off-gas control to limit air emissions to levels within acceptable emission limits. Research, demonstrations, and some reprocessing plant experience have indicated that diatomic iodine can be captured with efficiencies high enough to meet regulatory requirements. Research on the capture of organic iodides has also been performed, but to a lesser extent. Several questions remain open regarding the capture of iodine bound in organic compounds. Deep-bed methyl iodide adsorption testing has progressed according to a multi-laboratory methyl iodide adsorption test plan. This report summarizes the second phase of methyl iodide adsorption work performed according to this test plan using the deep-bed iodine adsorption test system at the Idaho National Laboratory (INL), performed during the second half of Fiscal Year (FY) 2014. Test results continue to show that methyl iodide adsorption using AgZ can achieve total iodine decontamination factors (DFs, ratios of uncontrolled and controlled total iodine levels) above 1,000, until breakthrough occurred. However, mass transfer zone depths are deeper for methyl iodide adsorption compared to diatomic iodine (I2) adsorption. Methyl iodide DFs for the Ag Aerogel test adsorption efficiencies were less than 1,000, and the methyl iodide mass transfer zone depth exceeded 8 inches. Additional deep-bed testing and analyses are recommended to (a) expand the data base for methyl iodide adsorption under various conditions specified in the methyl iodide test plan, and (b) provide more data for evaluating organic iodide reactions and reaction byproducts for different potential adsorption conditions.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

FY-2016 Methyl Iodide Higher NOx Adsorption Test Report

Deep-bed methyl iodide adsorption testing has continued in Fiscal Year 2016 under the Department of Energy (DOE) Fuel Cycle Technology (FCT) Program Offgas Sigma Team to further research and advance the technical maturity of solid sorbents for capturing iodine-129 in off-gas streams during used nuclear fuel reprocessing. Adsorption testing with higher levels of NO (approximately 3,300 ppm) and NO2 (up to about 10,000 ppm) indicate that high efficiency iodine capture by silver aerogel remains possible. Maximum iodine decontamination factors (DFs, or the ratio of iodine flowrate in the sorbent bed inlet gas compared to the iodine flowrate in the outlet gas) exceeded 3,000 until bed breakthrough rapidly decreased the DF levels to as low as about 2, when the adsorption capability was near depletion. After breakthrough, nearly all of the uncaptured iodine that remains in the bed outlet gas stream is no longer in the form of the original methyl iodide. The methyl iodide molecules are cleaved in the sorbent bed, even after iodine adsorption is no longer efficient, so that uncaptured iodine is in the form of iodine species soluble in caustic scrubber solutions, and detected and reported here as diatomic I2. The mass transfer zone depths were estimated at 8 inches, somewhat deeper than the 2-5 inch range estimated for both silver aerogels and silver zeolites in prior deep-bed tests, which had lower NOx levels. The maximum iodine adsorption capacity and silver utilization for these higher NOx tests, at about 5-15% of the original sorbent mass, and about 12-35% of the total silver, respectively, were lower than for trends from prior silver aerogel and silver zeolite tests with lower NOx levels. Additional deep-bed testing and analyses are recommended to expand the database for organic iodide adsorption and increase the technical maturity if iodine adsorption processes.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Phase 1 Methyl Iodide Deep-Bed Adsorption Tests

Nuclear fission results in the production of fission products (FPs) and activation products including iodine-129, which could evolve into used fuel reprocessing facility off-gas systems, and could require off-gas control to limit air emissions to levels within acceptable emission limits. Research, demonstrations, and some reprocessing plant experience have indicated that diatomic iodine can be captured with efficiencies high enough to meet regulatory requirements. Research on the capture of organic iodides has also been performed, but to a lesser extent [Jubin 2012b]. Several questions remain open regarding the capture of iodine bound in organic compounds. Deep-bed methyl iodide adsorption testing has progressed according to a multi-laboratory methyl iodide adsorption test plan. This report summarizes the first phase of methyl iodide adsorption work performed according to this test plan using the deep-bed iodine adsorption test system at the Idaho National Laboratory (INL), performed during Fiscal Year (FY) 2013 and early FY-2014. Testing has been performed to address questions posed in the test plan, and followed the testing outline in the test plan. Tests established detection limits, developed procedures for sample analysis with minimal analytical interferences, and confirmed earlier results that show that the methyl iodide reacts when in contact with the AgZ sorbent, and not significantly in the gas flow upstream of the sorbent. The reaction(s) enable separation of the iodine from the organic moiety, so that the iodine can chemisorb onto the sorbent. The organic moiety can form other compounds, some of which are organic compounds that are detected and can be tentatively identified using GC-FID and GCMS. Test results also show that other gas constituents (NOx and/or H2O) can affect the methyl iodide reactions. With NOx and H2O present in the gas stream, the majority of uncaptured iodine exiting iodine-laden sorbent beds is in the form of I2 or HI, species that are soluble in NaOH scrubbing solution for iodine analysis. But when NOx and H2O are not present, then the majority of the uncaptured iodine exiting iodine-laden sorbent is in the form of methyl iodide. Methyl iodide adsorption efficiencies have been high enough so that initial DFs exceed 1,000 to 10,000. The methyl iodide mass transfer zone depths are estimated at 4-8 inches, possibly deeper than mass transfer zone depths estimated for I2 adsorption on AgZ. Additional deep-bed testing and analyses are recommended to (a) expand the data base for methyl iodide adsorption under various conditions specified in the methyl iodide test plan, and (b) provide more data for evaluating organic iodide reactions and reaction byproducts for different potential adsorption conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

FY-2015 Methyl Iodide Deep-Bed Adsorption Test Report

Nuclear fission produces fission and activation products, including iodine-129, which could evolve into used fuel reprocessing facility off-gas systems, and could require off-gas control to limit air emissions to levels within acceptable emission limits. Deep-bed methyl iodide adsorption testing has continued in Fiscal Year 2015 according to a multi-laboratory methyl iodide adsorption test plan. Updates to the deep-bed test system have also been performed to enable the inclusion of evaporated HNO 3 and increased NO 2 concentrations in future tests. This report summarizes the result of those activities. Test results showed that iodine adsorption from gaseous methyl iodide using reduced silver zeolite (AgZ) resulted in initial iodine decontamination factors (DFs, ratios of uncontrolled and controlled total iodine levels) under 1,000 for the conditions of the long-duration test performed this year (45 ppm CH3I, 1,000 ppm each NO and NO 2 , very low H 2 O levels [3 ppm] in balance air). The mass transfer zone depth exceeded the cumulative 5-inch depth of 4 bed segments, which is deeper than the 2-4 inch depth estimated for the mass transfer zone for adsorbing I 2 using AgZ in prior deep-bed tests. The maximum iodine adsorption capacity for the AgZ under the conditions of this test was 6.2% (6.2 g adsorbed I per 100 g sorbent). The maximum Ag utilization was 51%. Additional deep-bed testing and analyses are recommended to (a) expand the data base for methyl iodide adsorption and (b) provide more data for evaluating organic iodide reactions and reaction byproducts for different potential adsorption conditions.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Iodobutane Deep Bed Adsorption Test Report

The Department of Energy (DOE) Nuclear Technology Research and Development (NTRD) Program Material Recovery and Waste Form Development (MRWFD) Campaign Off-gas Sigma Team has supported research and development on iodine control and iodine waste forms for the past several years. As a part of this on-going research, two deep-bed iodobutane adsorption tests have been performed with higher NO x levels. High (>1,000) iodine decontamination factors (DFs, the ratios of the inlet iodine concentrations divided by the outlet iodine concentrations, when the gas flowrate is constant) were achieved with both the silver aerogel and silver zeolite sorbents. The iodine adsorption mass transfer zone (the depth of the sorbent bed in which adsorption is occurring at any specific time) for these tests was estimated at 4 inches for both sorbents under the test conditions. Silver utilization for silver aerogel sorbent reached 41% (up to 12 g adsorbed iodine per 100 g silver aerogel sorbent), while silver utilization reached 43% (up to 6.8 g adsorbed iodine per 100 g silver zeolite sorbent). These values are generally consistent with results for prior methyl iodide adsorption tests. The results also indicate that, during iodine adsorption process, the organic iodide molecule decomposes so that the iodine can be adsorbed. Even when sorbent breakthrough is reached, the organic iodide molecule continues to decompose; and the unadsorbed iodine that passes through bed is no longer in the form of the original organic iodide; but in the form of iodine compounds that are soluble in NaOH solutions, such as HI or I 2 . This research and development has included iodine adsorption tests using a laboratory-scale test system containing segmented fixed beds of iodine adsorbents in series. Non-radioactive synthetic gas mixtures were blended from air, nitrogen, NO, NO 2 , water, and the target iodine compounds to represent dissolver off-gas (DOG) streams from used nuclear fuel aqueous reprocessing.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Control of Radioactive Methyl Iodide Gases by Mesoporous Hybrid Adsorbents at High Humid Condition - 19329

During the operation of nuclear facility as well as decommissioning stage, various radioactive gaseous wastes are generated. It is generally recognized that radioiodine is potentially one of the most hazardous gas on the human body and environment. Iodine-131 release in the gaseous effluents at the nuclear facilities had been a critical environmental concern. Reducing iodine release is a critical issue in radioactive waste system evaluation, especially in their adherence to the 'as low as reasonably achievable' (ALARA) criteria because radioiodine among these gaseous wastes has radiological harm. Therefore, numerous studies for the removal of radioiodine from the off-gas stream of nuclear facilities have been performed with formation processes and chemical structure. There has been some concern regarding the use of TEDA-impregnated activated carbon as an adsorbent for radioiodine removal, because of the low ignition point of TEDA and the possible release of TEDA from the charcoal in continuously flowing air streams. Therefore, the TEDA-impregnated activated carbon cannot use to trap radioiodine generated from high humid condition, due to the rapid drop of the removal efficiency. It is obvious that high humid can be expected during design basis event such as loss-of-coolant accident (LOCA). Therefore, investigation on the retention of organic radioiodine (CH3I131) by various activated carbons at high humid condition has extensively been performed so far. But there are no good results on the adsorption of methyl iodide at high humid condition up to now. As a result, the promising approach to the problem of iodine removal under high humid conditions is to use organic-inorganic hybrid adsorbents in which are enough retention characteristics from hydrophobic property. In order to develop the best removal efficiency for the control of radioiodine gas generated from a high humid process, a hydrophobic adsorbents was developed and the performance test of adsorbent using radioactive methyl iodide tracer was also performed. Demonstration test of adsorbent using radioactive methyl iodide tracer was performed at high humid conditions up to 97% relative humidity. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Effects of moisture and aging upon decomposition of methyl iodide by reduced silver mordenite

Abstract Reduced silver mordenite has been considered as a sorbent for the capture of organic iodides, especially methyl iodide, from off-gases produced by aqueous used nuclear fuel reprocessing operations. The adsorption capacity of this material has been unpredictable especially when NO x and water are present. Previous work has found that a catalytic decomposition reaction is occurring on the surface but few determinations have been made of the kinetics of this reaction. The work presented tested the adsorption behavior and apparent catalytic reaction rate in humid conditions and compared those to dry conditions testing. Both experiments observed a first order reaction with rate constants of 0.0847 L/g sorbent/s and 0.1202 L/g sorbent/s respectively. Such a reduction in apparent rate constant is possibly due to either water obstructing methyl iodide adsorption or product desorption limitation. Changes in the adsorption profile were also apparent between these two, with the humid conditions experiment reaching saturation sooner than the dry conditions experiment. Additionally, an experiment into the effects of sorbent storage in a controlled laboratory environment was performed. The performance of the sorbent materials that were stored with silver in the zerovalent state was slightly inferior to those materials that were stored in ionic form (Ag + ) and reduced to zerovalent silver immediately prior to subjecting them to sorption test. The materials stored with silver in the ionic form (and reduced just prior to application) behaved essentially similarly to the freshly synthesized (and reduced) sorbents in the sorption tests. This suggests that zerovalent silver experiences some oxidation resulting in deactivation of some sites.

Goettsche, Heinrik↗

Performance of Silver-Exchanged Mordenite and Silver-Functionalized Silica-Aerogel Under Vessel Off-gas Conditions

US regulations 40 CFR 61, 40 CFR 190, and 10 CFR 20 govern release limits for volatile radionuclides contained in the gaseous effluents of used nuclear fuel (UNF) reprocessing facilities. Of the four volatile radionuclides that are restricted by the release limits ( 3 H, 14 C, 85 Kr, and 129 I) 129 I will require the greatest degree of abatement. Previous studies have shown that overall plant decontamination factor (DF) for 129 I must, at minimum, exceed 1,000 to meet regulatory requirements. Iodine-containing off-gas will be present in the dissolver off-gas, the cell off-gas, the vessel off-gas (VOG), the waste off-gas, and the shear off-gas. The VOG will most likely contain 1%–5% of the total iodine at part per billion (ppb) concentrations. A number of studies have examined iodine abatement from the dissolver off-gas, which contains greater than 95% of the iodine inventory of the plant, but very few have examined the recovery of iodine from the VOG stream. Reduced silver-exchanged mordenite (Ag 0 Z) has been considered a promising iodine sorbent for use in UNF reprocessing plants, but recent efforts have identified silver-functionalized silica-aerogel (AgAerogel) as a potential alternative. The testing reported here reflects a substantial increase in the body of work available on iodine adsorption by both silver sorbents under prototypical VOG conditions. Both I2 and methyl iodide (CH 3 I) adsorption tests have been conducted with Ag 0 Z and AgAerogel at a range of concentrations up to 1,000 ppb. These experiments were performed with two specific aims: (1) to assess the effect of iodine concentration on its adsorption by the sorbent and (2) to compare the performance of Ag 0 Z and AgAerogel in the removal of iodine from a prototypical VOG stream.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Initial Effects of NO x on Idodine and Methyl Iodine Loading of AgZ and Aerogels

This initial evaluation provides insight into the effect of NO on the adsorption of both I 2 and CH 3 I onto reduced silver-exchanged mordenite (Ag 0 Z). It was determined that adsorption of CH 3 I onto Ag 0 Z occurs at approximately 50% of the rate of I 2 adsorption onto Ag 0 Z, although total iodine capacities are comparable. Addition of 1% NO to the simulated off-gas stream results in very similar loading behaviors and iodine capacities for both iodine species. This is most likely an effect of CH 3 I oxidation to I 2 by NO prior to contact with the sorbent bed. Completion of tests including NO 2 in the simulated off-gas stream was delayed due to vendor NO 2 production schedules. A statistically designed test matrix is partially completed, and upon conclusion of the suggested experiments, the effects of temperature, NO, NO 2 , and water vapor on the sorption of CH 3 I and I 2 onto Ag 0 Z will be able to be statistically resolved. This work represents progress towards that aim.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Quantify the Extent of Physisorption on Silver Based Sorbents under VOG Conditions

US regulations govern release limits for volatile radionuclides contained in the gaseous effluents of used nuclear fuel reprocessing facilities. Of the four volatile radionuclides that are most restricted by the release limits ( 3 H, 14 C, 85 Kr, and 129 I), 129 I will require the greatest degree of abatement. Within a reprocessing facility, the vessel off-gas stream will likely contain 1%–5% of the total iodine at parts per billion (ppb) concentrations. Studies conducted by the authors have now investigated both I 2 and methyl iodide (CH 3 I) adsorption by two silver-bearing sorbents, hydrogen-reduced silver-exchanged mordenite (Ag 0 Z) and silver functionalized aerogel (AgAerogel) at a range of concentrations up to 1,000 ppb. Throughout this suite of tests, and particularly in the case of CH3I adsorption tests, there was a significant discrepancy in the amount of iodine recovered on sorbent beds compared to the amount of iodine that was believed to be delivered to the test system.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Adsorption of Radioactive Iodine Using Nanocarbon on ETS-10 as Adsorbent

Here, laboratory-synthesized nanocarbon pelletized with titanosilicate (ETS-10) as a support matrix has been investigated for the capture of radioactive iodine present as methyl iodide (CH 3 I) in the off-gas streams produced during aqueous reprocessing of used nuclear fuel. The mass fraction of carbon in the sorbent matrix was 0.10. The effects of residence time and CH 3 I concentration were investigated using a continuous flow column setup to quantify the adsorption and desorption capacities of adsorbent under dynamic conditions from an air stream containing CH 3 I present at concentrations representative of those expected in the off-gas streams. Air with CH 3 I gas as a source in the column resulted in quantifiable CH 3 I adsorption with 0.98 mg/g of adsorption capacity. Laboratory-made nanocarbons had a larger adsorption capacity than those of the other carbons reported in the literature. Additionally, the adsorption capacity of nanocarbon on ETS-10 is compared to that of nanocarbon coated on cordierite in previous studies.

ETS-10↗

Impact of Pretreatment and Aging on the Iodine Capture Performance of Silver-Exchanged Mordenite - 12314

Volatile gas emissions from a nuclear fuel recycle facility in the United States are governed by several key regulations, including 10 CFR 20, 40 CFR 61, and 40 CFR 190. Under 40 CFR 190, the total quantity of iodine that may be released to the environment from the entire fuel cycle is limited to 5 millicuries of I-129 per gigawatt-year of electrical energy produced by the fuel cycle. With a reasonable engineering margin, an iodine decontamination factor (DF) of approximately 1000 will be required for the complete fuel cycle. Off-gas treatment in a fuel reprocessing plant must address several gas streams containing iodine, among a number of volatile radionuclides. Past research and developmental activities identified silver-exchanged mordenite (AgZ) as a very promising sorbent based on its acid resistance, relatively high iodine and methyl iodide capacity, and high achievable DF. Recent studies at ORNL have focused on the impacts of long-term exposure to simulated off-gas streams (aging) and pretreatment on the iodine adsorption performance of hydrogen-reduced silver-exchanged mordenite (Ag{sup 0}Z). Experiments were conducted to determine the effects of long-term exposure to both dry and moist air on the iodine sorption capacity of Ag{sup 0}Z. The data indicates that aging reduces the capacity of Ag{sup 0}Z, which must be accounted for to prevent degradation of DF. Because of its high acid resistance, a AgZ sorbent has been selected specifically for application in treating off-gas streams containing iodine. While extensive tests have been conducted in the United States on a form of this sorbent, the specific material previously tested is no longer commercially available and similar materials are currently being evaluated. As part of this evaluation, tests were conducted to determine the iodine sorption properties of this replacement media and the effects of long-term (up to 6 months) exposure to simulated off-gas streams. The ultimate goal is to develop an understanding of the fundamental phenomena that controls aging for this material and other zeolites that could be considered for use in off-gas treatment in the future. The trends in the study results indicate that the amount of elemental silver observed by XRD increases from 0.3 wt% in vendor-supplied AgZ to approximately 5 wt% by reducing the material with hydrogen. The study also concluded that aging decreases the quantity of elemental silver in the material. After 2 months of aging, the Ag{sup 0} content of an experimental sample was reduced from 5 wt% to about 1.3 wt%. The form into which the elemental silver is converted during aging was not determined. Experimental tests have been initiated to study how aging of Ag{sup 0}Z impacts iodine loading on the zeolite. Loading tests with un-aged Ag{sup 0}Z resulted in an 81% silver utilization. The loading capacity of iodine on Ag{sup 0}Z was reduced with aging in dry air. Material aged for 6 months in dry air had a 40% reduction in iodine loading capacity. Under moist-air aging conditions, a significant decrease in the rate and total loading (∼45% of theoretical) of iodine uptake can be observed beginning with the shortest aging period (i.e., after 1 month) when compared with the loading curve using Ag{sup 0}Z with no aging. Increasing exposure time to the humid air used to age the Ag{sup 0}Z beyond 1 month resulted in a slight additional reduction in capacity to about 35% of theoretical at 2 months. Virtually identical capacity was observed with 4 months of aging. Compared to the non-aged material, the 1 month dry-air aged Ag{sup 0}Z shows about a 35% reduction (approximate) in iodine loading capacity and the 6 month dry-air aged Ag{sup 0}Z shows about a 50% reduction. These studies generated several questions that will be addressed in future tests. They include the following: Is there indeed degradation over time (in storage) in the iodine adsorption performance of Ag{sup 0}Z? Once reduced, how should the Ag{sup 0}Z be stored- under a hydrogen atmosphere, an inert atmosphere, a desiccant, or some other method or combination of methods? Does Ag{sup 0}Z have a 'shelf life' that must be considered after receipt from a vendor and before use in a plant? Also, how should a column of Ag{sup 0}Z be stored offline in a processing plant (parallel column) arrangement? Future tests will also include increasingly challenging aging environments such as acid vapor conditions. (authors)

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Organic Iodine Adsorption by AgZ under Prototypical Vessel Off-Gas Conditions

U.S. regulations will require the removal of 129 I from the off-gas streams of any used nuclear fuel (UNF) reprocessing plant prior to discharge of the off-gas to the environment. Multiple off-gas streams within a UNF reprocessing plant combine prior to release, and each of these streams contains some amount of iodine. For an aqueous UNF reprocessing plant, these streams include the dissolver off-gas, the cell off-gas, the vessel off-gas (VOG), the waste off-gas and the shear off-gas. To achieve regulatory compliance, treatment of multiple off-gas streams within the plant must be performed. Preliminary studies have been completed on the adsorption of I 2 onto silver mordenite (AgZ) from prototypical VOG streams. The study reported that AgZ did adsorb I 2 from a prototypical VOG stream, but process upsets resulted in an uneven feed stream concentration. The experiments described in this document both improve the characterization of I 2 adsorption by AgZ from dilute gas streams and further extend it to include characterization of the adsorption of organic iodides (in the form of CH 3 I) onto AgZ under prototypical VOG conditions. The design of this extended duration testing was such that information about the rate of adsorption, the penetration of the iodine species, and the effect of sorbent aging on iodine removal in VOG conditions could be inferred.

11 NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗