Search NASA⌕ Search

SEARCH · Search NASA

Results for “micro X-ray CT imaging”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Physical model and experimental validation of a high temperature proton exchange membrane electrochemical hydrogen pump cell for efficient single-stage extraction of low concentration hydrogen gas

There is interest in valorization of existing natural gas infrastructure to facilitate the co-transportation of hydrogen via blending of hydrogen gas initially at limited concentrations of 1–20 vol% H2 and to subsequently extract hydrogen at fuel cell quality standards (SAE J2719/ISO14687-2). High temperature proton exchange membrane electrochemical hydrogen pump (HT-PEM EHP) based on phosphoric acid doped polybenzimidazole (PA-PBI) exhibits good performance at elevated temperatures (>120 °C), which provides desirable tolerance to non-methane natural gas constituents that are problematic for lower temperature based EHP. To better understand the suitability of the HT-PEM EHP for such gas separation processes, a two-dimensional model of EHP based on PA-PBI was developed. The model is validated for several relevant operating conditions and across cells with differing amounts of phosphoric acid content in the electrodes. Operando micro x-ray computed tomography (CT) imaging of an HT-PEM EHP was used to further validate physical parameters and assumptions of the model. The impacts of pressure, relative humidity of the anode feed, and concentration of feed gases on separation performance are investigated. This study shows that a specific energy of separation of 5.1 kWh/kg H2 at a hydrogen recovery factor (HRF) of 50 vol% can be achieved in a single stage with the EHP, producing fuel cell quality hydrogen purity of 99.99 vol% H2 from a 2 vol% H2/CH4 feed blend, while pressurizing the product H2 at a pressure ratio of 1.3 relative to feed pressure.

Stansberry, John M↗

Effect of Tube-Based X-Ray Microtomography Imaging on the Amino Acid and Amine Content of the Murchison CM2 Chondrite

X-ray and synchrotron X-ray micro-computed tomography (micro-CT) are increasingly being used for three dimensional reconnaissance imaging of chondrites and returned extraterrestrial material prior to detailed chemical and mineralogical analyses. Although micro-CT imaging is generally considered to be a non-destructive technique since silicate and metallic minerals in chondrites are not affected by X-ray exposures at the intensities and wavelengths typically used, there are concerns that the use of micro-CT could be detrimental to the organics in carbonaceous chondrites. We recently conducted a synchrotron micro-CT experiment on a powdered sample of the Murchison CM2 carbonaceous chondrite exposed to a monochromatic high energy (approximately 48 kiloelectronvolts) total X-ray radiation dose of approximately 1 kilogray (kGy) using the Advanced Photon Source beamline 13-BMD (13-Bending Magnet-D Beamline) at Argonne National Laboratory and found that there were no detectable changes in the amino acid abundances or enantiomeric compositions in the chondrite after exposure relative to a Murchison control sample that was not exposed. However, lower energy bremsstrahlung X-rays could interact more with amino acids and other lower molecular weight amines in meteorites. To test for this possibility, three separate micro-CT imaging experiments of the Murchison meteorite using the GE Phoenix v/tome/x s 240 kilovolt microfocus high resolution tungsten target X-ray tube instrument at the American Museum of Natural History (AMNH) were conducted and the amino acid abundances and enantiomeric compositions were determined. We also investigated the abundances of the C1-C5 amines in Murchison which were not analyzed in the first study.

Microtomography Imaging↗

Gas pore correlations in laser powder bed fusion of Al6061

Additive manufacturing (AM) of metal materials based on powder bed fusion technology is widely used now in many industries. A known limitation of this type of manufacturing is the formation of gas pores in the bulk material. Here we present a combined X-ray imaging and mid-infrared pyrometry study of pore formation in side-by-side tracks of Al6061 for different processing conditions using both in-situ and post-processing analysis. By carefully quantifying the distributions and correlations of pore positions, we show that an existing pore in one track often catalyzes the formation of another pore in an adjacent track. In a raster scan strategy commonly used to construct bulk material, this phenomenon has the result of forming subsurface perforations, or lines of pores transverse to the scanning direction in a rastered patch. If controlled, this effect can be eliminated to improve the yield strength of the build, or exploited to create programmable failures for specific purposes.

36 MATERIALS SCIENCE↗

Computed Tomography Scanning and Petrophysical Measurements of Eastern Williston Basin Twin Buttes and Hagel Formations

The computed tomography (CT) facilities and the Multi-Sensor Core Logger (MSCL) at the U.S. Department of Energy’s (DOE) National Energy Technology Laboratory (NETL) in Morgantown, West Virginia, were used to characterize core from two wells that represent coal resources across North Dakota. These include the MC23080C Well in Mercer County and the 23-B001 Well in Oliver County. The primary impetus of this work was to capture a detailed digital representation of the core from the MC23080C and 23-B001 Wells. The collaboration between the NETL and the Energy and Environment Research Center (EERC) enables other research entities to access information about this potential carbon ore, rare earth, and critical mineral resource plays in the Williston Basin. All equipment and techniques used were non-destructive, enabling future examinations and analyses to be performed on these cores. Fractures, discontinuities, and millimeter-scale features were readily detectable with the medical CT scanner acquired images. Imaging with the NETL medical CT scanner was performed on entire cores. Qualitative analysis of the medical CT images, coupled with X-ray fluorescence (XRF), gamma density, and magnetic susceptibility measurements from the MSCL were useful in identifying zones of interest for potential future analysis. Higher-resolution industrial and micro-CT images were acquired from selected zones along the depth of the core to visualize the structure in higher detail. The ability to quickly identify key areas for more detailed study with higher resolution will save time and resources in future studies. The combination of methods used provides a multi-scale analysis of the core, with the resulting macro- and micro-descriptions relevant to many subsurface energy-related examinations traditionally performed at NETL.

01 COAL, LIGNITE, AND PEAT↗

Nondestructive Analysis of Astromaterials by Micro-CT and Micro-XRF Analysis for PET Examination

An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of the PET is to characterize and classify returned samples and make this information available to the larger research community who then conduct more in-depth studies on the samples. The PET tries to minimize the impact their work has on the sample suite, which has in the past limited the PET work to largely visual, nonquantitative measurements (e.g., optical microscopy). More modern techniques can also be utilized by a PET to nondestructively characterize astromaterials in much more rigorous way. Here we discuss our recent investigations into the applications of micro-CT and micro-XRF analyses with Apollo samples and ANSMET meteorites and assess the usefulness of these techniques in future PET. Results: The application of micro computerized tomography (micro-CT) to astromaterials is not a new concept. The technique involves scanning samples with high-energy x-rays and constructing 3-dimensional images of the density of materials within the sample. The technique can routinely measure large samples (up to approx. 2700 cu cm) with a small individual voxel size (approx. 30 cu m), and has the sensitivity to distinguish the major rock forming minerals and identify clast populations within brecciated samples. We have recently run a test sample of a terrestrial breccia with a carbonate matrix and multiple igneous clast lithologies. The test results are promising and we will soon analyze a approx. 600 g piece of Apollo sample 14321 to map out the clast population within the sample. Benchtop micro x-ray fluorescence (micro-XRF) instruments can rapidly scan large areas (approx. 100 sq cm) with a small pixel size (approx. 25 microns) and measure the (semi) quantitative composition of largely unprepared surfaces for all elements between Be and U, often with sensitivity on the order of a approx. 100 ppm. Our recent testing of meteorite and Apollo samples on micro-XRF instruments has shown that they can easily detect small zircons and phosphates (approx. 10 m), distinguish different clast lithologies within breccias, and identify different lithologies within small rock fragments (2-4 mm soil Apollo soil fragments).

Zeigler, R. A.↗

From Tomography to Material Properties of Thermal Protection Systems

A NASA Ames Research Center (ARC) effort, under the Entry Systems Modeling (ESM) project, aims at developing micro-tomography (micro-CT) experiments and simulations for studying materials used in hypersonic entry systems. X-ray micro-tomography allows for non-destructive 3D imaging of a materials micro-structure at the sub-micron scale, providing fiber-scale representations of porous thermal protection systems (TPS) materials. The technique has also allowed for In-situ experiments that can resolve response phenomena under realistic environmental conditions such as high temperature, mechanical loads, and oxidizing atmospheres. Simulation tools have been developed at the NASA Ames Research Center to determine material properties and material response from the high-fidelity tomographic representations of the porous materials with the goal of informing macroscopic TPS response models and guiding future TPS design.

Tomography↗

Effect of Ex Vivo Ionizing Radiation on Static and Fatigue Properties of Mouse Vertebral Bodies

For a variety of medical and scientific reasons, human bones can be exposed to a wide range of ionizing radiation levels. In vivo radiation therapy (0.05 kGy) is used in cancer treatment, and ex vivo irradiation (25-35 kGy) is used to sterilize bone allografts. Ionizing radiation in these applications has been shown to increase risk of fracture, decrease bone quality and degrade collagen integrity. Past studies have investigated the deleterious effects of radiation on cortical or trabecular bone specimens individually, but to date no studies have examined whole bones containing both cortical and trabecular tissue. Furthermore, a clear relationship between the dose and the mechanical and biochemical response of bone's extracellular matrix has yet to be established for doses ranging from cancer therapy to allograft sterilization (0.05-35 kGy). To gain insight into these issues, we conducted an ex vivo radiation study to investigate non-cellular (i.e. matrix) effects of ionizing radiation dose on vertebral whole bone mechanical properties, over a range of radiation doses (0.05-35 kGy), with a focus on any radiation-induced changes in collagen. With underlying mechanisms of action in mind, we hypothesized that any induced reductions in mechanical properties would be associated with changes in collagen integrity. METHODS: 20-week old female mice were euthanized and the lumbar spine was dissected using IACUC approved protocols. The lumbar vertebrae (L1- S1) were extracted from the spine via cuts through adjacent intervertebral discs, and the endplates, posterior processes, surrounding musculature, and soft tissues were removed (approx. 1.5mm diameter, approx. 2mm height). Specimens were randomly assigned to one of five groups for ex vivo radiation exposure: x-ray irradiation at 0.05, 1, 17, or 35 kGy, or a 0 kGy control. Following irradiation, the vertebrae were imaged using microcomputed tomography (micro-CT) and then subjected to either monotonic compressive loading to failure or uniform cyclic compressive loading. During cyclic testing, samples were loaded in force control to a force level that corresponded to a strain of 0.46%, as determined in advance by a linearly elastic micro-CT-based finite element analysis for each specimen. Tests were stopped at imminent fracture, defined as a rapid increase in strain. The main outcome for the monotonic test was the strength (maximum force); for cyclic testing it was the fatigue life (log of the number of cycles of loading at imminent failure). A fluorometric assay was used on the S1 vertebrae to measure the number of non-enzymatic collagen crosslinks[4]. A one-way ANOVA was performed on mechanical properties and collagen crosslinks; means were compared with controls using Dunnett's method, with a Tukey-Kramer post-hoc analysis when significance was found (p < or = 0.05). RESULTS: Compared to the unirradiated control group, the concentration of non-enzymatic collagen crosslinks was significantly increased for all irradiated groups (p < 0.0001), and being higher by at least 50% (Figure 1a). By contrast, the radiation effects on the collagen were only evident at the higher doses. For irradiation exposures of 17 kGy or more, strength decreased substantially as the radiation level was increased, but no effect was evident below 17 kGy (Figure 1b). There was no significant change in the stiffness or maximum displacement for any radiation dose (p>0.05). The finite element analysis prescribed force level for cyclic loading exceeded the measured (monotonic) strength of the 17 and 35 kGy irradiated groups (mean +/- SD, 20.6 +/- 5.6 N; 13.2 +/- 3.7 N, respectively) and therefore these groups were eliminated from the fatigue study. The fatigue life for the 0.05 and 1 kGy groups were similar to each other and were not statistically significantly different from the control group (Figure 1c).

radiation↗

Effect of cell compression on the performance and the structure of proton exchange membrane water electrolyzer (PEMWE) assembly

Here, in the field of water electrolysis, the proton exchange membrane water electrolyzer (PEMWE) is currently the most advanced technology for producing hydrogen without emitting CO 2 . Although PEMWE plants are already in operation, further research is needed to improve cell efficiency and reduce the use of rare materials, such as iridium oxide catalysts for the oxygen evolution reaction (OER). One of the main causes of performance loss in PEMWE is the relatively low electric conductivity of the porous transport layer (PTL) and of the anode catalyst layer, which results in ohmic losses and low catalyst utilization during high current density operation. The objective of this study is to investigate how optimization of the PTL and electrode interface can increase the cell performance. To this end, we tested different cell assemblies using fibrous and sintered PTLs, decreasing membrane thickness, reducing iridium loading, and inserting a microporous layer to increase contact surface area. Electrochemical characterization of each cell configuration was systematically performed at various compression levels as the pressure is a crucial parameter influencing the electrode/PTL contact area. In parallel, X-ray microcomputed tomography (micro-CT) was employed to investigate the effects of cell hydration and compression on the structure of PEMWE components. This study combining electrochemistry and micro-CT imaging presents how optimizing the electrode/PTL contact surface area, minimizes ohmic losses, and enables PEMWE operation with low iridium loading at high current densities.

Catalyst - PTL interface↗

Predictive Modeling of Carbon Ablators

Efforts to build a Predictive Material Modeling (PMM) framework from the micro-scale to the macro-scale are presented in this abstract. To reduce the need for extensive testing, accelerate the design cycle process, and reduce uncertainty margins applied to final designs, NASA is developing simulation and modeling tools that enable characterization of material properties and response to high-enthalpy environments. The Porous Microstructure Analysis (PuMA) code has been developed for computing macroscale (volume averaged) properties of porous materials using microscale images from micro-computed tomography (micro-CT). Microscale modeling requires a realistic representation of a material microstructure; these are obtained either synthetically during the design of the material or through X-ray micro-CT. Volume averaged properties are then used to inform macroscale material response models, such as those implemented in the Porous-material Analysis Toolbox based on OpenFOAM (PATO) software, also actively developed by NASA. The computational model in PATO is a generic heat and mass transfer model for porous reactive materials containing several solid phases and a single gas phase. The detailed chemical interactions occurring between the solid phases and the gas phase are modeled at the pore scale assuming local thermal equilibrium. These tools were developed to efficiently interface with other pre-existing codes such as SPARTA (direct simulation Monte Carlo), DPLR (hypersonic CFD), NEQAIR (radiative transport) and DAKOTA (uncertainty quantification and optimization). Detailed flight data (Mars Science Laboratory [MSL] Entry Descent and Landing Instrument [MEDLI]) is critical for validating these computational tools for NASA applications. Examples of modeling ablative material response using these codes will be presented including 3D simulations of the full-scale heatshield of the MSL capsule. The simulations demonstrate the ability of the modern material response code, PATO, to handle the material response of geometrically complex and large domains, through the use of massively parallel computations.

Thermal Protection Systems↗

Predictive Modeling of Carbon Ablators Using Micro and Macro-Scale Modeling

Efforts to build a Predictive Material Modeling (PMM) framework from the micro-scale to the macro-scale are presented in this abstract. To reduce the need for extensive testing, accelerate the design cycle process, and reduce uncertainty margins applied to final designs, NASA is developing simulation and modeling tools that enable characterization of material properties and response to high-enthalpy environments. The Porous Microstructure Analysis (PuMA) code has been developed for computing macroscale (volume averaged) properties of porous materials using microscale images from micro-computed tomography (micro-CT). Microscale modeling requires a realistic representation of a material microstructure; these are obtained either synthetically during the design of the material or through X-ray micro-CT. Volume averaged properties are then used to inform macroscale material response models, such as those implemented in the Porous-material Analysis Toolbox based on OpenFOAM (PATO) software, also actively developed by NASA. The computational model in PATO is a generic heat and mass transfer model for porous reactive materials containing several solid phases and a single gas phase. The detailed chemical interactions occurring between the solid phases and the gas phase are modeled at the pore scale assuming local thermal equilibrium. These tools were developed to efficiently interface with other pre-existing codes such as SPARTA (direct simulation Monte Carlo), DPLR (hypersonic CFD), NEQAIR (radiative transport) and DAKOTA (uncertainty quantification and optimization). Detailed flight data (Mars Science Laboratory [MSL] Entry Descent and Landing Instrument [MEDLI]) is critical for validating these computational tools for NASA applications. Examples of modeling ablative material response using these codes will be presented including 3D simulations of the full-scale heatshield of the MSL capsule. The simulations demonstrate the ability of the modern material response code, PATO, to handle the material response of geometrically complex and large domains, through the use of massively parallel computations.

Thermal Protection Systems↗

X-Ray Micro- and Nano-Tomography Analysis of Bennu Samples: A Preliminary Report

X-ray tomography (XCT) is an effective technique for obtaining the 3D structures of returned samples. XCT using synchrotron radiation provides high-resolution CT images with quantitative information. The XCT systems at SPring-8, an SR facility in Japan, have been used to analyze samples returned from the asteroids Itokawa and Ryugu. In this study, we plan to apply SR-XCT to samples returned from the asteroid Bennu.

A Tsuchiyama↗

Search for Organic Nanoglobules in Carbonaceous Chondrites Using Microtomography

Primitive solar materials have various organic matters. In recent years, novel organic materials called organic nanoglobules of a few hundred micrometers in typical size were discovered in carbonaceous chondrites, IDPs, and comet 81P/Wild 2. The organic globules are spherical shape and in many cases with hollow structures. Composition of the globules are mainly aromatic carbon. The isotopic anomalies of SD and 6N 15 observed in the globules indicate that they were formed from photochemical reaction to ice particles at very low temperature environment, such as molecular clouds or outer protosolar disk. Aqueous alteration of organic matters and the gamma-ray irradiation to PAH are also suggested as alternative possible formation processes. If the globules are made from organic ice particles, the hollow regions of the globules are suggested to be once filled with volatile H20-rich organic ices, while if they were formed by aqueous alteration, the hollow regions should be filled with a fluid which caused the aqueous alteration. However, fluids in the globules have not been detected so far in the previous studies. If fluids were originally preserved in the hollows, they might be lost during destructive processes of sample separation or preparation for TEM observation. X-ray computed tomography (CT) is a nondestructive method which can determine 3-D internal structures of objects. SR (synchrotron radiation)-based imaging microtomography can give submicron spatial resolution [8] and was applied to micro textures in extraterrestrial materials, such as cometary grains captured by the Stardust mission [9]. If organic globules are observed non-destructively in carbonaceous chondrites by tomography, we can check the presence of fluids in the hollows. If fluids are preserved, we may analyze chemical and isotopic compositions of the fluids. The purpose of this study is to observe organic nanoglobules using imaging tomography for future analysis.

Matsumoto, T.↗

Curating NASA's Past, Present, and Future Extraterrestrial Sample Collections

As codified in NASA Policy Directive 7100.10F, the Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC Curation) is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. JSC Curation curates all or part of nine astromaterial collections in seven clean room suites: (1) Apollo Samples (1969; ISO 6-7), (2) Luna Samples (from USSR; 1972; ISO 7), (3) Antarctic Meteorites (1976; ISO 7), (4) Cosmic Dust (1981; ISO 5), (5) Microparticle Impact Collection (formerly called Space Exposed Hardware; 1985; ISO 5), (6) Genesis Solar Wind Atoms (2004; ISO 4); (7) Stardust Comet Particles (2006; ISO 5), (8) Stardust Interstellar Particles (2006; ISO 5), (9) Hayabusa Asteroid Particles (from JAXA; 2010; ISO 5). In addition to the labs that house the samples, we have installed and maintained a wide variety of facilities and infrastructure required to support the clean-rooms: more than 10 different HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system (UPW) and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam (FIB) sections to meet the research requirements of scientists. To ensure that we are keeping the samples as pristine as possible, we routinely monitor the cleanliness of our clean rooms and infrastructure systems. This monitoring includes: daily monitoring of the quality of our UPW, weekly airborne particle counts in the labs, monthly monitoring of the stable isotope composition of the gaseous N2 system, and annual measurements of inorganic or organic contamination in processing cabinets. We track within our databases the current and ever-changing characteristics of more than 250,000 individual samples across our various collections (including the 19,141 samples on loan to 433 Principal Investigators in 24 countries). The next sample return missions that NASA will participate in are Hayabusa2 and OSIRIS-REx (Origins Spectral Interpretation Resource Identification Security - Regolith Explorer). The designs for a new state-of-the-art suite of clean rooms to house these samples at JSC have been finalized. This includes separate ISO class 5 clean rooms to house each collection, a common ISO class 7 area for general use, an ISO class 7 microtome laboratory, and a separate thin section lab. Additionally, a new cleaning facility is being designed and procedures developed that will allow for enhanced cleaning of cabinets and tools in an inorganically, organically, and biologically clean manner. We are also designing a large multi-purpose Advanced Curation laboratory that will allow us to develop the techniques necessary to fully support the Hayabusa2 and OSIRIS-REx missions, as well as future possible sample return missions (e.g., Lunar Polar Volatiles, Mars, Comet Surface). A micro-CT (micro Computed Tomography) laboratory dedicated to the study of astromaterials has come online within JSC Curation, and we plan to add additional facilities that will enable non-destructive (or minimally-destructive) analyses of astromaterials in the near future (e.g., micro-XRF (micro X-Ray Fluorescence), confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions, (2) be utilized by PET (Positron Emission Tomography) for future sample return missions, (3) for retroactive PET-style analyses of our existing collections, and (4) for periodic assessments of the existing sample collections.

Zeigler, Ryan A.↗

Brady’s Geothermal Field Computed Tomography Core Characterization

We present a publicly accessible database centered around multi-scale Computed Tomographic (CT) imaging of samples from the BCH-03 well, supplemented by a wide range of supporting geological analyses (Brown, et al., 2022). The data include detailed petrologic descriptions of core samples, core-scale medical CT scans, high-resolution micro-CT scans, thin section photomicrographs, elemental abundance data from X-ray diffraction, velocity wave measurements, and helium porosimetry of the matrix.

computed tomography↗

High Resolution X-Ray Micro-CT of Ultra-Thin Wall Space Components

A high resolution micro-CT system has been assembled and is being used to provide optimal characterization for ultra-thin wall space components. The Glenn Research Center NDE Sciences Team, using this CT system, has assumed the role of inspection vendor for the Advanced Stirling Convertor (ASC) project at NASA. This article will discuss many aspects of the development of the CT scanning for this type of component, including CT system overview; inspection requirements; process development, software utilized and developed to visualize, process, and analyze results; calibration sample development; results on actual samples; correlation with optical/SEM characterization; CT modeling; and development of automatic flaw recognition software. Keywords: Nondestructive Evaluation, NDE, Computed Tomography, Imaging, X-ray, Metallic Components, Thin Wall Inspection

Roth, Don J.↗

Pore-scale visualization of natural hydrate-bearing sediments

Accurate modeling of gas hydrate reservoir productivity and geomechanical risks associated with subsurface dissociation of natural gas hydrates (NGH) requires the determination of model parameters through physical testing on natural hydrate-bearing sediments (HBS). This involves investigating the hydro-mechanical behavior of undisturbed hydrate samples from nature under in situ conditions using pressure core characterization and analysis, which provides a unique opportunity for research. By employing state-of-the-art micro computed tomography imagery on cryogenically preserved, hydrate-bearing sediment samples, we can determine hydrate saturation as well as permeability with and without the presence of hydrates in the sediment. Furthermore, utilizing a machine learning based image segmentation technique, it is possible to extract pore space and grain information. Subsections of the entire image volume were used to determine anisotropic permeabilities using a finite-difference method Stokes solver (FDMSS). Additionally, permeability measurements on whole pressure and temperature preserved hydrate-bearing core were analyzed by utilizing the National Energy Technology Laboratory’s (NETL) Pressure Core Characterization and X-ray CT Visualization Tool (PCXT) to manipulate, cut, and analyze pressure preserved sediment. Permeabilities were measured under a broad range of vertical stress states to simulate expected pressure changes during production scenarios, and the results show that permeabilities derived from images are in agreement with those from traditional core derived experiments. The collected stress-dependent permeability, permeability anisotropy, and corresponding gas hydrate saturations provide valuable input into numerical simulations of reservoir productivity. These properties have been proven to be key parameters determining a long-term reservoir response under depressurization.

Liu, Mengwei [Oak Ridge Institute for Science and ↗

Search for Fluid Inclusions in a Carbonaceous Chondrite Using a New X-Ray Micro-Tomography Technique Combined with FIB Sampling

Early solar system aqueous fluids are preserved in some H chondrites as aqueous fluid inclusions in halite (e.g., [1]). Although potential fluid inclusions are also expected in carbonaceous chondrites [2], they have not been surely confirmed. In order to search for these fluid inclusions, we have developped a new X-ray micro-tomography technique combined with FIB sampling and applied this techniqu to a carbanaceous chondrite. Experimental: A polished thin section of Sutter's Mill meteorite (CM) was observed with an optical microscope and FE-SEM (JEOL 7001F) for chosing mineral grains of carbonates (mainly calcite) and sulfides (FeS and ZnS) 20-50 microns in typical size, which may have aqueous fluid inclusions. Then, a "house" similar to a cube with a roof (20-30 microns in size) is sampled from the mineral grain by using FIB (FEI Quanta 200 3DS). Then, the house was atached to a thin W-needle by FIB and imaged by a SR-based imaging microtomography system with a Fresnel zone plate at beamline BL47XU, SPring-8, Japan. One sample was imaged at two X-ray energies, 7 and 8 keV, to identify mineral phases (dual-enegy microtomography: [3]). The size of voxel (pixel in 3D) was 50-80 nm, which gave the effective spatial resolution of approx. 200 nm. A terrestrial quartz sample with an aqueous fluid inclusion with a bubble was also examined as a test sample by the same method. Results and discussion: A fluid inclusion of 5-8 microns in quartz was clearly identified in a CT image. A bubble of approx. 4 microns was also identified as refraction contrast although the X-ray absorption difference between fluid and bubble is small. Volumes of the fluid and bubble were obtained from the 3D CT images. Fourteen grains of calcite, two grains of iron sulfide and one grain of (Zn,Fe)S were examined. Ten calcite, one iron sulfide and one (Zn,Fe)S grains have inclusions >1 micron in size (the maximum: approx. 5 microns). The shapes are spherical or irregular. Tiny inclusions (<1 micron) are also present in all the grains examined. These results show that mineral grains have more inclusions than expected from 2D observations. The X-ray absorption of the inclusions shows that they are not solid inclusions. No bubbles were observed inside, indicating that we cannot determine whether they are really aqueous fluids or merely voids. One calcite grain has an inclusion approx. 2 microns in size, which seems to have a bubble and a tiny solid daughter crystal inside (three-phase inclusion). As we know the exact 3D position of the inclusion, we will anlyze the inclusion by SIMS after freezing the sample as has been done for a halite sample [3]. The present technique is useful for finding small inclusions not only in carbonaceous chondrites but also for terrestrial materials.

Tsuchiyama, A.↗

Evaluation of desiccation cracking characteristics of inorganic micro-fiber-reinforced engineered barrier material (IMEBM) for geological repository

Abstract Buffer material is crucial for the engineering barrier system to dispose of high-level radioactive waste in a geological repository. A reliable buffer material should be able to maintain good sealing characteristics and minimize desiccation cracking. In this study, the effectiveness of inorganic fiber-reinforced engineering barrier material in reducing desiccation cracks in bentonite was evaluated via desiccation tests, image analysis, and air permeability tests. The effects of fiber type (E-glass fiber and basalt fiber) and fiber content (0.0%, 0.5%, 1.0%, 1.5%, 3.0%, and 5.0% of dry weight of the bentonite) on the development of desiccation cracks in the fiber–bentonite mixtures with the same given initial moisture content were evaluated. The results indicated that the addition of fibers could significantly reduce the crack size and area in bentonite during the drying. Basalt fibers showed a slightly better reinforcement effect than E-glass fibers when the fiber content was lower than 3.0%. The addition of fibers prevented the development of penetrating cracks and significantly reduced the permeability of the bentonite after drying. The permeabilities of basalt fiber- and E-glass fiber-reinforced bentonite composites with 3% reinforcement were 5.81 × 10 –11 m 2 and 7.24 × 10 –11 m 2 , respectively, which were 64 and 51 times smaller than that of pure bentonite. X-ray–CT observation of the internal structure of the samples after drying showed that the addition of fibers significantly changed the crack morphology and potentially increased the tortuosity.

Feng, Yuan↗