Search NASA⌕ Search

SEARCH · Search NASA

Results for “micro instruments”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Dynamic Evaluation of the Upper Tyler Formation and Well Stimulation Fluid Interactions Using Micro-CT Imaging

Abundant concentrations of swelling clays in the oil-bearing upper Tyler Formation inhibit unconventional well stimulation techniques and associated long-term oil and gas production success. Laboratory evaluation of the geochemical interactions between the formation material and various stimulation fluids may help identify innovative approaches that provide a solution to successful well stimulation and subsequent oil production. The objective of this research was to understand the complexities of well stimulation fluid and clay mineral interactions within the Tyler Formation and identify potential fracturing fluid formulations that mitigate swelling properties of the clays in the reservoir to enhance stimulation success and promote long-term oil and gas production. Collaboration with the National Energy Technology Laboratory (NETL), utilizing their Tescan DynaTOM micro-CT analysis instrumentation, provided an innovative approach to understand real-time, dynamic interactions of the formation material and various potential stimulation fluids. Results are anticipated to identify key mechanisms occurring at the micro-scale level and provide insight into modified stimulation techniques uniquely suited for successful production applications.

enhanced oil recovery↗

Reaching the potential of electron diffraction

Microcrystal electron diffraction (MicroED) is an emerging structural technique in which submicron crystals are used to generate diffraction data for structural studies. Structures allow for the study of molecular-level architecture and drive hypotheses about modes of action, mechanisms, dynamics, and interactions with other molecules. Combining cryoelectron microscopy (cryo-EM) instrumentation with crystallographic techniques, MicroED has led to three-dimensional structural models of small molecules, peptides, and proteins and has generated tremendous interest due to its ability to use vanishingly small crystals. In this perspective, we describe the current state of the field for MicroED methodologies, including making and detecting crystals of the appropriate size for the technique, as well as ways to best handle and characterize these crystals. Our perspective provides insight into ways to unlock the full range of potential for MicroED to access previously intractable samples and describes areas of future development.

3D ED↗

The imaging Time-of-Propagation detector at Belle II

Here, we report on the construction, operation, and performance of the Time-of-Propagation detector with imaging used for the Belle II experiment running at the Super-KEKB e + e - collider. This detector is located in the central barrel region and uses Cherenkov light to provide particle identification among hadrons. The Cherenkov light is radiated in highly polished bars of synthetic fused silica (quartz) and transported to the ends of the bars via total internal reflection. One bar end is instrumented with finely segmented micro-channel-plate photomultiplier tubes to record the light, while the other end has a mirror attached to reflect the photons back to the instrumented end. Both the propagation times and hit positions of the Cherenkov photons are measured; these depend on the Cherenkov angle and together provide good discrimination among charged pions, kaons, and protons with momenta up to around 4 GeV/ c . To date, the detector has been used to record and analyze almost 600 fb −1 of Belle II data.

43 PARTICLE ACCELERATORS↗

Auger@TA: In-situ Cross-Calibration of the World's Largest Cosmic Ray Observatories

The Pierre Auger Observatory (Auger) and the Telescope Array (TA) are the world's two largest ultra-high-energy cosmic ray (UHECR) observatories. They operate in the Southern and Northern hemispheres, respectively, at similar latitudes but with distinct surface detector (SD) designs. A significant challenge in studying UHECR physics across the full sky is the apparent discrepancy in flux measurements between the two experiments. This discrepancy could arise from astrophysical differences and/or systematic effects related to their detector designs and sensitivities to extensive air shower components. To address this, the Auger@TA working group aims to cross-calibrate the two observatories with a self-triggering micro-Auger array within the TA array. This micro-array consists of eight Auger Surface Detector (SD) stations equipped with Water Cherenkov Detectors (WCDs) and AugerPrime Surface Scintillator Detectors. Seven SD stations, configured with a centered-1-PMT design, are arranged in a hexagonal pattern with one station in the center, with 1.5 km spacing, mirroring the Auger layout. The eighth station, which features a standard 3-PMT Auger station, is located in conjunction with a TA detector at the center of the hexagon, forming a triplet for high-statistics and low-uncertainty cross-calibration. A custom communication system that uses readily available components enables seamless communication between stations and remote access to each station through a central computer. The micro-array is now fully deployed, and initial data-taking is about to start. This presentation will detail the instrumentation, communication systems, central data acquisition system, expected performance of the micro-array, and preliminary results as appropriate.

Mocellin, Adriel G.B. [Colorado School of Mines]↗

Laminography as a tool for imaging large-size samples with high resolution

Despite the increased brilliance of the new generation synchrotron sources, there is still a challenge with high-resolution scanning of very thick and absorbing samples, such as a whole mouse brain stained with heavy elements, and, extending further, brains of primates. Samples are typically cut into smaller parts, to ensure a sufficient X-ray transmission, and scanned separately. Compared with the standard tomography setup where the sample would be cut into many pillars, the laminographic geometry operates with slab-shaped sections significantly reducing the number of sample parts to be prepared, the cutting damage and data stitching problems. In this work, a laminography pipeline for imaging large samples (>1 cm) at micrometre resolution is presented. The implementation includes a low-cost instrument setup installed at the 2-BM micro-CT beamline of the Advanced Photon Source. Additionally, sample mounting, scanning techniques, data stitching procedures, a fast reconstruction algorithm with low computational complexity, and accelerated reconstruction on multi-GPU systems for processing large-scale datasets are presented. The applicability of the whole laminography pipeline was demonstrated by imaging four sequential slabs throughout an entire mouse brain sample stained with osmium, in total generating approximately 12 TB of raw data for reconstruction.

47 OTHER INSTRUMENTATION↗

MARVEL Instrumentation, Control, and Software Considerations

This paper details the various I&C considerations and design decisions made throughout the MARVEL (Micro-reactor Applications Research Validation and Evaluation) project, including sensor and actuator selection, safety-related functionality, digital control hardware and software, and testing methodologies. Key challenges such as managing radiation, temperature, and space constraints are discussed, along with the trade-offs between using standard equipment and custom solutions. The successful integration of off-the-shelf components, the emphasis on minimizing safety-related instrumentation, and the lessons learned from prototyping and testing are highlighted. The authors aim to provide insights that can benefit future micro-reactor designs and emphasize the importance of real-world testing in advancing reactor technology.

46 - INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AN↗

Remote sensing of planetary boundary layer from ground and space: Structure, thermodynamics, and boundary layer clouds

The planetary boundary layer (PBL) is a critical interface between Earth's surface and atmosphere, influencing atmospheric convection, weather patterns, and air quality. Recognized by the 2017 National Academies of Sciences, Engineering, and Medicine Earth Science Decadal Survey as an Incubation Targeted Observable, high-quality and effective observation of the PBL has become a priority. This paper reviews surface-based and satellite remote sensing techniques for characterizing PBL features, including PBL height (PBLH), boundary layer thermodynamics, turbulence, and boundary layer clouds (BLCs). These elements are treated as interconnected aspects of the PBL system, while recognizing that different instruments retrieve different physical manifestations of the PBL. The review summarizes recent advances and limitations in Micro-Pulse Lidar (MPL), Doppler lidar, Raman lidar, Differential Absorption Lidar (DIAL), ceilometers, wind profilers, GNSS Radio Occultation, radar, and hyperspectral sounders. These observations help trace dynamic processes within the PBL and link PBL structure to broader weather and climate processes. The review also highlights persistent observational gaps over oceans, remote land, and polar regions, where continuous surface-based profiling is sparse. By comparing instrument capabilities, practical limitations, and interpretation issues, this review emphasizes the need for integrated remote sensing approaches and careful definition of the retrieved PBL quantities.

Boundary layer clouds↗

Verification of electromagnetic simulation capabilities in global gyrokinetic particle-in-cell code GTS

Recently, the numerical scheme presented by Mishchenko et al. enabled explicit gyrokinetic simulations of low-frequency electromagnetic instabilities in tokamaks at experimentally relevant values of plasma β⁠. This scheme resolved the long-standing cancellation problem that previously hindered gyrokinetic particle-in-cell code simulations of magnetohydrodynamic phenomena with inherently small parallel electric fields. Moreover, the scheme did not employ approximations that eliminate critical tearing-type instabilities. Here, we report on the implementation of this numerical scheme in the global gyrokinetic particle-in-cell code GTS. This implementation allows for a more complete and accurate picture of interaction between small scale turbulence and MHD modes in tokamaks. Additionally, we present a comprehensive set of verification simulations of numerous electromagnetic instabilities relevant to present-day tokamaks. These simulations encompass the kinetic ballooning mode, the internal kink mode, the tearing mode, the micro-tearing mode, and the toroidal Alfven eigenmode destabilized by energetic ions, which are all instrumental in understanding tokamak physics. We will also showcase the preliminary nonlinear simulations of kinetic ballooning instabilities and (2,1) island formation due to tearing mode instability. These simulations validate the accuracy of the scheme implementation and pave the way for studying how these instabilities affect plasma confinement and performance.

70 PLASMA PHYSICS AND FUSION TECHNOLOGY↗

The sPHENIX Micromegas Outer Tracker

The sPHENIX Time Projection Chamber Outer Tracker (TPOT) is a Micromegas based detector. It is a part of the sPHENIX experiment that aims to facilitate the calibration of the Time Projection Chamber, in particular the correction of the time-averaged and beam-induced distortions of the electron drift. Here, this paper describes the detector mission, setup, construction, installation, commissioning and performance during the first year of sPHENIX data taking.

47 OTHER INSTRUMENTATION↗

Moving toward automated µFTIR spectra matching for microplastic identification: addressing false identifications and improving accuracy

Abstract Infrared spectroscopy is a widely used tool for studying microplastics and identifying microparticles. Researchers rely on spectral libraries to differentiate between synthetic and natural materials. Unfortunately, spectral library matching is not perfect, and best practices require researchers to use time consuming, manual peak matching to assess spectral matches. Moving toward automated matching requires increased confidence in the matching process. Using spectra matching software may increase the efficiency of particle identification, however some matching strategies may confuse natural materials such as cotton, silk, and plant matter with common classes of synthetics such as polyesters and polyamides. In this experiment, we prepared 22 pristine sample materials from natural and synthetic sources and measured micro-Fourier transform infrared (µFTIR) spectra in transmission mode for each sample using a Thermo Nicolet iN10 MX instrument. The collected spectra were then input into two spectral library matching systems (Omnic Picta and Open Specy), using a total of five identification routines. Next, we placed a subset of four pristine microplastic materials in a biologically active river system for two weeks to simulate environmental samples. These simulated environmental samples were processed using 10% hydrogen peroxide for 24 h to remove organic contamination and then identified using the strongest performing library. We found that libraries with fewer sample spectra produced lower correlation matches and that using derivative correction greatly reduced the number of inaccuracies in identifying materials as either natural or synthetic. We also found that environmental fouling reduced the correlation value of library matches when compared to pristine particles, however the effect was not consistent across the four materials tested. Overall, we found that the accuracy of automated library matching in the tested systems and processing routines varied from 64.1 to 98.0% for distinguishing between natural and synthetic materials, and that a high Hit Quality Index (HQI) did not always correlate with accuracy. These results are important for the microplastic field, demonstrating a need to rigorously test spectral libraries and processing routines with known materials to ensure identification accuracy.

Kozloski, Rachel↗

Evaluation of methods for characterizing the fine particulate matter emissions from aircraft and other diffusion flame combustion aerosol sources

The U. S. Environmental Protection Agency in collaboration with the U. S. Air Force Arnold Engineering Development Complex conducted the VAriable Response In Aircraft nvPM Testing (VARIAnT) 3 and 4 test campaigns to compare nvPM emissions measurements from a variety of diffusion flame combustion aerosol sources (DFCASs), including a Cummins diesel engine, a diesel powered generator, two gas turbine start carts, a J85-GE-5 turbojet engine burning multiple fuels, and a Mini-CAST soot generator. The VARIAnT research program has conducted four test campaigns to date with the VARIAnT 3 and 4 test campaigns focusing on BC mass instrument performance, use of gas turbine engine sources for BC mass instrument calibration, and the characterization of the aerosols produced from the combustion sources. Results from both campaigns revealed agreement of about 20% between the AVL Micro-Soot Sensor, the Cavity Attenuated Phase Shift (CAPS PMSSA) monitor and the thermal-optical reference method for elemental carbon (EC), independent of the calibration source used. For the Artium LII-300, the measured mass concentrations in VARIAnT3 fall within 18% and in VARIAnT4 fall within 32% of the reference EC mass concentration when calibrated on a combustor rig in VARIAnT3 and on a LGT-60 start cart in VARIAnT4, respectively. It was also found that the three mass instrument types (MSS, CAPS PMSSA, and LII-300) can exhibit different BC to reference EC ratios depending on the emission source that appear to correlate to particle geometric mean mobility diameter, morphology, or some other parameter associated with particle geometric mean diameter (GMD) with the LII-300 showing a slightly stronger apparent trend with GMD. Systematic differences in LII-300 measured mass concentrations have been reduced by calibrating with a turbine combustion source (combustor or turbine engine). With respect to the particle size measurements made, the sizing instruments (TSI SMPS, TSI EEPS, and Cambustion DMS 500) were found to be in general agreement in terms of size distributions and concentrations with some exceptions. Teflon filter measurements of the total aerosol mass produced by the various DFCASs differed from the reference EC, BC, and integrated particle sized distribution measured aerosol masses. The Teflon filter measured mass was 30 to 40% greater than the reference EC and 50 to 60% greater than the BC mass for the J85 in both test campaigns. The measurements of particle size distributions and single particle analysis by miniSPLAT indicated the presence of large particles (>100 nm) having more compact morphologies, higher effective density, and a composition dominated by OC and ash. This increased large particle fraction is also associated with higher values of single scattering albedo measured by the CAPS PMSSA instrument and higher OC/EC measurements. These measurements indicate gas turbine engine emissions can be a more heterogeneous mix of particle types beyond the original E31 assumption that it is mainly composed of black carbon.

33 ADVANCED PROPULSION SYSTEMS↗

Studying Aerosol, Clouds, and Air Quality in the Coastal Urban Environment of Southeastern Texas

A multi-agency succession of field campaigns was conducted in southeastern Texas during July 2021 through October 2022 to study the complex interactions of aerosols, clouds and air pollution in the coastal urban environment. As part of the Tracking Aerosol Convection interactions Experiment (TRACER), the TRACER- Air Quality (TAQ) campaign the Experiment of Sea Breeze Convection, Aerosols, Precipitation and Environment (ESCAPE) and the Convective Cloud Urban Boundary Layer Experiment (CUBE), a combination of ground-based supersites and mobile laboratories, shipborne measurements and aircraft-based instrumentation were deployed. These diverse platforms collected high-resolution data to characterize the aerosol microphysics and chemistry, cloud and precipitation micro- and macro-physical properties, environmental thermodynamics and air quality-relevant constituents that are being used in follow-on analysis and modeling activities. We present the overall deployment setups, a summary of the campaign conditions and a sampling of early research results related to: (a) aerosol precursors in the urban environment, (b) influences of local meteorology on air pollution, (c) detailed observations of the sea breeze circulation, (d) retrieved supersaturation in convective updrafts, (e) characterizing the convective updraft lifecycle, (f) variability in lightning characteristics of convective storms and (g) urban influences on surface energy fluxes. The work concludes with discussion of future research activities highlighted by the TRACER model-intercomparison project to explore the representation of aerosol-convective interactions in high-resolution simulations.

54 ENVIRONMENTAL SCIENCES↗

A new active base of photomultiplier R4125 designed for the PbWO4 calorimeter

This paper presents the design, performance, and results of the radiation tests of an active base for Hamamatsu R4125 photomultiplier tube. The active base was designed at Jefferson Lab and comprises of a high voltage divider and an on-board amplifier. The photomultiplier with the active base is used to detect light from lead tungstate scintillating crystals of the forward electromagnetic calorimeter of the GlueX detector. The active base amplifier allows to operate the tube at lower high voltage and thus to limit the photomultiplier anode current to a few micro ampereres at the maximum counter rate of 1 MHz counter, while retaining the dynamic range of output signals. The performance of calorimeter modules instrumented with the active base was studied using detector prototypes positioned into the beam of photons. The key performance parameters such as the linearity, high-rate capability, and the energy resolution verified that the active base design meets the detector specifications

Somov, Alexander [Thomas Jefferson National Accele↗

Southern Ocean Aerosols Field Campaign Report

Atmospheric processes over the Southern Ocean have a profound influence on regional and global climate. This is a part of the world where global climate models perform particularly poorly, with models persistently overpredicting the amount of sunlight reaching the Earth's surface (Regayre et al. 2020). A major challenge when trying to improve the representation of atmospheric processes in this part of the globe is the scarcity of observations capable of constraining our understanding. During 2024/25 a U.S. Department of Energy Atmospheric Radiation Measurement (ARM) User Facility field campaign (CAPE-k) deployed a suite of instrumentation at the kennaook/Cape Grim atmospheric monitoring station in Tasmania, Australia to provide detailed cloud-aerosol observations in this region in order to address the greatest source of uncertainty in climate models – atmospheric aerosols and how they influence cloud formation (Carslaw et al. 2013). In support of the ARM observations, an Australian Research Council (ARC)-funded project “Southern Ocean aerosols: sources, sinks and impact on cloud properties,” led by the Queensland University of Technology, complemented the ARM measurements with a suite of chemical measurements at the kennaook/Cape Grim site in northwestern Tasmania to provide more information on the processes controlling aerosol formation and growth. The deployment of the University of York LIF-SO2 instrument (Temple et al. 2025) in the ARM mobile facility container was part of this chemistry-focused deployment. Increased observational efforts are critical for understanding sources and sinks of Southern Ocean aerosols, in particular the role of marine micro-organisms (phytoplankton, algae) on aerosols formation, their properties and growth, cloud droplet formation, and the conversion of cloud droplets to ice crystals and precipitation. The observational focus of the ARC-funded project is aerosol chemical composition and their gaseous precursors. The remote nature of the Southern Ocean poses a significant analytical challenge when studying gaseous precursors, as low concentrations are often below the limits of detection of commercial instrumentation. Historically this has meant that observations have had to be time-averaged over days to weeks to achieve the limits of detection required. Although useful when considering overall average levels of aerosol precursors, this time-averaging obscures temporal variability that can provide insight into the controlling processes. Over recent years advances in analytical techniques have made high-time-resolution measurements of key gas-phase aerosol precursors achievable with sufficiently low limits of detection.

54 ENVIRONMENTAL SCIENCES↗

Structural biology at the National Synchrotron Light Source II

The structural biology program at the National Synchrotron Light Source II presents a coordinated set of instruments, software and research opportunities for the interested user. We describe in some detail the research capabilities enabled by the Center for BioMolecular Structure. The evolution of the resources is described in detail, considering three major themes: automation, micro-focusing and computation prediction.

36 MATERIALS SCIENCE↗

Non-linear elastic-plastic behavior of the invert glass lithium phosphorous oxynitride (LiPON)

Micro and nano-scale mechanical behavior of network/ionic glasses is dictated by their composition and the number of constraints per structural unit. From this perspective, the glass LiPON presents the opportunity for enhancement of the microscale ductility due to its rather unconstrained orthophosphate structure. Here, we use instrumented nanoindentation with different tip geometries to investigate the mechanical response of LiPON glass. The results reveal that the elastic modulus of LiPON is not constant and depends on pressure. With the method utilizing spherical nanoindentation and continuous stiffness measurement (CSM) we determine the yield point of LiPON. We propose the Drucker-Prager type of yield criterion for LiPON and estimate its yield stress in compression as 2.4 GPa. There exists another stress threshold, however, around 490 MPa, at which the elastic deformation becomes non-linear, and this can be mistaken for the yield stress.

Constitutive model↗