SEARCH · Search NASA
Results for “micro-CHP”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Residential Home Decarbonization Using Advanced Micro-CHP
An efficient micro-combined heat and power (CHP) prototype was developed to provide heat and electricity for single-family homes and light commercial buildings. The unit can be installed independently at the point of energy consumption. Consequently, it enables cost-effectively and flexibly matching heat and electrical loads, simplifying distribution and installation processes, and recovering and storing waste heat as hot water. The analyzed results show that the micro-CHP using natural gas as fuel achieves 10.68%–32.80% CO2 reduction in the selected five home applications. The potential effect of H2 on decarbonization of these home was also evaluated, finding that the micro-CHP using a blended fuel with H2 and natural gas can further reduce CO2 emissions. However, the 50% CO2 reduction in the micro-CHP requires at least 70%–90% of H2 in the blend with natural gas. Overall, the micro-CHP technology demonstrates a solid potential to accelerate micro-CHP adoption in residential and light commercial markets, thereby promoting broader micro-CHP acceptance and use in the future for building decarbonization.
Development and testing of residential micro-CHP powered by opposed piston engine (CRADA Final Report)
A micro–combined heat and power (mCHP) prototype powered by innovative opposed piston engine technology was developed to simultaneously provide electricity and heat to residential or light commercial buildings. The mCHP prototype targeted at residential applications includes an opposed-piston four-stroke (OP4S) engine, generator, rectifier, inverter, battery energy storage system, 52 gal water tank, and application accessories for hot water supply and space heating. The OP4S engine can use renewable or regular natural gas, as well as hydrogen, to generate mechanical power and waste heat in form of hot coolant and exhaust gas simultaneously. The waste heat is recovered and stored in the water tank and can be used as a regular hot water supply and/or for space heating application. The tests show that the mCHP prototype enabled power outputs in the range of 3.2 –7.4 kW with up to 26.4% of AC electricity efficiency and up to 93.1% of the overall mCHP efficiency under stoichiometric combustion modes λ=~1.0. The mCHP was also run under lean combustion mode conditions at λ=~1.3. The lean mode operation enables more than 30% improvement in electrical energy efficiency. The maximum AC efficiency of the lean combustion mode attained was 35.2%, with the engine efficiency is approaching 40%. The exceptional electrical efficiency breaks the typical upper boundary of 30% for ICE-based mCHP. The engine exhaust temperatures in the lean modes are substantially less than in the stoichiometric modes. Moreover, the lean cases achieve high overall mCHP efficiencies: the overall mCHP efficiencies are all greater than 93%. Considering the mCHP prototype can achieve low-cost, flexible matching of thermal and electrical loads through reducing the complexity of distribution and installation, and high efficiency the novel technology will promote mCHP acceptance in the US residential and light commercial markets.
Advanced Micro Combined Heat and Power Device
U.S. buildings account for approximately 40% of total U.S. energy consumption and 75% of electricity use, emphasizing the need for efficient, resilient, and secure energy solutions. Micro-combined heat and power (micro-CHP) systems provide an effective approach by simultaneously generating electricity and recovering waste heat for thermal use. However, current commercial micro-CHPs face challenges in achieving higher efficiency, lower emissions, and reduced cost. To address these limitations, a novel micro-CHP prototype powered by a unique opposed-piston four-stroke (OP4S) engine was developed. The OP4S features a simplified, low-cost design with reduced heat losses and dual-piston operation that enables higher thermal efficiency. Experimental results demonstrated up to 35.2% AC electrical efficiency under lean combustion, surpassing the best-performing ICE-based micro-CHPs reported publicly. In addition, the micro-CHP enables a total CHP efficiency exceeding 93%. The prototype operates reliably for over 600 hours, providing flexible and efficient thermal and electrical outputs. This novel OP4S-based micro-CHP offers a resilient, low-cost, and energy-efficient solution suitable for residential, light commercial, and remote community applications across diverse climate zones.
High performance protonic ceramic fuel cell systems for distributed power generation
The technology landscape around distributed generation continues to evolve in response to increasing demand for high-efficiency, low-emission, low-cost power generation. While emerging distributed power technologies, such as solid oxide fuel cells (SOFCs), continue to advance, they still face challenges due to their high capital costs, and shorter lifetimes that typically arise from electrochemical stack performance degradation at high operating temperatures (>750 °C). Recent advancements in protonic ceramic fuel cells (PCFCs) offer the potential to mitigate drawbacks of their higher temperature SOFC counterparts by enabling lower operating temperatures (550 °C–600 °C) with acceptable power densities. Here the present work leverages the recent progress in protonic ceramic cell and stack technology development to generate viable system configurations and evaluate the energetic performance potential of PCFC-based systems for stationary power generation. Process system engineering of two water-neutral system concepts, which provide 25 kW of electric power and process hot water, are presented and evaluated through sensitivity studies. Stack design parameters are altered and used to gauge the effect on system performance characteristics, including fuel cell stack and balance-of-plant sizing requirements, and electric and cogeneration efficiencies. The study finds that the potentially high per-pass fuel utilization capability of PCFC stacks could enable unprecedented electric efficiencies approaching 70% without hybridization with other prime movers.