Search NASA⌕ Search

SEARCH · Search NASA

Results for “micro-XRF”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Sulphur variations in annually layered stalagmites using benchtop micro-XRF

Variation of sulphur in annually laminated stalagmites can be used to infer the impact of past volcanic activities, anthropogenic pollution, and climate change due to increased bushfire activity. The synchrotron radiation micro-X-Ray fluorescence (SR-XRF) microprobe is a powerful tool to analyse and image sulphur recorded in stalagmites with micrometre resolution. However, access to SR-XRF beamlines can be limited, so researchers must select the most promising stalagmites for imaging. Benchtop micro-XRF is an effective tool for trace elemental analysis of speleothem samples and is a candidate for routine laboratory measurement of sulphur along stalagmite laminae and screening for SR-XRF. Here, this study describes a protocol using matrix-matched standards to measure annual variations of sulphur at trace to percent level along the laminae of two Western Australian stalagmites, one of which already having been analysed using SR-XRF. Parameters that affected quantitation include X-ray tube voltage and current, spot size of the X-ray beam and stalagmite surface roughness and porosity. The use of a 20 μm X-ray spot size provides sub-annual spatial resolution that can be completed in an overnight scan. The features in a 1000 point micro-XRF analysis of sulphur along a 20 mm transect show good consistency with SR-XRF microprobe data. Micro-XRF mapping was also performed to produce chemical images on the stalagmite and compared with Raman and X-ray diffraction (XRD) to confirm that the stalagmite is exclusively calcite, with no aragonite, and that the source of sulphur in the samples was gypsum and anhydrite. Regions of very high sulphur in the micro-XRF maps were found to be artefacts due to diffraction of the incident beam but these could be efficiently removed by using a multiple point statistics approach to produce a clean image suitable for analysis of the laminae. This work shows the potential of micro-XRF for routine analysis of sulphur in stalagmites, and to streamline sample characterisation before SR-XRF imaging.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Identification of New Lithic Clasts in Lunar Breccia 14305 by Micro-CT and Micro-XRF Analysis

From 1969 to 1972, Apollo astronauts collected 382 kg of rocks, soils, and core samples from six locations on the surface of the Moon. The samples were initially characterized, largely by binocular examination, in a custom-built facility at Johnson Space Center (JSC), and the samples have been curated at JSC ever since. Despite over 40 years of study, demand for samples remains high (~500 subsamples per year are allocated to scientists around the world), particularly for plutonic (e.g., anorthosites, norites, etc.) and evolved (e.g., granites, KREEP basalts) lithologies. The reason for the prolonged interest is that as new scientists and new techniques examine the samples, our understanding of how the Moon, Earth, and other inner Solar System bodies formed and evolved continues to grow. Scientists continually clamor for new samples to test their emerging hypotheses. Although all of the large Apollo samples that are igneous rocks have been classified, many Apollo samples are complex polymict breccias that have previously yielded large (cm-sized) igneous clasts. In this work we present the initial efforts to use the non-destructive techniques of micro-computed tomography (micro-CT) and micro x-ray fluorescence (micro-XRF) to identify large lithic clasts in Apollo 14 polymict breccia sample 14305. The sample in this study is 14305,483, a 150 g slab of regolith breccia 14305 measuring 10x6x2 cm (Figure 1a). The sample was scanned at the University of Texas High-Resolution X-ray CT Facility on an Xradia MicroXCT scanner. Two adjacent overlapping volumes were acquired at 49.2 micrometer resolution and stitched together, resulting in 1766 slices. Each volume was acquired at 100 kV accelerating voltage and 98 mA beam current with a 1 mm CaF2 filter, with 2161 views gathered over 360deg at 3 seconds acquisition time per view. Micro-XRF analyses were done at Washington University in St. Louis, Missouri on an EDAX Orbis PC micro-XRF instrument. Multiple scans were made at 40 kV accelerating voltage, 800 mA beam current, 30 μm beam diameter, and a beam spacing of 30-120 micrometer. The micro-CT scan of 14305,483 (Figure 2) was able to identify several large lithic clasts (approx. 1 cm) within the interior of the slab. These clasts will be exposed by band-sawing or chipping of the slab, and their composition more fully characterized by subsequent micro-XRF analysis. In addition to lithic clasts, the micro-CT scans identified numerous mineral clasts, including many FeNi metal grains, as well as the prominent fractures within the slab. The micro-XRF analyses (Figure 1b,c) of the slab surfaces revealed the bulk chemical compositions (qualitative) of the different clast types observed. In particular, by looking at the ratios of major elements (e.g. Ca:Mg:Fe), differences among the many observed clast types are readily observed. Moreover, several clasts not apparent to the naked eye were revealed in the K:Al:Si ratio map. The scans are also able to identify small grains of Zr- and P-rich minerals (not shown), which could in turn yield important age dates for the samples.

Zeigler, Ryan A.↗

Nondestructive Analysis of Astromaterials by Micro-CT and Micro-XRF Analysis for PET Examination

An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of the PET is to characterize and classify returned samples and make this information available to the larger research community who then conduct more in-depth studies on the samples. The PET tries to minimize the impact their work has on the sample suite, which has in the past limited the PET work to largely visual, nonquantitative measurements (e.g., optical microscopy). More modern techniques can also be utilized by a PET to nondestructively characterize astromaterials in much more rigorous way. Here we discuss our recent investigations into the applications of micro-CT and micro-XRF analyses with Apollo samples and ANSMET meteorites and assess the usefulness of these techniques in future PET. Results: The application of micro computerized tomography (micro-CT) to astromaterials is not a new concept. The technique involves scanning samples with high-energy x-rays and constructing 3-dimensional images of the density of materials within the sample. The technique can routinely measure large samples (up to approx. 2700 cu cm) with a small individual voxel size (approx. 30 cu m), and has the sensitivity to distinguish the major rock forming minerals and identify clast populations within brecciated samples. We have recently run a test sample of a terrestrial breccia with a carbonate matrix and multiple igneous clast lithologies. The test results are promising and we will soon analyze a approx. 600 g piece of Apollo sample 14321 to map out the clast population within the sample. Benchtop micro x-ray fluorescence (micro-XRF) instruments can rapidly scan large areas (approx. 100 sq cm) with a small pixel size (approx. 25 microns) and measure the (semi) quantitative composition of largely unprepared surfaces for all elements between Be and U, often with sensitivity on the order of a approx. 100 ppm. Our recent testing of meteorite and Apollo samples on micro-XRF instruments has shown that they can easily detect small zircons and phosphates (approx. 10 m), distinguish different clast lithologies within breccias, and identify different lithologies within small rock fragments (2-4 mm soil Apollo soil fragments).

Zeigler, R. A.↗

Micro-XRF for In Situ Geological Exploration of Other Planets

In situ analysis of rock chemistry is a fundamental tool for exploration of planets. To meet this need, a high-spatial-resolution micro x-ray fluorescence (Micro-XRF) instrument was developed that is capable of determining the elemental composition of rocks (elements Na U) with 100 microns spatial resolution, thus providing insight to the composition of features as small as sand grains and individual laminae. The resulting excitation beam is of sufficient intensity that high signal-to-noise punctual spectra are acquired in seconds to a few minutes using an Amptek Silicon Drift Detector (SDD). The instrument features a tightly focused x-ray tube and HVPS developed by Moxtek that provides up to 200 micro-A at 10 to 50 keV, with a custom polycapillary optic developed by XOS Inc. and integrated into a breadboard Micro-XRF (see figure). The total mass of the complete breadboard instrument is 2.76 kg, including mounting hardware, mounting plate, camera, laser, etc. A flight version of this instrument would require less than 5W nominal power and 1.5 kg mass. The instrument includes an Amptek SDD that draws 2.5 W and has a resolution of 135 to 155 eV FWHM at 5.9 keV. It weighs 180 g, including the preamplifier, digital pulse processor, multichannel analyzer, detector and preamp power supplies, and packaging. Rock samples are positioned relative to the instrument by a three-axis arm whose position is controlled by closed-loop translators (mimicking the robotic arm of a rover). The distance from the source to the detector is calculated from the position of a focused laser beam on the sample as imaged by the camera. The instrument enables quick scans of major elements in only 1 second, and rapid acquisition (30 s) of data with excellent signal-to-noise and energy resolution for trace element analysis

Wade, Lawrence A.↗

Nondestructive Analysis of Apollo Samples by Micro-CT and Micro-XRF Analysis: A PET Style Examination

An integral part of any sample return mission is the initial description and classification of returned samples by the preliminary examination team (PET). The goal of a PET is to characterize and classify the returned samples, making this information available to the general research community who can then conduct more in-depth studies on the samples. A PET strives to minimize the impact their work has on the sample suite, which often limits the PET work to largely visual measurements and observations like optical microscopy. More modern techniques can also be utilized by future PET to nondestructively characterize astromaterials in a more rigorous way. Here we present our recent analyses of Apollo samples 14321 and 14305 by micro-CT and micro-XRF (respectively), assess the potential for discovery of "new" Apollo samples for scientific study, and evaluate the usefulness of these techniques in future PET efforts.

Zeigler, Ryan A.↗

Using micro-XRF to characterize chloride ingress through cold joints in 3D printed concrete

Digital fabrication methods with concrete have been rapidly developing, with many problems related to component production and material control being solved in recent years. These processes produce inherently layered cementitious components that are anisotropic, and in many cases, produces a weak interface between layers, which are generally referred to as cold joints. While material strength at these interfaces has been well studied in recent years, durability has received less attention, even though cold joints can function as channels for aggressive agents, such as chlorides. This work presents a method using micro-X-ray fluorescence (μXRF) to image chloride ingress into layer interfaces of 3D printed fine-grained concrete specimens produced with varying layer deposition time intervals, and also compares it to neutron imaging of moisture uptake. The results show that cold joints formed after a 1 day time interval are highly susceptible to chloride ingress, and that curing conditions play a major role in how quickly interfacial transport can take place. The μXRF method is also shown to be useful for study of transport of chlorides in cold joints, due to its spatial resolution and direct analysis of an aggressive species of interest.

36 MATERIALS SCIENCE↗

Micro-XRF : Elemental Analysis for In Situ Geology and Astrobiology Exploration

The ability to make close-up measurements of rock chemistry is one of the most fundamental tools for astrobiological exploration of Mars and other rocky bodies of the solar system. When conducting surface-based exploration, lithochemical measurements provide critical data that enable interpretation of the local geology, which in turn is vital for determining habitability and searching for evidence of life. The value of lithochemical measurements for geological interpretations has been repeatedly demonstrated with virtually every landed Mars mission over the past four decades.

Mars↗

The evolution of soil microstructure and micromineralogy along a soil age gradient on the Galápagos Islands (Ecuador)

The islands of the Galápagos archipelago are of different ages due to the combination of a geostationary volcanic hotspot and the eastward movement of the Nazca tectonic plate. Taking advantage of this, a soil chronosequence (1.5–1070 ka) has recently been established covering four of the islands. This was used to investigate the temporal development of soil microstructure and micromineralogy using micromorphological methods in combination with synchrotron-based mineralogical and geochemical microanalyses. Along the chronosequence, the microstructure changed from intergrain microaggregates in the young soils to angular blocky microaggregates in the older soils. In the young soils, a high amount of vitric scoria and weatherable minerals occur, but they quickly disappear with age, and micromass increased fast. The micromorphological studies as well as micro-XRD and micro-XRF revealed increasing heterogeneity of soil microstructure and micromineralogy due to weathering and pedogenic processes until intermediate soil age. In the oldest soils, the microstructure became more uniform again, de-mixing pedofeatures like clay coatings have completely disappeared, and kaolinite, hematite and gibbsite dominate the mineralogical composition. Our study shows that the development of soil microstructure mirrors macroscopic soil profile development showing increasing differentiation until intermediate developmental stages and receding heterogeneity in highly weathered soils.

54 ENVIRONMENTAL SCIENCES↗

Full Field X-Ray Fluorescence Imaging Using Micro Pore Optics for Planetary Surface Exploration

Many planetary surface processes leave evidence as small features in the sub-millimetre scale. Current planetary X-ray fluorescence spectrometers lack the spatial resolution to analyse such small features as they only provide global analyses of areas greater than 100 mm(exp 2). A micro-XRF spectrometer will be deployed on the NASA Mars 2020 rover to analyse spots as small as 120m. When using its line-scanning capacity combined to perpendicular scanning by the rover arm, elemental maps can be generated. We present a new instrument that provides full-field XRF imaging, alleviating the need for precise positioning and scanning mechanisms. The Mapping X-ray Fluorescence Spectrometer - "Map-X" - will allow elemental imaging with approximately 100μm spatial resolution and simultaneously provide elemental chemistry at the scale where many relict physical, chemical and biological features can be imaged in ancient rocks. The arm-mounted Map-X instrument is placed directly on the surface of an object and held in a fixed position during measurements. A 25x25 mm(exp 2) surface area is uniformly illuminated with X-rays or alpha-particles and gamma-rays. A novel Micro Pore Optic focusses a fraction of the emitted X-ray fluorescence onto a CCD operated at a few frames per second. On board processing allows measuring the energy and coordinates of each X-ray photon collected. Large sets of frames are reduced into 2d histograms used to compute higher level data products such as elemental maps and XRF spectra from selected regions of interest. XRF spectra are processed on the ground to further determine quantitative elemental compositions. The instrument development will be presented with an emphasis on the characterization and modelling of the X-ray focussing Micro Pore Optic. An outlook on possible alternative XRF imaging applications will be discussed.

micro-XRF spectrometer↗

Recent Advances in Nuclear Forensic Chemistry

Nuclear forensics is a rapidly growing field with a widespread impact on global nonproliferation. From the beginning, nuclear forensic capabilities have been inextricably bound to existing limitations within chemistry and materials science. As nuclear forensics has continued to develop as a unique field of research, new advances in chemistry have revolutionized our ability to rapidly and quantitatively analyze radioactive materials for attribution. In particular, microanalytical techniques originally developed for nanoscience, such as micro-XRF, SIMS, and SEM-EDX, have enabled spatially resolved chemical analyses to be performed with only nanograms of material. Such techniques have redefined the paradigm for pre- and postdetonation nuclear forensics, as large quantities of material are no longer necessary for full characterization and attribution. This Review explains how modern nuclear forensic techniques have developed from their origins in chemistry and provides real-world examples of how these techniques have been used to characterize radioactive materials, including fallout from nuclear detonations such as the 1945 Trinity test.

38 RADIATION CHEMISTRY, RADIOCHEMISTRY, AND NUCLEA↗

NASA Tech Briefs, July 2013

Dielectrophoresis-Based Particle Sensor Using Nanoelectrode Arrays; Multi-Dimensional Damage Detection for Surfaces and Structures; ULTRA: Underwater Localization for Transit and Reconnaissance Autonomy; Autonomous Cryogenic Leak Detector for Improving Launch Site Operations; Submillimeter Planetary Atmospheric Chemistry Exploration Sounder; Method for Reduction of Silver Biocide Plating on Metal Surfaces; Silicon Micromachined Microlens Array for THz Antennas; Forward-Looking IED Detector Ground Penetrating Radar; Fully Printed, Flexible, Phased Array Antenna for Lunar Surface Communication, Battery Charge Equalizer with Transformer Array; An Efficient, Highly Flexible Multi-Channel Digital Downconverter Architecture; Dimmable Electronic Ballast for a Gas Discharge Lamp; Conductive Carbon Nanotube Inks for Use with Desktop Inkjet Printing Technology; Enhanced Schapery Theory Software Development for Modeling Failure of Fiber-Reinforced Laminates; High-Performance, Low-Temperature-Operating, Long-Lifetime Aerospace Lubricants; Carbon Nanotube Microarrays Grown on Nanoflake Substrates; Differential Muon Tomography to Continuously Monitor Changes in the Composition of Subsurface Fluids; Microgravity Drill and Anchor System; 20 Granular Media-Based Tunable Passive Vibration Suppressor; 21 Miga Aero Actuator and 2D Machined Mechanical Binary Latch; Micro-XRF for In Situ Geological Exploration of Other Planets; Hydrogen-Enhanced Lunar Oxygen Extraction and Storage Using Only Solar Power; Uplift of Ionospheric Oxygen Ions During Extreme Magnetic Storms; Miniaturized, High-Speed, Modulated X-Ray Source; Hollow-Fiber Spacesuit Water Membrane Evaporator 25 High-Power Single-Mode 2.65-micrometers InGaAsSb/AlInGaAsSb Diode Lasers; Optical Device for Converting a Laser Beam Into Two Co-aligned but Oppositely Directed Beams; A Hybrid Fiber/Solid-State Regenerative Amplifier with Tunable Pulse Widths for Satellite Laser Ranging; X-Ray Diffractive Optics; SynGenics Optimization System (SynOptSys); 29 CFD Script for Rapid TPS Damage Assessment; radEq Add-On Module for CFD Solver Loci-CHEM; Science Opportunity Analyzer (SOA) Version 8; 30 Autonomous Byte Stream Randomizer; Distributed Engine Control Empirical/Analytical Verification Tools; Dynamic Server-Based KML Code Generator Method for Level-of-Detail Traversal of Geospatial Data; Automated Planning of Science Products Based on Nadir Overflights and Alerts for Onboard and Ground Processing; Linked Autonomous Interplanetary Satellite Orbit Navigation; Risk-Constrained Dynamic Programming for Optimal Mars Entry, Descent, and Landing; Scheduling Operations for Massive Heterogeneous Clusters; Deepak Condenser Model (DeCoM); Flight Software Math Library; Recirculating 1-K-Pot for Pulse-Tube Cryostats; 35 Method for Processing Lunar Regolith Using Microwaves; Wells for In Situ Extraction of Volatiles from Regolith (WIEVR); and Estimating the Backup Reaction Wheel Orientation Using Reaction Wheel Spin Rates Flight Telemetry from a Spacecraft.

Source record↗

The Astromaterials X-Ray Computed Tomography Laboratory at Johnson Space Center

The Astromaterials Acquisition and Curation Office at NASA's Johnson Space Center (hereafter JSC curation) is the past, present, and future home of all of NASA's astromaterials sample collections. JSC curation currently houses all or part of nine different sample collections: (1) Apollo samples (1969), (2) Lunar samples (1972), (3) Antarctic meteorites (1976), (4) Cosmic Dust particles (1981), (5) Microparticle Impact Collection (1985), (6) Genesis solar wind atoms (2004); (7) Stardust comet Wild-2 particles (2006), (8) Stardust interstellar particles (2006), and (9) Hayabusa asteroid Itokawa particles (2010). Each sample collection is housed in a dedicated clean room, or suite of clean rooms, that is tailored to the requirements of that sample collection. Our primary goals are to maintain the long-term integrity of the samples and ensure that the samples are distributed for scientific study in a fair, timely, and responsible manner, thus maximizing the return on each sample. Part of the curation process is planning for the future, and we also perform fundamental research in advanced curation initiatives. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of sample collections, or getting new results from existing sample collections [2]. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, and curation of organically- and biologically-sensitive samples. As part of these advanced curation efforts we are augmenting our analytical facilities as well. A micro X-Ray computed tomography (micro-XCT) laboratory dedicated to the study of astromaterials will be coming online this spring within the JSC Curation office, and we plan to add additional facilities that will enable nondestructive (or minimally-destructive) analyses of astromaterials in the near future (micro-XRF, confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions; (2) be utilized by PET for future sample return missions; (3) be used for retroactive PET (Positron Emission Tomography)-style analyses of our existing collections; and (4) for periodic assessments of the existing sample collections. Here we describe the new micro-XCT system, as well as some of the ongoing or anticipated applications of the instrument.

Zeigler, R. A.↗

The Astromaterials X-Ray Computed Tomography Laboratory at Johnson Space Center

The Astromaterials Acquisition and Curation Office at NASA's Johnson Space Center (hereafter JSC curation) is the past, present, and future home of all of NASA's astromaterials sample collections. JSC curation currently houses all or part of nine different sample collections: (1) Apollo samples (1969), (2) Lunar samples (1972), (3) Antarctic meteorites (1976), (4) Cosmic Dust particles (1981), (5) Microparticle Impact Collection (1985), (6) Genesis solar wind atoms (2004); (7) Stardust comet Wild-2 particles (2006), (8) Stardust interstellar particles (2006), and (9) Hayabusa asteroid Itokawa particles (2010). Each sample collection is housed in a dedicated clean room, or suite of clean rooms, that is tailored to the requirements of that sample collection. Our primary goals are to maintain the long-term integrity of the samples and ensure that the samples are distributed for scientific study in a fair, timely, and responsible manner, thus maximizing the return on each sample. Part of the curation process is planning for the future, and we also perform fundamental research in advanced curation initiatives. Advanced Curation is tasked with developing procedures, technology, and data sets necessary for curating new types of sample collections, or getting new results from existing sample collections [2]. We are (and have been) planning for future curation, including cold curation, extended curation of ices and volatiles, curation of samples with special chemical considerations such as perchlorate-rich samples, and curation of organically- and biologically-sensitive samples. As part of these advanced curation efforts we are augmenting our analytical facilities as well. A micro X-Ray computed tomography (micro-XCT) laboratory dedicated to the study of astromaterials will be coming online this spring within the JSC Curation office, and we plan to add additional facilities that will enable nondestructive (or minimally-destructive) analyses of astromaterials in the near future (micro-XRF, confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions; (2) be utilized by PET for future sample return missions; (3) be used for retroactive PET (Positron Emission Tomography)-style analyses of our existing collections; and (4) for periodic assessments of the existing sample collections. Here we describe the new micro-XCT system, as well as some of the ongoing or anticipated applications of the instrument.

Zeigler, R. A.↗

Curating NASA's Past, Present, and Future Extraterrestrial Sample Collections

As codified in NASA Policy Directive 7100.10F, the Astromaterials Acquisition and Curation Office at NASA Johnson Space Center (hereafter JSC Curation) is charged with curation of all extraterrestrial material under NASA control, including future NASA missions. JSC Curation curates all or part of nine astromaterial collections in seven clean room suites: (1) Apollo Samples (1969; ISO 6-7), (2) Luna Samples (from USSR; 1972; ISO 7), (3) Antarctic Meteorites (1976; ISO 7), (4) Cosmic Dust (1981; ISO 5), (5) Microparticle Impact Collection (formerly called Space Exposed Hardware; 1985; ISO 5), (6) Genesis Solar Wind Atoms (2004; ISO 4); (7) Stardust Comet Particles (2006; ISO 5), (8) Stardust Interstellar Particles (2006; ISO 5), (9) Hayabusa Asteroid Particles (from JAXA; 2010; ISO 5). In addition to the labs that house the samples, we have installed and maintained a wide variety of facilities and infrastructure required to support the clean-rooms: more than 10 different HEPA-filtered air-handling systems, ultrapure dry gaseous nitrogen systems, an ultrapure water system (UPW) and cleaning facilities to provide clean tools and equipment for the labs. We also have sample preparation facilities for making thin sections, microtome sections, and even focused ion-beam (FIB) sections to meet the research requirements of scientists. To ensure that we are keeping the samples as pristine as possible, we routinely monitor the cleanliness of our clean rooms and infrastructure systems. This monitoring includes: daily monitoring of the quality of our UPW, weekly airborne particle counts in the labs, monthly monitoring of the stable isotope composition of the gaseous N2 system, and annual measurements of inorganic or organic contamination in processing cabinets. We track within our databases the current and ever-changing characteristics of more than 250,000 individual samples across our various collections (including the 19,141 samples on loan to 433 Principal Investigators in 24 countries). The next sample return missions that NASA will participate in are Hayabusa2 and OSIRIS-REx (Origins Spectral Interpretation Resource Identification Security - Regolith Explorer). The designs for a new state-of-the-art suite of clean rooms to house these samples at JSC have been finalized. This includes separate ISO class 5 clean rooms to house each collection, a common ISO class 7 area for general use, an ISO class 7 microtome laboratory, and a separate thin section lab. Additionally, a new cleaning facility is being designed and procedures developed that will allow for enhanced cleaning of cabinets and tools in an inorganically, organically, and biologically clean manner. We are also designing a large multi-purpose Advanced Curation laboratory that will allow us to develop the techniques necessary to fully support the Hayabusa2 and OSIRIS-REx missions, as well as future possible sample return missions (e.g., Lunar Polar Volatiles, Mars, Comet Surface). A micro-CT (micro Computed Tomography) laboratory dedicated to the study of astromaterials has come online within JSC Curation, and we plan to add additional facilities that will enable non-destructive (or minimally-destructive) analyses of astromaterials in the near future (e.g., micro-XRF (micro X-Ray Fluorescence), confocal imaging Raman Spectroscopy). These facilities will be available to: (1) develop sample handling and storage techniques for future sample return missions, (2) be utilized by PET (Positron Emission Tomography) for future sample return missions, (3) for retroactive PET-style analyses of our existing collections, and (4) for periodic assessments of the existing sample collections.

Zeigler, Ryan A.↗

Distribution of Mn Oxidation States in Grassland Soils and Their Relationships with Soil Pores

Manganese (Mn) is known to be an active contributor to processing and cycling of soil organic carbon (C), yet the exact mechanisms behind its interactions with C are poorly understood. Plant diversity in terrestrial ecosystems drives feedback links between plant C inputs and soil pores, where the latter, in turn, impact the redox environment and Mn. This study examined associations between soil pores (>36 μm Ø) and Mn within intact soils from two grassland ecosystems, after their >6-year implementation in a replicated field experiment. In this work, we used μ-XRF imaging and XANES spectroscopy to explore spatial distribution patterns of Mn oxidation states, combined with X-ray computed microtomography and 2D zymography. A high plant diversity system (restored prairie) increased soil C and modified spatial distribution patterns of soil pores as compared to a single species system (monoculture switchgrass). In switchgrass, the abundance of oxidized and reduced Mn oxidation states varied with distance from pores consistently with anticipated O 2 diffusion, while in the soil from restored prairie, the spatial patterns suggested that biological activity played a greater role in influencing Mn distributions. Based on the findings, we propose a hypothesis that Mn transformations promote C gains in soils of high plant diversity grasslands.

54 ENVIRONMENTAL SCIENCES↗

Chemical state mapping of simulant Chernobyl lava-like fuel containing material using micro-focused synchrotron X-ray spectroscopy

Uranium speciation and redox behaviour is of critical importance in the nuclear fuel cycle. X-ray absorption near-edge spectroscopy (XANES) is commonly used to probe the oxidation state and speciation of uranium, and other elements, at the macroscopic and microscopic scale, within nuclear materials. Two-dimensional (2D) speciation maps, derived from microfocus X-ray fluorescence and XANES data, provide essential information on the spatial variation and gradients of the oxidation state of redox active elements such as uranium. In the present work, we elaborate and evaluate approaches to the construction of 2D speciation maps, in an effort to maximize sensitivity to the U oxidation state at the U L 3 -edge, applied to a suite of synthetic Chernobyl lava specimens. Our analysis shows that calibration of speciation maps can be improved by determination of the normalized X-ray absorption at excitation energies selected to maximize oxidation state contrast. The maps are calibrated to the normalized absorption of U L 3 XANES spectra of relevant reference compounds, modelled using a combination of arctangent and pseudo-Voigt functions (to represent the photoelectric absorption and multiple-scattering contributions). We validate this approach by microfocus X-ray diffraction and XANES analysis of points of interest, which afford average U oxidation states in excellent agreement with those estimated from the chemical state maps. This simple and easy-to-implement approach is general and transferrable, and will assist in the future analysis of real lava-like fuel-containing materials to understand their environmental degradation, which is a source of radioactive dust production within the Chernobyl shelter.

36 MATERIALS SCIENCE↗

Major to trace element imaging and analysis of iron age glasses using stage scanning in the analytical dual beam microscope (tandem)

Dark and clear silicate glasses formed during an iron age vitrification event ≈ 1500 years ago at the Broborg hillfort near Uppsala, Sweden have been analyzed using a scanning electron microscope equipped with a micro-X-ray fluorescence (μXRF) spectrometer. Correlated µXRF and electron beam-induced energy dispersive spectrometry (EDS) X-ray maps were collected via stage-scanning at constant velocity. This coupled procedure represents a new approach for the cultural heritage community to conduct analytical studies of archaeometric specimens composed of metal, ceramic, or mixed inorganic/organic materials, where major and trace element compositions are registered in space for areas up to the centimeter-length scale at micrometer-scale resolution. Overview images were used to select areas for EDS beam scan maps correlated with multispectral cathodoluminescence (CL) imaging and co-located quantitative EDS and μXRF point analysis. Fe, Ca, Mg, Ti, P, Mn, Zr, Zn, and Y are enriched in the dark glass, while Si, Al, K, Na, Ba, Sr, Rb, and Ga are enriched in the clear glass. Unmelted material is comprised predominately of quartz (SiO 2 ) along with trace apatite (Ca 5 (PO 4 ) 3 [Cl,OH]) and zircon (ZrSiO 4 ). Multivariate statistical analysis was used to measure the area fractions of high variance components while lower variance components represented phase mixtures. Differences between calculated melt viscosities for the glass compositions are consistent with field and laboratory observations. Coupled large area EDS and μXRF imaging shows significant promise for informed selection of higher spatial resolution and higher sensitivity follow-up studies, e.g., those performed using synchrotron analysis.

36 MATERIALS SCIENCE↗