Search NASA⌕ Search

SEARCH · Search NASA

Results for “micro-computed tomography (micro-CT)”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Contact Angle Measurements Using Sessile Drop and Micro-CT Data from Six Sandstones

Numerous sessile drop and micro-computed tomography (micro-CT) studies have been conducted to quantify Geologic Carbon Storage formation wettability by measuring static contact angles (θ); however, the influence of pore geometry remains unknown. In this work, six sandstones (Bandera Brown, Berea, Bentheimer, Mt. Simon, Navajo, and Nugget) are used to measure θ using the two aforementioned experimental methods at identical testing conditions (45°C and 12.41 MPa). The range of θ measured at in situ conditions (micro-CT) exceeds those the range at ex situ (sessile drop method) conditions for all sandstones. However, when droplets with more representative in situ diameters are analyzed, θ averages show ex situ θ exceed those of in situ θ. Pore geometry does influence local θ, but the size of ex situ droplets relative to pore size appears to influence θ. This is an important to consider for future sessile drop studies used for analysis of CO 2 behavior in carbon storage reservoirs.

36 MATERIALS SCIENCE↗

The role of the spatial heterogeneity and correlation length of surface wettability on two-phase flow in a CO 2 -water-rock system

This study characterized and modeled heterogeneous surface wettability in sandstone and investigated the role of spatial heterogeneity and correlation length of surface wettability on relative permeability in a supercritical CO 2 (scCO 2 )-brine-rock system. Understanding the role of wettability heterogeneity on relative permeability is essential to geological CO 2 sequestration, oil and gas recovery, and contaminated groundwater remediation. Although numerous studies have attempted to understand the influences of surface wettability, capillary number (Ca), and viscosity ratio, the role of the spatial variation and correlation length of surface wettability on two-phase flow in three-dimensional (3D) porous media has not been unraveled due to the challenges in the measurement and representation of realistic rock surface wettability. In this work, we conducted in-situ measurements of surface contact angle (CA) in a Bentheimer sandstone after CO 2 flooding using micro-computed tomography (micro-CT), and found that the pore-scale CA distribution on rock surfaces followed a log-normal distribution associated with a spatial correlation length. Based on the statistical information from CT scanning, a Gaussian random field was used to model CA distributions that had desired standard deviations and spatial correlation lengths, which were then adjusted within a certain range of values for sensitivity analyses to study their combined effects on the two-phase flow in the porous medium using the lattice Boltzmann (LB) method. The LB two-phase flow simulation was accelerated using hybrid, multicore parallel computing to overcome the challenges in simulating multiphase flow in a large 3D domain having 800 × 800 × 600 nodes. The simulation results showed that the surface wettability heterogeneity (i.e., standard deviation of CA) had a lesser effect on the relative permeability of the wetting fluid (water) but a more significant impact on the relative permeability of the non-wetting fluid (scCO 2 ). The Corey model was used to fit the LB-simulated relative permeability curves of water and scCO 2 and showed that the variations in the relative permeability curves for both water and scCO 2 increased as the standard deviation and spatial correlation length of CA increased. This study illustrated that the assumption of homogeneous surface wettability may cause errors in multiphase flow simulations. Furthermore, the impacts of both the standard deviation and spatial correlation length of CAs should be accounted for. This is the first study that explored the spatial correlation lengths associated with CA distributions on sandstone surfaces and comprehensively investigated the roles of both spatial variation and correlation length of CA on two-phase flow properties in 3D porous media. The optimized LB multiphase flow model was proved a powerful tool to study the interplays and combined effects of these statistical parameters, which had critical applications in numerous natural and engineering processes that involved multiphase flow in porous media.

58 GEOSCIENCES↗

Multi-scale imaging of high-pressure hydrogen induced damage in EPDM rubber using X-ray microcomputed tomography, helium-ion microscopy and transmission electron microscopy

Ethylene propylene diene (EPDM) rubber has gained increasing interest for use in hydrogen infrastructure due to its excellent sealing performance and low temperature properties. However, severe structural damage has been observed in EPDM O-rings after exposure to high-pressure hydrogen. The origination and propagation mechanisms of this damage are poorly understood. Here, to address this knowledge gap, multi-scale imaging leveraging X-ray micro-computed tomography (micro-CT), helium ion microscopy (HeIM), and transmission electron microscopy (TEM) were used in this work to study a series of sulfur-cured ethylene propylene diene (EPDM) rubber materials with varying additives that were exposed to different hydrogen environments. Micro-CT captured the substantial structural damage due to hydrogen exposure; it revealed an association between zinc oxide (ZnO) particles and damage initiation. Further studies by TEM and scanning TEM with energy dispersive X-ray spectroscopy (EDS) were focused on these particles at the micro-to nano-scale range. TEM indicated that hydrogen causes void formation at the interface between ZnO and the rubber matrix. HeIM enabled imaging of surface morphology of the material at high resolution pre- and post-hydrogen exposure while providing information on chemical composition and that cannot be captured by either micro-CT or TEM.

08 HYDROGEN↗

Through-thickness fracture behavior of neutron-irradiated nuclear graphite NBG-17 Using X-ray micro-CT

Achieving precise control over crack propagation in nuclear graphite and conducting quantitative analysis remain challenging. In this study, the through-thickness fracture behavior of pristine and neutron-irradiated (700 °C, ∼7 dpa) NBG-17 nuclear graphite was investigated using split-disc testing coupled with micro-computed tomography (micro-CT). A notably lower number of micropores was observed in the neutron-irradiated specimen. The fracture toughness of neutron-irradiated NBG-17 was measured to be 1.45 MPa√m, compared to 1.17 ± 0.05 MPa√m for the pristine specimen. In both materials, cracks were found to initiate at the filler–binder interface, and often correlated with microstructural features such as pores and thermal cracks. Crack bridging and deflections emerged as the primary toughening mechanisms in both unirradiated and irradiated NBG-17. However, compared with the pristine specimen, the cracks in the neutron-irradiated specimen were more likely to grow trans granularly, resulting in less deflected crack paths. The reduced micro-porosity and strengthened filler–binder boundaries were considered to be the cause of the observed differences in crack morphologies. In conclusion, this study provides a qualitative analysis of the fracture behavior of neutron-irradiated nuclear graphite in the absence of radiolytic oxidation.

36 - MATERIALS SCIENCE↗

3D pore structure reconstruction of fluff region in top of EBR-II irradiated fuel by X-ray micro-computed tomography

Metallic fuels comprised of U-Zr binary and U-Pu-Zr ternary alloys are a promising fuel candidate for sodium-cooled fast reactors and possess many advantages over ceramic fuels such as higher uranium density and improved thermal conductivity. Fluff is a highly porous structure forming at the top of metallic fuel slugs during irradiation and was extensively observed in past sodium-cooled fast reactor (SFR) experiments such as Idaho National Laboratory’s Experimental Breeder Reactor II (EBR-II). Previous investigations have shown that fluff is rich in fissile atoms and hence could have neutronics implications, but its formation mechanisms are not understood. In this work, two cube-shaped lift outs were taken from the fluff and bulk fuel regions of a high burnup U-19Pu-10Zr composition EBR-II fuel slug and characterized by micro computed tomography (Micro-CT) and energy dispersive x-ray spectroscopy (EDS). This was used to characterize differences in microscale porosity and composition between fluff and bulk fuel, and to support or oppose postulated fluff formation mechanisms. Surface EDS showed minimal differences between the elemental compositions of the fluff and fuel cubes. However, three-dimensional (3D) pore analysis from the tomography scans showed significant differences between the fluff and fuel cube pore size distributions at the microscale level. The high porosity and irregular pore distribution seen in macroscale fluff was also present within the micro-scale fluff cube, having a much higher porosity than the fuel cube which was concentrated in a few large pore networks. In conclusion, these results indicate support for a creep driven mechanism of fluff formation.

11 - NUCLEAR FUEL CYCLE AND FUEL MATERIALS↗

Machine learning-assisted upscaling analysis of reservoir rock core properties based on micro-computed tomography imagery

Optimum solutions for geologic modeling and reservoir simulation in industries such as oil and gas recovery and carbon capture and storage require accurate characterization of reservoir properties, which are often heterogeneous. In this study, high-quality micro-computed tomography (CT) images (1.475-μm/pixel resolution) of a sandstone core acquired from the Bell Creek oil field, USA, were used to provide nondestructive analysis of pore- and core-scale heterogeneity across measurement scales of 94–566 μm. In addition to characterizing the as-received sample, the core sample was flooded with brine to evaluate the capacity of the core sample to receive injected fluids. The micro-CT images were systematically segmented into pore spaces and grains via machine learning (ML) steps including image preprocessing, label creation using a traditional ML method based on limited manual image annotation, and finally U-Net segmentation. The segmented image stacks were reconstructed into digital cubes of various scales of voxel lengths. The 3D porosity values were calculated for all the digital cubes, and the fractal dimensions of the cubes were estimated using a box-counting method. The results showed that smaller cubes had greater heterogeneity and that the porosity values could be accurately estimated by fractal dimension and voxel lengths using ML models. For the core sample with brine flooding, the ratio of pores filled by brine to the total pore space was related to the porosity and could also be accurately estimated by porosity, fractal dimension, and voxel lengths using ML models. In conclusion, the results of this study demonstrate that the concept of fractal dimension can be a useful vector to perform upscaling analysis of sandstone rock heterogeneity from the pore to core scale and that fractal dimensions can be used to estimate porosity values and pore space-filling capacity across those scales.

58 GEOSCIENCES↗

A wide-field micro-computed tomography detector: micron resolution at half-centimetre scale

Ideal three-dimensional imaging of complex samples made up of micron-scale structures extending over mm to cm, such as biological tissues, requires both wide field of view and high resolution. For existing optics and detectors used for micro-CT (computed tomography) imaging, sub-micron pixel resolution can only be achieved for fields of view of <2 mm. This article presents a unique detector system with a 6 mm field-of-view image circle and 0.5 µm pixel size that can be used in micro-CT units utilizing both synchrotron and commercial X-ray sources. A resolution-test pattern with linear microstructures and whole adult Daphnia magna were imaged at beamline 8.3.2 of the Berkeley Advanced Light Source. Volumes of 10000 × 10000 × 7096 isotropic 0.5 µm voxels were reconstructed over a 5.0 mm × 3.5 mm field of view. Measurements in the projection domain confirmed a 0.90 µm measured spatial resolution that is largely Nyquist-limited. This unprecedented combination of field of view and resolution dramatically reduces the need for sectional scans and computational stitching for large samples, ultimately offering the means to elucidate changes in tissue and cellular morphology in the context of larger, whole, intact model organisms and specimens. This system is also anticipated to benefit micro-CT imaging in materials science, microelectronics, agricultural science and biomedical engineering.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Enhancing synchrotron radiation micro-CT images using deep learning: an application of Noise2Inverse on bone imaging

In bone-imaging research, in situ synchrotron radiation micro-computed tomography (SRµCT) mechanical tests are used to investigate the mechanical properties of bone in relation to its microstructure. Low-dose computed tomography (CT) is used to preserve bone's mechanical properties from radiation damage, though it increases noise. To reduce this noise, the self-supervised deep learning method Noise2Inverse was used on low-dose SRµCT images where segmentation using traditional thresholding techniques was not possible. Simulated-dose datasets were created by sampling projection data at full, one-half, one-third, one-fourth and one-sixth frequencies of an in situ SRµCT mechanical test. After convolutional neural networks were trained, Noise2Inverse performance on all dose simulations was assessed visually and by analyzing bone microstructural features. Visually, high image quality was recovered for each simulated dose. Lacunae volume, lacunae aspect ratio and mineralization distributions shifted slightly in full, one-half and one-third dose network results, but were distorted in one-fourth and one-sixth dose network results. Following this, new models were trained using a larger dataset to determine differences between full dose and one-third dose simulations. Significant changes were found for all parameters of bone microstructure, indicating that a separate validation scan may be necessary to apply this technique for microstructure quantification. Noise present during data acquisition from the testing setup was determined to be the primary source of concern for Noise2Inverse viability. While these limitations exist, incorporating dose calculations and optimal imaging parameters enables self-supervised deep learning methods such as Noise2Inverse to be integrated into existing experiments to decrease radiation dose.

Obata, Yoshihiro (ORCID:0000000303659129)↗

Mt. Simon Sandstone - High Resolution CT

High resolution micro-computed tomography images of sandstone from the Mt. Simon formation at different depths. These images provide an insight into the pore structure of the Mt. Simon sandstone (e.g. for potential CO2 storage). This data set can be used to further study the formation as a whole..

CCS,CO2 Sequestration,Carbon Sequestration,Compute↗

Water-Oil Displacement in Shale: New Insights from a Comparative Study Integrating Imbibition Tests and Multiscale Imaging

Water-oil displacement is an important process that occurs in a shale matrix after hydraulic fracturing and in water-based enhanced oil recovery. Current understanding of this displacement process is limited because of the complicated pore structure and surface properties in shale. In this work, this process and its controlling factors are investigated through a comparative study of three shale samples that have different types of pore systems and wettability. Here, an integrated method of imbibition and multiscale imaging was applied, and a modified oleic tracer that can better represent oil flow was used in imbibition testing and micro-computed tomography (CT) imaging. Scanning electron microscope (SEM) pore characterization was then performed under high magnification with guidance from the micro-CT images showing the changes caused by oil or water imbibition. New insights were obtained on the importance of both wettability and pore size effect on oil recovery and the distribution of residual oil after water-oil displacement. Connectivity of pores with different wettability is also discussed based on 3D analysis and SEM pore characterization. Collectively, these new findings improve the understanding of the complicated process of water-oil displacement and the role of influencing factors. Important implications for improved oil recovery strategy in shale are discussed for different types of reservoir rocks. The integrated imaging and imbibition technique provides a new path for further investigation of improved oil recovery in shale.

04 OIL SHALES AND TAR SANDS↗

Wettability Alteration with Weak Acid-Assisted Surfactant Flood

Oil-wetness and heterogeneity are two key reasons for low oil recovery by waterflooding in carbonate reservoirs. Surfactants have been effective in altering the oil-wet matrix to a more water-wet condition and initiating spontaneous imbibition. Because it takes time for the surfactant to alter wettability, oil recovery from the tight matrix is slow and sometimes not economically feasible. Acids have the potential of dissolving minerals, which may alter wettability. In this study, the enhanced oil recovery (EOR) performance of an acid-assisted surfactant solution, a novel technique, was evaluated for low-temperature applications. A set of acids and their acetates were tested. Bulk rock-acid reaction, wettability alteration (WA) tests, and spontaneous imbibition measurements were conducted at reservoir temperature (35°C) to identify effective candidates. Coreflood tests were then performed to evaluate the selected acid-surfactant formulations. Before and after a coreflood test, the core was scanned using micro-computed tomography (CT) to investigate pore structure alteration. Bulk reaction measurements showed that weak acids, especially acetic acid (AA), have the desired low reaction rates at 35°C. WA tests showed that AA can remove the crude oil off the rock surface and alter wettability through mineral dissolution. The surfactant can reduce contact angles from 160° to 58°; adding acid into the surfactant can further reduce it to 52°. Spontaneous imbibition experiments showed the synergy between the acid and the surfactant; the AA-surfactant solution had the highest oil recovery (62.6%) among acid-surfactant formulations. The acid improves the WA efficiency by the surfactant through surface mineral dissolution and lower ζ-potential. The imbibition transports the acid-surfactant solutions into the matrix, which minimizes face dissolution. Coreflood tests show that the AA-surfactant flood can increase the oil recovery rate and recover about 8% more oil compared to the surfactant flood. Micro-CT showed that a few mineral particles were transported along the core and partially plugged pore throats, which reduced permeability and diverted flow leading to improved oil recovery. Here, the transport of the acid in reservoirs and the potential plugging issues have to be carefully evaluated in future studies.

58 GEOSCIENCES↗

K-3 Refractory Corrosion Test Results, HAL24M2

This report summarizes the refractory corrosion data of the high-Al matrix of Direct Feed High-Level Waste (DFHLW) glasses generated to expand glass compositional ranges. Design of a 20 high-Al glass matrix, HAL24M2, was reported in Russell et al. (2025, in progress). The HAL24M2 glasses were tested for K-3 corrosion and the results are presented in this report. Corrosion of Monofrax K-3 refractory materials in the HAL24M2 glass melts was measured using a crucible-scale method. Two test conditions, 1150 °C/7days and 1200 °C/7days were applied. The melt-line neck corrosion depth of the test coupons was measured by micro-computed tomography (micro-CT). The measured K-3 neck corrosion values were compared to predicted values using the model in Vienna et al. (2024). The model slightly over-predicted the neck corrosion depth of these glasses.

12 MANAGEMENT OF RADIOACTIVE AND NON-RADIOACTIVE W↗

Impacts of Small-Scale Heterogeneity on Large-Scale Subsurface Flow

Discussion of NETL's CT scanning and core characterization capabilities, followed by a rapid review of several recent publications that utilize these capabilities to answer reservoir questions at the micro scale with relevance to field scale operations.

core characterization↗

Nondestructive Evaluation (NDE) for Characterizing Oxidation Damage in Cracked Reinforced Carbon-Carbon (RCC)

In this study, coated reinforced carbon-carbon (RCC) samples of similar structure and composition as that from the NASA space shuttle orbiter's thermal protection system were fabricated with slots in their coating simulating craze cracks. These specimens were used to study oxidation damage detection and characterization using nondestructive evaluation (NDE) methods. These specimens were heat treated in air at 1143 and 1200 C to create cavities in the carbon substrate underneath the coating as oxygen reacted with the carbon and resulted in its consumption. The cavities varied in diameter from approximately 1 to 3 mm. Single-sided NDE methods were used since they might be practical for on-wing inspection, while x-ray micro-computed tomography (CT) was used to measure cavity sizes in order to validate oxidation models under development for carbon-carbon materials. An RCC sample having a naturally-cracked coating and subsequent oxidation damage was also studied with x-ray micro-CT. This effort is a follow-on study to one that characterized NDE methods for assessing oxidation damage in an RCC sample with drilled holes in the coating.

Roth, Don J.↗

NDE for Characterizing Oxidation Damage in Reinforced Carbon-Carbon

In this study, coated reinforced carbon-carbon (RCC) samples of similar structure and composition as that from the NASA space shuttle orbiter s thermal protection system were fabricated with slots in their coating simulating craze cracks. These specimens were used to study oxidation damage detection and characterization using NDE methods. These specimens were heat treated in air at 1143 and 1200 C to create cavities in the carbon substrate underneath the coating as oxygen reacted with the carbon and resulted in its consumption. The cavities varied in diameter from approximately 1 to 3 mm. Single-sided NDE methods were used since they might be practical for on-wing inspection, while x-ray micro-computed tomography (CT) was used to measure cavity sizes in order to validate oxidation models under development for carbon-carbon materials. An RCC sample having a naturally-cracked coating and subsequent oxidation damage was also studied with x-ray micro-CT. This effort is a follow-on study to one that characterized NDE methods for assessing oxidation damage in an RCC sample with drilled holes in the coating. The results of that study are briefly reviewed in this article as well. Additionally, a short discussion on the future role of simulation to aid in these studies is provided.

Roth, Don J.↗

Nondestructive Evaluation (NDE) for Characterizing Oxidation Damage in Cracked Reinforced Carbon-Carbon

In this study, coated reinforced carbon-carbon (RCC) samples of similar structure and composition as that from the NASA space shuttle orbiter's thermal protection system were fabricated with slots in their coating simulating craze cracks. These specimens were used to study oxidation damage detection and characterization using nondestructive evaluation (NDE) methods. These specimens were heat treated in air at 1143 C and 1200 C to create cavities in the carbon substrate underneath the coating as oxygen reacted with the carbon and resulted in its consumption. The cavities varied in diameter from approximately 1 to 3mm. Single-sided NDE methods were used because they might be practical for on-wing inspection, while X-ray micro-computed tomography (CT) was used to measure cavity sizes in order to validate oxidation models under development for carbon-carbon materials. An RCC sample having a naturally cracked coating and subsequent oxidation damage was also studied with X-ray micro-CT. This effort is a follow-on study to one that characterized NDE methods for assessing oxidation damage in an RCC sample with drilled holes in the coating.

Roth, Don J.↗

Identification of New Lithic Clasts in Lunar Breccia 14305 by Micro-CT and Micro-XRF Analysis

From 1969 to 1972, Apollo astronauts collected 382 kg of rocks, soils, and core samples from six locations on the surface of the Moon. The samples were initially characterized, largely by binocular examination, in a custom-built facility at Johnson Space Center (JSC), and the samples have been curated at JSC ever since. Despite over 40 years of study, demand for samples remains high (~500 subsamples per year are allocated to scientists around the world), particularly for plutonic (e.g., anorthosites, norites, etc.) and evolved (e.g., granites, KREEP basalts) lithologies. The reason for the prolonged interest is that as new scientists and new techniques examine the samples, our understanding of how the Moon, Earth, and other inner Solar System bodies formed and evolved continues to grow. Scientists continually clamor for new samples to test their emerging hypotheses. Although all of the large Apollo samples that are igneous rocks have been classified, many Apollo samples are complex polymict breccias that have previously yielded large (cm-sized) igneous clasts. In this work we present the initial efforts to use the non-destructive techniques of micro-computed tomography (micro-CT) and micro x-ray fluorescence (micro-XRF) to identify large lithic clasts in Apollo 14 polymict breccia sample 14305. The sample in this study is 14305,483, a 150 g slab of regolith breccia 14305 measuring 10x6x2 cm (Figure 1a). The sample was scanned at the University of Texas High-Resolution X-ray CT Facility on an Xradia MicroXCT scanner. Two adjacent overlapping volumes were acquired at 49.2 micrometer resolution and stitched together, resulting in 1766 slices. Each volume was acquired at 100 kV accelerating voltage and 98 mA beam current with a 1 mm CaF2 filter, with 2161 views gathered over 360deg at 3 seconds acquisition time per view. Micro-XRF analyses were done at Washington University in St. Louis, Missouri on an EDAX Orbis PC micro-XRF instrument. Multiple scans were made at 40 kV accelerating voltage, 800 mA beam current, 30 μm beam diameter, and a beam spacing of 30-120 micrometer. The micro-CT scan of 14305,483 (Figure 2) was able to identify several large lithic clasts (approx. 1 cm) within the interior of the slab. These clasts will be exposed by band-sawing or chipping of the slab, and their composition more fully characterized by subsequent micro-XRF analysis. In addition to lithic clasts, the micro-CT scans identified numerous mineral clasts, including many FeNi metal grains, as well as the prominent fractures within the slab. The micro-XRF analyses (Figure 1b,c) of the slab surfaces revealed the bulk chemical compositions (qualitative) of the different clast types observed. In particular, by looking at the ratios of major elements (e.g. Ca:Mg:Fe), differences among the many observed clast types are readily observed. Moreover, several clasts not apparent to the naked eye were revealed in the K:Al:Si ratio map. The scans are also able to identify small grains of Zr- and P-rich minerals (not shown), which could in turn yield important age dates for the samples.

Zeigler, Ryan A.↗

X-Ray Micro-Computed Tomography of Apollo Samples as a Curation Technique Enabling Better Research

X-ray micro-computed tomography (micro-CT) is a technique that has been used to research meteorites for some time and many others], and recently it is becoming a more common tool for the curation of meteorites and Apollo samples. Micro-CT is ideally suited to the characterization of astromaterials in the curation process as it can provide textural and compositional information at a small spatial resolution rapidly, nondestructively, and without compromising the cleanliness of the samples (e.g., samples can be scanned sealed in Teflon bags). This data can then inform scientists and curators when making and processing future sample requests for meteorites and Apollo samples. Here we present some preliminary results on micro-CT scans of four Apollo regolith breccias. Methods: Portions of four Apollo samples were used in this study: 14321, 15205, 15405, and 60639. All samples were 8-10 cm in their longest dimension and approximately equant. These samples were micro-CT scanned on the Nikon HMXST 225 System at the Natural History Museum in London. Scans were made at 205-220 kV, 135-160 microamps beam current, with an effective voxel size of 21-44 microns. Results: Initial examination of the data identify a variety of mineral clasts (including sub-voxel FeNi metal grains) and lithic clasts within the regolith breccias. Textural information within some of the lithic clasts was also discernable. Of particular interest was a large basalt clast (approx.1.3 cc) found within sample 60639, which appears to have a sub-ophitic texture. Additionally, internal void space, e.g., fractures and voids, is readily identifiable. Discussion: It is clear from the preliminary data that micro-CT analyses are able to identify important "new" clasts within the Apollo breccias, and better characterize previously described clasts or igneous samples. For example, the 60639 basalt clast was previously believed to be quite small based on its approx.0.5 sq cm exposure on the surface of the main mass. These scans show the clast to be approx.4.5 g, however (assuming a density of approx.3.5 g/cc). This is large enough for detailed studies including multiple geo-chronometers. This basalt clast is of particular interest as it is the largest Apollo 16 basalt, and it is the only mid-TiO2 basalt in the Apollo sample suite. By identifying the location of interesting clasts or grains within a sample, we will be able to make more informed decisions about where to cut a sample in order to best expose clasts of interest for future study. Moreover, knowing the location of internal defects (e.g., fractures) will allow more precise chipping and extraction of clasts or grains. By combining micro-CT scans with compositional techniques like micro x-ray fluorescence (particularly on sawn slabs), we will be able to provide even more comprehensive information to scientists trying to best select samples that fit their scientific needs.

Ziegler, R. A.↗