Search NASA⌕ Search

SEARCH · Search NASA

Results for “microbeam”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Heavy Ion Microbeam- and Broadbeam-Induced Current Transients in SiGe HBTs

IBM 5AM SiGe HBT is device-under-test. High-speed measurement setup. Low-impedance current transient measurements. SNL, JYFL, GANIL. Microbeam to broadbeam position inference. Improvement to state-of-the-art. Microbeam (SNL) transients reveal position dependent heavy ion response, Unique response for different device regions Unique response for different bias schemes. Similarities to TPA pulsed-laser data. Broadbeam transients (JYFL and GANIL) provide realistic heavy ion response. Feedback using microbeam data. Overcome issues of LET and ion range with microbeam. **Angled Ar-40 data in full paper. Data sets yield first-order results, suitable for TCAD calibration feedback.

Pellish, Jonathan A.↗

The Mars Microbeam Raman Spectrometer (MMRS): From Concept to Category-1 Proposal

Laser Raman Spectroscopy is flexible and can be deployed in many ways. The Mars Microbeam Raman Spectrometer (MMRS) is tailored for rover-based mobility platform and for Mars fundamental science objectives. The MMRS was initiated by science requirements to determine mineralogy, mineral chemistry, and molecular phase identification, including organics. MMRS is ready for any near term mission to Mars and the Moon. Science is the driving force for development.

mobility↗

The Mars Microbeam Raman Spectrometer (MMRS)

The Mars Microbeam Raman Spectrometer can identify minerals in situ, determine rock types and textures, provide some mineral chemistry, detect organic and biogenic materials, and identify bound water. Additional information is contained in the original extended abstract.

Haskin, L. A.↗

Mars Mineralogy by Microbeam Raman Spectrometry

The Mars Microbeam Raman Spectrometer, under development at Washington University and the Jet Propulsion Laboratory, can identify oxide, sulfide, and oxyanion minerals, bound water and OH, and organic and graphitic carbon in Mars rocks and soils in situ. Additional information is contained in the original extended abstract.

Haskin, Larry A.↗

Heavy Ion Microbeam and Broadbeam Transients in SiGe HBTs

SiGe HBT heavy ion current transients are measured using microbeam and both high- and low-energy broadbeam sources. These new data provide detailed insight into the effects of ion range, LET, and strike location.

Pellish, Jonathan A.↗

Heavy Ion Microbeam- and Broadbeam-Induced Transients in SiGe HBTs

SiGe HBT heavy ion-induced current transients are measured using Sandia National Laboratories microbeam and high- and low-energy broadbeam sources at the Grand Accelerateur National d'Ions Lourds and the University of Jyvaskyla. The data were captured using a custom broadband IC package and real-time digital phosphor oscilloscopes with at least 16 GHz of analog bandwidth. These data provide detailed insight into the effects of ion strike location, range, and LET.

Pellish, Jonathan A.↗

Microbeam analysis of four chondritic interplanetary dust particles for major elements, carbon and oxygen

Chemical compositions determined using electron excited X-rays are reported for four interplanetary dust particles collected in the stratosphere. These analyses include measurements of carbon and oxygen abundances which are important elements in these primitive materials. Spot analyses show very heterogeneous compositions on a micrometer scale although average composition approaches that of C1 carbonaceous chondrites. While the spot analyses show intermediate compositions between cometary dust and carbonaceous chondrites, the heterogeneity more closely resembles that of comet Halley dust particles.

Blanford, G. E.↗

Microbeam Investigations of Presolar and Early Solar System Materials

This grant provided three years of funding to initiate an independent research program in Cosmochemistry at Arizona State University. Because the new equipment that was installed at ASU took longer than expected to get running, the project was extended for a fourth year with no additional funding. By the time the funds were expended, we had set up an entirely new ion microprobe laboratory at ASU, and we have been fully operational for over two years. This laboratory was funded in almost equal parts by NASA, NSF, and ASU. Papers describing the first results from this new laboratory are being published now, and the results have been making an impact on the Cosmochemistry community. While this laboratory was being built, I continued my research program in collaboration with G. J. Wasserburg at Caltech. As equipment became available, I gradually shifted my research to ASU. Over the lifetime of this grant, my research program resulted in 12 papers and 13 abstracts on topics ranging from presolar grains (2 papers, 3 abstracts), short-lived radionuclides (6 papers, 6 abstracts), chemical compositions of chondritic materials (3 papers, 3 abstracts), silicon isotopic fractionation (1 abstract), and the oxygen composition of the Sun (1 paper). The most important results of this period were the discovery of presolar hibonite in a meteorite residue, the measurement of 26A1 in CAIs from enstatite chondrites, and the measurements of 10Be in type A CAIs from CV chondrites. All of these results have had a significant impact on research in Cosmochemstry.

Huss, Gary R.↗

The Mars Microbeam Raman Spectrometer: An Improved Advanced Brassboard

An advanced brassboard (ADBB) of the Mars Miscrobeam Raman Spectrometer is being developed. The probe and spectrograph have been redesigned with improved optics and the electronics have been miniaturized. The modified optical design in the probe and spectrograph provides better spectral resolution than the previous model and enables the probe design to be more compatible with robotic arm deployment. The CCD detector is now cooled thermoelectrically in anticipation of eventual terrestrial field testing of the instrument.

Haskin, L. A.↗

Oxygen Isotopes in Early Solar System Materials: A Perspective Based on Microbeam Analyses of Chondrules from CV Carbonaceous Chondrites

Some of the biggest challenges to understanding the early history of the solar system include determining the distribution of oxygen isotopes amongst materials that existed in the solar nebula, and interpreting the processes that might have resulted in the observed isotopic distributions. Oxygen isotope ratios in any individual mineral grain from a chondritic meteorite may be the cumulative product of a variety of processes, including stellar nucleosynthetic events, gas/solid interactions in the molecular cloud, mixing of independent isotopic reservoirs in the nebula, mass-independent processing in the nebula, and mass-dependent fractionation effects in various environments. It is not possible to unravel this complex isotopic record unless the distribution of oxygen isotope ratios in chondritic materials is fully understood.

Jones, R. H.↗

Microbeam studies of the sensitivity of structures within living cells

Determining the biological effects of low doses of radiation with high linear energy transfer (LET) is complicated by the stochastic nature of charged-particle interactions. Populations of cells exposed to very low radiation doses contain a few cells which have been hit by a charged particle, while the majority of the cells receive no radiation damage. At somewhat higher doses, a few cells receive two or more events. Because the effects of damage produced by separate events can interact in the cell, we have had to make assumptions about the nature of these interactions in order to interpret the results of the experiments. Many of those assumptions can be tested if we can be sure of the number of charged-particle events which occur in individual cells, and correlate this number with the biological effect. We have developed a special irradiation facility at Pacific Northwest Laboratory (PNL) to control the actual number of charged particle tracks that pass through cell nuclei. The beam from a 2 MeV tandem accelerator is collimated to approximately 5 microns. Cells, grown in special dishes with 1.5 microns thick plastic bottoms, are positioned so that the desired portion of the cell aligns with the collimator. A shutter in the beam line is opened and closed after the desired number of particle tracks has been counted. This approach can be used to investigate the effects of the interaction between irradiated and unirradiated cells in an organized system, as well as to study the effects of spatial and temporal distribution of radiation damage within single cells.(ABSTRACT TRUNCATED AT 250 WORDS).

Non-NASA Center↗

Microbeam Investigations of Presolar and Early Solar System Materials

This grant provided three years of funding for my Cosmochemistry research program at Arizona State University. This research resulted in 11 peer-reviewed papers in six Journals and 35 abstracts to 11 Conferences and Workshops (see list below). My original proposal listed three main areas of research: 1) Studies of presolar grains; 2) Studies of short-lived radionuclides and; 3) Investigations of nebular processes and the origin of chondritic components.

Huss, Gary R.↗

Characterization of Apollo Regolith by X-Ray and Electron Microbeam Techniques: An Analog for Future Sample Return Missions

The Apollo missions collected 382 kg of rock and regolith from the Moon; approximately 1/3 of the sample mass collected was regolith. Lunar regolith consists of well mixed rocks, minerals, and glasses less than 1-centimeter n size. The majority of most surface regolith samples were sieved into less than 1, 1-2, 2-4, and 4-10- millimiter size fractions; a portion of most samples was re-served unsieved. The initial characterization and classification of most Apollo regolith particles was done primarily by binocular microscopy. Optical classification of regolith is difficult because (1) the finest fraction of the regolith coats and obscures the textures of the larger particles, and (b) not all lithologies or minerals are uniquely identifiable optically. In recent years, we have begun to use more modern x-ray beam techniques [1-3], coupled with high resolution 3D optical imaging techniques [4] to characterize Apollo and meteorite samples as part of the curation process. These techniques, particularly in concert with SEM imaging of less than 1-millimeter regolith grain mounts, allow for the rapid characterization of the components within a regolith.

Zeigler, Ryan A.↗

Single Event Transient Analysis of an SOI Operational Amplifier for Use in Low-Temperature Martian Exploration

The next generation of Martian rover#s to be launched by JPL are to examine polar regions where temperatures are extremely low and the absence of an earth-like atmosphere results in high levels of cosmic radiation at ground level. Cosmic rays lead to a plethora of radiation effects including Single Event Transients (SET) which can severely degrade microelectronic functionality. As such, a radiation-hardened, temperature compensated CMOS Single-On-Insulator (SOI) Operational Amplifier has been designed for JPL by the University of Tennessee and fabricated by Honeywell using the SOI V process. SOI technology has been shownto be far less sensitive to transient effects than both bulk and epilayer Si. Broad beam heavy-ion tests at the University of Texas A&M using Kr and Xebeams of energy 25MeV/amu were performed to ascertain the duration and severity of the SET for the op-amp configured for a low and high gain application. However, some ambiguity regarding the location of transient formation required the use of a focused MeV ion microbeam. A 36MeV O6(+) microbeam. the Sandia National Laboratory (SNL) was used to image and verify regions of particular concern. This is a viewgraph presentation

operational amplifier↗

High-Speed Single-Event Current Transient Measurements in SiGe HBTs

Time-resolved ion beam induced charge reveals heavy ion response of IBM 5AM SiGe HBT: 1) Position correlation. 2) Unique response for different bias schemes. 3) Similarities to TPA pulsed-laser data. Heavy ion broad-beam transients provide more realistic device response: 1) Feedback using microbeam data 2) Overcome existing issues of LET and ion range with microbeam Both micro- and broad-beam data sets yield valuable input for TCAD simulations. Uncover detailed mechanisms for SiGe HBTs and other devices fabricated on lightly-doped substrates.

Pellish, Jonathan A.↗