Search NASA⌕ Search

SEARCH · Search NASA

Results for “microcalorimeter”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Progress Towards Microcalorimeter Gamma Spectroscopy Analysis for Nuclear Fuel Separations

The High Efficiency and Resolution Microcalorimeter Spectrometer, 400 pixels (HERMES-400) is an ultra-high resolution gamma-ray spectrometer at Idaho National Laboratory’s Materials and Fuels Complex. HERMES-400 is intended to enable precise nondestructive analysis of advanced fuel cycle materials. Key upgrades and repairs of the instrument were performed this year to improve performance. First, the fourth and final microcalorimeter detector module was installed, meeting the milestone for its integration into the system. Operation with all four modules enables higher detector efficiency than any previous microcalorimeter gamma-ray system. Second, a thinner magnetic shield was installed. This shields the sensitive microcalorimeter pixels from stray magnetic fields while allowing transmission of lower-energy gamma rays, which are important to isotopic analysis. Finally, the cryostat, which provides cooling of the modules to their operating temperature, was found to have a helium coolant leak, which was repaired. HERMES-400 is in a stable state to perform repeated, long-term gamma-ray measurements with good detector efficiency and energy resolution. In FY25, irradiated TRISO fuel and salts from advanced electrochemical recycling techniques are candidates for microcalorimeter measurements. A final upgrade of the magnetic shielding and vibration damping of the system is also planned to maximize the system performance.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Line emission mapper microcalorimeter spectrometer

The line emission mapper (LEM) is a probe-class mission concept that is designed to detect x-ray emission lines from hot ionized gas (T > 10 6 K) that will enable us to test galaxy evolution theories. It will permit us to study the effects of stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. The key to being able to study the hot gases that are otherwise invisible to current imaging x-ray spectrometers is that the energy resolution is sufficient to use cosmological redshift to separate extragalactic source lines from foreground Milky Way emission. LEM incorporates a large-format microcalorimeter array instrument called the LEM microcalorimeter spectrometer (LMS) with a light-weight x-ray optic with 10” half power diameter angular resolution. The LMS microcalorimeter array has pixels with 15" pixel pitch over a 33' field of view (FOV) optimized for the 0.3 to 2 keV energy band. The central 7' region of the array has an energy resolution of 1.3 eV at 1 keV and the rest of the FOV has 2.5 eV energy resolution at 1 keV. The array will be read out with state-of-the-art time-division multiplexing. We present an overview of the LMS instrument, including details of the entire detection chain, the focal plane assembly, as well as the cooling system and overall mechanical and thermal design. For each of the key technologies, we discuss the current technology readiness level and the plan to advance them to be ready for flight. We also describe the current system design and our estimate for the mass, power, and data rate of the instrument. The design details presented concentrate primarily on the unique aspects of the LMS design compared with prior missions and confirm that the type of microcalorimeter instrument needed for LEM is not only feasible but also technically mature.

47 OTHER INSTRUMENTATION↗

Absorber Clamp for Microcalorimeter Decay Energy Spectrometry

Microcalorimeter Decay Energy Spectrometry (DES) is of interest to nuclear safeguards due to its ability to provide high precision isotopic compositions of nanogram-to microgram-scale samples of Pu and U and related daughter products. The DES method is able to record decay energy of each alpha-decay event in a sample that is embedded in a metal matrix (absorber) and thermally linked to a microcalorimeter detector. This work optimizes the DES technique used to thermally link the absorber and microcalorimeter detector element to allow for more rapid assembly and to increase detector performance and operating life. Optimized attachment methods are crucial for enhancing the viability of DES in high-sample-throughput facilities, such as those that support international nuclear safeguards measurements. Here, in this study, we designed and implemented a pressure-based absorber clamp and evaluated the performance of this new attachment method relative to pressed indium bond attachment. Results using the absorber clamp demonstrate a streamlined detector assembly procedure that minimizes accidental damage to detectors, as well as increasing detector pulse speeds by 57%. Spectral comparison shows the clamp preserves detector performance relative to indium attachment.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Development of the microcalorimeter and anticoincidence detector for the Line Emission Mapper x-ray probe

The Line Emission Mapper (LEM) is an x-ray probe mission concept that is designed to provide unprecedented insight into the physics of galaxy formation, including stellar and black-hole feedback and flows of baryonic matter into and out of galaxies. LEM incorporates a light-weight x-ray optic with a large-format microcalorimeter array. The LEM detector utilizes a 14k pixel array of transition-edge sensors (TESs) that will provide <2.5 eV spectral resolution over the energy range 0.2 to 2 keV, along with a field-of-view of 30 arcmin. The microcalorimeter array and readout builds upon the technology developed for the European Space Agency’s (ESA’s) Athena/x-ray Integral Field Unit. Here, we present a detailed overview of the base- line microcalorimeter design, its performance characteristics, including a detailed energy resolution budget and the expected count-rate capability. In addition, we outline the current status and plan for continued technology maturation. Behind the LEM array sits a high-efficiency TES-based anticoincidence (antico) detector that will reject cosmic-ray background events. We will briefly describe the design of the antico and plan for continued development.

47 OTHER INSTRUMENTATION↗

High-count-rate effects in event processing for the XRISM/Resolve X-ray microcalorimeter. II. Energy scale and resolution in orbit

The Resolve instrument on the X-ray Imaging and Spectroscopy Mission (XRISM) uses a 36 pixel microcalorimeter designed to deliver high-resolution, non-dispersive X-ray spectroscopy. Although it is optimized for extended sources with low count rates, Resolve observations of bright point sources are still able to provide unique insights into the physics of these objects, as long as high-count-rate effects are addressed in the analysis. These effects include the loss of exposure time for each pixel, changes in the energy scale, and changes in the energy resolution. To investigate these effects under realistic observational conditions, we observed the bright X-ray source, the Crab Nebula, with XRISM at several offset positions with respect to the Resolve field of view and with continuous illumination from 55 Fe sources on the filter wheel. For the spectral analysis, we excluded data where exposure-time loss was too significant to ensure reliable spectral statistics. The energy scale at 6 keV shows a slight negative shift in the high-count-rate regime. The energy resolution at 6 keV worsens as the count rate in electrically neighboring pixels increases, but can be restored by applying a nearest-neighbor coincidence cut (“cross-talk cut”). We examined how these effects influence the observation of bright point sources, using GX 13+1 as a test case, and identified an eV-scale energy offset at 6 keV between the inner (brighter) and outer (fainter) pixels. Users who seek to analyze velocity structures on the order of tens of km s–1 should account for such high-count-rate effects. These findings will aid in the interpretation of Resolve data from bright sources and provide valuable considerations for designing and planning for future microcalorimeter missions.

X-rays: general↗

High-count rate effects in event processing for XRISM/ Resolve X-ray microcalorimeter: I. Ground test

The spectroscopic performance of an X-ray microcalorimeter is compromised at high count rates. We utilize the Resolve X-ray microcalorimeter onboard the XRISM satellite to examine the effects observed during high-count rate measurements and propose modeling approaches to mitigate them. We specifically address the following instrumental effects that impact performance: CPU limit, pile-up, and untriggered electrical cross-talk. Experimental data at high count rates were acquired during ground testing using the flight model instrument and a calibration X-ray source. In the experiment, data processing not limited by the performance of the onboard CPU was run in parallel, which cannot be done in orbit. This makes it possible to access the data degradation caused by limited CPU performance. We use these data to develop models that allow for a more accurate estimation of the aforementioned effects. To illustrate the application of these models in observation planning, we present a simulated observation of GX 13+1. Understanding and addressing these issues is crucial to enhancing the reliability and precision of X-ray spectroscopy in situations characterized by elevated count rates.

47 OTHER INSTRUMENTATION↗

Absolute timing calibration of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

The Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM) is designed to have a good timing capability with the mission-level requirement of 1 ms as the absolute time tagging accuracy to suffice the needs for observatory science. In the ground calibration campaign, the absolute and relative timing offsets were measured using pulsed X-rays from the modulated X-ray sources. These offsets were used to determine calibration parameters, the Resolve timing coefficients, which are used in the offline correction of event times. In the orbit, reevaluation of the timing coefficients was carried out using the Crab pulsar, which was observed in two periods, one in the performance verification phase and the other in the guest observation phase. We report the absolute timing calibration of XRISM/Resolve using the ground and in-orbit data. Although the requirement is likely satisfied with the ground parameters, the timing coefficients have been refined using the in-orbit calibration to improve the timing accuracy. In addition, for the first time, we present the interpretation of the absolute timing offset originating from the analog and digital processing of X-ray events unique to a microcalorimeter spectrometer and present a complete view of the timing error of the Resolve instrument.

Astronomy and AstroPhysics↗

Energy gain scale calibration of the XRISM Resolve microcalorimeter spectrometer: ground calibration results and on-orbit comparison

The Resolve instrument aboard the X-ray Imaging and Spectroscopy Mission (XRISM) is a 36-pixel microcalorimeter spectrometer that provides nondispersive spectroscopy with ∼ 5 eV spectral resolution in the soft X-ray waveband. Resolve has a requirement to provide an absolute energy-scale calibration of ± 2 eV from 0.3 to 12 keV. We describe our ground calibration strategy and results of a subset of the ground calibration campaigns, including a discussion of improvements in the energy scale ground calibration compared with Hitomi’s. These improvements include calibration of the low-energy band below 4 keV with the instrument in the flight dewar and the dewar aperture door open, which was not performed for Hitomi, and thorough measurements over an extended high-energy waveband to 22 keV. We also developed an improved technique for gain calibration of “mid-res” secondary events, which have suppressed gain due to proximity to a preceding X-ray event (18 to 70 ms) on the same pixel. We provide a discussion of the on-orbit energy scale monitoring campaigns and an assessment of the Resolve energy scale uncertainties, a key parameter for astrophysics analysis. Energy-scale calibration approaches for future space-based instruments, including the X-ray Integral Field Unit on Athena and microcalorimeter spectrometers proposed or under discussion for future X-ray observatory concepts, have heritage in the calibration of XRISM. We briefly comment on lessons learned from Resolve calibration that are relevant for these future instruments.

Aluminum↗

Adapting High-Resolution X-Ray Microcalorimeter Spectrometers to Transform MFE Plasma Diagnostics

The aim of this project was to begin the transformation of magnetic fusion energy (MFE) X-ray diagnostics by applying detector technology developed over the past several decades by the astrophysics community. We installed and operated an X-ray microcalorimeter detector system under fusion-relevant plasma conditions at the Madison Symmetric Torus (MST). X-ray microcalorimeter spectrometers combine the best characteristics of instrumentation currently available on fusion devices: the high spectral resolution of crystal spectrometers (2 eV) and broadband coverage provided by pulse-height analysis systems. These spectrometers have small port-access requirements, a key advantage for future MFE experiments. This new plasma diagnostic technique will satisfy the need for multispecies impurity ion data by providing absolute measurements of impurity core accumulation, and it will provide the core impurity ion temperature. This project was a joint effort between Lawrence Livermore National Laboratory (LLNL) and researchers at the Wisconsin Plasma Physics Laboratory (WiPPl) at the University of Wisconsin–Madison (UW–Madison). Megan E. Eckart is the principal investigator at LLNL, which is funded separately from UW–Madison. This final report fulfills the reporting obligation of the UW–Madison effort.

Den Hartog, Daniel J. [Department of Physics, Univ↗

High Resolution Fission Fragment Spectroscopy with Superconducting Microcalorimeters

Sub-1 AMU mass determination is important for determining fission yields and neutron multiplicity, which are necessary inputs for fission models. Fission models can improve spent nuclear waste stream analysis and nuclear fuel burnup determination. Here, to achieve this goal, we have used superconducting microcalorimeter detectors to directly measure the energy of fission fragments from the spontaneous fission of 252 Cf. With a fiber coupled LED pulser setup we demonstrate that we can reach a relative energy resolution of 0.1% and better for photon pulses with energies above 60 MeV. This instrument, in conjunction with time-of-flight (TOF) measurement, would allow for sub-1 atomic mass unit (AMU) mass determination of fission fragments in a future beamline application.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Strategies for the in-orbit gain tracking using the modulated X-ray sources for the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission

Accurate and precise correction of the gain drift is the key to achieve the required energy resolution of the Resolve microcalorimeter spectrometer on the X-ray Imaging and Spectroscopy Mission (XRISM). Therefore, Resolve is equipped with highly configurable X-ray sources called the modulated X-ray source (MXS). The pulsed nature allows us to separate calibration and astrophysical X-rays by time interval selections. However, undesirable characteristics of the MXS, such as the afterglow X-rays, restrict the allowed configuration range. Moreover, the nonlinear and discontinuous behaviors of the calibration line count rate make the determination of the optimal setting highly complex. The MXS count rate model has been established using measurements in the spacecraft thermal vacuum test with the flight detector and MXS. A trade-off study using the model enables us to choose a few settings for the continuous use of the MXS optimized for different ranges of target gain tracking intervals. An alternative approach, where the MXS is used only intermittently, has also been developed and implemented. This new mode enables us to reconstruct the drift without having most of the undesirable effects in science data. This also forms the basis of the gain tracking under the current Resolve configuration with the closed gate valve.

Astronomy and AstroPhysics↗

ASCENT: a balloon-borne hard x-ray imaging spectroscopy telescope using transition edge sensor microcalorimeter detectors

Core collapse supernovae are thought to be one of the main sources in the galaxy of elements heavier than iron. Understanding the origin of the elements is thus tightly linked to our understanding of the explosion mechanism of supernovae and supernova nucleosynthesis. X-ray and gamma-ray observations of young supernova remnants, combined with improved theoretical modeling, have resulted in enormous improvements in our knowledge of these events. Here, the isotope Ti44 is one of the most sensitive probes of the innermost regions of the core collapse engine, and its spatial and velocity distribution are key observables. Hard x-ray imaging spectroscopy with the Nuclear Spectroscopic Telescope Array (NuSTAR) has provided new insights into the structure of the supernova remnant Cassiopeia A (Cas A), establishing the convective nature of the supernova engine. However, many questions about the details of this engine remain. We present here the concept for a balloon-borne follow-up mission called A SuperConducting ENergetic x-ray Telescope (ASCENT). ASCENT uses transition edge sensor gamma-ray microcalorimeter detectors with a demonstrated 55-eV full-width half maximum energy resolution at 97 keV. This 8- to 16-fold improvement in energy resolution over NuSTAR will allow for high-resolution imaging and spectroscopy of the Ti44 emission. This will allow for a detailed reconstruction of gamma-ray line redshifts, widths, and shapes, allowing us to address questions such as, What is the source of the neutron star kicks? What is the dominant production pathway for Ti44? Is the engine of Cas A unique?

79 ASTRONOMY AND ASTROPHYSICS↗

First flight performance of the Micro-X microcalorimeter X-ray sounding rocket

The flight of the Micro-X sounding rocket on July 22, 2018, marked the first operation of transition-edge sensors and their superconducting quantum interference device readouts in space. Here, the instrument combines the microcalorimeter array with an imaging mirror to take high-resolution spectra from extended X-ray sources. The first flight target was the Cassiopeia A supernova remnant. Although a rocket pointing malfunction led to no time on-target, data from the flight were used to evaluate the performance of the instrument and demonstrate the flight viability of the payload. The instrument successfully achieved a stable cryogenic environment, executed all flight operations, and observed X-rays from the on-board calibration source. The flight environment did not significantly affect the performance of the detectors compared with ground operation. The flight provided an invaluable test of the impact of external magnetic fields and the instrument configuration on detector performance. This flight provides a milestone in the flight readiness of these detector and readout technologies, both of which have been selected for future X-ray observatories.

79 ASTRONOMY AND ASTROPHYSICS↗

Hunting Sub-GeV Dark Matter with Diamonds and Magnetic Microcalorimeters Principle

This project is to study feasibility of a new concept for the sub-GeV dark matter (DM) detection using diamond crystals and magnetic microcalorimeters (MMCs). Diamond crystals are made of low mass carbon constituent that maximize kinetic energy of nuclear recoils from sub-GeV DM scattering due to their relatively similar masses. MMC is employed as a sensitive phonon sensor to measure athermal phonons that are produced by DM scattering in diamond crystals with 100 ns timing resolution and ~10 eV energy resolution. MMC’s fast timing resolution allows high precision phonon pulse shape analysis to separate out unwanted background or noise signals in the low energy region at E < 1 keV. Especially, the low energy excess (LEE) problems have been reported in the dark matter detection community and the proposed diamond-MMC detector might be able to provide important information to understand the origins of LEE signals in DM detectors. In this project a diamond-MMC detector has been built for proof-of-concept experiments and athermal phonon collection efficiencies have been investigated for single crystal and poly-crystal chemical-vapour-diamonds (SC and PC CVDs) as well as reference sapphire crystals are tested in the same geometries to quatify athermal phonon propagation and their collection to the MMC phonon sensors. Athermal phonon collection efficiencies and their lifetime in the diamond and sapphire crystals are successfully measured in the same geometry and experimental setup for comparison. SC CVD crystals exhibit poorer performance than the sapphire reference crystals in athermal phonon collection, while the PC CVD crystal exhibit better result than the sapphire. PC CVD with MMC phonon sensors would be feasible for sub GeV DM detection.

72 PHYSICS OF ELEMENTARY PARTICLES AND FIELDS↗

Development of Fast Decay-Energy Spectroscopy With Magnetic Microcalorimeters

Decay energy spectroscopy (DES) is an increasingly important radiometric technique arising from the unique thermal detection physics and the precision of low-temperature microcalorimetry. DES can enable high-precision analysis of very small amounts of radioactive material with simple and rapid sample preparation, making it a key new tool for nuclear safeguards, nuclear forensics, the improvement of nuclear data, measurements of absolute activity, and other applications. For problems in nuclear safeguards and nuclear forensics it is highly desirable to increase the count rates achievable in DES, while maintaining simple and rapid sample preparation. Here, in this report, we describe progress in a new project to achieve high count rates in DES by taking advantage of the physics of magnetic microcalorimetry. We describe the results of initial modeling and experiment to validate the idea, a sample fabrication technique suitable for nuclear materials laboratories, the preparation and initial tests of paramagnetic Au-Er alloy in thin foil form, and the development of a sensing coil geometry that will perform well with the increased-thickness sensor used in the new technique.

73 NUCLEAR PHYSICS AND RADIATION PHYSICS↗

Ground calibration plan for the Athena/X-IFU microcalorimeter spectrometer

The X-ray Integral Field Unit is the X-ray imaging spectrometer on board one of ESA’s next large missions, Athena. Athena is set to investigate the theme of the Hot and Energetic Universe, with a launch planned in the late-2030s. Based on a high-sensitivity transition edge sensor (TES) detector array operated at very low temperature (50 mK), X-IFU will provide spatially resolved high-resolution spectroscopy of the X-ray sky in the 0.2 to 12 keV energy band, with an energy resolution goal of 4 eV up to 7 keV [3 eV design goal]. This work presents the current calibration plan of the X-IFU. It provides the requirements applicable to the X-IFU calibration, describes the overall calibration strategy, and details the procedure and sources needed for the ground calibration of each parameter or characteristics of the X-IFU.

47 OTHER INSTRUMENTATION↗