SEARCH · Search NASA
Results for “microcapillary”
Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.
Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.
Effusive atomic oven nozzle design using an aligned microcapillary array
We present a simple and inexpensive design for a multichannel effusive oven nozzle which provides improved atomic beam collimation and thus extended oven lifetimes. Using this design, we demonstrate an atomic lithium source suitable for trapped-atom experiments. At a nozzle temperature of 525 °C, the collimated atomic beam flux directly after the nozzle is 1.2 × 10{sup 14} atoms/s with a peak beam intensity greater than 5.0 × 10{sup 16} atoms/s/sr. This suggests an oven lifetime of several decades of continuous operation.
Anomalous scattering, transport, and spatial distribution of X-ray fluorescence at the exit of polycapillary structures
The angular distribution of the X-ray intensity at the exit of microchannel plates at grazing incidence of monochromatic radiation on the walls of microcapillaries has been investigated. The angles and energies of the primary radiation quanta at which the synchrotron beam excites X-ray fluorescence propagating inside polycapillary structures have been determined. The angular dependences of the intensity distribution of X-rays transmitted through the microcapillaries have been studied theoretically and experimentally for energies corresponding to the region of anomalous dispersion near the L{sub 2,3} absorption edges of silicon. The propagation of waves in hollow polycapillary waveguides, the excitation of X-ray fluorescence, and the X-ray diffraction at the exit of microchannel plates have been modeled mathematically. The mathematical model takes into account the presence of a transition layer on the microchannel surface.
Microfluidic-Based sample chips for radioactive solutions
Historical nuclear fuel cycle process sampling techniques required sample volumes ranging in the tens of milliliters. The radiation levels experienced by analytical personnel and equipment, in addition to the waste volumes generated from analysis of these samples, have been significant. These sample volumes also impacted accountability inventories of required analytes during process operations. To mitigate radiation dose and other issues associated with the historically larger sample volumes, a microcapillary sample chip was chosen for further investigation. The ability to obtain microliter volume samples coupled with a remote automated means of sample loading, tracking, and transporting to the analytical instrument would greatly improve analytical efficiency while reducing both personnel exposure and radioactive waste volumes. Sample chip testing was completed to determine the accuracy, repeatability, and issues associated with the use of microfluidic sample chips used to supply µL sample volumes of lanthanide analytes dissolved in nitric acid for introduction to an analytical instrument for elemental analysis.
Novel pore size-controlled, susceptibility matched, 3D-printed MRI phantoms
We report the design concept and fabrication of MRI phantoms, containing blocks of aligned microcapillaires that can be stacked into larger arrays to construct diameter distribution phantoms or fractured, to create a “powder-averaged” emulsion of randomly oriented blocks for vetting or calibrating advanced MRI methods, that is, diffusion tensor imaging, AxCaliber MRI, MAP-MRI, and multiple pulsed field gradient or double diffusion-encoded microstructure imaging methods. The goal was to create a susceptibility-matched microscopically anisotropic but macroscopically isotropic phantom with a ground truth diameter that could be used to vet advanced diffusion methods for diameter determination in fibrous tissues. Two-photon polymerization, a novel three-dimensional printing method is used to fabricate blocks of capillaries. Double diffusion encoding methods were employed and analyzed to estimate the expected MRI diameter. Susceptibility-matched microcapillary blocks or modules that can be assembled into large-scale MRI phantoms have been fabricated and measured using advanced diffusion methods, resulting in microscopic anisotropy and random orientation. This phantom can vet and calibrate various advanced MRI methods and multiple pulsed field gradient or diffusion-encoded microstructure imaging methods. We demonstrated that two double diffusion encoding methods underestimated the ground truth diameter.
Ultrasound Manipulation and Extrusion of Active Nanorods
Abstract Synthetic self‐propelled nano and microparticles have a growing appeal for targeted drug delivery, collective functionality, and manipulation at the nanoscale. However, it is challenging to control their positions and orientations under confinement, e.g., in microchannels, nozzles, and microcapillaries. This study reports on the synergistic effect of acoustic and flow‐induced focusing in microfluidic nozzles. In a microchannel with a nozzle, the balance between the acoustophoretic forces and the fluid drag due to streaming flows generated by the acoustic field controls the microparticle's dynamics. This study manipulates the positions and orientations of dispersed particles and dense clusters inside the channel at a fixed frequency by tuning the acoustic intensity. The main findings are: first, this study successfully manipulates the positions and orientations of individual particles and dense clusters inside the channel at a fixed frequency by tuning the acoustic intensity. Second, when an external flow is applied, the acoustic field separates and selectively extrudes shape‐anisotropic passive particles and self‐propelled active nanorods. Finally, the observed phenomena are explained by multiphysics finite‐element modeling. The results shed light on the control and extrusion of active particles in confined geometries and enable applications for acoustic cargo (e.g., drug) delivery, particle injection, and additive manufacturing via printed self‐propelled active particles.
Fabrication of a single sub-micron pore spanning a single crystal (100) diamond membrane and impact on particle translocation [Particle translocation through a single crystal diamond pore fabricated by electron beam induced chemical etching]
The fabrication of sub-micron pores in single crystal diamond membranes, which span the entirety of the membrane, is described for the first time, and the translocation properties of polymeric particles through the pore investigated. The pores are produced using a combination of laser micromachining to form the membrane and electron beam induced etching to form the pore. Single crystal diamond as the membrane material, has the advantages of chemical stability and durability, does not hydrate and swell, has outstanding electrical properties that facilitate fast, low noise current-time measurements and is optically transparent for combined optical-conductance sensing. The resulting pores are characterized individually using both conductance measurements, employing a microcapillary electrochemical setup, and electron microscopy. Proof-of-concept experiments to sense charged polystyrene particles as they are electrophoretically driven through a single diamond pore are performed, and the impact of this new pore material on particle translocation is explored. As a result, these findings reveal the potential of diamond as a platform for pore-based sensing technologies and pave the way for the fabrication of single nanopores which span the entirety of a diamond membrane.
Performance studies of atomic layer deposited microchannel plate electron multipliers
Microchannel plate (MCP) photon counting, event timing, imaging detectors have found wide use in astronomical, remote sensing, and biological imaging applications. Novel MCP technology using borosilicate glass microcapillary array substrates functionalized by the application of resistive and secondary emissive layers using atomic layer deposition (ALD) techniques has the potential to outperform traditional MCP technology. Using ALD techniques to functionalize the MCPs allow customization of parameters like gain and resistance independently from the glass substrate. Borosilicate substrates have many advantages over traditional micro-capillary arrays, including low radioactive content, higher open area ratios, low outgassing, and high operational stability. These ALD MCPs can be manufactured in large areas (400 cm 2 ) providing a unique solution for many timing/imaging applications. ALD MCPs can withstand the processing temperatures required for high temperature deposition of III-V materials, such as Gallium Nitride, for UV photocathodes with high quantum efficiencies (QE) in the Near-UV (similar to 100-380 nm). We present the effects of different ALD configurations on the gain (magnitude and uniformity), resistance, imaging, background and detection efficiency, and how these parameters change during lifetime testing. Here, we also present the QE of ALD MCPs and various QE enhancement techniques.
2D perovskite-based high spatial resolution X-ray detectors
Abstract X-ray radiography is the most widely used imaging technique with applications encompassing medical and industrial imaging, homeland security, and materials research. Although a significant amount of research and development has gone into improving the spatial resolution of the current state-of-the-art indirect X-ray detectors, it is still limited by the detector thickness and microcolumnar structure quality. This paper demonstrates high spatial resolution X-ray imaging with solution-processable two-dimensional hybrid perovskite single-crystal scintillators grown inside microcapillary channels as small as 20 µm. These highly scalable non-hygroscopic detectors demonstrate excellent spatial resolution similar to the direct X-ray detectors. X-ray imaging results of a camera constructed using this scintillator show Modulation Transfer Function values significantly better than the current state-of-the-art X-ray detectors. These structured detectors open up a new era of low-cost large-area ultrahigh spatial resolution high frame rate X-ray imaging with numerous applications.
Non-Newtonian flow of an ultralow-melting chalcogenide liquid in strongly confined geometry
The flow of high-viscosity liquids inside micrometer-size holes can be substantially different from the flow in the bulk, non-confined state of the same liquid. Such non-Newtonian behavior can be employed to generate structural anisotropy in the frozen-in liquid, i.e., in the glassy state. Here, we report on the observation of non-Newtonian flow of an ultralow melting chalcogenide glass inside a silica microcapillary, leading to a strong deviation of the shear viscosity from its value in the bulk material. In particular, we experimentally show that the viscosity is radius-dependent, which is a clear indication that the microscopic rearrangement of the glass network needs to be considered if the lateral confinement falls below a certain limit. The experiments have been conducted using pressure-assisted melt filling, which provides access to the rheological properties of high-viscosity melt flow under previously inaccessible experimental conditions. The resulting flow-induced structural anisotropy can pave the way towards integration of anisotropic glasses inside hybrid photonic waveguides.
Dielectric measurements of nanoliter liquids with a photonic crystal resonator at terahertz frequencies
We present a highly sensitive technique for determining the complex permittivity of nanoliter liquid samples in the terahertz band based on a photonic crystal resonator and microcapillary. Liquids are characterized by using a capillary tube to introduce a ∼4 nl liquid sample into the electromagnetic field of a resonant mode confined by an L3 resonant cavity in a high-resistivity silicon photonic crystal slab. Monitoring the perturbation of the resonant frequency and unloaded Q-factor of the resonant mode at 100 GHz and ∼5800, respectively, allows a sample's permittivity to be calculated. An analytical model describing the system response based on perturbation theory and quasi-static analysis of the electric field within the capillary is also presented and found to agree well with FEM simulations and experimental measurements of ethanol-water mixtures of various concentrations for low to moderate loss tangents of the liquid samples. We demonstrate the utility of this approach by measuring the complex permittivity of several bioliquids, including suspensions of red and white blood cells. These results represent a step towards a lab-on-a-chip device for the analysis of extremely small quantities of biological, toxic, explosive, and other liquid types at terahertz frequencies.
Fabrication of microchannels in fused silica using femtosecond Bessel beams
Extended birefringent waveguiding microchannels up to 15 mm long were created inside fused silica by single-pulse irradiation with femtosecond Bessel beams. The birefringent refractive index change of 2–4 × 10{sup −4} is attributed to residual mechanical stress. The microchannels were chemically etched in KOH solution to produce 15 mm long microcapillaries with smooth walls and a high aspect ratio of 1:250. Bessel beams provide higher speed of material processing compared to conventional multipulse femtosecond laser micromachining techniques and permit simple control of the optical axis direction of the birefringent waveguides, which is important for practical applications [Corrielli et al., “Rotated waveplates in integrated waveguide optics,” Nat. Commun. 5, 4249 (2014)].
Femtosecond-laser fabrication of cyclic structures in the bulk of transparent dielectrics
We report the results of the experiments on developing precision micromachining technology, obtained under the conditions of focusing the pulses of a femtosecond (FS) laser into the volume of a transparent material, which is important, particularly, in the processing of biomaterials in ophthalmology. The implementation conditions and some characteristic features of the special regime of micromachining are determined, when at a definite relation between the sample scanning velocity and the repetition rate of FS pulses the region, destroyed by the laser radiation, is shifted along the optical axis towards the objective and back, forming cyclic patterns inside the sample. It is supposed that the main causes of the damage region shift are the induced modification of the refractive index and the reduction of the damage threshold due to the change in the material density and structure in the microscopic domain, adjacent to the boundary of the cavity produced by the previous pulse. The results of the performed study with the above regime taken into account were used in the technology of precision cutting of crystals, glasses and polymers. The best quality of the cut surface is achieved under the conditions, eliminating the appearance of the cyclic regime. In the samples of polycarbonate, polymethyl methacrylate and fused silica the cylindrical cavities were obtained with the aspect ratio higher than 200, directed along the laser beam, and microcapillaries with the diameter 1 – 2 μm in the direction, perpendicular to this beam. (interaction of laser radiation with matter)
Atomic layer deposition of alternative glass microchannel plates
The technique of atomic layer deposition (ALD) has enabled the development of alternative glass microchannel plates (MCPs) with independently tunable resistive and emissive layers, resulting in excellent thickness uniformity across the large area (20 × 20 cm), high aspect ratio (60:1 L/d) glass substrates. Furthermore, the use of ALD to deposit functional layers allows the optimal substrate material to be selected, such as borosilicate glass, which has many benefits compared to the lead-oxide glass used in conventional MCPs, including increased stability and lifetime, low background noise, mechanical robustness, and larger area (at present up to 400 cm{sup 2}). Resistively stable, high gain MCPs are demonstrated due to the deposition of uniform ALD resistive and emissive layers on alternative glass microcapillary substrates. The MCP performance characteristics reported include increased stability and lifetime, low background noise (0.04 events cm{sup −2} s{sup −1}), and low gain variation (±5%)
Production of microchannel plates using nano-scale additive manufacturing
Microchannel plate (MCP) detectors have been the workhorse detector for many applications, including space borne ultra-violet imaging and spectrographic instruments. Recent advances in additive manufacturing (AM) have enabled fabrication of complex structures with nano-scale resolution facilitating the production of highly customizable MCPs. Using AM to produce MCPs potentially has many advantages over traditional fused glass substrates, including better material control (e.g., more robust glasses or ceramics), better control of microscopic features (e.g., unique pore geometries to improve performance), and better control of macroscopic features (e.g., printing precision curved surfaces for focal plane matching). Through a collaboration with industry, national laboratory, and university partners, small format microcapillary array substrates were produced using a standard polymer photoresin. In conclusion, these substrates were functionalized using atomic layer deposition and their performance was compared to current state-of-the-art Pb-glass and borosilicate-glass MCPs.
Development of coatings to control electroosmosis in zero gravity electrophoresis
A major problem confronting the operation of free fluid electrophoresis in zero gravity is the control of electrokinetic phenomena and, in particular, electroosmosis. Due to the severity of counter flow, as a result of electroosmosis, the electrical potential developed at the surface of shear must be maintained at near, or as close to, zero millivolts as possible. Based upon this investigation, it has been found that the amount of bound water or the degree of hydroxylation plays a major role in the control of this phenomena. Of necessity, factors, such as adhesion, biocompatibility, protein adsorption, and insolubility were considered in this investigation because of the long buffer-coating exposure times required by present space operations. Based upon tests employing microcapillary electrophoresis, it has been found that gamma amino propyl trihydroxysilane produced a coating which provides the lowest potential (minus 3.86 mv) at the surface of shear between the stationary and mobile layers. This coating has been soaked in both borate and saline buffers, up to three months, in a pH range of 6.5 to 10 without deleterious effects or a change in its ability to control electrokinetic effects.
Development of coatings to control electroosmosis in zero gravity electrophoresis
A major problem confronting the operation of free fluid electrophoresis in zero gravity is the control of electrokinetic phenomena and, in particular, electroosmosis. Due to the severity of counter flow as a result of electroosmosis, the electrical potential developed at the surface of shear must be maintained at near, or as close, to zero millivolts as possible. Based upon this investigation, it has been found that the amount of bound water or the degree of hydroxylation plays a major role in the control of this phenomenon. Based upon tests employing microcapillary electrophoresis, it has been found that gamma amino propyl trihydroxysilane produced a coating which provides the lowest potential (about 3.86 mV) at the surface of shear between the stationary and mobile layers.
Modelling of capillary optics as a focussing hard X-ray concentrator
The development of glass microcapillary arrays by Kumakhov and co-workers in the Soviet Union suggests that it is possible to construct novel devices for concentrating and focussing X-ray beams. Hypothetical focussing concentrators made up of capillary arrays have been configured to operate over a broad range of X-ray energy and its characteristics have been studied with a Monte Carlo ray tracing code. These modeling results indicate that the concentrators would have significant effective area up to 100 keV while their dimensions are similar to conventional grazing incidence telescopes that operate in the soft X-ray band.