Search NASA⌕ Search

SEARCH · Search NASA

Results for “microdosimetry”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

SU-G-TeP3-04: Evaluation of the Dose Enhancement with Gold Nanoparticle in Microdosimetry Level Using the Geant4-DNA Toolkit

Purpose: This study investigated the dose enhancement effect of using gold nanoparticles (GNP) as radiation sensitizers radiated by different photon beam energies. Microdosimetry of photon-irradiated GNP was determined by the Geant4-DNA process in the DNA scale. Methods: Monte Carlo simulation was conducted using the Geant4 toolkit (ver. 10.2). A GNP with different sizes (30, 50, and 100nm diameter sphere) and a DNA were placed in a water cube (1µm{sup 3}). The GNP was irradiated by photon beams with different energies (50, 100, and 150keV) and produced secondary electrons to increase the dose to the DNA. Energy depositions were calculated for both with and without GNP and to investigate the dose enhancement effect at the DNA. The distance between the GNP and DNA was varied to optimize the best GNP position to the DNA. The photon beam source was set to 200nm from the GNP in each simulation. Results: It is found that GNP had a dose enhancement effect on kV photon radiations. For Monte Carlo results on different GNP sizes, distances between the GNP and DNA, and photon beam energies, enhancement ratio was found increasing as GNP size increased. The distance between the GNP and DNA affected the result that as distance increased while the dose enhancement ratio decreased. However, the effect of changing distance was not as significant as varying the GNP size. In addition, increasing the photon beam energy also increased the dose enhancement ratio. The largest dose enhancement ratio was found to be 3.5, when the GNP (100nm diameter) irradiated by the 150keV photon beam was set to 80nm from the DNA. Conclusion: Dose enhancement was determined in the DNA with GNP in the microdosimetry scale. It is concluded that the dose enhancement varied with the photon beam energy, GNP size and distance between the GNP and DNA.

60 APPLIED LIFE SCIENCES↗

TU-AB-BRC-02: Accuracy Evaluation of GPU-Based OpenCL Carbon Monte Carlo Package (goCMC) in Biological Dose and Microdosimetry in Comparison to FLUKA Simulations

Purpose: One of the most accurate methods for radiation transport is Monte Carlo (MC) simulation. Long computation time prevents its wide applications in clinic. We have recently developed a fast MC code for carbon ion therapy called GPU-based OpenCL Carbon Monte Carlo (goCMC) and its accuracy in physical dose has been established. Since radiobiology is an indispensible aspect of carbon ion therapy, this study evaluates accuracy of goCMC in biological dose and microdosimetry by benchmarking it with FLUKA. Methods: We performed simulations of a carbon pencil beam with 150, 300 and 450 MeV/u in a homogeneous water phantom using goCMC and FLUKA. Dose and energy spectra for primary and secondary ions on the central beam axis were recorded. Repair-misrepair-fixation model was employed to calculate Relative Biological Effectiveness (RBE). Monte Carlo Damage Simulation (MCDS) tool was used to calculate microdosimetry parameters. Results: Physical dose differences on the central axis were <1.6% of the maximum value. Before the Bragg peak, differences in RBE and RBE-weighted dose were <2% and <1%. At the Bragg peak, the differences were 12.5% caused by small range discrepancy and sensitivity of RBE to beam spectra. Consequently, RBE-weighted dose difference was 11%. Beyond the peak, RBE differences were <20% and primarily caused by differences in the Helium-4 spectrum. However, the RBE-weighted dose agreed within 1% due to the low physical dose. Differences in microdosimetric quantities were small except at the Bragg peak. The simulation time per source particle with FLUKA was 0.08 sec, while goCMC was approximately 1000 times faster. Conclusion: Physical doses computed by FLUKA and goCMC were in good agreement. Although relatively large RBE differences were observed at and beyond the Bragg peak, the RBE-weighted dose differences were considered to be acceptable.

60 APPLIED LIFE SCIENCES↗

Radiobiology, Omics and Microdosimetry of Systemic and Targeted Radiotherapeutics Workshop

The Radiobiology, Omics and Microdosimetry of Systemic and Targeted Radiotherapeutics Workshop fostered engagement across disciplines on critical topics that impact the development of targeted radionuclide therapies, bringing together scientific and medical professionals actively involved in radiotherapeutic design, optimization testing, patient treatment, and clinical trials along with basic science researchers, whose novel techniques have the potential to further our understanding of targeted radionuclide therapy. Discussion of the applications of radiotherapeutics to pediatric and adult, brain, prostate and blood cancers, and metastatic disease allowed scientific research to be presented in the context of real-world medical applications and provided an important backdrop to the basic research performed in computers, laboratories, and animal facilities. The workshop format, presentations, and panel discussions were designed to consider a holistic approach to the development of systemic and targeted radiotherapies, integrating radiobiology and microdosimetry, biological assessments on the microscale, and physiologically relevant models of tumor and tissue microenvironments. Important needs highlighted in the workshop include better models to assess the biological effects of radionuclide therapy, novel strategies to target radiotherapeutics to disease sites with high specificity, and new dosimetry techniques that address the importance of tumor microenvironments.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Development of a randomized 3D cell model for Monte Carlo microdosimetry simulations

Purpose: The objective of the current work was to develop an algorithm for growing a macroscopic tumor volume from individual randomized quasi-realistic cells. The major physical and chemical components of the cell need to be modeled. It is intended to import the tumor volume into GEANT4 (and potentially other Monte Carlo packages) to simulate ionization events within the cell regions. Methods: A MATLAB Copyright-Sign code was developed to produce a tumor coordinate system consisting of individual ellipsoidal cells randomized in their spatial coordinates, sizes, and rotations. An eigenvalue method using a mathematical equation to represent individual cells was used to detect overlapping cells. GEANT4 code was then developed to import the coordinate system into GEANT4 and populate it with individual cells of varying sizes and composed of the membrane, cytoplasm, reticulum, nucleus, and nucleolus. Each region is composed of chemically realistic materials. Results: The in-house developed MATLAB Copyright-Sign code was able to grow semi-realistic cell distributions ({approx}2 Multiplication-Sign 10{sup 8} cells in 1 cm{sup 3}) in under 36 h. The cell distribution can be used in any number of Monte Carlo particle tracking toolkits including GEANT4, which has been demonstrated in this work. Conclusions: Using the cell distribution and GEANT4, the authors were able to simulate ionization events in the individual cell components resulting from 80 keV gamma radiation (the code is applicable to other particles and a wide range of energies). This virtual microdosimetry tool will allow for a more complete picture of cell damage to be developed.

61 RADIATION PROTECTION AND DOSIMETRY↗

Microdosimetry of proton and carbon ions

Purpose: To investigate microdosimetry properties of 160 MeV/u protons and 290 MeV/u{sup 12}C ion beams in small volumes of diameters 10–100 nm. Methods: Energy distributions of primary particles and nuclear fragments in the beams were calculated from simulations with the general purpose code SHIELD-HIT, while energy depositions by monoenergetic ions in nanometer volumes were obtained from the event-by-event Monte Carlo track structure ion code PITS99 coupled with the electron track structure code KURBUC. Results: The results are presented for frequencies of energy depositions in cylindrical targets of diameters 10–100 nm, dose distributionsyd(y) in lineal energy y, and dose-mean lineal energies y{sup ¯}{sub D}. For monoenergetic ions, the y{sup ¯}{sub D} was found to increase with an increasing target size for high-linear energy transfer (LET) ions, but decrease with an increasing target size for low-LET ions. Compared to the depth dose profile of the ion beams, the maximum of the y{sup ¯}{sub D} depth profile for the 160 MeV proton beam was located at ∼0.5 cm behind the Bragg peak maximum, while the y{sup ¯}{sub D} peak of the 290 MeV/u {sup 12}C beam coincided well with the peak of the absorbed dose profile. Differences between the y{sup ¯}{sub D} and dose-averaged linear energy transfer (LET{sub D}) were large in the proton beam for both target volumes studied, and in the {sup 12}C beam for the 10 nm diameter cylindrical volumes. The y{sup ¯}{sub D} determined for 100 nm diameter cylindrical volumes in the {sup 12}C beam was approximately equal to the LET{sub D}. The contributions from secondary particles to the y{sup ¯}{sub D} of the beams are presented, including the contributions from secondary protons in the proton beam and from fragments with atomic number Z = 1–6 in the {sup 12}C beam. Conclusions: The present investigation provides an insight into differences in energy depositions in subcellular-size volumes when irradiated by proton and carbon ion beams. The results are useful for characterizing ion beams of practical importance for biophysical modeling of radiation-induced DNA damage response and repair in the depth profiles of protons and carbon ions used in radiotherapy.

07 ISOTOPE AND RADIATION SOURCES↗

Track-structure investigations: A supplement to microdosimetry

We conceived and developed an experimental apparatus able to measure the track structure (the spatial distribution of the points of ionizing collisions) of light ions, allowing the investigation of the track-core and penumbra regions separately. The device is based on single-electron counting technique, and simulates a target volume V of about 20 nm in diameter that can be moved with respect to a narrow primary particle beam, allowing the measurement of the ionization-cluster-size distribution as a function of the impact parameter. The experimental set up is mounted at the Tandem-Alpi LNL particle accelerator complex. The goal of the experiment is to investigate the formation of ionization-cluster-size distributions caused in a nanometre-sized volume by different light ions of medical interest (protons, lithium ions and carbon ions), when penetrating through or passing by the target volume at a specified distance.

43 PARTICLE ACCELERATORS↗

Spectroscopic properties and radiation damage investigation of a diamond based Schottky diode for ion-beam therapy microdosimetry

In this work, a detailed analysis of the properties of a novel microdosimeter based on a synthetic single crystal diamond is reported. Focused ion microbeams were used to investigate the device spectropscopic properties as well as the induced radiation damage effects. A diamond based Schottky diode was fabricated by chemical vapor deposition with a very thin detecting region, about 400 nm thick (approximately 1.4 μm water equivalent thickness), corresponding to the typical size in microdosimetric measurements. A 200 × 200 μm{sup 2} square metallic contact was patterned on the diamond surface by standard photolithography to define the sensitive area. Experimental measurements were carried out at the Ruder Boškovic′ Institute microbeam facility using 4 MeV carbon and 5 MeV silicon ions. Ion beam induced charge maps were employed to characterize the microdosimeter response in terms of its charge collection properties. A stable response with no evidence of polarization or memory effects was observed up to the maximum investigated ion beam flux of about 1.7 × 10{sup 9} ions·cm{sup −2}·s{sup −1}. A homogeneity of the response about 6% was found over the sensitive region with a well-defined confinement of the response within the active area. Tests of the radiation damage effect were performed by selectively irradiating small areas of the device with different ion fluences, up to about 10{sup 12} ions/cm{sup 2}. An exponential decrease of the charge collection efficiency was observed with a characteristic decay constant of about 4.8 MGy and 1 MGy for C and Si ions, respectively. The experimental data were analyzed by means of GEANT4 Monte Carlo simulations. A direct correlation between the diamond damaging effect and the Non Ionizing Energy Loss (NIEL) fraction was found. In particular, an exponential decay of the charge collection efficiency with an exponential decay as a function of NIEL is observed, with a characteristic constant of about 9.3 kGy-NIEL for both carbon and silicon ions.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

SU-E-T-380: Particle Microdosimetry Study Based On 3D-Cylindrical Silicon Radiaton Detectors

Purpose: A new design of a solid-state-microdetector based on silicon 3D microfabrication and its performance to characterise Lineal energy, Specific Energy, dose, LET and other microdosimetric variables required for modelling particle relative biological effectiveness (RBE) is presented. Methods: A microdosimeter formed by a matrix of independent sensors with well-defined micrometric cylindrical shape and with a volume similar to those of cellular dimensions is used to measure microdosimetric variables. Each sensor measures the radiation deposited energy which, divided by the mean cord length of the sensors, provides us with the Linear Energy (y) of the radiation as well as its energy distribution, and frequencymean. Starting from the these distributions in different points of a proton beam, we generate biophysical data (e.g. Linear Energy Transfer (LET), Specific Energy (z), etc…) needed for relative biological effectiveness (RBE) calculations radiation effect models used in particle radiotherapy treatment planning. In addition, a Tissue Equivalent Proportional Counter (TEPC) will be used as baseline to calibrate the “y” magnitude of the microdosimeter unit-cells. Results: The experimental measurements will soon be carried out at the Perelman Center for Advanced Medicine (University of Pennsylvania), which provides proton beam for clinical research proposals. The results of distributions measured of the microdosimetric variables from the first tests developed in the proton facility will be presented and compared with Monte Carlo simulations using the Geant4 code. Conclusion: The use of 3D microdosimeters such as the one presented here will enhance the accuracy of RBE calculations normally affected by the inherent uncertainty of monte carlo simulations due to the approximation of material composition and energy dependent physical laws involved in such calculations. The effect of such approximations will be quatified by comparison with absolute measurement of radiation quality parameters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Comparison of GEANT4 very low energy cross section models with experimental data in water

Purpose: The GEANT4 general-purpose Monte Carlo simulation toolkit is able to simulate physical interaction processes of electrons, hydrogen and helium atoms with charge states (H{sup 0}, H{sup +}) and (He{sup 0}, He{sup +}, He{sup 2+}), respectively, in liquid water, the main component of biological systems, down to the electron volt regime and the submicrometer scale, providing GEANT4 users with the so-called ''GEANT4-DNA'' physics models suitable for microdosimetry simulation applications. The corresponding software has been recently re-engineered in order to provide GEANT4 users with a coherent and unique approach to the simulation of electromagnetic interactions within the GEANT4 toolkit framework (since GEANT4 version 9.3 beta). This work presents a quantitative comparison of these physics models with a collection of experimental data in water collected from the literature. Methods: An evaluation of the closeness between the total and differential cross section models available in the GEANT4 toolkit for microdosimetry and experimental reference data is performed using a dedicated statistical toolkit that includes the Kolmogorov-Smirnov statistical test. The authors used experimental data acquired in water vapor as direct measurements in the liquid phase are not yet available in the literature. Comparisons with several recommendations are also presented. Results: The authors have assessed the compatibility of experimental data with GEANT4 microdosimetry models by means of quantitative methods. The results show that microdosimetric measurements in liquid water are necessary to assess quantitatively the validity of the software implementation for the liquid water phase. Nevertheless, a comparison with existing experimental data in water vapor provides a qualitative appreciation of the plausibility of the simulation models. The existing reference data themselves should undergo a critical interpretation and selection, as some of the series exhibit significant deviations from each other. Conclusions: The GEANT4-DNA physics models available in the GEANT4 toolkit have been compared in this article to available experimental data in the water vapor phase as well as to several published recommendations on the mass stopping power. These models represent a first step in the extension of the GEANT4 Monte Carlo toolkit to the simulation of biological effects of ionizing radiation.

61 RADIATION PROTECTION AND DOSIMETRY↗

SU-E-T-78: Comparison of Dose-Averaged Linear Energy Transfer Calculation Methods Used in Monte Carlo Simulations of Clinical Proton Beams

Purpose: To evaluate the differences in dose-averaged linear energy transfer (LETd) maps calculated in water by means of different strategies found in the literature in proton therapy Monte Carlo simulations and to compare their values with dose-mean lineal energy microdosimetry calculations. Methods: The Geant4 toolkit (version 9.6.2) was used. Dose and LETd maps in water were scored for primary protons with cylindrical voxels defined around the beam axis. Three LETd calculation methods were implemented. First, the LETd values were computed by calculating the unrestricted linear energy transfer (LET) associated to each single step weighted by the energy deposition (including delta-rays) along the step. Second, the LETd was obtained for each voxel by computing the LET along all the steps simulated for each proton track within the voxel, weighted by the energy deposition of those steps. Third, the LETd was scored as the quotient between the second momentum of the LET distribution, calculated per proton track, over the first momentum. These calculations were made with various voxel thicknesses (0.2 – 2.0 mm) for a 160 MeV proton beamlet and spread-out Bragg Peaks (SOBP). The dose-mean lineal energy was calculated in a uniformly-irradiated water sphere, 0.005 mm radius. Results: The value of the LETd changed systematically with the voxel thickness due to delta-ray emission and the enlargement of the LET distribution spread, especially at shallow depths. Differences of up to a factor 1.8 were found at the depth of maximum dose, leading to similar differences at the central and distal depths of the SOBPs. The third LETd calculation method gave better agreement with microdosimetry calculations around the Bragg Peak. Conclusion: Significant differences were found between LETd map Monte Carlo calculations due to both the calculation strategy and the voxel thickness used. This could have a significant impact in radiobiologically-optimized proton therapy treatments.

07 ISOTOPE AND RADIATION SOURCES↗

Quantitative single-particle digital autoradiography with α-particle emitters for targeted radionuclide therapy using the iQID camera

Purpose: Alpha-emitting radionuclides exhibit a potential advantage for cancer treatments because they release large amounts of ionizing energy over a few cell diameters (50–80 μm), causing localized, irreparable double-strand DNA breaks that lead to cell death. Radioimmunotherapy (RIT) approaches using monoclonal antibodies labeled with α emitters may thus inactivate targeted cells with minimal radiation damage to surrounding tissues. Tools are needed to visualize and quantify the radioactivity distribution and absorbed doses to targeted and nontargeted cells for accurate dosimetry of all treatment regimens utilizing α particles, including RIT and others (e.g., Ra-223), especially for organs and tumors with heterogeneous radionuclide distributions. The aim of this study was to evaluate and characterize a novel single-particle digital autoradiography imager, the ionizing-radiation quantum imaging detector (iQID) camera, for use in α-RIT experiments. Methods: The iQID camera is a scintillator-based radiation detection system that images and identifies charged-particle and gamma-ray/x-ray emissions spatially and temporally on an event-by-event basis. It employs CCD-CMOS cameras and high-performance computing hardware for real-time imaging and activity quantification of tissue sections, approaching cellular resolutions. In this work, the authors evaluated its characteristics for α-particle imaging, including measurements of intrinsic detector spatial resolutions and background count rates at various detector configurations and quantification of activity distributions. The technique was assessed for quantitative imaging of astatine-211 ({sup 211}At) activity distributions in cryosections of murine and canine tissue samples. Results: The highest spatial resolution was measured at ∼20 μm full width at half maximum and the α-particle background was measured at a rate as low as (2.6 ± 0.5) × 10{sup −4} cpm/cm{sup 2} (40 mm diameter detector area). Simultaneous imaging of multiple tissue sections was performed using a large-area iQID configuration (ø 11.5 cm). Estimation of the {sup 211}At activity distribution was demonstrated at mBq/μg-levels. Conclusions: Single-particle digital autoradiography of α emitters has advantages over traditional film-based autoradiographic techniques that use phosphor screens, in terms of spatial resolution, sensitivity, and activity quantification capability. The system features and characterization results presented in this study show that the iQID is a promising technology for microdosimetry, because it provides necessary information for interpreting alpha-RIT outcomes and for predicting the therapeutic efficacy of cell-targeted approaches using α emitters.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Confocal Microscopy for Modeling Electron Microbeam Irradiation of Skin

For radiation exposures employing targeted sources such as particle microbeams, the deposition of energy and dose will depend on the spatial heterogeneity of the spample. Although cell structural variations are relatively minor for two-dimensional cell cultures, they can vary significantly for fully differential tissues. Employing high-resolution confocal microscopy, we have determined the spatial distribution, size, and shape of epidermal kerantinocyte nuclei for the full-thickness EpiDerm skin model (MatTek, Ashland, VA). Application of these data to claculate the microdosimetry and microdistribution of energy deposition by an electron microbeam is discussed.

59 BASIC BIOLOGICAL SCIENCES↗

Localized Dose Enhancement to Tumor Blood Vessel Endothelial Cells via Megavoltage X-rays and Targeted Gold Nanoparticles: New Potential for External Beam Radiotherapy

Purpose: Tumor endothelial cell damage during radiation therapy may contribute significantly to tumor eradication and treatment efficacy. Gold nanoparticles (AuNPs) delivered preferentially to the walls of tumor blood vessels produce low-energy, short-range photoelectrons during external beam radiotherapy, boosting dose to the tumor microvasculature. In this study dosimetry at the single-cell level is used to estimate the anticipated AuNP-mediated dose enhancement to tumor endothelial cells during 6-MV X-ray irradiation. Methods and Materials: Endothelial cells are modeled as thin slabs with 100-nm-diameter AuNPs attached within the blood vessel. The number of photoelectrons emitted per AuNP per gray of X-rays is computed at multiple points along the external beam central axis by use of a Monte Carlo-generated energy fluence spectrum. The energy deposited from AuNP emissions to the endothelium is calculated based on an analytic method incorporating the energy-loss formula of Cole. The endothelial dose enhancement factor (EDEF) is the ratio of the overall (externally plus internally generated) dose to endothelial cells in the presence of AuNPs to the dose without AuNPs (from the external beam only). Results: At 20-cm depth, the EDEF is 1.7 (70% dose increase) for an intravascular AuNP concentration of 30 mg/g. Most of this dose enhancement arises from the low-energy (approximately 100 keV) portion of the linear accelerator X-ray spectrum. Furthermore, for AuNP concentrations ranging from 7 to 140 mg/g, EDEF values of 1.2 to 4.4 (20-340% dose increase) are calculated. Conclusions: In contrast to calculations assuming that AuNPs distributed homogeneously throughout the target volume (macrodosimetry), our cellular microdosimetry calculations predict a major dose enhancement to tumor microvasculature from conventional linear accelerator X-rays. This effect may enable the delivery of ablative therapeutic doses to these sensitive microstructures while maintaining established dose constraints for the organs at risk.

62 RADIOLOGY AND NUCLEAR MEDICINE↗

Silicon-based three-dimensional microstructures for radiation dosimetry in hadrontherapy

In this work, we propose a solid-state-detector for use in radiation microdosimetry. This device improves the performance of existing dosimeters using customized 3D-cylindrical microstructures etched inside silicon. The microdosimeter consists of an array of micro-sensors that have 3D-cylindrical electrodes of 15 μm diameter and a depth of 5 μm within a silicon membrane, resulting in a well-defined micrometric radiation sensitive volume. These microdetectors have been characterized using an {sup 241}Am source to assess their performance as radiation detectors in a high-LET environment. This letter demonstrates the capability of this microdetector to be used to measure dose and LET in hadrontherapy centers for treatment plan verification as part of their patient-specific quality control program.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

RBE estimation of proton radiation fields using a {Delta}E-E telescope

A new monolithic silicon {Delta}E-E telescope was evaluated in unmodulated and modulated 100 MeV proton beams used for hadron therapy. Compared to a classical microdosimetry detector, which provides one-dimensional information on lineal energy of charged particles, this detector system provides two-dimensional information on lineal energy and particle energy based on energy depositions, collected in coincidence, within the {Delta}E and E stages of the detector. The authors investigated the possibility to use the information obtained with the {Delta}E-E telescope to determine the relative biological effectiveness (RBE) at defined locations within the proton Bragg peak and spread-out Bragg peak (SOBP). An RBE matrix based on the established in vitro V79 cell survival data was developed to link the output of the device directly to RBE({alpha}), the RBE in the low-dose limit, at various depths in a homogeneous polystyrene phantom. In the SOBP of a 100 MeV proton beam, the RBE({alpha}) increased from 4.04 proximal to the SOBP to a maximum value of 5.4 at the distal edge. The {Delta}E-E telescope, with its high spatial resolution, has potential applications to biologically weighted hadron treatment planning as it provides a compact and portable means for estimating the RBE in rapidly changing hadron radiation fields within phantoms.

46 INSTRUMENTATION RELATED TO NUCLEAR SCIENCE AND ↗

Microdosimetric study on influence of low energy photons on relative biological effectiveness under therapeutic conditions using 6 MV linac

Purpose: Microdosimetry has been developed for the evaluation of radiation quality, and single-event dose-mean lineal energy y{sub D} is well-used to represent the radiation quality. In this study, the changes of the relative biological effectiveness (RBE) values under the therapeutic conditions using a 6 MV linac were investigated with a microdosimetric method. Methods: The y{sub D} values under the various irradiation conditions for x-rays from a 6 MV linac were measured with a tissue-equivalent proportional counter (TEPC) at an extremely low dose rate of a few tens of {mu}Gy/min by decreasing the gun grid voltage of the linac. According to the microdosimetric kinetic model (MK model), the RBE{sub MK} values for cell killing of the human salivary gland (HSG) tumor cells can be derived if the y{sub D} values are obtained from TEPC measurements. The Monte Carlo code GEANT4 was also used to calculate the photon energy distributions and to investigate the changes of the y{sub D} values under the various conditions. Results: The changes of the y{sub D} values were less than approximately 10% when the field size and the depth in a phantom varied. However, in the measurements perpendicular to a central beam axis, large changes were observed between the y{sub D} values inside the field and those outside the field. The maximum increase of approximately 50% in the y{sub D} value outside the field was obtained compared with those inside the field. The GEANT4 calculations showed that there existed a large relative number of low energy photons outside of the field as compared with inside of the field. The percentages of the photon fluences below 200 keV outside the field were approximately 40% against approximately 8% inside the field. By using the MK model, the field size and the depth dependence of the RBE{sub MK} values were less than approximately 2% inside the field. However, the RBE{sub MK} values outside the field were 6.6% higher than those inside the field. Conclusions: The increase of the RBE{sub MK} values by 6.6% outside the field was observed. This increase is caused by the change of the photon energy distributions, especially the increase of the relative number of low energy photons outside the field.

43 PARTICLE ACCELERATORS↗