Search NASA⌕ Search

SEARCH · Search NASA

Results for “microelectrode array”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Microelectrode Arrays for Electrochemical Cycling of Individual Battery Particles

The electrochemical characterization of battery materials is usually performed on porous electrodes containing conductive additives, binders, and ensembles of redox-active particles at densities as high as 10 15 cm –3 . These complex structures often obscure individual battery particles’ intrinsic properties, hindering insights into the fundamentals of battery electrochemistry. To address this challenge, we developed microelectrode arrays to enable the charge and discharge of individual battery particles in liquid electrolytes. In this Methods and Protocols paper, we describe the fabrication of the microelectrode array chips, the assembly of particles onto microelectrodes, and the different types of electrochemical techniques that can be used, including galvanostatic cycling, cyclic voltammetry, potentiostatic intermittent titration, and electrochemical impedance spectroscopy. We use micron-sized lithium cobalt oxide as a model system to showcase the reliability and versatility of single-particle electrochemical experiments enabled by our microelectrode array. In conclusion, we aim to provide a detailed description to promote future uses of microelectrode arrays in fundamental research of batteries and other electrochemical systems.

25 ENERGY STORAGE↗

Cylindrical microelectrode array for neural stimulation and recording

A cylindrical microelectrode array having an elongated cylindrical core, and a multilayer structure conformally folded around and affixed to the cylindrical core so as to extend between opposite ends of the core. The multilayer structure has integrated sections including an electrode section with electrodes exposed through electrically insulating layers, a connector section with conductive bond pads for interfacing with external electronics, and a cable section with conductive traces encapsulated in electrically insulating layers and which connect between the electrodes and their corresponding bond pads. The array may be fabricated using a planar multilayer structure having the electrode, connector, and cable sections, and conformally folding the multilayer structure around and affixing to the cylindrical core. The cable section in particular may be conformally coiled around and affixed to the cylindrical core so that the electrical conduits helically extend between the connector and electrode sections.

Shah, Kedar G.↗

Automated Label‐Free Assay for Viral Detection and Inhibitor Screening via Biomembrane‐Functionalized Microelectrode Arrays

Most virus infection assays have indirect readout such as virus number following entry (e.g., PCR, cell lysis). While effective, these technologies are labor‐intensive, require specialized environments (e.g., sterile or RNA‐free), and detect later‐stage viral events like lysis or cell death, lacking sensitivity to early fusion events. To address these limitations, we present biologically relevant 2D membrane materials, host‐cell‐derived supported lipid bilayers (hcd‐SLBs), integrated with organic microelectrode arrays (OMEAs) for detection of severe acute respiratory syndrome coronavirus 2 (SARS‐CoV‐2) fusion. By overexpressing angiotensin‐converting enzyme 2 (ACE2) receptors on the native membranes, the platform functions as a viral sensor capable of detecting virus pseudo particles (VPPs) through the late pathway. Additionally, hcd‐SLBs extracted from human lung epithelium expressing native ACE2 detect fusion events through the early pathway. The platform's utility as a drug‐screening tool is demonstrated by testing antibodies targeting either the ACE2 on the host membrane or the viral spike (S) proteins. To enhance the throughput, microfluidics are integrated for automation and OMEAs are incorporated within each channel, miniaturizing the testing units. This system supports high‐throughput data generation, automation, and scalability, providing an efficient platform for viral fusion detection that advances the study of pathogen‐host interactions and accelerates antiviral drug discovery.

Biology↗

Microelectrode Arrays Measure Blocking of Voltage-Gated Calcium Ion Channels on Supported Lipid Bilayers Derived from Primary Neurons

Drug studies targeting neuronal ion channels are crucial to understand neuronal function and develop therapies for neurological diseases. The traditional method to study neuronal ion-channel activities heavily relies on the whole-cell patch clamp as the industry standard. However, this technique is both technically challenging and labour-intensive, while involving the complexity of keeping cells alive with low throughput. Therefore, the shortcomings are limiting the efficiency of ion-channel-related neuroscience research and drug testing. Here, this work reports a new system of integrating neuron membranes with organic microelectrode arrays (OMEAs) for ion-channel-related drug studies. This work demonstrates that the supported lipid bilayers (SLBs) derived from both neuron-like (neuroblastoma) cells and primary neurons are integrated with OMEAs for the first time. The increased expression of voltage-gated calcium (CaV) ion channels on differentiated SH-SY5Y SLBs compared to non-differentiated ones is sensed electrically. Also, dose-response of the CaV ion-channel blocking effect on primary cortical neuronal SLBs from rats is monitored. The dose range causing ion channel blocking is comparable to literature. This system overcomes the major challenges from traditional methods (e.g., patch clamp) and showcases an easy-to-test, rapid, ultra-sensitive, cell-free, and high-throughput platform to monitor dose-dependent ion-channel blocking effects on native neuronal membranes.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

System and method for three-dimensional in vitro flexible microelectrode array

The present disclosure relates to a biocompatible, in vitro probe system. The probe system may have a substrate and a culture well supported on the substrate. The culture well defines a three-dimensional volume for containing in vitro cultures of electroactive cells. The probe system has at least one probe subsystem supported on the substrate. The probe subsystem has at least one probe having an array of electrodes, with the probe being disposed within the culture well for in vitro electrically communicating with the electroactive cells. The probe subsystem is adapted to be interfaced to an external instrumentation/recording device.

Soscia, David↗

Electronic structures on swollen hydrogels

This document describes a conformable substrate that includes a hydrogel having adhesion-promoting moieties, said adhesion-promoting moieties comprising one or more catechol groups. The conformable substrate includes an array of microelectrodes bonded to the hydrogel by the adhesion-promoting moieties via the one or more catechol groups. This document also describes a method for transfer printing of an electronic structure to a hydrogel. The method includes the steps of coating a donor substrate with a film of polyacrylic acid, crosslinking the film of polyacrylic acid in a solution comprising divalent ions, patterning a microelectrode array onto the crosslinked film of polyacrylic acid, laminating an adhesive hydrogel substrate onto the donor substrate coated by the crosslinked film of polyacrylic acid comprising the patterned microelectrode array, and separating the crosslinked film of polyacrylic acid from the donor substrate in a monovalent solution.

Bettinger, Christopher J.↗

Effects of Electrical Stimulation on hiPSC-CM Responses to Classic Ion Channel Blockers

Abstract Human induced pluripotent stem cell-derived cardiomyocytes (hiPSC-CMs) hold great potential for personalized cardiac safety prediction, particularly for that of drug-induced proarrhythmia. However, hiPSC-CMs fire spontaneously and the variable beat rates of cardiomyocytes can be a confounding factor that interferes with data interpretation. Controlling beat rates with pacing may reduce batch and assay variations, enable evaluation of rate-dependent drug effects, and facilitate the comparison of results obtained from hiPSC-CMs with those from adult human cardiomyocytes. As electrical stimulation (E-pacing) of hiPSC-CMs has not been validated with high-throughput assays, herein, we compared the responses of hiPSC-CMs exposed with classic cardiac ion channel blockers under spontaneous beating and E-pacing conditions utilizing microelectrode array technology. We found that compared with spontaneously beating hiPSC-CMs, E-pacing: (1) reduced overall assay variabilities, (2) showed limited changes of field potential duration to pacemaker channel block, (3) revealed reverse rate dependence of multiple ion channel blockers on field potential duration, and (4) eliminated the effects of sodium channel block on depolarization spike amplitude and spike slope due to a software error in acquiring depolarization spike at cardiac pacing mode. Microelectrode array optogenetic pacing and current clamp recordings at various stimulation frequencies demonstrated rate-dependent block of sodium channels in hiPSC-CMs as reported in adult cardiomyocytes. In conclusion, pacing enabled more accurate rate- and concentration-dependent drug effect evaluations. Analyzing responses of hiPSC-CMs under both spontaneously beating and rate-controlled conditions may help better assess the effects of test compounds on cardiac electrophysiology and evaluate the value of the hiPSC-CM model.

Wei, Feng↗

Integrating Data From In Vitro New Approach Methodologies for Developmental Neurotoxicity

Abstract In vivo developmental neurotoxicity (DNT) testing is resource intensive and lacks information on cellular processes affected by chemicals. To address this, DNT new approach methodologies (NAMs) are being evaluated, including: the microelectrode array neuronal network formation assay; and high-content imaging to evaluate proliferation, apoptosis, neurite outgrowth, and synaptogenesis. This work addresses 3 hypotheses: (1) a broad screening battery provides a sensitive marker of DNT bioactivity; (2) selective bioactivity (occurring at noncytotoxic concentrations) may indicate functional processes disrupted; and, (3) a subset of endpoints may optimally classify chemicals with in vivo evidence for DNT. The dataset was comprised of 92 chemicals screened in all 57 assay endpoints sourced from publicly available data, including a set of DNT NAM evaluation chemicals with putative positives (53) and negatives (13). The DNT NAM battery provides a sensitive marker of DNT bioactivity, particularly in cytotoxicity and network connectivity parameters. Hierarchical clustering suggested potency (including cytotoxicity) was important for classifying positive chemicals with high sensitivity (93%) but failed to distinguish patterns of disrupted functional processes. In contrast, clustering of selective values revealed informative patterns of differential activity but demonstrated lower sensitivity (74%). The false negatives were associated with several limitations, such as the maximal concentration tested or gaps in the biology captured by the current battery. This work demonstrates that this multi-dimensional assay suite provides a sensitive biomarker for DNT bioactivity, with selective activity providing possible insight into specific functional processes affected by chemical exposure and a basis for further research.

Carstens, Kelly E.↗

Mechanisms of QT prolongation by buprenorphine cannot be explained by direct hERG channel block

Buprenorphine is a μ-opioid receptor (MOR) partial agonist used to manage pain and addiction. QT C prolongation that crosses the 10 msec threshold of regulatory concern was observed at a supratherapeutic dose in two thorough QT studies for the transdermal buprenorphine product BUTRANS®. Because QT C prolongation can be associated with Torsades de Pointes (TdP), a rare but potentially fatal ventricular arrhythmia, these results have led to further investigation of the electrophysiological effects of buprenorphine. Drug-induced QT C prolongation and TdP are most commonly caused by acute inhibition of hERG current (I hERG ) that contribute to the repolarizing phase of the ventricular action potentials (APs). Concomitant inhibition of inward late Na + (I NaL ) and/or L-type Ca 2+ (I CaL ) current can offer some protection against proarrhythmia. Therefore, we characterized the effects of buprenorphine and its major metabolite norbuprenorphine on cardiac hERG, Ca 2+ , and Na + ion channels, as well as cardiac APs. For comparison, methadone, a MOR agonist associated with QT C prolongation and high TdP risk, and naltrexone and naloxone, two opioid receptor antagonists, were also studied. Whole cell recordings were performed at 37°C on cells stably expressing hERG, Ca V 1.2, and Na V 1.5 proteins. Microelectrode array (MEA) recordings were made on human induced pluripotent stem cell-derived cardiomyocytes (iPSC-CMs). The results showed that buprenorphine, norbuprenorphine, naltrexone, and naloxone had no effect on I hERG , I CaL , I NaL , and peak Na + current (I NaP ) at clinically relevant concentrations. In contrast, methadone inhibited I hERG , I CaL , and I NaL . Experiments on iPSC-CMs showed a lack of effect for buprenorphine, norbuprenorphine, naltrexone, and naloxone, and delayed repolarization for methadone at clinically relevant concentrations. The mechanism of QT C prolongation is opioid moiety-specific. This remains undefined for buprenorphine, while for methadone it involves direct hERG channel block. There is no evidence that buprenorphine use is associated with TdP. Whether this lack of TdP risk can be generalized to other drugs with QT C prolongation not mediated by acute hERG channel block warrants further study.

59 BASIC BIOLOGICAL SCIENCES↗

Rigid stiffener-reinforced flexible neural probes, and methods of fabrication using wicking channel-distributed adhesives and tissue insertion and extraction

A stiffener-reinforced microelectrode array probe and fabrication method using wicking channel-distributed adhesives which temporarily adheres a flexible device onto a rigid stiffener for insertion and extraction. Assembly is by dispensing a liquid adhesive into a narrow open groove wicking channel formed on the stiffener so that the adhesive is wicked along and fills the channel by capillary action, and adhering the adhesive-filled bonding side of the elongated section of the rigid substrate to a flexible device.

Shah, Kedar G.↗

Instrument for spatially resolved, temperature-dependent electrochemical impedance spectroscopy of thin films under locally controlled atmosphere

We demonstrate an instrument for spatially resolved measurements (mapping) of electrochemical impedance under various temperatures and gas environments. Automated measurements are controlled by a custom LabVIEW program, which manages probe motion, sample motion, temperature ramps, and potentiostat functions. Sample and probe positioning is provided by stepper motors. Dry or hydrated atmospheres (air or nitrogen) are available. The configurable heater reaches temperatures up to 500 °C, although the temperature at the sample surface is moderated by the gas flow rate. The local gas environment is controlled by directing flow toward the sample via a glass enclosure that surrounds the gold wire probe. Software and hardware selection and design are discussed. Reproducibility and accuracy are quantified on a Ba(Zr,Y)O 3-δ proton-conducting electrolyte thin film synthesized by pulsed laser deposition. The mapping feature of the instrument is demonstrated on a compositionally graded array of electrocatalytically active Ba(Co,Fe,Zr,Y)O 3-δ thin film microelectrodes. The resulting data indicate that this method proficiently maps property trends in these materials, thus demonstrating the reliability and usefulness of this method for investigating electrochemically active thin films.

47 OTHER INSTRUMENTATION↗

Spatiotemporal analysis of 3D human iPSC-derived neural networks using a 3D multi-electrode array

While there is a growing appreciation of three-dimensional (3D) neural tissues (i.e., hydrogel-based, organoids, and spheroids), shown to improve cellular health and network activity to mirror brain-like activity in vivo , functional assessment using current electrophysiology techniques (e.g., planar multi-electrode arrays or patch clamp) has been technically challenging and limited to surface measurements at the bottom or top of the 3D tissue. As next-generation MEAs, specifically 3D MEAs, are being developed to increase the spatial precision across all three dimensions (X, Y, Z), development of improved computational analytical tools to discern region-specific changes within the Z dimension of the 3D tissue is needed. In the present study, we introduce a novel computational analytical pipeline to analyze 3D neural network activity recorded from a “bottom-up” 3D MEA integrated with a 3D hydrogel-based tissue containing human iPSC-derived neurons and primary astrocytes. Over a period of ~6.5 weeks, we describe the development and maturation of 3D neural activity (i.e., features of spiking and bursting activity) within cross sections of the 3D tissue, based on the vertical position of the electrode on the 3D MEA probe, in addition to network activity (identified using synchrony analysis) within and between cross sections. Then, using the sequential addition of postsynaptic receptor antagonists, bicuculline (BIC), 2-amino-5-phosphonovaleric acid (AP-5), and 6-cyano-5-nitroquinoxaline-2,3-dione (CNQX), we demonstrate that networks within and between cross sections of the 3D hydrogel-based tissue show a preference for GABA and/or glutamate synaptic transmission, suggesting differences in the network composition throughout the neural tissue. The ability to monitor the functional dynamics of the entire 3D reconstructed neural tissue is a critical bottleneck; here we demonstrate a computational pipeline that can be implemented in studies to better interpret network activity within an engineered 3D neural tissue and have a better understanding of the modeled organ tissue.

3D culture↗

Transitions between electron emission and gas breakdown mechanisms across length and pressure scales

This Perspective outlines theoretical, simulation, and experimental studies linking electron emission and gas breakdown. Many studies have investigated field emission-driven microscale gas breakdown, including recent reviews [Garner et al., IEEE Trans. Plasma Sci. 48, 808–824 (2020); Fu et al., Plasma Res. Express 2, 013001 (2020)]. This Perspective focuses on generalizing field emission-driven microscale gas breakdown to consider the contribution of other forms of electron emission, specifically thermionic and space-charge limited. Recent theoretical studies have unified thermionic, field, and space-charge limited emission with and without collisions to derive “nexuses” where the individual solutions match, indicating transitions in the mechanisms. Reducing device size to nanoscale at atmospheric pressure leads to a transition from field emission to space-charge limited emission for nitrogen at ~250 nm. This Perspective summarizes the derivation of these nexuses and future extensions. We next describe simulation and theoretical studies for field emission-driven microscale gas breakdown and highlight how the nexus theory may be integrated to account for temperature, space-charge, and pulse parameters. Finally, we summarize the development of optical techniques to assess microscale gas breakdown and recent nanoscale experiments at atmospheric pressure that suggest that space-charge may begin to contribute to field emission prior to gas breakdown. We highlight the combination of theory, simulation, and experiment to link electron emission and gas breakdown mechanisms across length, pressure, and temperature scales for applications that include vacuum electronics, pulsed power, and medicine.

71 CLASSICAL AND QUANTUM MECHANICS, GENERAL PHYSIC↗

Toward Spatial Control of Reaction Selectivity on Photocatalysts Using Area-Selective Atomic Layer Deposition on the Model Dual Site Electrocatalyst Platform

Photocatalytic water splitting is a promising route to low-cost, green H 2 . However, this approach is currently limited in its solar-to-hydrogen conversion efficiency. One major source of efficiency loss is attributed to the high rates of undesired side and back reactions, which are exacerbated by the proximity of neighboring oxidation and reduction sites. Nanoscopic oxide coatings have previously been used to selectively block undesired reactants from reaching active sites; however, a coating encapsulating the entire photocatalyst particle limits activity as it cannot facilitate both half-reactions. In this work, area selective atomic layer deposition (AS-ALD) was used to selectively deposit semipermeable TiO 2 films onto model metallic cocatalysts for enhancing reaction selectivity while maintaining a high overall activity. Pt and Au were used as exemplary reduction and oxidation cocatalyst sites, respectively, where Au was deactivated toward ALD growth through self-assembled thiol monolayers while TiO 2 was coated onto Pt sites. Electroanalytical measurements of monometallic thin film electrodes showed that the TiO 2 -encapsulated Pt effectively suppressed undesired H 2 oxidation and Fe(II)/Fe(III) redox reactions while still permitting the desired hydrogen evolution reaction (HER). A planar model photocatalyst platform containing patterned interdigitated arrays of Au and Pt microelectrodes was further assessed using scanning electrochemical microscopy (SECM), demonstrating the successful use of AS-ALD to enable local reaction selectivity in a dual-reaction-site (photo)electrocatalytic system. Finally, interdigitated microelectrodes having independent potential control were used to show that selectively deposited TiO 2 coatings can suppress the rate of back reactions on neighboring active sites by an order of magnitude compared with uncoated control samples.

08 HYDROGEN↗