Search NASA⌕ Search

SEARCH · Search NASA

Results for “microfluidic device”

Search indexed NASA NTRS and DOE OSTI research on propulsion, heat transfer, battery materials and energy systems. Follow report and document links to the original sources.

Quote a phrase for an exact phrase match. Source license links do not imply unrestricted reuse.

At least 19 records

Multivariate Analysis To Quantify Species in the Presence of Direct Interferents: Micro-Raman Analysis of HNO 3 in Microfluidic Devices

Microfluidic devices are a growing field with significant potential for application to small scale processing of solutions. Much like large scale processing, fast, reliable, and cost effective means of monitoring the streams during processing are needed. Here we apply a novel Micro-Raman probe to the on-line monitoring of streams within a microfluidic device. For either macro or micro scale process monitoring via spectroscopic response, there is the danger of interfering or confounded bands obfuscating results. By utilizing chemometric analysis, a form of multivariate analysis, species can be accurately quantified in solution despite the presence of overlapping or confounded spectroscopic bands. This is demonstrated on solutions of HNO 3 and NaNO 3 within micro-flow and microfluidic devices.

Lines, Amanda M.↗

Micro-Raman technology to interrogate two-phase extraction on a microfluidic device

Microfluidic devices provide ideal environments to study solvent extraction. When droplets form and generate plug flow down the microfluidic channel, the device acts as a microreactor in which the kinetics of chemical reactions and interfacial transfer can be examined. Among the many benefits of microreactors is the ability to maintain small sample volumes, which is especially important when studying solvent extraction in harsh environments, such as in separations related to the nuclear fuel cycle. In solvent extraction, the efficiency of the process depends on complex formation and rates of transfer in biphasic systems. Thus, it is important to understand the kinetic parameters in an extraction system to maintain a high efficiency and effectivity of the process. Here we present a methodology that combines chemometric analysis with on-line micro-Raman spectroscopy to monitor biphasic extractions within a microfluidic device. This monitoring provided concentration measurements in both organic and aquoeus plugs as they flowed through the microfluidic channel. The biphasic system studied was comprised of HNO3 as the aqueous phase and 30 % (v/v) tributyl phosphate in n-dodecane comprised the organic phase, which simulated the Plutonium Uranium Redox EXtraction (PUREX) process. Using pre-equilibrated solutions (post extraction) the validity of the technique and methodology is illustrated. Following this validation, solutions that were not equilibrated were examined and the kinetics of interfacial mass transfer within the biphasic system were established. Results were compared to kinetics already determined on a macro scale to prove the efficacy of the technique

extraction, interfacial transport, liquid:liquid e↗

A versatile and low-cost chip-to-world interface: enabling ICP-MS characterization of isotachophoretically separated lanthanides on a microfluidic device

Microfluidics offer novel and state-of-the-art pathways to process materials. Microfluidic systems drastically reduce timeframes and costs associated with traditional lab-scale efforts in the area of analytical sample preparations. The challenge arises in effectively connecting microfluidics to off-chip analysis tools to accurately characterize samples after treatment on-chip. Here, a fused silica microfluidic device (MFD) is connected to a fused-silica capillary in order to create a world-to-chip connection between the MFD and an inductively coupled plasma mass spectrometer (ICP-MS). Specifically, this is demonstrated by utilizing isotachophoresis (ITP) on a microfluidic chip to separate samples containing up to 14 lanthanides into elementally pure bands. The separated sample is successfully transferred across a 7 nL dead space at the microchip-capillary junction, such that separation resolution is maintained and even increased through the interface and into the ICP-MS, where the elemental composition of the separated sample is analysed. Lanthanide samples of varying composition are detected using ICP-MS, demonstrating this versatile and cost-effective approach that does not degrade the separation quality achieved on the MFD. This simple and inexpensive connection enables fast, low-cost sample preparation immediately prior to injection into an ICP-MS or other analytical instruments.

Lackey, Hope E.↗

Aerosol jet printing of surface acoustic wave microfluidic devices

Abstract The addition of surface acoustic wave (SAW) technologies to microfluidics has greatly advanced lab-on-a-chip applications due to their unique and powerful attributes, including high-precision manipulation, versatility, integrability, biocompatibility, contactless nature, and rapid actuation. However, the development of SAW microfluidic devices is limited by complex and time-consuming micro/nanofabrication techniques and access to cleanroom facilities for multistep photolithography and vacuum-based processing. To simplify the fabrication of SAW microfluidic devices with customizable dimensions and functions, we utilized the additive manufacturing technique of aerosol jet printing. We successfully fabricated customized SAW microfluidic devices of varying materials, including silver nanowires, graphene, and poly(3,4-ethylenedioxythiophene) polystyrene sulfonate (PEDOT:PSS). To characterize and compare the acoustic actuation performance of these aerosol jet printed SAW microfluidic devices with their cleanroom-fabricated counterparts, the wave displacements and resonant frequencies of the different fabricated devices were directly measured through scanning laser Doppler vibrometry. Finally, to exhibit the capability of the aerosol jet printed devices for lab-on-a-chip applications, we successfully conducted acoustic streaming and particle concentration experiments. Overall, we demonstrated a novel solution-based, direct-write, single-step, cleanroom-free additive manufacturing technique to rapidly develop SAW microfluidic devices that shows viability for applications in the fields of biology, chemistry, engineering, and medicine.

77 NANOSCIENCE AND NANOTECHNOLOGY↗

Automated control of microfluidic devices based on machine learning

A system is provided to automatically monitor and control the operation of a microfluidic device using machine learning technology. The system receives images of a channel of a microfluidic device collected by a camera during operation of the microfluidic device. Upon receiving an image, the system applies a classifier to the image to classify the operation of the microfluidic device as normal, in which no adjustment to the operation is needed, or as abnormal, in which an adjustment to the operation is needed. When an image is classified as normal, the system may make no adjustment to the microfluidic device. If, however, an image is classified as abnormal, the system may output an indication that the operation is abnormal, output an indication of a needed adjustment, or control the microfluidic device to make the needed adjustment.

42 ENGINEERING↗

Automated control of microfluidic devices based on machine learning

A system is provided to automatically monitor and control the operation of a microfluidic device using machine learning technology. The system receives images of a channel of a microfluidic device collected by a camera during operation of the microfluidic device. Upon receiving an image, the system applies a classifier to the image to classify the operation of the microfluidic device as normal, in which no adjustment to the operation is needed, or as abnormal, in which an adjustment to the operation is needed. When an image is classified as normal, the system may make no adjustment to the microfluidic device. If, however, an image is classified as abnormal, the system may output an indication that the operation is abnormal, output an indication of a needed adjustment, or control the microfluidic device to make the needed adjustment.

Giera, Brian↗

In Situ Chemical Monitoring and Imaging of Contents within Microfluidic Devices Having a Porous Membrane Wall Using Liquid Microjunction Surface Sampling Probe Mass Spectrometry

The ability to observe dynamic chemical processes (e.g., signaling, transport, etc.) in vivo or in situ using nondestructive chemical imaging opens a new door to understanding the complex dynamics of developing biological systems. With the advent of “biology-on-a-chip” devices has come the ability to monitor dynamic chemical processes in a controlled environment, using these engineered habitats to capture key features of natural systems while allowing visual observation of system development. Having the capability to spatially and temporally map the chemical signals within these devices may yield new insights into the forces that drive biosystem development. Here, a porous membrane sealed microfluidic device was designed to allow normal microfluidic operation while enabling continuous, location specific sampling and chemical characterization by liquid microjunction surface sampling probe mass spectrometry (LMJ-SSP MS). LMJ-SSP was used to extract fluids with nL-to-μL/min flow rates directly from selected areas of the microfluidic device without negatively impacting the device function. These extracts were subsequently characterized using MS. This technique was used to acquire MS images of the entirety of several multi-input microfluidic devices having different degrees of fluid mixing. LMJ-SSP MS imaging visualized the spatial distribution of chemical components within the microfluidic channels and could visualize chemical reactions occurring in the device. These microfluidic devices with a porous membrane wall are wholly compatible with the construction of biology-on-a-chip devices. This ultimately would enable correlation of biosystem physical structure with an evolving chemical environment

47 OTHER INSTRUMENTATION↗

Microfabrication of plastic-PDMS microfluidic devices using polyimide release layer and selective adhesive bonding

In this study, we present an improved method to bond poly(dimethylsiloxane) (PDMS) with polyimide (PI) to develop flexible substrate microfluidic devices. The PI film was separately fabricated on a silicon wafer by spin coating followed by thermal treatment to avoid surface unevenness of the flexible substrate. In this way, we could also integrate flexible substrate into standard micro-electromechanical systems (MEMS) fabrication. Meanwhile, the adhesive epoxy was selectively transferred to the PDMS microfluidic device by a stamp-and-stick method to avoid epoxy clogging the microfluidic channels. To spread out the epoxy evenly on the transferring substrate, we used superhydrophilic vanadium oxide film coated glass as the transferring substrate. After the bonding process, the flexible substrate could easily be peeled off from the rigid substrate. Contact angle measurement was used to characterize the hydrophicity of the vanadium oxide film. X-ray photoelectron spectroscopy analysis was conducted to study the surface of the epoxy. We further evaluated the bonding quality by peeling tests, which showed a maximum bonding strength of 100 kPa. By injecting with black ink, the plastic microfluidic device was confirmed to be well bonded with no leakage for a day under 1 atm. Finally, this proposed versatile method could bond the microfluidic device and plastic substrate together and be applied in the fabrication of some biosensors and lab-on-a-chip systems.

42 ENGINEERING↗

Non-contact temperature control system for microfluidic devices

The present invention relates to a temperature control system for a microfluidic device. The system allows for non-contact heating by employing an infrared emitter. In some instances, the system can be used in conjunction with a centrifugal microfluidic device. Optionally, a mask can be implemented to provide selective heating of desired assay areas of the device.

Phaneuf, Christopher↗

Protein and nucleic acid detection for microfluidic devices

The present invention relates to methods for detecting targets by employing a temperature control system with a microfluidic device. The system allows for non-contact heating by employing an infrared emitter. In some instances, the system can be used in conjunction with a centrifugal microfluidic device. Optionally, a mask can be implemented to provide selective heating of desired assay areas of the device.

Koh, Chung-Yan↗

Detection of active and latent infections with microfluidic devices and systems thereof

The present invention relates to methods of detecting one or more targets of interest in a sample. In one instance, the target can be correlated to an active infection (e.g., by a virus and/or a bacterium). Methods can include treating the sample with a dissociation agent, thereby releasing the target of interest for more accurate detection (e.g., by use of a sedimentation-based centrifugal microfluidic devices). Also described herein are microfluidic devices and systems for use with a dissociation agent.

59 BASIC BIOLOGICAL SCIENCES↗

Measuring the Electrochemical Corrosion of 233U-doped UO2 in a Microfluidic Device

We have developed a microfluidic, ‘particle-attached microfluidic electrochemical’ device, or PAMEC, that uses microgram quantities of radioactive materials, such as uranium dioxide (UO2), rather than bulk specimens to both observe electrochemical changes and measure spectroscopic properties. The PAMEC device reduces the need for running experiments in a shielded facility and allows for in-operando, real-time investigations of electrochemical properties and morphological changes of micrograms of particles. This novel design offers a promising platform to investigate spent nuclear fuel (SNF) and other nuclear materials under various controlled condition, and to provide insights to nuclear waste management, and fuel performance

Electrochemistry↗

Fluid control structures in microfluidic devices

Methods and apparatus for implementing microfluidic analysis devices are provided. A monolithic elastomer membrane associated with an integrated pneumatic manifold allows the placement and actuation of a variety of fluid control structures, such as structures for pumping, isolating, mixing, routing, merging, splitting, preparing, and storing volumes of fluid. The fluid control structures can be used to implement a variety of sample introduction, preparation, processing, and storage techniques.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Fluid control structures in microfluidic devices

Methods and apparatus for implementing microfluidic analysis devices are provided. A monolithic elastomer membrane associated with an integrated pneumatic manifold allows the placement and actuation of a variety of fluid control structures, such as structures for pumping, isolating, mixing, routing, merging, splitting, preparing, and storing volumes of fluid. The fluid control structures can be used to implement a variety of sample introduction, preparation, processing, and storage techniques.

Mathies, Richard A.↗

A monolayer microfluidic device supporting mouse spermatogenesis with improved visibility

In our previous study, we produced a microfluidic device (MFD) which successfully maintained spermatogenesis for over 6 months in mouse testis tissues loaded in the device. In the present study, we developed a new MFD, a monolayer device (ML-D) with a barrier structure consisting of pillars and slits, which is simpler in design and easier to make. This ML-D was also effective for inducing mouse spermatogenesis and maintained it for a longer period than the conventional culture method. In addition, we devised a way of introducing sample tissue into the device during its production, just before bonding the upper layer of polydimethylsiloxane (PDMS) and bottom glass slide. The tissue can obtain nutrients horizontally from the medium running beside it and oxygen vertically from above through PDMS. In addition, the glass slide set at the bottom improved the visibility of the sample tissue with an inverted microscope. When we took photos of cultured tissue of the Acr-Gfp transgenic mouse testis in ML-D sequentially every day, morphological changes of the acrosome during spermiogenesis were successfully recorded. The ML-D is simple in design and useful for culturing testis tissue for inducing and maintaining spermatogenesis with clearer visibility. Due to the new method of sample loading, tissues other than testis should also be applicable.

60 APPLIED LIFE SCIENCES↗

A capillary-based microfluidic device enables primary high-throughput room-temperature crystallographic screening

A novel capillary-based microfluidic strategy to accelerate the process of small-molecule-compound screening by room-temperature X-ray crystallography using protein crystals is reported. The ultra-thin microfluidic devices are composed of a UV-curable polymer, patterned by cleanroom photolithography, and have nine capillary channels per chip. The chip was designed for ease of sample manipulation, sample stability and minimal X-ray background. 3D-printed frames and cassettes conforming to SBS standards are used to house the capillary chips, providing additional mechanical stability and compatibility with automated liquid- and sample-handling robotics. These devices enable an innovative in situ crystal-soaking screening workflow, akin to high-throughput compound screening, such that quantitative electron density maps sufficient to determine weak binding events are efficiently obtained. This work paves the way for adopting a room-temperature microfluidics-based sample delivery method at synchrotron sources to facilitate high-throughput protein-crystallography-based screening of compounds at high concentration with the aim of discovering novel binding events in an automated manner.

37 INORGANIC, ORGANIC, PHYSICAL, AND ANALYTICAL CH↗

Automated methods for scalable, parallelized enzymatic biopolymer synthesis and modification using microfluidic devices

Methods for the automated template-free synthesis of user-defined sequence controlled biopolymers using microfluidic devices are described. The methods facilitate simultaneous synthesis of up to thousands of uniquely addressed biopolymers from the controlled movement and combination of regents as fluid droplets using microfluidic and EWOD-based systems. In some forms, biopolymers including nucleic acids, peptides, carbohydrates, and lipids are synthesized from step-wise assembly of building blocks based on a user-defined sequence of droplet movements. In some forms, the methods synthesize uniquely addressed nucleic acids of up to 1,000 nucleotides in length. Methods for adding, removing and changing barcodes on biopolymers are also provided. Biopolymers synthesized according to the methods, and libraries and databases thereof are also described. Modified biopolymers, including chemically modified nucleotides and biopolymers conjugated to other molecules are described.

Banal, James↗