Microgravity Game Changers: Recent Accomplishments of Microgravity Assisted Materials Experiments on the ISS

This paper discusses important new materials, devices and technology produced in low-Earth orbit (LEO) that have been developed with funding from NASA’s In Space Production Applications (InSPA) Portfolio. In coordination with the International Space Station (ISS) National Laboratory, InSPA supports innovative small businesses and other research & development organizations to develop microgravity-assisted applications that make significant impacts in a wide variety of industries on Earth. These technology development efforts are using the microgravity of orbital space to overcome gravity-induced defects on Earth to create high-value products for terrestrial markets in the areas of semiconductors, pharmaceuticals, and communications. Through 24/7/365 operation on ISS for 25 years, coupled with commercial space transportation and services to, in, and from orbit, the microgravity environment has enabled pioneering science and significant commercial applications, including novel medical advances. World-leading researchers, innovators, and space payload developers provide compelling evidence through demonstrations on the ISS that materials processing in microgravity improves outcomes for a wide range of materials and products at all levels of the organization of matter, from quantum entities such as Bose-Einstein condensates, to crystals, alloys, composites, thin films, and photonics, to stem cells, medical diagnoses, medical treatments, and medical devices for humans. As of 2026, numerous examples proved by demonstration on ISS show the potential of these technologies in various fields. In this paper, a summary of four important experiments is presented.

microgravity medical devices

Final Report Document: Microgravity Medical Eyewash B

Senior Capstone Design Team 15 has been commissioned by the National Aeronautics and Space Administration (NASA) to redesign the current microgravity eye wash station. The current design exhibits four primary limitations: single-use operation, excessive mass and volume, operational complexity requiring coordination with external systems, and dependence on frequent Earth resupply missions. Our updated eyewash design will be deployed on long-range space missions that could last multiple years. Based on these and other requirements from our customer, we have developed our updated eyewash design. Our compact, single-eye system uses capillary-driven flow and a free-floating water ball. This design allows us to eliminate pumps and bulky tubing, decreasing the mass and volume of the overall system. The containment eyecup is held to the astronaut's face with a strap, and a silicone seal prevents leakage while improving user comfort. Contaminated water is contained within a disposal bag containing wicking material to pull it back out of the eyecup after washing the eye. This system is reusable, efficient, and easy to activate quickly. We evaluated our design through calculations, microfluidic testing, and user try-on testing to verify our requirements. Our work demonstrated that steady-state flow was capable with our capillary framework, achieving 1.31 L/min. The prototype construction confirmed mass and volume reductions, and try-on-testing evaluated the ability to put on the system quickly. Almost all major design requirements were achieved, and water loss could be validated by testing in microgravity. Our design went through a number of iterations to reach the final solution presented in this report. These changes were driven by our testing and collaboration from each member of the team. Updated models optimized tube placement and geometry of the eyecup to better direct flow as it pools across the eye. Changes to our tubing bends improved capillary efficiency and increased the flow rate we were capable of achieving. And improved bracket placements adjusted the fit, comfort, and seal of the eyecup to the astronaut's face. Our capillary-based eyewash system is technically feasible and has been theoretically validated to operate effectively in microgravity conditions. Testing and analysis indicate that it can meet or exceed the required performance metrics, including flow rate and safety constraints. Overall, the design represents a viable alternative to current ISS-dependent eyewash systems for future space missions.

Jeffrey Allen

Extended Duration Orbiter Medical Project Microbial Air Sampler (STS-50/USML-1)

The Microbial Air Sampler was used on mission days 1, 7, and 13 in the Spacelab during STS-50/USML-1. Microbial air samples were collected using two types of media strips containing agar (Rose Bengal for yeast and molds, TSA for bacteria). The bacterial level found on day 1 was lower than experienced on previous Spacelab missions. A high level of fungi was present on day 1, however subsequent samples on days 7 and 13 did not indicate fungal growth. Bacterial growth was also minimized in this microgravity environment as the mission progressed. No pathogenic microorganisms were isolated, and the health risk from airborne microbes was minimal throughout the mission.

Duane L Pierson

Direct comparison of gamma, electron beam and X-ray radiation effects on the polymers of a pulsed lavage device

Gamma radiation used for sterilization of medical devices is challenged by cobalt-60 supply and commercial capacity. To maintain a robust radiation sterilization marketplace for the rapidly growing single-use medical device industry, investigation of potential alternatives to gamma technology, such as electron beam (e-beam) and X-ray technology, is critical. In this work, we directly compare the effects of radiation source and absorbed dose level on the polymeric materials and function of a commercial pulsed lavage device used for wound care. Product functionality, polymer mechanical, and polymer optical properties were evaluated using standard methods and input from the device manufacturer. Test results show that functionality of the product was not inhibited by radiation although the battery in the device exposed to X-ray exhibited greater voltage loss compared to batteries in products exposed to gamma or e-beam. Statistically significant differences between gamma and e-beam exposure and between gamma and X-ray exposure were also observed for product appearance in terms of yellowness index of several of the polymers considered. Overall, the results of this study support the viability of e-beam and X-ray radiation technologies as alternatives to cobalt-60 gamma technology for sterilization of the single-use pulsed lavage medical device investigated.

Electron beam

Analytical Model for Steady Flow through a Finite Channel with One Porous Wall with Arbitrary Variable Suction or Injection

This paper presents an exact solution of two-dimensional laminar flow through a finite length channel with one porous wall. It improves upon previous solutions by (1) satisfying the no-slip boundary condition at the channel dead end, (2) adding a turbulent term to the porous wall boundary condition, (3) allowing for arbitrary variable suction or injection across the porous wall, and (4) model validation against new cryogenic liquid hydrogen and oxygen experimental data. Of particular interest in the current work is the modeling of cryogenic propellant flow through a porous liquid acquisition device (LAD) screen and channel inside a propellant tank. First, a detailed review of the literature is presented for previously attempted solutions to channel flow with one porous wall. Next, the governing equations, boundary conditions, and model assumptions are used to derive the analytical flow solution and present general model results for pressure and velocity fields within the channel. Then, the model solution is compared with horizontal LAD channel flow data in liquid oxygen as well as vertical LAD channel flow data in an inverted outflow configuration in liquid hydrogen. Model results are used to update the static cryogenic bubble point pressure model with a dynamic bubble point term which factors in enhanced convection and cooling at the screen during propellant outflow. Convective heat transfer at the LAD screen during outflow is also quantified by comparing model and data. The new analytical flow solution with the dynamic bubble point model is shown to compare well with available cryogenic experimental data

Navier Stokes Equations

Medical Aspects of Gemini Extravehicular Activities

The medical aspects of Gemini extravehicular activities are principally concerned with the physiological responses to high workloads, high thermal stresses, and low fatigue tolerance. Analysis of physiological instrumentation data. from extravehicular flights and training operations contributed significantly to the understanding of extra-vehicular workloads and the means of controlling these workloads.

G Fred Kelly

A Review of Medical Results of Gemini 7 and Related Flights

On August 23, 1966, a review of the medical findings of the fourteen day Gemini 7 mission and related flights was conducted. This review was organized at the request of Dr. George E. Mueller, Associate Administrator for Manned Space Flight, and consisted of presentations by the Principal Investigators of the Gemini Medical Flight Experiments and by the Director, Medical Research and Operations, Manned Spacecraft Center. This document is a compilation of the material presented at the review. The Principals cooperated most significantly by reviewing a transcription of a tape recording of their presentation, editing and providing a final version for publication. Without this most generous assistance, this document could not have been published. Table I, which follows immediately after this Introduction, is presented to acquaint the reader with the scope and sequence of medical measurements and experiments which were conducted during Project Gemini. This review was held prior to the conduct of the Gemini 11 and 12 missions, therefore, material derived from those flights is not included in this document.

E J McLaughlin

Effect of Microgravity on Several Visual Functions During STS Shuttle Missions

Many astronauts and cosmonauts have commented on apparent changes in their vision while on-orbit. Comments have included statements of supposed improved distance acuity to decreased near vision capability. The purpose of this study was to assess not only changes in visual acuity, but expand the assessment to several other visual functions for a comprehensive battery of tests. Vision was assessed using an innovative device, the Visual Function Tester - Model 1 (VFT-1), which presents the tests at optical infinity and includes critical flicker fusion, stereopsis to 10 seconds-of-arc, visual acuity in small steps to 20/7.7, cyclophoria, lateral and vertical phoria, and retinal rivalry. Vision was assessed 2 times prelaunch at L-14 days and L-7 days, 3-4 times while on-orbit, at landing, and 2 times postlanding at L+3 days and L+7 days. There were 26 STS astronauts that participated, with data on 20 astronauts used for analysis. There was a typical wide variability between subjects in baseline visual performance for each parameter at the prelaunch sessions. There was a slight but statistically significant decrease in visual acuity while on-orbit that was not clinically significant. For stereopsis (i.e. depth perception), there was a small improvement on-orbit that was not statistically significant. There were no changes during space flight for any of the other visual parameters tested. A few individuals showed apparent changes in acuity and stereopsis. The possibility exists that microgravity affects the visual system of some individuals differently, as with space adaptation syndrome. Repeat data on 2 astronauts showed good repeatability between the 2 flights. These results pertain to only short term space flight on the STS shuttle, and longer flights are necessary to determine if there is any relationship between mission duration and these visual functions.

Melvin R O'Neal

Influential Factors for Liquid Acquisition Device Screen Selection for Cryogenic Propulsion Systems

This paper presents the influential factors which govern screen selection for liquid acquisition devices (LADs) operating in microgravity conditions for future in-space cryogenic propulsion engines and cryogenic propellant depots. Space flight requirements, which include mass flow rate, acceleration level and direction, and thermal environment, dictate screen selection for a particular mission. The five influential factors include bubble point pressure, flow-through-screen pressure drop, wicking rate, screen compliance, and material compatibility. Governing equations and analytical models for these parameters are developed from first principles. A comprehensive survey of the historical data on coarser LAD meshes over four decades of work is conducted, and liquid hydrogen data for finer Dutch Twill meshes (325 x 2300, 450 x 2750, 510 x 3600) from recently concluded experiments is also presented to validate analytical models. Each of these parameters is measurable from ground based tests, making it facile to predict flight system performance. Therefore analytical models in this paper will be valuable for future LAD designs for both cryogenic and storable propulsion systems. Additionally, analysis will be given on the impact of the factors on liquid hydrogen systems.

Fuel Depot

A Transient Hydrodynamic Model of Screen Channel Liquid Acquisition Devices for In-Space Cryogenic Propellant Management

Screen channel liquid acquisition devices (LADs) will play a crucial role in future deep space travel. It is essential that vapor-free delivery of propellants during tank-to-tank transfer is ensured to maximize yield from storage tanks and prevent potential combustion instabilities. The screen channel LAD utilizes a fine screen wire mesh that can separate phases in a low Bond number (i.e. microgravity) environment using surface tension forces. This study presents the development and verification of a new model for transient screen compliance, one of the influential factors for screen channel LAD design. Screen compliance is crucial during LAD channel outflow transients because the slight deflection of the screen can provide needed mass to satisfy rapid outflow demands and reduce the pressure difference across the screen. The model is successfully verified against CFD simulations. In addition, the characteristic speed for the governing screen compliance equations is derived which allows for numerical stability criteria to be established. As shown in this study, the transient maximum pressure difference across the screen can greatly exceed the steady state maximum pressure difference across the screen in many cases.

Hydrodynamics Simulations

Fifth Annual Workshop on Space Operations Applications and Research (Soar 1991), Volume 1

More than 110 papers were presented at this Symposium, sponsored by the U.S. Air Force Phillips Laboratory, the University of Houston-Clear Lake, and NASA JSC. The technical areas covered were Intelligent Systems, Automation and Robotics, Human Factors and Life Sciences, and Environmental Interactions. The U.S. Air Force and NASA programmatic overviews and panel discussions were also held in each technical area. These proceedings, along with the comments and suggestions made by the panelists and keynote speakers, will be used in assessing the progress made in joint USAF/NASA projects and activities. Furthermore, future collaborative/joint programs will also be identified. The symposium proceedings includes papers covering various disciplines presented by experts from NASA, the Air Force, universities, and industry.

Mars missions

Fourth International Microgravity Combustion Workshop

This proceedings document is a compilation about work performed by a community of researchers from universities, industry and government laboratories across the United States and in Europe and Japan who have recognized the value of the reduced-gravity environment in attacking the fundamental and practical problems of combustion science. On their behalf, I am pleased to present this document to the assembled participants at the Fourth International Microgravity Combustion Workshop, to be held near the NASA Lewis Research Center in Cleveland, Ohio, on May 19-21, 1997.

Microgravity

Measurement of Interfacial Tension of Immiscible Liquid Pairs in Microgravity

A discussion is given of a containerless microgravity experiment aimed at measuring the interfacial tension of immiscible liquid pairs using a compound drop rotation method. The reasons for the failure to execute such experiments in microgravity are described. Also, the results of post-flight analyses used to confirm our arguments are presented.

Michael C Weinberg

Connectivity, Pathology, and ApoE4 Interactions Predict Longitudinal Tau Spatial Progression and Memory

ABSTRACT Tau pathology spread into neocortex indicates a transition from healthy aging to Alzheimer's disease (AD). Connectivity between tau epicenters and later accumulating regions of cortex has been proposed as a mechanism of tau spread, but how this relationship changes with greater AD pathology burden or genotype is not understood. We investigated tau accumulation in two key regions, precuneus and inferior temporal cortex, using resting state functional connectivity (rsFC) and longitudinal PET imaging from a multicohort sample of cognitively unimpaired older adults. We examined how baseline tau PET, Aβ PET, and ApoE4 genotype status interact with rsFC between hippocampus and these downstream regions to predict rate of tau accumulation in neocortex. We found that the 3‐way interaction between connectivity, baseline tau, and baseline Aβ or ApoE4 status was associated with neocortical tau accumulation in precuneus and inferior temporal cortex. In addition, baseline tau, Aβ, and ApoE4 status also moderated the association between connectivity and rate of memory decline. Together, these results suggest that the extent and distribution of future tau accumulation may be predicted by the interaction of baseline connectivity, AD pathology, and genetic risk.

Neurosciences & Neurology

Vapor Transport Crystal Growth of Mercury-Cadmium-Telluride in Microgravity

Two epitaxial growth experiments of Hg 1-x Cd x Te layers on (100) CdTe substrates in closed ampoules using HgI 2 as a transport agent have been performed during the USML-1 mission. The characterization results to date demonstrate a considerable improvement of the space-grown epitaxial layers relative to ground-control specimens in terms of morphology, compositional uniformity, and structural micro homogeneity. These results show the effects of microgravity and fluid dynamic disturbances on-ground on the deposition and growth processes. The continued analysis of this technologically important system is designed to further elucidate the observed crystallographic improvements and their relation to mass flow.

Heribert Wiedemeier