Cyber-Resilient Design Methodology for Microgrids

Recent advancement in tools has helped with microgrid design, development, planning and operation. Microgrids offer a unique application based on users with different requirements for tools. The process of designing, constructing, commissioning, and assessing a microgrid is not always straightforward due to these distinct requirements. Additionally, metrics are needed for performance evaluation. This panel will offer an overview and description of tools that helps with microgrid design, construction, planning, operation, cyber security, and metrics-driven performance assessment driven by multiple diverse applications and use cases.

CCE↗

Data Analytics and Visualization of Energy Systems for Critical Infrastructure Insights

Modernization of energy systems including transportation facilities provides opportunities for increased efficiency, expansion of commerce and meeting industry and federal goals. A significant increase in electrical demand is projected to meet these needs, which concentrates at facilities such as airports. For example, Xcel Energy working with two airports in their service area recently published information projecting an up to fivefold increase in electricity demand in the next 25 years [1]. Concurrently, the US Government Accountability Office (GAO) recently surveyed 30 commercial service airports identifying more than 300 outages of more than 5 minutes between 2015 and 2022 [2]. Power, reliability, and resilience planning becomes more important to safely maintain operations and the flow of commerce with fewer energy carriers providing necessary energy to safely move passengers and goods. NREL proposes to develop methodologies to allow owners, utilities, and federal agencies to dynamically analyze, forecast, and manage energy loads at airports, focused upon maintaining the flow of commerce in an efficient, sustainable, and resilient way. To address these energy challenges, a suite of technologies and methodologies can be leveraged to validate concepts, inform design, de-risk solutions and optimize energy management during deployment. These technologies include digitalization of energy systems, microgrid methodologies, and related energy technologies for building and vehicle loads. [1] Electrifying Airport Ecosystems - https://www.enterprisemobility.com/content/dam/enterpriseholdings/marketing/innovation-in-mobility/vehicle-innovation/airport-electrification-study-full-report-2024.pdf [2] Airport Infrastructure: Selected Airport's Efforts to Enhance Electrical Resilience https://www.gao.gov/products/gao-23-105203.

critcal infrastructure↗

Software Control Program For Transportable Microgrid State-of-charge Balancing And Frequency Stability Controls

A deterministic state-of-charge (SOC) balancing approach software control code is introduced as an integral secondary management to primary control layer of an islanded small microgrid or nanogrid system made up of multiple grid-forming inverter/battery/solar combination systems, where each set of batteries with each inverter are on independent DC buses (i.e. non-paralleled on the DC sides). A DERMS-level control approach, algorithm and automation controller program was developed to improve coordination and enable microgrid asset compliance and SOC balancing, enabling provision of a system-level power stability support architecture, load support, and asset scalability. The architecture is configured to treat each unit or micro/nano-grid as a node in a microgrid network, allowing for autonomous DERMS control regarding load and SOC balancing and power stability. As the network grows with the addition of units, greater coordination efforts may be required. The ideal small network microgrid ranges from 2-10 inverter/battery units before additional control parameters must be considered in the existing architecture. The control approach focuses on a deterministic state-of-charge analysis as the primary level control process followed by a secondary control loop using a forced frequency-watt droop strategy to conform off-the-shelf components into behaving under a leader-follower configuration. Adopting this control scheme has been shown to allow for a balanced, unit-coordinated microgrid network, enabling stable power flow. The deterministic state-of-charge approach is introduced as an integral primary control layer of an islanded small network microgrid. A standard strategy for SOC balancing is implementing a battery management system (BMS) to control SOC on the DC side. An alternative approach is to determine how to coordinate sending and receiving power on the AC side with multiple units. The latter approach assesses all the integrated units in the microgrid network. Once the individual units are identified, further system data is required to calculate each unit's total kWh, provided information about its capability to supply or consume kWh and availability. The secondary control layer in the multi-layered small network microgrid methodology uses the primary layer’s decision to initiate frequency setpoint changes, initializing the SOC balancing. The secondary control layer considers numerous system-dependent variables to enable a charging and discharging profile based on adjustable frequency setpoints. The combined architecture will result in stable, coordinated power flow enhancing an AC microgrid's functionalities.

Myers, KurtS [Idaho National Laboratory (INL), Ida↗

Methodology to Implement a Microgrid in a University Campus

This paper presents the method we followed to design a microgrid at a university campus based on available resources. Due to introduction of renewable resources to produce energy, a methodology that allows design a microgrid in a university campus is very useful. Hence, we present a series of steps that must be carried out to estimate the resource to be used, the installation, area needed, and the capacity of the systems needed are also described. In addition, the models of the distributed resources that constitutes the microgrid are presented and explained. To validate the proposed methodology, simulations were performed using Opal-RT-LAb. As a test scenario we selected the Mayagüez campus of the University of Puerto Rico where we conducted analysis of the available resource and capacity of the systems is needed to satisfy demand of critical loads, considering a predetermined number of days of austerity. Our study results in determination of dimensions, cost and effectiveness of the microgrid. Simulations results also show that the proposed microgrid satisfy demand with the same reliability, or better, than the traditional electrical network. Additionally, the best options for this purpose are photovoltaic, batteries, and combined heat and power, if the technological advances and availability of resources to the date for Puerto Rico are considered.

36 MATERIALS SCIENCE↗

Antigua and Barbuda Distributed Energy Resources Deployment Guidelines

This document is designed to provide comprehensive considerations, best practices and guidance for deployment of Distributed Energy Resources (DERs) in Antigua and Barbuda. The document provides lists of various technology selection guidance including technical specifications, requirements and applicable key standards and code associated with key DERs and balance of plant equipment. The document also presents the key microgrid design considerations to integrate the DERs to achieve the economic, decarbonization and resiliency goals. Taking into account sensitive grid for such islands, for grid readiness and screening the potential DER interconnection, general approach is highlighted along with the potential technical interconnection requirements. Furthermore, this document shows the key stakeholders involved in such DER integration and/or microgrid project and how key responsible project team can be qualified. Finally, this document refers to key information about warranties and consumer rights and maintenance of the systems.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Dynamic Modeling of Sequential Service Restoration in Islanded Single Master Microgrids

This paper presents a methodology for generating restoration sequences in distribution systems and microgrids with emphasis on deriving optimal switching times for remote control switches (RCS). Microgrid architecture considered are assumed to be operating in islanded single master mode. Control methods for handling the unbalance inherent in distribution systems using single-phase controlled PQ inverters were developed and incorporated in the proposed method. The problem of considering simultaneously both energy optimization and dynamic stability of the system, which is lacking in existing methods, was addressed by studying the transient behavior of microgrids based on extended EMTP simulations and then approximate and incorporate these behaviors into the optimization formulation for restoration. The approach is based on multi-objective optimization of final restored load and total restoration time. The methodology was studied on a modified IEEE 123 node test feeder. An EMTP simulation in PSCAD of the formed microgrids was used to validate the accuracy of the dynamic and steady-state characteristics of the resulting systems. By considering the transient behavior of DGs during restoration, a better restoration sequence that does not trigger protection relays could be realized.

42 ENGINEERING↗

Enhancing Cyber Resilience of Networked Microgrids using Vertical Federated Reinforcement Learning

This paper presents a novel federated reinforcement learning (Fed-RL) methodology to inject sufficient resiliency into the operations of the network of microgrids. We consider adversarial actions to the voltage and power control loop reference signals at the grid forming (GFM) inverters in the microgrids which are essential to integrate renewable resources. Therefore, we formulate a resilient reinforcement learning training setup that uses these adversarial injections to generate episodic trajectories and train the RL agents to alleviate their impact on performance. To circumvent the concerns about data-sharing and privacy for different owners of the microgrids in the networked setting, we bring in the aspects of the federated operation to propose novel Fed-RL algorithms. As the dynamics of each microgrid are coupled due to electrical interlinks, the conventional federated RL approaches using decoupled independent environments are not applicable, which leads us to propose a multi-agent vertically federated variation of actor-critic algorithms, namely federated soft actor-critic (FedSAC). We have performed numerical simulations on an IEEE 123-bus benchmark test feeder with three microgrids by creating a customized simulation setup by encapsulating the microgrid dynamic simulations in GridLAB-D/HELICS co-simulation platform with the OpenAI Gym environment and validated the proposed resilient and secured learning methodology.

Artificial Intelligence (AI), reinforcement learni↗

Model-based Cyber-attack Detection for Voltage Source Converters in Island Microgrids

With the upgrading of communication and control in microgrids, cyber threats on the power converters are increasing. Here, in this paper, a novel model-based cyber-attack detection methodology is proposed for each voltage source converter in microgrids. The Harmonics State Space Matrix (H-Matrix) is used to build the closed-loop transfer function, providing model-based estimation with the grid voltage and control reference. Then, the space phase model (SPM) is used to calculate residual to detect cyber-attacks in voltage source converter (VSC). As controller and converter parameters are included in the H-matrix, the proposed method also could detect cyber-attacks when voltage fluctuation occurs in the grid. To verify the feasibility of the proposed method, several attacks targeting VSC in an islanded microgrid are simulated in MATLAB. Simulation and detection results are introduced to demonstrate the resilience and feasibility of the proposed method.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Design of Resilient Electric Distribution Systems for Remote Communities: Surgical Load Management using Smart Meters

This paper describes a systematic process of designing resilient electric distribution systems and microgrids using smart meters for surgical load management (SLM) as part of Advanced Metering Infrastructure (AMI). The work focuses on selection approach, integration, and interoperability aspects for AMI in microgrids. SLM is proposed as a granular control methodology for serving selective critical loads across different distribution feeders in the system during extreme events. The surgical load shedding as well as load pick-up provides a robust approach for maximizing critical load served in a resource-constrained electric distribution system or a microgrid. We present the case of a 20 MW islanded microgrid in Cordova, AK, USA, which is the demonstration site for field validation of resilience enhancement technologies for the DOE-funded Grid Modernization project RADIANCE. Cordova microgrid is an islanded distribution grid that provides an environment to prove the approach, and the techniques may also be applicable to other regional distribution systems.

microgrids↗

Design of Resilient Electric Distribution Systems for Remote Communities: Surgical Load Management Using Smart Meters: Preprint

This paper describes a systematic process of designing resilient electric distribution systems and microgrids using smart meters for surgical load management (SLM) as part of Advanced Metering Infrastructure (AMI). The work focuses on selection approach, integration, and interoperability aspects for AMI in microgrids. SLM is proposed as a granular control methodology for serving selective critical loads across different distribution feeders in the system during extreme events. The surgical load shedding as well as load pick-up provides a robust approach for maximizing critical load served in a resource-constrained electric distribution system or a microgrid. We present the case of a 20 MW islanded microgrid in Cordova, AK, USA, which is the demonstration site for field validation of resilience enhancement technologies for the DOE-funded Grid Modernization project RADIANCE. Cordova microgrid is an islanded distribution grid that provides an environment to prove the approach, and the techniques may also be applicable to other regional distribution systems.

microgrids↗

An ODE-Enabled Distributed Transient Stability Analysis for Networked Microgrids

Networked microgrid (NMG) exhibits noteworthy resiliency and flexibility benefits for the mutual support from neighboring microgrids. With high penetration of distributed energy resources (DERs) and the associated controls, the transient stability analysis of NMGs is of critical significance. To address the issues of computation burdens and privacy in the centralized transient analysis, this paper devises an ordinary differential equation (ODE)-enabled distributed transient stability (DTS) methodology for NMGs. First, an ODE-based microgrid model is established to capture the dynamics in the droop control of DERs as well as network and load. Further, a distributed DTS is devised for the ODE representation of an NMG, allowing a privacy-preserving transient analysis of each microgrid while accurately reconstructing the frequency dynamics under droop controls in all DERs. In conclusion, extensive tests are performed to verify the validity of the ODE-based microgrid model through both dynamic response and eigenvalue analysis, and the efficacy of the DTS algorithm in simulating the large signal responses and the frequent fluctuations in NMG.

29 ENERGY PLANNING, POLICY, AND ECONOMY↗

Graph theory and nighttime imagery based microgrid design

Reducing the duration and frequency of blackouts in remote communities poses an engineering challenge for grid operators. Outage effects can also be mitigated locally through microgrids. This paper develops a systematic procedure to account for these challenges by creating microgrids prioritizing high value assets within vulnerable communities. Nighttime satellite imagery is used to identify vulnerable communities. Using an asset classification and rating system, multi-asset clusters within these communities are prioritized. Infrastructure data, geographic information systems, satellite imagery, and spectral clustering are used to form and rank microgrid candidates. A microgrid sizing algorithm is included to guide through the microgrid design process. Finally, an application of the methodology is presented using real event, location, and asset data.

24 POWER TRANSMISSION AND DISTRIBUTION↗

Impact of Emergency Diesel Generator Reliability on Microgrids and Building-Tied Systems

Microgrids are an emerging alternative as an energy backup system for critical electric loads and have improved performance compared to the traditional architecture where a single emergency diesel generator is tied to an individual building. Both architectures are dependent on the reliability of their individual generators and a quantitative and realistic comparison of the overall system reliability of the two architectures is lacking. Using recently published work on emergency diesel generator finite reliability, a quantitative methodology is presented to compare the reliability of a microgrid architecture based on centralized emergency diesel generators to the traditional approach of generators tied to individual buildings. Three system reliability performance metrics are calculated as a function of outage duration: (1) probability to meet 100% of the critical load; (2) expected fraction of lost load; and (3) probability to meet the highest priority critical loads. It is shown that stand-alone building-tied emergency diesel generators systems, even when two emergency diesel generators are used per building, cannot provide the reliability required to sustain critical loads for a grid outage lasting multiple days. Due to their network configuration and ability to share load, diesel generator-based microgrid configurations are estimated to have = 93% probability of powering all buildings for a 2-week outage there the individual building-tied emergency diesel generator architecture has a =20% probability. Microgrids do present other susceptibilities that are site specific and should be considered including vulnerabilities associated with the on-campus distribution system and cybersecurity.

backup power↗

Reducing microgrid availability to reduce costs for coastal Puerto Rican communities

Renewable microgrids are sustainable, resilient solutions to mitigate and adapt to climate change. Making electric loads nearly 100% available (i.e., power remains on) during outages increases cost. Near 100% availability is required when human life or high-cost assets are involved, but availability can be reduced for less consequential loads leading to lower costs. This study analyses costs for photo-voltaic and lithium-ion battery microgrids with availability ranging from 0–99%. We develop a methodology to analyse three Puerto Rican coastal communities. Here, we consider power outage effects for hurricanes, earthquakes, and everyday outages. The results show cost versus availability from 0–99%. There is 27–31% cost reduction at 80% availability in comparison to 99% availability. A regression model of microgrid availability versus three ratios: 1) the annual generation to demand ratio, 2) storage to interruption energy ratio, and 3) peak storage to load ratio produced a coefficient of determination of 0.99949 with 70% of the data used for training and 30% for testing. The results can therefore be extended to other coastal Puerto Rican communities of varying sizes that have ratios within the ranges analysed in this study. This can empower decision makers to rapidly analyse designs that have availabilities well below 100%.

32 ENERGY CONSERVATION, CONSUMPTION, AND UTILIZATI↗

Design of Controller Hardware-In-the-Loop Model of Microgrid with Modular Building Blocks and Automated Design Script

The scalability of controller hardware-in-the-loop (CHIL) simulation is critical for validating control coordination and energy management in microgrids with distributed energy resources, especially as these modern systems become more complex and decentralized. This paper presents a CHIL modeling methodology that combines modular building blocks with an automated design script to streamline the development of high-fidelity microgrid models. Standardized subsystem templates for resources, converters, and buses are integrated with a Python-based script that compiles structured JSON configuration files into simulation-ready initialization code. The proposed approach reduces development time, improves model consistency, and enhances simulation fidelity. The methodology is validated on a Typhoon HIL604 platform and is broadly applicable to real-time simulation of complex, networked microgrid systems. This framework establishes a foundation for automated, scalable CHIL validation and accelerates the design of next-generation distributed energy systems.

Kim, Namwon [ORNL] (ORCID:0000000200438489)↗

Robust trajectory-constrained frequency control for microgrids considering model linearization error

Grid supportive modes integrated within inverter-based resources can improve the frequency response of renewable-rich microgrids. The synthesis of grid supportive modes to guarantee frequency trajectory constraints under a predefined disturbance set is challenging but essential. To tackle this challenge, a numerical optimal control (NOC)-based control synthesis methodology is proposed. Without loss of generality, a wind-diesel fed microgrid is studied, where we aim to design grid supportive functions in the wind turbine. In the control design, linearized models are used, and the linearization-induced errors are quantitatively analyzed by reachability and interval arithmetics and represented in the form of interval uncertainties. Then, the NOC problem can be formulated into a robust mixed-integer linear program. The control structure is strategically configured into two levels to realize online deployment. The proposed control is verified on the modified 33-node microgrid with a full-order three-phase nonlinear model in Simulink. In conclusion, the simulation results show the effectiveness of the proposed control paradigm and the necessity of considering linearization-induced uncertainty.

24 POWER TRANSMISSION AND DISTRIBUTION↗